HomeMy WebLinkAboutFord PlanDetermine Minimum System Flow Rate: (35 gpm per Skimmer) 1. Pool Volume Calculation: 300 ft' (SurfArea) x 3.15 ft (Avg. Depth) x 7.48 gaVft3= 7,069 gal 2. Determine Flow Rate: 7,069 gal / 360 min = 19.6 gpm + 0 gpm = 19.6 gpm (Volume) (Turnover Time) (Pool Flow) (Feature Flow) (System Flow) 3. Determine Pipe Sizes: Trunk Piping to be 2.5" to keep velocity at 8fps max. at 117 gpm Maximum System Flow Rate Return Piping to be 2.0" to keep velocity at 8fps max. at 82 gpm Maximum System Flow Rate System Flow Rate Must Not Exceed Flow Rate for Main Drain Cover (See Detail at Right) Pump Model: VSFHP1.65 H.P.: 1.65HP Total H.P. = H.P. x service factor. 1 H.P. or more must be 2 speed or variable speed. Filter Make: CS 200 Size: 200 Filter min. area based on 6 hr turnover flow rate (pool flow rate calculated above) Divide gpm by the following factors: Cartridge - 0.375, Sand - 15 or D.E. - 2 Time Controller Make: Intermatic Model: PE 35300 POOL RETURN PIPING POOL TRUNK PIPING - POOL EQUIPMENT 8 fps GPM Loss (fUft) E 82010 117 181 VS-FHP1.0 PERFORMANCE CURVES S tz '70 LL do a 3m pM W � 2750RRM 1000 "M 20 1730RPM 70 '.., 'd 1- 0 Q 0 10 20 30 40 30 W " 80 W 1011 110 IN 130 140 180 NO 170 11m 1W 20 FLOW GPM POOL PUMP CURVE 0.09 NOTE: SEE ATTACHED HYDRAULIC CALCULATIONS FOR ADDITIONAL DETAILS 0.07 REGARDING PUMP FLOW RATES AND TOTAL DYNAMIC HEAD CALCULATIONS. SELECTED EQUIPMENT CALCULATIONS N.T.S. GRATE TO BE ATTACHED HYDROSTATIC WITH SCREWS LINE (1-1/2") 3/4" ROCK BED (MIN 3YDS. ROCK TO STABILIZE SOIL) WELL POINT THREADED REMOVE GRATE AND WELL POINT LINE FROM PVC PIPE MAIN DRAIN, AND ATTACH AUX. PUMP LINE WHEN EMPTYING WELLPOINT N.T.S. 7r, ff 11 in 4' Safety barrier To meet code 18" 1 12" MIN. 1 12" MIN. 12" MAX. ' 12" MAX. 12" MAX. SEE TYPICAL WALL SECTION FOR REINFORCEMENT NOTE: ALL STAIRS SHALL BE UNIFORM IN HEIGHT EXCEPT FOR THE TOP AND BOTTOM RISE WHICH MAY VARY FROM THE UNIFORM HEIGHT. STAIRS DETAIL N.T.S. 4" THICK CONCRETE SLAB 6x6 - Wl ANV1.4 1:3 MAX. SLOPE WWM OR FIBERMESH OR PAVER DECK W/ EXISTING SOILS COMPACTED TO 95% MAX. T FLAT DECK WIDTH VARIES COMPACTION 6" WATERLINE TILE 4" 2-#3 BARS AT TOP • -�--- ---^- TIED TO VERT. STEEL ..- Q W Z WIDTH VARIES FROM 4" - 6" LO-- O o_ JLU J Q O NOTES: 1.) WALLS UNDER V IN HEIGHT MAYBE 4" THICK W/ #3 -- _ - Z v) 60 BARS @12" O.C.E.W. CENTERED IN CONCRETE ,• g 2.) PAVERS MAY BE SUBSTITUTED FOR CONCRETE DECK. HOWEVER, ANY FOOTER MUST BE DESIGNED BY PLASTER FINISH, OTHERS GEM COAT OR 3.) WALLS OVER 6' IN HEIGHT SHALL BE REINFORCED EQUIVALENT PER WALL OPTIONS TABLE BELOW • R 4.) THIS DECK DESIGN IS NOT INTENDED TO BE SUFFICIENT FOR SCREEN ENCLOSURE. ANY LOAD REQUIREMENTS FOR ADDITIONAL STRUCTURES SHALL BE DESIGNED BY OTHERS •: STEEL TEX. OR • • EQUIVALENT 6" #3 BARS @ 12" O.C. E.W. CENTERED IN CONCRETE TYPICAL WALL AND DECK SECTION (MAX. 6' HEIGHT) N.T.S. VERT. REINFORCEMENT MAXIMUM WALL HEIGHTS #3 BARS @ 12" O.C. N/A N/A N/A V - 6" #3 BARS @ 9" O.C. N/A N/A 6' - 6" T - 0" #3 BARS @6"O.C. 6'-6" 7'-0" 7'-6" 8'-0" #3 BARS @WO.C. 7'-6" 8'-0" 8'-6" 9'-0" REQ. WALL THICKNESS 4" THICK 5" THICK 6" THICK 8" THICK HORIZ. REINFORCEMENT #3 BARS @ 12" O.C. #3 BARS @ 12" O.C. #3 BARS @ 9" O.C. #3 BARS @ 6" O.C. T-6„ ALTERNATE WALL OPTIONS (WALL HEIGHT GREATER THAN 6') N.T.S. 20'-0" 18'-0" 1 2'-0" WATER LINE 1L__ 5'-0" 7 W 1 3 MAX. 110SLOPE MAIN DRAIN MAX. (TYP.) LOCATION ITUDINAL POOL SECTION N.T.S. Pool: Pool Area: 300 sq ft Per: 70 In ft Depth: 3'6" to 5' IA: Spa: Per: Access: West Equipment: Equipment: Filter: Jandy 200 Pump: Jandy Flo Pro Pump Model:1.65 HP VS Jet Pump: None Valves: Jandy Never lube Heater: None Salt System - None Finishes: Deck Area: 246 sq ft Pads: 1 equip. D.O.D.: 00' Risers: Turndowns:0 Sleeves: 0 - VB 2-BB 1 - UMB Interior: Standard gem finish Deck: Concrete with texture/paint Tile: (6x6) Plumbing: Skimmer:1 Drains: 1 channel Returns:3 AWL: 0 Vac Line:1 Cleaner: 0 Bubbler:2 Location: Features: Sun Shelf 5' x15" Electrical: Light: 1 LED Fiber Opt: 0 Brass: J-Box: 1w/ outlet Light mod. Motor mod: 0 Features: Pool side alarm to meet code. 4' Safety barrier to meet code. STAINLESS STEEL HANDRAIL (SAME BONDING FOR LADDER) POOL DECK CONNECT #8 BARE AWG COPPER WITH APPROVED BOND CLAMP 6" MAX. MIN. #8 BARE AWG COPPER AROUND f' PERIMETER OF POOL 18"-24" MIN. FOUR (4) CONNECTIONS (ONE CONNECT PERIMETER -` GROUND WIRE TO -• GROUND SYSTEM = EACH SIDE) W/ #8 BARE AWG COPPER W/ APPROVED CLAMPS CONNECT #8 BARE AWG COPPER WITH APPROVED " BOND CLAMP • LIGHT NICHE NOTE: BONDING PER 250.8 AND 680.26(B) OF NFPA 70, NATIONAL ELECTRICAL CODE. EQUIPOTENTIAL BONDING GRID DETAIL WASTE (RETAIN ON SITE) PUMP WITH HAIR AND LINT STRAINER (SEE ATTACHED CALCULATIONS) FILTER SYSTEM W/PRESSURE GAGE AND AIR RELEASE VALVE m a� w o0 Qa LEGEND W CHECK VALVE N 2-WAY VALVE -► FLOW DIRECTION N.T.S. MAIN RETURN LINE z m aW ar w o� o� Qa -00 0 rc zd w w z of �z h OJ Oa N nO n N POOL NOTE: PIPE SIZING TO BE DETERMINED BY HYDRAULIC CALCULATIONS PLUMBING DIAGRAM N.T.S. WP MANUAL STARTER SWITCH (TYP.) 3 -#12 WIRES IN 3/4" CONDUIT TO PUMP -► TO PUMP 2 (IF APPLICABLE) TO ELEC. SERVICE VIA WATER PROOF PANEL TO BLOWER (IF APPLICABLE) G.F.I. NO MORE THAN 20' FROM POOL TO HEATER (IF APPLICABLE) EDGE AND NOT WITHIN 10' OF POOL EDGE 3 #8 WIRES IN 1" CONDUIT JUNCTION BOX 3 -#12 WIRES IN 3/4" CONDUIT WATERLINE 18" MIN. 12V LIGHT W/ - LOW WATER CUTOFF DEVICE N. SPST TOGGLE SWITCH 12V TRANS. 1" NON -CORROSIVE CONDUIT - POOL WALL AND DECK (SEE TYPICAL SECTION) ELECTRICAL DIAGRAM N.T.S. 6'-9' 0'-3' 3' ANGLE OF REPOSE = 1.5:1 8" THICK WALL W/ #3 1 BARS @ 6' O.C.E.W. 6" THICK WALL W/#3 REBAR @ 12" O.C.E.W. 5" THICK WALL W/#3 REBAR @ 12" O.C.E.W. NOTE: SEE TYPICAL WALL SECTION WHEN WALL FALLS OUTSIDE OF THE ANGLE OF REPOSE ANGLE OF REPOSE N.T.S. - POOL DECK WATER LINE 18" BEAM SWIMOUT DEPTH DETAIL N.T.S. GENERAL NOTES 1. ALL FLOORS AND WALLS OF POOL TO BE CONSTRUCTED USING PNEUMATICALLY APPLIED CONCRETE WITH 28 DAY STRENGTH OF 2500 PSI. 2. REINFORCING STEEL SHALL CONFORM TO A.S.T.M. 615 GRADE 60 3. PIPING TO BE SCHEDULE 40 PVC BEARING NSF APPROVAL. 4. POOLS TO BE CONSTRUCTED ONLY ON CLEAN SAND OR ROCK. SOILS IN FINAL BACKFILL SHALL BE COMPACTED TO PROVIDE A MINIMUM BEARING CAPACITY OF 1000 PSF. ALL UNSUITABLE MATERIALS SHALL BE REMOVED AND REPLACED WITH CLEAN SAND PLACED AND COMPACTED IN 12" LIFTS. 5. ALL BACKFILL SHALL BE PLACED WITH CARE IN ORDER TO ENSURE THAT PLUMBING IS NOT DISTURBED. ALL FILL SHALL BE CLEAN SAND PLACED IN 12" LIFTS AND COMPACTED TO 98%OF MAXIMUM DENSITY. 6. THE CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS IN ORDER TO PROTECT EXISTING STRUCTURES AFFECTED BY THE CONSTRUCTION. THE DESIGN ENGINEER ACCEPTS NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURES. 7. ENGINEERING PLOT PLANS WERE NOT PREPARED FROM LEGAL SURVEYS OF THE EXISTING LOT AND RESIDENCE. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND ESTABLISH LOT LINES WHEN NECESSARY. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY LAYOUT SHOWN AND ALL DIMENSIONS PRIOR TO CONSTRUCTION. AS SUCH, THE ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACKS. 8. CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES ON SITE AND SHALL MAINTAIN MINIMUM SEPARATIONS AS REQUIRED BY LOCAL REGULATIONS. GENERALLY, ELECTRICAL LINES SHALL BE A MINIMUM OF 10 FEET FROM OPEN WATER. 9. ALL UNSCREENED POOLS SHALL HAVE A FENCE A MINIMUM OF 4 FEET IN HEIGHT WITH SELF-LOCKING GATES. 10. WHERE POOLS ABUT OR ARE PLACED NEAR SEAWALLS OR BULKHEADS SPECIAL CARE SHOULD BE TAKEN. NOTIFY ENGINEER OF THIS CONDITION FOR ANALYSIS AND RE -DESIGN IF NECESSARY. 11. PATIO DESIGN MAY BE NOTED TO BE COMPLETED BY OTHERS. WHEN NOTED, ANY DETAILS REFERRING TO PATIO DESIGN ARE NOT APPLICABLE. THE TYPICAL WALL SECTIONS OF POOL ARE NOT APPLICABLE TO PAVEMENT DESIGN. 12. VACUUM LINE SHALL INCLUDE A SPRING LOADED SELF CLOSING COVER. 13. THE SWIMMING POOL HAS BEEN DESIGNED TO BE COMPLIANT WITH THE 2017 FLORIDA BUILDING CODE 6TH EDITION, AS WELL AS THE 2014 NATIONAL ELECTRIC CODE, ANSI/APSP-7, AND SHALL BE ANSI 15 COMPLIANT. 14. BASE MATERIAL THICKNESS MUST BE 125% OF CONCRETE FASTENER EMBEDMENT. 15. HOMEOWNER MUST BE AWARE OF THE POSSIBILITY OF EROSION AND SHALL BE RESPONSIBLE FOR MAINTENANCE IN ORDER TO PREVENT FAILURE. 16. WATER VELOCITY MAXIMUM 8 FT/SEC AS PER FBC 2017-R4501.6.3 17, POOL BARRIER TO COMPLY WITH FBC 2017-R4501.17 18. SKIMMERS TO COMPLY WITH FBC 2017-450111.2 19. EQUIPMENT FOUNDATION CONCRETE SLAB, MIN. 3.5" THICK, POUR IN PLACE. 20. WATER HEATING EQUIPMENT TO COMPLY WITH FBC 2017-114501 21. ALL DECK AND SLAB CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 P.S.I. IN 28 DAYS UNLESS OTHERWISE NOTED. 2014 NEC POOL PUMP ENERGY EFFICIENCY REQUIREMENTS REQUIREMENTS APPLY TO EXISTING POOLI DOESNT APPLY TO O p REPLACEMENTS/ADDITIONS AND NEW COMMERCIAL POOLS N CONSTRUCTION w a IF IS THE PUMP MOTOR USED TO FILTER WATER? �g5 NQ CANNOT BE SPLIT -PHASE, SHADED DOESNT APPLY TO POLE OR CAPACITOR CIRCULATION WITHOUT START -INDUCTION TYPES FILTRATION IS THE TOTAL HORESPOWER ONE OR LARGER? TOTAL HP = PUMP HP x SERVICE FACTOR a4� NQ ALSO FOLLOW THESE REQUIREMENTS: SINGLE SPPED PUMP - PUMP AND PUMP MOTORS MUST BE TWO OR MORE SPEEDS. PERMITTED. ADDITIONAL - CONTROLS NED TO BE CAPABLE OF OPERATING AT A REQUIREMENTS MAY APPLY MINIMUM OF TWO SPEEDS. CONTINUE ON. - DEFAULT CIRCULATION MUST BE THE RESIDENTIAL FILTRATION SPEED. THE HIGHER SPEED OVERRIDE IS NOT TO EXCEED ONE NORMAL CYCLE OR 24 HOURS, WHICHEVER IS LESS. - SOLAR POOL HEATING SYSTEMS ARE PERMITTED TO RUN AT HIGHER SPEEDS DURING PERIODS OF USABLE HEAT GAIN. IS THIS NEW CONSTRUCTION? ADDITIONAL REQUIREMENTS PER APSP-15:. NO ADDITIONAL - SIZE THE PUMP BASED ON: REQUIREMENTS ARE IN - POOL GALLONS / 360 MIN. AND SELECTING PUMP FROM PLACE DATABASE WITH CURVE A OR C LISTED FLOWRATE EQUAL TO OR LESS THAN CIRCULATED FILTRATION FLOWRATE. - A TIME SWITCH MUST BE INSTALLED TO ALLOW POOL OWNERS TO RUN THE POOL FILTRATION PUMP ONLY DURING THE OFF-PEAK PERIOD AND FOR THE MINIMUM TIME NECESSARY TO MAINTAIN THE WATER IN THE CONDITION REQUIRED BY APPLICABLE PUBLIC HEALTH STANDARDS. - FILTERS MUST HAVE A MINIMUM AREA BASED ON THE 6 HOUR TURNOVER FLOW RATE. - POOL GAL. / 360 MIN. = FLOW RATE (IN GPM) - DIVIDE GPM BY A NUMBER SHOWN TO FIND THE FILTER'S MIN. SQUARE FOOTAGE. (CARTRIDGE = .375, SAND =15, DE = 2) - MIN. DIAMETER OF BACKWASH VALVES MUST BE TWO INCHES OR THE DIAMETER OF THE RETURN PIPE WHICHEVER IS GREATER. - SWEEP ELBOWS ARE RECOMMENDED. - (REMEMBER: RESIZE PIPING SO VELOCITY AT MAX FLOW DOES NOT EXCEED 8 FPS IN THE SUCTION LINE AND 6 FPS IN THE SUCTION LINE, AND ALSO MEETS VGB/ANSI-7 ENTRAPMENT AVOIDANCE REQUIREMENTS.) PLUG PORTS NOT BEING USED INTERIOR POOL FINISH OPTIONAL SINGLE CONNECTION OR HYDROSTATIC VALVE FRAME / MUD -RING -4* GRAVEL EARTH SINGLE PIPE CONNECTION ON ANY SHOTCRETE/GUNNITE TO PUMP OF THREE P RTS. 1-1/2".2", -1/2' 3" OR GREATER PIPE CUSTOM MOLDED PRODUCTS 32" CHANNEL DRAIN NOTE: 2.5" (POOL) CONNECTION ON VGB-2009 COMPLIANT - MODEL: CMP 25506-32X THIS INSTALLATION NOTE: THE MAXIMUM FLOW RATING FOR THIS SUCTION FITTING AS CONFIGURED WITH OUTER PORTS PLUGGED AND CENTER PORT OPEN IS 200 GPM (FLOOR) WHEN USING 2.5" PLUMBING AND 184 GPM WHEN USING 2" PLUMBING. CHANNEL DRAIN INSTALLATION DETAIL N.T.S. SAFETY NOTES 1. NO DIVING BOARD OR DIVING IS ALLOWED IN ANY POOL WITH A DEPTH LESS THAN 8'-8" AND SPECIFICALLY DESIGNED FOR DIVING. THIS POOL DOES NOT CONFORM TO THESE REQUIREMENTS AND NO DIVING SHALL BE PERMITTED 2. THIS POOL TO BE EQUIPPED WITH CHILD SAFETY FENCE AROUND THE PERIMETER OF THE POOL OR ALARMS AT THE ENTRANCES TO THE POOL (ONE TO BE CHECKED). INOTE: LAYOUT PROVIDED BY CONTRACTOR POOL LAYOUT SCALE: 1/4" = 1