Loading...
HomeMy WebLinkAboutWeis DP LetterAdvanced Architecture & Planning LLC Architect & Planning 4929 S. Indian River Drive Ft. Pierce, FL 34982 (772)631-5709 Applied Wind Pressures Certification: November 2, 2020 Bill Laprade Glass Professionals, Stuart, Florida Cell: 772-745-3459 Project: 9900 S Ocean Dr. Apartment #301 (4th Floor, Corner Suite) Jensen Beach FL 34957 Dear Mr. Laprade: For the above address, the (5) replaced PGT Industries, impact sliding glass doors, Series 5570/2770 and (1) single hung, Series 5500, the minimum required wind pressures below are based on FBC 2017 wind load calculations. The applied wind pressures are as follows per the proposed replacement glazed unit for Exposure D, 40 feet in height: (NOA: 20-0429.05 and 20-0401,03 respectfully): Unit: Dimensions: Wind Zone: Applied Wind Pressure: SGD (1) 141.5”x96” 5 +47.1 / -57.1psf; SGD (1) 106”x96” 5 +47.4 / -57.5psf; SGD (1) 93.0”x96” 5 +49.0 / -58.1psf; SGD (2) 69.0”x96” 5 +48.5 / -59.2psf; SH (1) 52”x62” 5 +51.5 / -67.8psf; In reviewing respective NOA for the above sliding glass doors and single hung window, the calculated respective design pressures are less than the respective allowable pressures on their NOA’s, and as such is acceptable to this office. If you have any questions, please contact me at any time. Thank you, Raymond Chladny, B.arch.Sc., M.arch, AIA, NCARB, Lic.#: AR-0017475