HomeMy WebLinkAboutEngineering Architectonic Inc
RECEVED
December 15, 2020
DEC 1 51010
Saint Lucie County Building Department Permitting Department
Attn: Roof Permit Plan Review St. Lucie county
2300 Virginia Avenue
Ft. Pierce, FL 34982
Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure
located at 6505 North Blvd., Saint Lucie County, Florida
Manufacturer: Metal Sales Manufacturing Corporation
Profiles: 26 Ga. 5V Crimp, FL# 14645.4 R3
Code: FBC 2017; Section R 905.10
Wind Speed: 160 MPH; Ultimate Design Wind Speeds
Exposure: C
Mean Roof Height: 20' Maximum
Pitch: 5/12 Minimum
Required Design Pressure: Zonel: -24.0 Zone 2: -40.0 Zone 3: -60.0
Maximum Uplift Pressure: -74.8 PSF @ fastener spacing 16" o.c. (at panel ends 6"o.c. across panel
width &at intermediate 12" o.c. across panel width) Fastener shall be
sufficient length to penetrate through the deck a min. of 3/8"
Roof Decking: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c.
in the field and @ 4" o.c.at edges.
The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building
Code, and the Manufacturer's recommendations.
File COPY
PY
of F� REVIEWED FOR
c�• °
CODE COMPLIANCE
,�p•.. .:S'ia
e tyjs#mitt d ST. LUCIE COUNTY
_ BOCC I1�L5J1,U
" a I Seal •���
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1