Loading...
HomeMy WebLinkAboutEngineering Architectonic Inc RECEVED December 15, 2020 DEC 1 51010 Saint Lucie County Building Department Permitting Department Attn: Roof Permit Plan Review St. Lucie county 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at 6505 North Blvd., Saint Lucie County, Florida Manufacturer: Metal Sales Manufacturing Corporation Profiles: 26 Ga. 5V Crimp, FL# 14645.4 R3 Code: FBC 2017; Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: C Mean Roof Height: 20' Maximum Pitch: 5/12 Minimum Required Design Pressure: Zonel: -24.0 Zone 2: -40.0 Zone 3: -60.0 Maximum Uplift Pressure: -74.8 PSF @ fastener spacing 16" o.c. (at panel ends 6"o.c. across panel width &at intermediate 12" o.c. across panel width) Fastener shall be sufficient length to penetrate through the deck a min. of 3/8" Roof Decking: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c. in the field and @ 4" o.c.at edges. The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. File COPY PY of F� REVIEWED FOR c�• ° CODE COMPLIANCE ,�p•.. .:S'ia e tyjs#mitt d ST. LUCIE COUNTY _ BOCC I1�L5J1,U " a I Seal •��� 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1