HomeMy WebLinkAboutCCF_00046400
i
TRI
EVALUATION REPORT
GAF
1 Campus Drive
Parsippany, NJ 07054
(800)766-3411
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
ERD
353 CHRISTIAN STREET, UNIT #13
ER OXFORD, CT 06478
(203)262-9245
Evaluation Report 01506.01.08-1122
F1.10124-1120
Date of Issuance: 01/03/2008
Revision 22: 09/20/2017
SCOPE:
This Evaluation Report s issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials i i the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the prcJuct under the Florida Building Code and Florida Building Code, Residential Volume. The
products described her ain have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Aspljalt Roof Shingles
LABELING: Labeling sh I be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1.
CONTINUED COMPLIANC This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Asst rance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evalt ation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or th referenced Quality Assurance documentation changes. Trinity IERD requires a complete
review of this Evaluatioi i Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Ev duation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. 11 any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon requ t, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, .E.
Florida Registration No. 59 6, Florida DCA ANE1983
CERTIFICATION OF INDEPENDENCI
1. Trinity I ERD does not
distributing products it
2. Trinity I ERD is not own
3. Robert Nieminen, P.E.
which the evaluation r,
4. Robert Nieminen, P.E.
product.
5. This is a building code
project on which this E
specifically for that pur
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 09/20/2017. This does not serve as an electronically signed
document.
ve, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
jaluates.
, operated or controlled by any company manufacturing or distributing products it evaluates.
)es not have nor will acquire, a financial interest in any company manufacturing or distributing products for
orts are being issued.
)es not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
,aluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
luation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
ROOFING SYSTEMS
1. SCOPE:
Product Category
Sub -Category:
Compliance Stab
following section
through testing ii
and Limitations /
2. STANDARDS:
Section
1507.2.4 / 1507.1.1
R905.2.3 / R905.1.1
1507.2.5, R905.2.4
1507.2.7.1, R905.2.
1507.2.7.1, R905.2.
1507.2.7.1, R905.2.
REFERENCES:
Entity
GAF (PDM 1915)
PRI(TST 5878)
PRI(TST 5878)
PRI (TST 5878)
PRI(TST 5878)
PRI(TST 5878)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL(TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL(TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UI. (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
Exterior Research and Design,
Certificate of Authorization #9503
wRtc` .
TRINITY ERD
Roofing
Asphalt Shingles
nent: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the
of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume
accordance with the following Standards, Compliance is subject to the Installation Requirements
itions of Use set forth herein.
Property
Standard
Year
Physical Properties
ASTM D1970
2015
Physical Properties
ASTM D3462
2010
Wind Resistance
ASTM D3161
2016
Wind Resistance
ASTM D7158
2011
Wind Resistance
TAS 107
1995
Examination
Reference
Date
Letter of Equivalency
Seal -A -Ridge Impact Resistant IR
01/13/2012
Physical Properties
GAF-025-02-01
03/27/2002
ASTM D3462
GAF-059-02-01
09/02/2004
ASTM D3462
GAF-080-02-01
05/25/2005
Physical Properties
GAF-324-02-01
12/01/2011
Wind Driven Rain
GAF-407-02-01
01/21/2013
ASTM D3462
93NK6295
11/29/1993
ASTM D3462
99NK43835
01/12/2000
TAS 107
94NK9632
03/29/2000
ASTM D3462
OINK06632
02/02/2001
ASTM D3161,TAS 107
OINK9226
05/21/2001
ASTM D3161
OINK37122
12/18/2001
ASTM D3462
OINK37122
12/19/2001
ASTM D3161,TAS 107
02NK12980
04/10/2002
ASTM D3161,TAS 107
02NK30871
09/09/2002
ASTM D3161
03CA5367
03/11/2003
ASTM D3462
03NK26444
10/17/2003
ASTM D3462
04NK13850
06/07/2004
ASTM D3161
04NK13850
06/23/2004
ASTM D3161
04NK30546
03/10/2005
ASTM D3462
04NK22009
05/06/2005
ASTM D3161
04NK22009
05/09/2005
ASTM D3462
05NK27924
02/10/2006
ASTM D3161
05NK27924
02/11/2006
ASTM D3161,D3462
06CA18077
06/05/2006
ASTM D3161,D3462
06CA18074
06/16/2006
ASTM D3161,D3462
06CA35251
10/18/2006
ASTM D3462
06CA21602
12/01/2006
ASTM D3161,133462
06CA41095
12/27/2006
ASTM D3161
07NK05228
03/13/2007
ASTM D3161
06CA31611
04/04/2007
ASTM D3161
06CA61148
04/09/2007
ASTM D3161,133462
07CA31742
11/08/2007
ASTM D3161,D7158,D3462
OSCA06100
03/13/2008
Evaluation Report 01506.01.08-R22
6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-R20
GAF Asphalt Roof Shingles Revision 22: 09/20/2017
Page 2 of 6
Entity
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL (TST 1740)
UL, LLC. (TST 9628)
UL, LLC. (TST 9628)
UL, LLC. (TST 9628)
UL, LLC. (TST 9628)
UL, LLC. (TST 9628)
UL, LLC. (TST 9628)
UL, LLC. (TST 9628)
UL, LLC. (QUA 9625
UL, LLC. (QUA 9625
UL, LLC. (QUA 9625
UL, LLC. (QUA 9625
UL, I.I.C. (QUA 9625
UL, LLC. (QUA 9625
UL, I.I.C. (QUA 9625
UL, LLC. (QUA 9625
UL, LLC. (QUA 9625
UL, LLC. (QUA 9625
UL, LLC. (QUA 9625
UL, I.I.C. (QUA 9625
UL, LLC. (QUA 9625
4. PRODUCT DESCRlitriON:
Examination
ASTM D3161, D3462
ASTM D3161, D3462
ASTM D3161, D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3462
ASTM D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
ASTM D3462
ASTM D3161, D7158, D3462
ASTM D3161
ASTM D3161
ASTM D3161
ASTM D3161, D7158, D3462
ASTM D3161, D7158, D3462
Quality Control
Quality Control
Quality Control
Quality Control
Quality Control
Quality Control
Quality Control
Quality Control
Quality Control
Quality Control
Quality Control
Quality Control
Quality Control
.......n
TRINITY I ERD
Reference
07CA55908
09CA10592
09CA06856
09NK06647
09CA27281
10CA35554
10CA13686
10CA07264
IOCA11953
1ONK11951
1ONK12070
08CA06100
10CA53934
11CA48924
11CA47919
11CA48408
11CA48725
12CA34891
12CA58151
12CA38083
13CA32332
13CA37934
4786875675
4787434542
Inspection Report, R21, Mobile, AL
Inspection Report, R21, Myerstown, PA
Inspection Report, R21, Tuscaloosa, AL
Inspection Report, R21, Michigan Cty, IN
Inspection Report, R21, Shafter, CA
Inspection Report, R21, Savannah, GA
Inspection Report, R21, Minneapolis, MN
Inspection Report, R21, Mt. Vernon, IN
Inspection Report, R21, Baltimore, MD
Inspection Report, R21, Tampa, FL
Inspection Report, R21, Dallas, TX
Inspection Report, R21, Ennis, TX
Inspection Report, R21, Fontana, CA
Date
04/01/2008
03/26/2009
05/15/2009
08/01/2009
08/27/2009
03/05/2010
05/15/2010
05/27/2010
10/29/2010
10/30/2010
11/04/2010
01/30/2010
03/31/2011
10/22/2011
12/03/2011
12/08/2011
12/09/2011
10/12/2012
02/15/2013
02/26/2013
06/18/2013
08/02/2013
07/17/2015
05/17/2016
10/25/2016
10/20/2016
11/11/2016
11/01/2016
11/17/2016
11/11/2016
10/25/2016
10/25/2016
10/21/2016
11/17/2016
11/04/2016
11/03/2016
11/01/2016
4.1 As halt hin les:
4.1.1 Marquis I WeatherMax®, Royal Sovereign"' and Sentinel® are a fiberglass reinforced 3-tab asphalt roof
shingles
4.1.2 Camelot', Camelot® II, Fortitude'", Glenwood'", Grand Canyon"', Grand Sequoia"', Grand Sequoia® IR,
Grand equoia® ArmorShield'", Monaco"', Sienna"', Timberline® American Harvest"', Timberline®
Armors field'"" II, Timberline® Natural Shadow®, Timberline HD"', Timberline® Cool Series°, Timberline Ultra
HD`0 an Woodland® are fiberglass reinforced, laminated asphalt roof shingles.
4.1.3 Slatelin is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip & F
4.2.1 Seal -A -
Armor!
and rid
gel' Ridge Cap Shingles, Seal -A -Ridge® IR Impact -Resistant Ridge Cap Shingles, Seal -A -Ridge®
ald'"' Ridge Cap Shingles and Timbertex® Premium Ridge Cap Shingles are fiberglass reinforced, hip
asphalt roof shingles.
Exterior Research and Design, LC. Evaluation Report 01506.01.08-1122
Certificate of Authorization #9503 6"EDITION (2017) FEC NON-HVHZ EVALUATION FL10124-R20
GAF Asphalt Roof Shingles Revision 22: 09/20/2017
Page 3 of 6
a r .
4.3 Access
4.3.1 Pro -Start I Eave/Rake Starter Strip Shingles and WeatherBlockerTM Premium Eave/Rake Starter Strip Shingles
are start r strips for asphalt roof shingles.
4.3.2 QuickSta ® Peel & Stick Starter Roll is a is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS
modified bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6-
inch or As.
4.3.3 StarterM tchT"" Starter Strip Shingles are color -coordinated starter strips for use with Grand Canyon® and
Grand S uoia® series asphalt shingles. StarterMatchT"' are installed as the second starter for Grand
Canyon® nd Grand SequoiaO series installations.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evalt iation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Clas ification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Director for fire ratings of this product.
5.4 Wind Cla sification:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6 1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to Vasa = 150 mph (Vuit = 194 mph). Refer to Section 6 for installation requirements
to meet I his wind rating.
5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and R90 .2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up
to Vasd = 50 mph (V,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.3 Classific ion by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a
mean r f height of 60 feet or less. Calculations by a qualified design professional are required for
conditio s outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.5 All prod is in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 Underla ment:
6.1.1 Underla ment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be
Locally A
Dproved per Rule 61G20-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3.
6.2
Starter S
lingles or Starter Strip:
6.2.1
Installati
n of Pro -Start Eave/Rake Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip
Shingles
and QuickStart Peel & Stick Starter Roll shall comply with the GAF current published instructions.
6.3
As halt
hin les:
6.3.1
Installati
n of asphalt shingles shall comply with the GAF current published instructions, using minimum four
(4) nails
er shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
r Car
lelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield,
anc
Woodland require minimum five (5) nails per shingle.
Sla
eline requires minimum six (6) nails per shingle.
6.3.2
Fastener
shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6
or R905.
I.S. Staples are not permitted.
6.3.3
Where t
ie roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required
Contact the GAF for details.
Exterior Research and Design, Itc. Evaluation Report 01506.01.08-R22
Certificate oJAuthorhation #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-R20
GAF Asphalt Roof Shingles Revision 22: 09/20/2017
Page 4 of 6
6.4 Hip & RiI
6.4.1 Installati
Seal-A-R
a minim
beads of
(168811t94
w�
TRINITY 1 ERD
n of Seal -A -Ridge Ridge Cap Shingles, Seal -A -Ridge IR Impact -Resistant Ridge Cap Shingles and
ge ArmorShield Ridge Cap Shingles shall comply with the GAF current published instructions with
m two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter
enkel "Loctite PL S30 Roof & Flashing Sealant".
11.5' Sealant
� {292 mm) 1 ° Sellante
(25 rnrn) (25 mm) Enduit d'etancheite
� ♦ 12"
I (305 mm)
Nail
Clavo
;8" Clouer
12"
!305 rnml
6.4.2 Installatii in of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions
with a m nimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NP1
Gun Gra a Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant.
Iva* ,..... Wryl
1" (: rnrrry')...... .a...........t.. g Yoko lt*
25 rnrnp Q�25 rrtrn`, �n#fuetd`lrgenw>flwtp
F NO
,�'� y ,; �`:i a � •" a ;f, ;�2`,
i0ouker ;305 tnrnl
91'
12n MM
6.4.3 Fastene
R905.2.
Exterior Research and Design, I
Certificate of Authorization #9503
1r
i305 m lr)
shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or
Staples are not permitted.
Evaluation Report 01506.01.08-R22
6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-R20
GAF Asphalt Roof Shingles Revision 22: 09/20/2017
Page 5 of 6
7.
8.
z
10.
LABELING:
7.1 Labeling
herein.
7.2 Asphalt s
Table 15
BUILDING PERMIT
As required by th
this product.
I be in accordance with the requirements the Accredited Quality Assurance Agency noted
ngle wrappers shall indicate compliance with one of the required classifications detailed in FBC
.2.7.1 / R905.2.6.1.
EQUIREMENTS:
Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
MANUFACTURING LANTS:
Contact the name A CIA entity for information on which plants produce products covered by Florida Rule 61G20-3 CIA
requirements.
QUALITY ASSURAN CE ENTITY:
U L LLC — QUA962 ; (847) 664-3281
- END OF EVALUATION REPORT -
Exterior Research and Design, LC. Evaluation Report 01506.01.08-1122
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVH2 EVALUATION F1.10124-1120
GAF Asphalt Roof Shingles Revision 22: 09/20/2017
Page 6 of 6