HomeMy WebLinkAboutProduct Approval of 3
Florida Building Code Online fr51 t
f" I ��t �c•
.�
• ..,, ii{kq�""�q �y�$$txq_'kx p S y, y� F-� j Sp � $ �y��G �Y;� b",�"'$^4�� $8& A`� '..
§/';t' d$ 4i �f �� .�• '3 S r;„ ^,
....,x..w.._..c°`w.'...a.....a„•zHa: =.e.w.a,.. u,,,......w,w......,..,..,,..�.....m..... ....................... R�'€....'.
• BCIS Home Log In User Registration ` Hot Topics Submit Surcharge ; Stats&Facts Publications i FBC Staff BCIS Site Map Links Search
b
r
Poduct
Approval
d r ii on :
Uublic User
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL14104-R13
PP Type Application T e .Revision
Code Version 2014
Application Status Approved
*Approved by DBPR..Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission'if necessary.
Comments
Archived ❑
Product Manufacturer ]ELD-WEN
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls,OR 97601
(800) 535-3936
fbcl@jeld-wen.com
Authorized Signature Kaede McLaughlin
fbcl@jeld-wen.com
Technical Representative JELD-WEN Corporate Customer Service
Address/Phone/Email 3737 Lakeport Blvd:
Klamath Falls,OR 97601
-, (800) 535-3936
customerserviceagents@jeld-wen.com
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Single Hung
Compliance Method Certification Mark or Listing
Certification Agency American Architectural Manufacturers Association
Validated By American Architectural Manufacturers Association
Referenced Standard and Year (of Standard) Standard Year
AAMA/WDMA/CSA 101/I.S.2/A440 2008
Equivalence of Product Standards
i Certified By
Product Approval Method Method 1 Option A
Date Submitted 10/21/2016
Date Validated 10/28/2016
Date Pending FBC Approval
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtD gsKhgANvD gZ... 2/24/2017
Florida Building Code Online Page 2 of 3
4 " 1y
Date Approved 11/02/2016 k1 �� • � ::,,3
Summary of Products t111
FL# Model, Number or Name Description
14104.1 Builders Vinyl (V-2500) Tilt Single Hung 48"x 77"Annealed Insulated Glass
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL14104 R13 C CAC R-PG50-48x77.pdf
Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 10/04/2021
Design Pressure: +50/-50 Installation Instructions
Other: FI14104 R13 II R-PG50-
48x77 Installation Instructions.pdf
Verified By: American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
FL14104 R13 AE PER 3078.pdf
Created by Independent Third Party: Yes
14104.2 Builders Vinyl (V-2500) Two Wide Tilt Single Hung 84"x 57" Annealed Insulated
Glass
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL14104 R13 C CAC XX R-PG50-84x57.pdf
Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 08/28/2021
Design Pressure: +50/-50 Installation Instructions
Other: FL14104 R13 II R-PG50-
84x57 Installation Instructions.ndf
Verified By: American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
FL14104 R13 AE PER 3076.pdf
Created by Independent Third Party: Yes
--t
14104.3 Builders Vinyl(V-2500) Three Wide Tilt Single Hung 108" x 74"Annealed Insulated
Glass
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL14104 R13 C CAC XXX R-PG50 108x74.pdf
Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 01/26/2021
Design Pressure: +50/-50 Installation Instructions
Other: FL14104 R13 II BV-Triple TSH CHS PG50
108x74 SJW2012-014 Nail Fin 5-25-16.pdf
Verified By: American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
14104.4 Builders Vinyl (V-2500) Three Wide With Center Picture Tilt Single Hung 109"x 74"
Annealed Insulated Glass
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL14104 R13 C CAC XOX R-PG50-109x74.pdf
Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 01/29/2022
Design Pressure: +50/-50 Installation Instructions
Other: FL14104 R13 II XOX R-PG50-
109x74 Installation Instructions.Of
Verified By: American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
FL14104 R13 AE PER 3077.pdf
Created by Independent Third.Party: Yes
14104.5 Builders Vinyl(V-2500) Tilt Single Hung 36"x 84"Annealed Insulated Glass
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL14104 R13 C CAC R-PG35-36x84.pdf
Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 12/20/2019
Design Pressure: +35/-35 Installation Instructions
Other: FL14104 R13 II R-PG35-
36x84 Nail Fin Installation Instructions.pdf
Verified By: American Architectural Manufacturers
Association
Created by Independent Third Party:
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKhgANvDgZ... 2/24/2017
—....----- -- ------.—....----— — ---------......_._._...._... ....— -.....................-----._...._.....................__.._........................_.......
_
4" MAX. 11/2"MIN.EMBEDMENT NAIL FIN INSTALLATION
12" O.C. MAX. FROM
THRU FIN —}---}—�-CORNERS 1
2 2X WOOD FRAME
MIN.DISTANCE
MIN.DISTANCE FOR EDGE:3/4"
MAX.
12" O.C. FOR EDGE:3/4" 2X WOOD
AX. THRU
THRU FIN 1/4'MAX 3 FRAME
SHIM SPACE 3
i
2
Y- 1/4"MAX
SHIM SPACE
FRAME SECTION(TYP) l MIN.
Jf VERTICAL SECTION EMBBEE DMENT
H MTE'Li
[mAl hclvun Nai'liy Fbyc 3 Wcad Openly —
L
= i�% MIDSPAN
o
0
z
3
I
j JAMB SECTION(TYP)
j HORIZONTAL SECTION
1/4"MAX NOTE:Caulk between Nailing Fl—d-.1 Opening.
SHIM SPACE --.--.
MIN.DISTANCE
FOR EDGE:3/4" BUILDERS VINYL SINGLE HUNG
WINDOW WIDTH (48" MAX.) t 2 2XWOODFRAME Max Frame DP RATING IMPACT
11/2"MIN.EMBEDMENT 48 �( 77 +50/-50 N�
TYPICAL ELEVATION WITH FASTENER SPACING
Installation Notes: General Notes:
1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria
2. Use#8 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 1/2" of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida
into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)and the industry requirement for the stated conditions.
3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300.
to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing shall be single strength annealed insulating glass.
project of installation. 4. Use structural or composite shims where required. r t
5. Maximum sizes are buck sizes and do not include fin or flange.
Digitally signed by Hermes F.Norero,P.E. _;., ., u
This schedule addresses only the fasteners required to anchor the Reason:I am approving this document
window to achieve the rated design pressure up to the size limitations Date:2014.0``Q4VV1��:��4�0>Mpp�'
noted. It is not intended as a guide to the installation process and does �� �♦ PROJECT ENGINEER: DATE: 4 r
♦ ♦ 3737 Lakeport Blvd=
not address the sealing consideration that may arise in different wall Q' ; , ♦♦ -- 07/17/2014 JEL N Klamath Falls,OR.9760f," c
conditions. For the complete installation procedure,see the instructions . DRAWN BY: SCALE:
p p 1 0 D.Vezo NTS Phone: (541)882-3451' '�" 'f
packaged with the window or go to 7 ., '
�--;"" .. CHECKED BY: TITLE:
www.jeld-wen.com/resourceslinstallation. _ * 7E _ J. Kantola
DISCLAIMER: T/�T •� a = APPROVED BY: Builders Vinyl Tilt Single Hung I = .
: � '••• �,/�� / ��This drawingand its contents are confidential and are not to be % DP • PART PRO ECi No:
.♦ . , rrsr'o �.� D60499
reproduced or copied in whole or in part or used or disclosed to others ♦♦ a� ,. 7 �
except as authorized by JELD-WEN Inc. 3s8 ��8f S 338 IDENTIFIER
C NT NAME AND LOCATION: BldrsVinyITSH R� 00 SHEET
1 OF 4
.........----.........._........_..............---------_._..-....................................._........._._..---......._.._._._...._.__..._....._ ..._._...........................................__.........._.._.._................_..........----..........._............_...._..............._ THROUGH FRAME
4" MAX. MIN.DI5TANCE A 7 T
LL
FROM FOR EDGE-3/4" i INSTAATION
r-r CORNERS 3
2 1 1/2"MIN.
DSP N 11" O.C. EMBEDMENT
MI A
: MAX. THRU 1 1/2"MIN.
THRU JAMB 1/4°MAX EMBEDMENT
SHIM SPACE
1/4"MAX
FRAME SECTION(TYP) 3 SHIM SPACE
X VERTICAL SECTION o
X
MIN.DISTANCE 2
FOR EDGE:3/4"
U' j -
W
_ MIDSPAN
o A: -
o
z_
3 JAMB SECTION(TYP)
j HORIZONTAL SECTION
P5
I/4"MAX I
5HIM SPACE
141
2 11/2°MIN.
— I EMBEDMENT BUILDERS VINYL SINGLE HUNG
WINDOW WIDTH (48" MAX.)-I s Max Frame DP RATING IMPACT
TYPICAL ELEVATION WITH FASTENER SPACING MIN.DISTANCE
48 x 77 +50/-50 NO
FOR EDGE:3/4"
Installation Notes: General Notes:
1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria
2. Use#t8 PH or greater fastener though the frame with sufficient length to penetrate a minimum of 1 1/2" of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida
into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)and the industry requirement for the stated conditions.
3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300.
to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing shall be single strength annealed insulating glass.
project of installation. 4. Use structural or composite shims where required.
5. Maximum sizes are buck sizes and do not include fin or flange.
This schedule addresses only the fasteners required to anchor the
window to achieve the rated design pressure up to the size limitations
noted. It is not intended as a guide to the installation process and does PROJECT ENGINEER: DATE: '
not address the sealingconsideration that may arise in different wall �� F'' F �� -- 07/17/2014 JELDrWENKlarnath
3737 Lakeport Blvd.� p Falls OR 97601
conditions. For the complete installation procedure,see the instructions � � DRAWN BY: SCALE:
p p �' 1 O D.Vezo NTS Phone: (541)q,8 -3451
packaged with the window or go to 7 _:
CHECKED BY: TITLE:
www.jeld-wen.com/resources/installation. _ * 7k _ J. Kantola
TT�T = APPROVED Builders Vinyl Tilt Single Hung
DISCLAIMER: . A This drawingand its contents are confidential and are not to be % gL r. : PART PRO ECT No.
.� 'bs. ,k;rero �.� D60499
reproduced or copied in whole or in part or used or disclosed to others �� as o.
except as authorized by JELD-WEN Inc. Sea >�.eIb a 33B 1SJW2012-202-F C NT NAME AND LOCATION: BdfSVI 1yITSH REV. oo SHEET
"93' 2 OF 4
._.._._........_.._..---._._..._._...- -.....___..._...---- .....................................-----._..__......--.._._.........
--..._ ._..........._...----...._..._..-- —._.._._....._.__.._.._....._................---------
a^ MAX. RY I MASONRY INSTALLATION
FROM MASON MIN.DISTANCE
--rCORNERS BLOCK FOR EDGE:21/2'
'e11/4'MIN.
11^ D.C. 3 EMBEDMENT
MIDSPAN MAX. THRU d'.
THRU JAMB Iva°MIN•
1 EMBEDMENT
i
1 I
;
I i
1/4•MAX I *" 5'HIM
"
SHIM SPACE 171 MIN.DISTANCE
a FRAME SECTION(TYP) FOR EDGE:2 I/2 VERTICAL SECTION _
W
_ MIDSPAN MAsoNRY
BLOCK
3 Z
JAMB SECTION(TYP)
HORIZONTAL SECTION
SHIM
MAX
SHIM SPACE
-a .2-v •• EMBEDMENT i BUILDER5 VINYL 5INGLE HUNG
3 4 Max Frame DP RATING IMPACT
WINDOW WIDTH (48^ MAX.) I 1
MASONRY MIN.DI5TANCE I 48 x 77 +50/-50 1 NO
TYPICAL ELEVATION WITH FASTENER SPACING BLOCK FOR EDGE:21/2`
Installation Notes: General Notes:
1. Seal flangelframe to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria
2. Use 3/16"Tapcon or equivalent fasteners through frame with sufficient length to penetrate a minimum of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida
of 1 1/4"into concrete or masonry at each location with a 21/2"min from edge distance. For concrete Building Code(FBC)and the industry requirement for the stated conditions.
(min.=3000psi)or masonry(CMU shall conform to ASTM C90). 2. All glazing shall conform to ASTM E1300.
3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 3. At minimum,glazing shall be single strength annealed insulating glass.
to the structure. The host structure is the responsibility of the architect or engineer of record for the 4. Use structural or composite shims where required.
project of installation. 5. Maximum sizes are buck sizes and do not include fin or flange.
This schedule addresses only the fasteners required to anchor ther-
window to achieve the rated design pressure up to the size limitations 00 .i/
noted. It is not intended as a guide to the installation process and does PROJECT ENGINEER: DATE:
3737 Lakeport-$FWd
not address the sealing consideration that may arise in different wall Q' �� -- 07/17/2 114
�(/ ��� Klamath Falls,OR:97601=:
conditions. For the complete installation procedure,see the instructions DRAWN BY: SCALE:
I'; D.Vezo NTS Phone: (541)882=34;51
packaged with the window or go to 7 r CHECKED BY: TITLE:
www.jeld-wen.com/resources/installation. J. Kantola
-n TA p = APPROVED BY: Builders Vinyl Tilt Single Hung
DISCLAIMER: 3 l / U✓This drawing and its contents are confidential and are not to be OP PART PR0 ECT No:
FI ••t-s, ,orrer0 >, D60499
reproduced or copied in whole or in part or used or disclosed to others �I �aa xo. —,
except as authorized by JELD-WEN Inc. 3se d dpe . 338 IDENTIFIER No, PLANT NAME AND LOCATION: CAD DWG.NO.: REV: SHEET
SJW2012-202-F C BldrsVinyITSH 00 30F4
1
__........................................................................._.. --........._._._.........................._.................__..........---4" MAX..._......__........_......_....-- - _............._....._.............._......_......__...MIN.DISTANCE..._._...._..........._............._.........I STEEL INSTALLATION
FROM FOR EDGE:1/2"
�---r•CORNERS in.embedment
�pa past
threads
2 3 past frame I
18 gauge min
MIDSPAN MAXO.C. S gauge min Steel Stud
AX. THRU Steel Stud
THRU JAMB
1/4"MAX
SHIM SPACE le
"
MIN.DISTANCE 3
i
ar_ FRAME SECTION(TYP) FOR EDGE:1/2"VERTICAL SECTION
Min.embedmentof threethreadsj
past frame
x
r,
w
MIDSPAN
0
3 JAMB SECTION(TYP) '
I HORIZONTAL SECTION
0 1/4"MAX
SHIM SPACE
18 gorge min
Steel Stud BUILDERS VINYL SINGLE HUNG
2 3 Min.embedment
of three threads Max Frame I DP RATING IMPACT
WINDOW WIDTH (48" MAX.) I past frame
TYPICAL ELEVATION WITH FASTENER SPACING MIN.DIGTANCE 48 x 77 +50/-50 NO
FOR EDGE:I/2"
Installation Notes: General Notes:
1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria
2. For anchoring into metal framing,use#8 TEK Self Tapping screws with sufficient length to achieve a of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida
minimum embedment of three threads past the frame thickness. Locate anchors as shown in Building Code(FBC)and the industry requirement for the stated conditions.
elevations and installation details. Steel substrate min.18ga.,fy=33 ksi. 2. All glazing shall conform to ASTM E1300.
3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 3. At minimum,glazing shall be single strength annealed insulating glass.
to the structure. The host structure is the responsibility of the architect or engineer of record for the 4. Use structural or composite shims where required. • _=
project of installation. 5. Maximum sizes are buck sizes and do not include fin or flange.
This schedule addresses only the fasteners required to anchor the `,,��
window to achieve the rated design pressure up to the size limitations �� If/1
i1
noted, It is not intended as a guide to the installation process and does �� �� PROJECT ENGINEER: DATE:
3737 Lakeport-Blvd
not address the sealingconsideration that may arise in different wall �c -- 07/17/2014 T J
J AT C;.
conditions. For the complete installation procedure,see the instructions : J : �� g, Klamath Falls,OR.
DRAWN BY: SCALE:
p p f�; D.Vezo NTS Phone: (541)8823A51
packaged with the window or go to — 7 - = CHECKED BY: TITLE:
www.jeld-wen.comlresources/installation. J. Kantola I,. i
APPROVED BY: Builders Vinyl Tilt Single Hung
DISCLAIMER: : �� w -- �<<
This drawingand its contents are confidential and are not to be % RL DP PART PRO Ecr No
i1 FI ''bs. ,o;ret-o �.� D008499
reproduced or copied in whole or in part or used or disclosed to others el �da No. 9
except as authorized b JELD-WEN Inc. 398 E� 338 IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG,No.: REV: SHEET
p y a�1. SJW2012-202-F C BldrsVinyITSH 00 4 of 4