HomeMy WebLinkAboutBlower Door Test JM Climate Pro' Fiber Glass Mowing wool
.Your home has been professionally insulated to provide superior thermal resistance.
Homeowner's Name Date
Address t
City . State Zip
RECORD OF INSTALLATION
BLOWING.WOOL BATTS AND ROLLS
ew Construction If Retrofit: R-VALUE THICKNESS AREA INSULATED
❑Retrofit Depth of Previous insulation in. Ceilings in: sq.ft.
Number of bags used Estimated R-value of Previous Installation in. sq.ft.
Area Insulated. sq.ft. Types of Previous Insulation in Attie Walls ( J in. L jzq`fi p
3 /
Thickness of Insulation in, /( in. L�J�sq.ft.
R-value:of Insulation CO
- Fioois in. sq.ft.
P
in. sq.ft.
CLIMATE PRO INSULATION,BAG WEIGHT-.28.5 LB.MINIMUM
R-VALUE MINIMUM INSTALLED SETTLED THICKNESS(in) BAGS PER t,000 SO.FL MAXIMUM NET MINIMUM WEIGHT
,
(hr•sq.it•°F/BTU) THICKNESS(in.) COVERAGE,(sq.ft./hag) (Ibs./sq.ft.)
To obtain an insulation Installed insulation Expected thickness Minimum number'df Contents of this bag The weight per sq.ft.
resistance(R)of should not be less after long-term settling bags per 1,000 sq.ft. should not cover of installed insulation
than: has occured of net area: more than: should not be less than;.
11 4.3 4.3 4.8 209. 0.150
13 5.0 5.0 5.7 176 0.179
19 7.2 7.2 8A 118 0.266
22 8.3 8.3 9.9 101 0.310
26 9.7 9.7 11.8 85 0.371
30 11:1 11.1 13.7 73 0.432
38 13:8 13.8 17.7 56 0.559
44 15-7 15.7 20.8 48 0.656
49 17.3 17.3 23.5 43 0.739
60 20.7 20.7 29.5 34 0.928
See reverse to determine adjustment in coverage for Climare Pro Insulation installed in Minnesota.
Insulation Contractor Signature Date, / 2y /•7
S p�Cr
Company 7 s ddress lY , (- Phone �a - �S= 7 �.
Home Builder Signature Date
Company Address Phone
1217
�ECEp '
Johns Manville JUN'2 9 201?
For more information,call 1-!?00-654-3103. BIC-162 4/13 02013 Johns Manville.717 17th Street,Denver,CO 80202
........-_...
..........
f;
Johns Manville
117'17th Street
Denver;CO 86202
'i-800-554-31t?3 �•-
That. M�DS°l' BE filled o and posted to comply m h
building codel requirements.Meets.IRC Sections N1 101.3,
N- .1 M AA: Ni 101.8. requirements.
The..foilovAng spray applied.polyurethane foam product(s)have'been installed:.
O 51 i ICC ES ESR-13776
JM Corban.d®' acx SPF 0.5 l l a: ES E -372
E JM Corbond I110 2.0 IbIfe UES E -014.
M Corbond 'CST" 2 0 IbW ICC ES ESR, 159
In accordance with the intematonal Building Code,Chapter 2& and the International:Residential Code,
RaA requirements for the foam plastics the insulation:sysLem(s)referenced above have:beeq-instalied
aecording;#o manufact-urers'recommendations and.to'local bUiitl'mg cedelequiuements. For addl6©nal
rec=mendations.referto.ICC ESESR--3776 farJM Corbond®oc SPE,IAPMO:UES ER 372forJIVI
torbond®.ocx SPF,1PNtO fJES ER:D14G for JM Carhoni3111�,and lCC ES(ESR-3159for JM Cottionii
MCS;m.Thefollowing_thermal resistarice values hava'beert installed,
AREA INSU ATE-0 R-Value Thickness finches)*
At is-Area A
c3ped Ceilings
Walls
Floors.
Other:
Other.
#Norm 0 th'idmesses are represerdaWe of field spray-applied foam.mate"
• fj
Job-sirte Aridness:
Building Contractor I
Insulation Contractorhone• 7 —i 0
installed y u� S StI {l Date of Installation.;:
— 0S NEAR, ELE. TR.I.Q A LPANEL