HomeMy WebLinkAboutFord Hydralics�`-� The Association of Poo) & Spa Professionals® ° a . Select Jand Fitt6r Typo and Size:Select Jandy Heater Type and Size " CS2D0 3! tu>n , il,f� r ns„1.,, �?„,•ir� plOna t7•r„),, �' '�st Try r+aa. ;',,� SBieDt Caretaker In -floor Valve: and c = fro Series byZODIAC® ANSI/APSP/ICC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS Heaters Pool systems 4.4.1.1 Heater has no pilot light 4.4.1.2 Readily accessible on -off switch mounted outside of the heater 4.3.1.3 No electric resistance heating unless for inground spa with tight fitting cover with R-6 insulation, or for pool with 60% of documented pool heating from on -site solar or recovered energy. 4.3.2 Heater efficiency: gas/oil fired heater efficiency at least 78%, heat pump COP at least 4.0 ❑� 5.1.1 Pool filter pump listed in database R1 5.3.1 Pool filter pump with total horsepower 1.0 or more is multi -speed 21 Multi -speed pump controller programmed to default to the filtration flow rate when no auxiliary 5.3.3 pool loads are operating within 24 hours and programmed with temporary override capability for servicing. 5.3.4 Single -speed pump controller capable of operating pump during off-peak electric demand. 5.5.2 Pipe before pump has at least 4 diameters of straight pipe. System installed with solar, or setup for the future addition of solar heating equipment by 5.5.3 installing 18 inches of horizontal or vertical pipe after the filter and before a heater, or built-in or built-up connections, or dedicated pipe to and from the pool. 5.5.6 Directional inlets for mixing pool water. 4/4/12 ANSI/APSP/ICC-15 Standard Writing Committee Form 2 of ANSVAPSPACC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS PROJECT NAME: AND ADDRESS FORD CONTRACTOR NAME AND ADDRESS: PIPELINE POOLS & PAVERS 7705 LOCKWOOD DR FT. PIERCE, FL OWNER: FORD CONTRACTOR PHONE: DATE:11/3/2020 Dais information sneet was preparea Dy the APnP-Je Nesi iential 5wtmmmg Pool ana Spa tnergy tniciency Stanoa[a wming Lommntee orthe Association or Pool and Spa Professionals (APSP). It is not part of the American National Standard ANSI/APSP/ICC-15 2011 but is included for information only. Contractors should acquire and comply with the ANSI/APSP/ICC-15 2011 standard which can be purchased at www.apsp.org. 1. §5.2.1: Calculated pool volume a. Gallons: 7,069 ; or 1. 7,069 gallons _ b. Calculated Gallons: 300 (surface area) X 32 (overage depth) X Z48 (gal/f,43) = 7.069 2. §5.2.1: Calculated maximum filtration flow rate 2. 36 gpm _ (Pool volume _ 360 or 36gpm whichever is larger) 3. §5.2.2: Auxiliary Pool Load: lYes, No? (Enter the highest auxiliary pool load" to be powered by the swimming pool filtration pump. Do not add auxiliary 3. gpm - pool load flow rates together, only the highest is used.) 4. Calculated maximum flow rate 4. 36 gpm _ (Item 2 or item 3, whichever is larger.) S. §5.5.1: Pipe sizing: a. Minimum suction pipe diameter Sa. 1.5 inches _ (Enter the smallest pipe size from Table I with a 6 fps flow capacity the some or more than item 4.) b. Minimum suction branch pipe diameter 5b. 1.5 inches (Calculate: Item 4. 36 (gpm) a Branch Pipes 1 (quantity)=branchflow rate 36 (gpm). _ Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the same or more than the calculated suction branch flow rate.) c. Minimum return pipe diameter Sc. 1.5 inches (Enter the smallest pipe size from Table I with a 8 fps flow capacity the some or more than item 4.) _ d. Minimum return branch pipe diameter Sd. 1.5 inches (Calculate: Item 4. 36 (gpm) a Branch Pipes 1 (quantity) = branch flow rate 36 (gpm). _ Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the same or more than the calculated return branch flow rate.) 6. §5.4.1: Filter type and size: a. Filter type: (Cartridge, DE, Sand) 6a. Cartridge b. Minimum filter area 6b 96.0 s4 ft. (Calculate: item 4. 96 (gpm)?fiherfnctor 0.375 J Filter factors: Cart 'd e=0.375, Sand=15 Diatomaceous Earth=2 7. §5.4.2: Backwash valve: LJ Yes, M No? 7, 2.0 inches - (When using a backwash valve, enter result of item 5c or 2 inches whicheveris larger) Table 1 Pipe Si YS' r 2.5- r 3.6' 4• a' 0" Nominal GPM @ 6 fps 38 63 90 138 185 238 374 540 Nomnan iaPM @ 5 fps 51 84 119 184 241 317 499 720 8. Pump selection: §5.3.2.1: Pools I7,OOD gallons or less, select pump• from the database with a Curve -A gpm flow equal to item 2 or less. §5.3.2.1: Pools 17,001 gallons or more, select pump' from the database with a Curve-C gpm flow equal to item 2 or less. "Multi - speed pumps must have one speed listed that satisfies this requirement. a. Pump model b. Pump flow (§5.3.2.1, 5.3.2.2: Applicable Curve A or gpm flow listed in database) 4/4/12 ANSI/APSP/ICC-15 Standard Writing Committee Form LOT 10 E LOT 17 Block 23 g F Block 23 (OCCUPIED) I (OCCUPIED) I FlRC S00•00'00"E 125.00' nP ___- _55.00' I\ nr 11 mmm FNfPE l le N WON 4 aE11 w 22.1 OPEN MRrARPO(iT ' M C y = m ; ; DIaVEWAY � y I LOT 11 $ ezr fo.r rew 23BIOCk OE - RESID E N C E na Y (OCCUPIED) -----------O p a. '1t O c°!4 T 1 °SPiM P C � • • < 221' __________ �'�------------- .�i 'F3yni o Fwc NO0`O0'OO"E 125.00, RP ff I LOT 12 a LOT 15 Block 23 g Block 23 (OCCUPIED) in(OCCUPIED) Fort Pierce Boulevard I II LEGEND ® - SANITARY ACCESS LID 01 - SANITARY CLEANOUT CL - CENTERUNE RIGHT OF WAY CONC- CONCRETE EP - EDOE OF PAVEMENT jZr - TELEPHONE RISER FIR - FOUND 5/8- IRON ROD • - WATER METER ,DINE 25, 2018 (UNNUMBERED) A/C - AIR CONDITIONER PAD Dole o/ 51�lalura T6WAN & BaaffT'r TIP - FOUND 2" IRON PIPE DUE - IV DRAINAGE & ProPeTALUAl SurveyN ET Nappy (UNNUMBERED) UTILITY EASEMENT FlMda cn6.t to Na 6383 - OVERHEAD UTILITY LINES i - CABLE TELEVISION RISER IH Na 7M 0 - WOao Posen POLE S - PLUS OR MINUS a - MAILBOX H26 - WATER TREATMENT PAD ga, VS-FHP1.0 _ 8b. 59 gPM - 1of2 RI namw•toro. s' .._ I LL I sr� Q Yioloity Lap (Not To Basle) 0 O LEGAL DESCRIPTION: /C LOT 16, BLOCK 23, LAKEWOOD PARK UNIT THREE, according to the mop g or plat thereof, os recorded h Plat Back 10. at Page 63 through 64, of the O Public Records of St. Lude County, Florida. 0 LOT AREA: 11.250 Sq. FL; 0.26 Acres& 0 STREET ADDRESS: 77o5 Lockwood Drive. Fort Piarce, Florida 3051. a SURVEYORS' NOTES: 1. Bearings shown hereon ars based an the centedine of Lockwood DHVe as platted and le sesumed to bear N 90*00'W E. 2 Phut. dimandw. take preaedwee over ceased dimensions and di°lanwe are not to be coaled for construction and/or design purpoeae. 3. All distances and bearings are we Reid measured and are coincident with 'PLAT' and description data undoes otherwise noted. 4. This drawing to not valid without the signature and ongind roleed wool of a Florida licensed Surveyor & MODper. 5. We survey To based upon o description Nmlrshad by the dlenl. U are has been no search of ele puNie record. done by into office. 6. Properly Iles In Flood Zone •X' ou scaled lean the National Flood Insurance Program Rate Nap, Community Panel Number 1211100070 J. with an eff..U. date of Febmery 16. 2012. 7. This survey to not covered by professional Reality Insurance. 6. City water & eawor are ovalloWe in 1hM area. S. No underground utililloo ar knprovemente were located unless otherwise shown. CERTIRED 70: RICHARD FORD; HIGH TECH LENDING, INC., ISAOA/AT1MA; TREASURE COAST TITLE & ESCROW and CHICAGO TITLE INSURANCE COMPANY Dale of last Held trout 08/22/2018 ee11 -on. and ii- IItt tYeeaitu& Title 8innell Surveying, Inc. Ea 107 Abdo Cant ' °' ROM bak 933 small: wain Rods 4"El Job Na: 18-0611 anowgWE I Dais 00 28 2018 Seal. 1"-20 Shawn 1 of 1