Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDAENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: RAMSEY RESIDENCE City, State, Zip: HUTCHINSON ISLAND, FL, 34949 Owner: STEPHEN RAMSEY Design Location: FL, Fort Pierce 1, New construction or existing New (From Plans) 2. Single family or multiple family Single-family 3. Number of units, if multiple family 1 4. Number of Bedrooms 3 5, Is this a worst case? No 6. Conditioned floor area above grade (ft2) 2472 Conditioned floor area below grade (ft2) 0 7. Windows (458.7 sgft.) Description a. U-Factor: Sgl, U=0.45 SHGC: SHGC=0.42 b. U-Factor: Sgl, U=0.47 SHGC: SHGC=0.47 c. U-Factor: Sgl, U=0,46 SHGC: SHGC=0.55 d. U-Factor. other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types (2472.0 sgft.) Insulation a. Stab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= Area 128.33 ft2 80.00 ft2 75.00 W 175.33 ft2 6,334 ft, 0.428 Area 2472.00 W ft2 ft2 Builder Name: Permit Office: ST LUCIE COUNTY Permit Number: Jurisdiction: ST LUCIE COUNTY County: St. Lucle (Florida Climate Zone 2 } 9. Wall Types (2683.9 sgfl.) a. Concrete Block - Int Insul, Exterior b. Frame - Wood, Adjacent c. N/A d. NIA 10. Ceiling Types (2472.0 sqft.) a. Under Attic (Vented) b. N/A G. NIA 11, Ducts a. Sup: Attic, Rel: Attic, AH: Attic b, Sup: Attic, Ret: Attic, AH: Attic 12. Cooling systems a. Central Unit b. Central Unit 13. Heating systems a. Electric Strip Heat b. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 16. Credits Total Proposed Modified Loads: 75.14 Glass/Floor Area: 0.186 Total Baseline Loads: 81.46 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code, PREPARED Y; DATE: 11-T8-20 0 I hereby certify that this b ing, a es gned, Is in compliance with the Florida Energy C OW NERIAGENT' DATE: - Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be Inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: Insulation R=4.1 R=11.0 R= R= Insulation R=30.0 R= R= Area 2288.40 112 295.50 ft2 ft2 ft2 Area 2472.00 ft2 fe ft2 R ft2 6 150 6 150 kBtu/hr Efficiency 36.0 SEER:16.00 36.0 SEER:16.00 kBIu/hr Efficiency 27.0 COP:1.00 27.0 COP:1.00 Cap: 50 gallons EF: 0.980 None PASS - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402,4.1.2). 11/18/2020 1:22 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 �h. - mini IT cI IltnneeaV rur-ru'I IAT REPORT rvRrvi r��tva-w i r ..v■ v . ............. — — — — — - PROJECT Title: RAMSEY RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2472 Lot # Owner Name: STEPHEN RAMSEY Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No P1atBook: Builder Name: Rotate Angle: 0 Street: 135 N. PARLIAMENT C ----Permit-Offtce:--ST L-UC-IE-GOUNT--Y-- ----Gross Ventilation: —__No_-_ St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: HUTCHINSON ISLAND Family Type: Single -Family FL, 34949 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low 13LOCKS Number Name Area Volume 1 AHU 1 1246 10927 2 AHU 2 1226 11148.5 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 HALL 100 850 No 0 1 No Yes Yes 2 BEDROOM 3 168 1428 No 0 1 1 Yes Yes Yes 3 CLST 3 20 170 No 0 1 Yes Yes Yes 4 DEN 120 1020 No 0 1 Yes Yes Yes 5 BATH 2 90 765 No 0 1 Yes Yes Yes 6 CLST 2 20 170 No 0 1 Yes Yes Yes 7 BEDROOM 2 168 1428 No 0 1 1 Yes Yes Yes 8 M BATH 176 1496 No 0 1 Yes Yes Yes 9 M WIC 52 442 No 0 1 No Yes Yes 10 LAUNDRY RM 60 510 No 0 1 No Yes Yes 11 HALLWAY 100 850 No 0 1 No Yes Yes 12 PANTRY 22 187 No 0 1 No Yes Yes 13 KITCHEN/N OOK 247 2099.5 Yes 0 1 Yes Yes Yes 14 DINING RM 176 1760 No 0 1 Yes Yes Yes 15 FOYER 84 714 No 0 1 Yes Yes Yes 16 LIVING RM 224 2240 No 0 1 Yes Yes Yes 17 FAMILY RM 336 2856 No 0 1 Yes Yes Yes 18 MASTER BEDROO 309 3090 No 0 1 1 Yes Yes Yes 11/18/2020 1:22 PM EnergyGauge(D USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 r—tine f Anc nn47 !K101IT CI lhnllnAPV i-W1=rV1 I-qT RFPn RT I VINIVI W P��-- FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation HALL 1 It 0 100 ft? ---_ 1 0 0 2 Slab -On -Grade Edge Insulation BEDROOM 3 35 ft 0 168 ft2 ---- 1 0 0 ----- — - —3 Siab OrnGrade Edge insulation 6LST 3—__._2 ft—__---•-•---0----,�Oh— -------------- 1-- __- 0 0 -- - - 4 Slab -On -Grade Edge Insulation DEN 12 ft 0 120 fie ____ 1 0 0 5 Slab -On -Grade Edge Insulation BATH 2 9 ft 0 90 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation CLST 2 2 ft 0 20 W ____ 1 0 0 7 Slab -On -Grade Edge Insulation BEDROOM 2 38 ft 0 168 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulation M BATH 1811. 0 176 IF __._ 1 0 0 9 Slab -On -Grade Edge Insulation M WIC 1 ft 0 52 ft2 __._ 1 0 0 10SIab-On-Grade Edge Insulation LAUNDRY RM 1 ft 0 60 ft2 ___- 1 0 0 11Slab-On-Grade Edge Insulation HALLWAY 1 ft 0 100 fl2 ---- 1 0 0 12SIab-On-Grade Edge Insulation PANTRY 1 ft 0 22 IF .___ 1 0 0 13SIab-On-Grade Edge Insulation KITCHEN/N OOK 33.4 ft 0 247IF ---- 1 0 0 14SIab-On-Grade Edge Insulation DINING RM 14 ft 0 176 1`12 __-_ 1 0 0 15SIab-On-Grade Edge Insulation FOYER 7 ft 0 84 1`12 -___ 1 0 0 16SIab-On-Grade Edge Insulation LIVING RM 18 ft 0 224 ft2 __._ 1 0 0 17SIab-On-Grade Edge Insulation FAMILY RM 19 ft 0 336 ft2 __-_ 1 0 0 18SIab-On-Grade Edge Insulation MASTER BEDRO 47.6 ft 0 309 ft2 _--_ 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Barrel the 2765 ft2 0 IF Medium N 0.3 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2472 ft2 N N 11/18/2020 1:22 PM EnergyGauge(D USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) HALL 30 Blown 100 ft2 0.1 Wood 2 Under Attic (Vented) BEDROOM 3 30 Blown 168 ft2 0.1 Wood 3 Under Attic (Vented) CLST 3 30 Blown 20 I'll 0.1 Wood 0,1 Wood -- 5 Under Attic (Vented) BATH 2 30 Blown 90 112 0.1 Wood 6 Under Attic (Vented) CLST 2 30 Blown 20 ft2 0.1 Wood 7 Under Attic (Vented) BEDROOM 2 30 Blown 168 ft2 0.1 Wood 8 Under Attic (Vented) M BATH 30 Blown 176 ft2 0.1 Wood 9 Under Attic (Vented) M W IC 30 Blown 52 ft2 0.1 Wood 10 Under Attic (Vented) LAUNDRY RM 30 Blown 60 112 0.1 Wood 11 Under Attic (Vented) HALLWAY 30 Blown 100 ft2 0.1 Wood 12 Under Attic (Vented) PANTRY 30 Blown 22 fl2 0.1 Wood 13 Under Attic (Vented) KITCHEN/N OOK 30 Blown 247 W 0.1 Wood 14 Under Altic(Vented) DINING RM 30 Blown 176ft2 0.1 Wood 15 Under Attic (Vented) FOYER 30 Blown 84 W 0.1 Wood 16 Under Attic (Vented) LIVING RM 30 Blown 224 1`12 0.1 Wood 17 Under Attic (Vented) FAMILY RM 30 Blown 336 ft2 01 Wood 18 Under Attic (Vented) MASTER BEDRO 30 Blown 309 ft2 0.1 Wood WALLS Adjacent Space Cavity 11T�, p R-kf-', le Width Height Ft In Area Sheathing Framing RX Im, Fraclion Solar Absor Below Gra 1 N Exterior Concrete Block - Int insuBEDROOM 3 4.1 12 0 8 6 102.0 112 0 0 0.3 0 2 E Exterior Concrete Black - Int InsuBEDROOM 3 4.1 14 0 8 6 119.0 ft2 0 0 0.3 0 3 S Exterior Concrete Block - Int InsuBEDROOM 3 4.1 9 0 8 6 76.5 112 0 0 0.3 0 4 N Exterior Concrete Block- Int Insul CLST 3 4.1 2 0 S 6 17.0 112 0 0 0.3 0 _ 5 N Exterior Concrete Block - Int Insul DEN 4.1 12 0 8 6 102.0112 0 0 0.3 0 6 N Exterior Concrete Block - Int Insul BATH 2 4.1 9 0 8 6 76.5 ft2 0 0 0.3 0 7 N Exterior Concrete Block - Int Insul CLST 2 4.1 2 0 8 6 17.0 ft2 0 0 0.3 0 8 N Exterior Concrete Block - Int InsuBEDROOM 2 4.1 12 0 8 6 102.0 ft2 0 0 0.3 0 9 S Exterior Concrete Block -1nt InsuBEDROOM 2 4.1 12 0 8 6 102.0 ft2 0 0 0.3 0 _ 10 W Exterior Concrete Block - Int lnsul3EDROOM 2 4.1 14 0 B 6 119.0 fl2 0 0 0.3 0 __ 11 S Exterior Concrete Block - Int Insul M BATH 4.1 18 0 8 6 153.0 ft2 0 0 0.3 0 12 E Garage 'Frame -Wood M BATH 11 6 0 8 6 51.0 ft2 0 0.1 0.3 0 13 E Garage Frame - Wood LAUNDRY R 11 10 0 8 6 85.0 f12 0 0.1 0.3 0 _ 14 E Garage Frame - Wood HALLWAY 11 4 0 8 6 34.0 ft2 0 0.1 0.3 0 _ 15 E Garage Frame - Wood PANTRY 11 3 0 8 6 25.6 1`12 0 0.1 0.3 0 16 N Exterior Concrete Block - Int InsuKITCHEN/N 4.1 5 0 8 6 42.5 ft2 0 0 0.3 0 17 S Exterior Concrete Block - Int InsuKITCHEN/N 4.1 5 0 8 6 42.5 ft2 0 0 0.3 0 1S SW Exterior Concrete Block - Int InsuKITCHEN/N 4.1 4 3 8 6 36.1112 0 0 0.3 0 19 W Exterior Concrete Block - Int InsuKITCHEN/N 4A 15 0 8 6 127.5 ft2 0 0 0.3 0 _ 20 Y_ NW Exterior Concrete Block - Int InsuKITCHEN/N 4.1 4 3 8 6 36.1 ft2 0 0 0.3 0 21 N Exterior Concrete Block - Int InsulDINING RM 4.1 2 0 10 0 20.0 ft2 0 0 0.3 0 22 E Exterior Concrete Block - Int InsulDINING RM 4.1 12 0 10 0 120.0 ft2 0 0 0.3 0 11/18/20201:22 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below 11 Type Space p R-NI-lue Fr to Et In Area R-Value Ersclhn Qhs-. Gran ° _23 E Garage Frame -Wood DINING RM 11 2 0 10 0 20.0It2 0 0.1 0.3 0 24 S Garage Frame - Wood DINING RM 11 8 0 10 0 80.0 ft2 0 0.1 0.3 0 25 E Exterior Concrete Block- Int Insul FOYER 4.1 7 0 8 6 59.5 ft2 0 0 0.3 0 -Concrete BTock=1nT'lnsiil GIVING RM" _¢_1____.__-16__-._0-10 0--" t60;0Yt2___._-._0_.___._---.-0_...-_.__-..-.0:____._._-__0_._. 27 S Exterior Concrete Block- Int Insul LIVING RM 4.1 2 0 10 0 20.0 ft2 0 0 0.3 0 28 W Exterior Concrete Block - Int InsulFAMiLY RM 4.1 19 0 8 6 161.5 ft2 0 0 0.3 0 29 N Exterior Concrete Block- Int InsuMASTER BE 4.1 12 0 10 0 120.0 ft2 0 0 0.3 0 30 S Exterior Concrete Block - Int InsuMASTER BE 4.1 14 0 10 0 140.0 1`12 0 0 0.3 0 31 SW Exterior Concrete Block - Int InsuMASTER BE 4A 2 10 10 0 28.3 ft2 0 0 0.3 0 32 W Exterior Concrete Block - Int InsuMASTER BE 4.1 16 0 10 0 160.0 ft2 0 0 0.3 0 33 NW Exterior Concrete Block - Int InsuMASTER BE 4.1 2 10 10 0 28.3 ft2 0 0 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated HALLWAY None .23 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Single Yes 0.46 0.55 Y 15.0 ft2 3 ft 0 In 1 ft 4 in None None 2 E 2 Vinyl low-E Single Yes 0.46 0.55 Y 15.0 ft2 3 ft 0 in 1 ft 4 in None None 3 N 5 Vinyl Low-E Single Yes 0.46 0.55 Y 15.0 ft2 3 ft 0 in 1 fl 4 In None None 4 N 6 Vinyl Low-E Single Yes 0.45 0.55 Y 6.0 1`12 3 ft 0 In 1 ft 4 in None None 5 N 6 Vinyl Low-E Single Yes 0.45 0.42 Y 16.7 ft2 3 ft 0 in 1 ft 4 in None None 6 N 8 Vinyl Low-E Single Yes 0.46 0.55 Y 15.0 ft2 3 ft 0 in 1 ft 4 in None None 7 W 10 Vinyl Low-E Single Yes 0.46 0.55 Y 15.0 ft2 3 ft 0 in 1 f14 In None None 8 S 11 Vinyl Low-E Single Yes 0.45 0.42 Y 33.3 ft2 3 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 9 SW 18 Vinyl Low-E Single Yes 0.45 0.42 Y 20.0 ft2 3 ft 0 in 1 ft 4 in None. None 10 W 19 Vinyl Low-E Single Yes 0.42 0.42 Y 16.0 ft2 3 ft 0 in 1 ft 4 in None None 11 W 19 Vinyl Low-E Single Yes 0.42 0.42 Y 12.0 ft2 16 ft 0 in 1 ft 4 in None None 12 NW 20 Vinyl Low-E Single Yes 0.46 0.42 Y 16.0 ft2 3 ft 0 in 1 ft 4 in None None 13 E 22 Vinyl Low-E Single Yes 0.42 0.33 Y 36.0 ft2 3 ft 0 In 1 fl 4 In None None 14 E 25 Vinyl Low-E Single Yes 0.45 0.42 Y 13.3 fP 6 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 15 E 25 Vinyl Low-E Single Yes 0.46 0.42 Y 20.0 ft2 6 ft 0 in 1 It 4 In Drapes/blinds Exterior 5 16 E 26 Vinyl Low-E Single Yes 0.42 0.29 Y 36.0 ft2 3 ft 0 in 1 it 4 In None None 17 W 28 Vinyl Low-E Single Yes 0.47 0.47 Y 80.0 ft2 16 It 0 In 1 ft 4 in None None 18 N 29 Vinyl Low-E Single Yes 0.47 0.33 Y 33.3 it" 10 ft 0 In 1 ft 4 In Drapes/blinds Exterior 5 19 SW 31 Vinyl Low-E Single Yes 0.45 0.42 Y 10.0 ft' 3 ft 0 in 1 ft 4 In Drapeslblinds Exterior 5 20 W 32 Vinyl Low-E Single Yes 0.45 0.42 Y 25.0 ft2 3 fl 0 In 1 it 4 in Drapeslblinds Exterior 5 21 NW 33 Vinyl Low-E Single Yes 0.45 0.42 Y 10.0 ft2 3 fl 0 in 1 ft 4 in Drapeslblinds Exterior 5 11/18/2020 1:22 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 5 of 7 Mini r-r et lneneAMV hl-l=f`Vl lCT t?GPnP-r GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 700 ft2 700 if 33 ft 8 it 11 INFILTRATION # Scope Method _...,......_ SLA ... ..----- --- _._.__._ .__ _.__.____ CFM 50 ELA EgIA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000284 1839.6 100.99 189.93 .1027 5 HEATING SYSTEM # System Type Subtype Speed Efficlency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COP:1 27 kBtulhr 1 COPA 271<Btulhr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split Single SEER: 16 36 kBtu/hr 1080 cfm 0.8 1 Single SEER: 16 36 kBtulhr 1080 cfm 0.8 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None f I2 DUCTS # ---- Supply---- Location R-Value Area --- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 150 112 Attic 6 150 ft2 Attic Attic 151? Default Leakage Attic (Default) c(Default) c 15 ft2 Default Leakage Attic (Default) c(Default) c 1 1 2 2 11118/20201:22 PM EnergyGaugeE) USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 crnone onna')n,17 IKI01IT CI I6fiM®RV r il-IPrVII VRT RPP()RT TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Jan Feb Feb [[ jj Mar [X] Mar [) (] Apr Apr May May Jun Jun il M Jul Jul j1 Au E) Au Aug M Se Sep Se [ ]OclNov [ ] Oct X] Oct Nov Nov [ j DecHeatin X] DecVentin )Dec Jan Fob [[XX]] Mar [XJ A r ( L Ma Jun Jul ) lXJ [X] Thermostat Schedule: HERS 2006 Reference Hours -----.._,.3--------- ------- ______--7-------- 8--_.._..--g --------- Cooling (WD) AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 7B 80 78 80 78 80 78 80 78 Cooling (W EH) AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD) AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Defaull(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC Default(8 ibs/sq.ft, ft2 ft 0.3 MASTER BATH Default(8 Ibslsq.ft. fe it 0.3 TOILET Default(8 Ibs/sq.ft. fl2 ft 0.3 LINEN Default(8 Ibsisq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 It 0.3 DINING Default(8 Ibs/sq.fl. ft2 ft 0.3 LIVING ROOM Default(8 ibslsq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. fte ft 0.3 HALLWAY Default(8 Ibslsq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. fie ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.fL ft2 ft 0.3 BATH 2 Default(B Ibs/sq.ft. f12 ft 0.3 CLST 3 Default(8 Ibs/sq.ft. fie ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. W ft 0.3 NOOK Default(8lbs/sq.ft. ft2 ft 0.3 FAMILY RM Default(8 Ibs/s .fl. ft2 It 0.3 PANTRY 11118/20201:22 PM EnergyGauge® USA 6,0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & Insulation level a) Supply ducts R . 6.0 2. Single-family or multiple -family 2. Singe -family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. ft.) 6. 2472 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.461 b) Solar Heat Gain Coefficient (SHGC) 7b. 0,428 c) Area 7c. 458.7 8. Skylights a) U-factor:(weighted average) Sa. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier Installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 10131. 11.0 10B2. 11a. 30.0 11 b. 11 c. 11 d. No 13. Cooling system: Capacity 72.0 a) Split system SEER 16.0 b) Single package SEER c) Ground/water source SEER/COP d) Room unit/PTAC EER e) Other 14. Heating system: Capacity 54.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.98 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit f) Programmable thermostat No "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. i certify that this home has compiled with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 135 N. PARLIAMENT COURT City/FL Zip: HUTCHINSON ISLAND, FL 34949 11/18t202O 1:23:45 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1