HomeMy WebLinkAboutNotice of Acceptance MIAMI•QADE MIAMI-DADE COUNTY '
�' PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION AtunoD alan7 •iS T(786)315-2590 F(786)315.2599
NOTICE OF ACCEPTANCE (NOA) aoawr,edao 6arInlU-ad www.miamidade.eov/economy
Mule-Hide Products Co.,Inc. 010, 9 1330
1195 Prince Hall Drive y�(2 '
Beloit,WI 53511 43N3D3t1
REVIEWED FOR
SCOPE: CODE COMPLIA CE
This NOA is being issued under the applicable rules and re�c�t�n�the tevction materials. The
documentation submitted has been reviewed and accepted aa�Q�tff o HH net Control Section to be
used in Miami Dade County and other areas where allowed by the AutaQWng Jurisdiction(AH V�p I
Z (0a�d
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section .
(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails ] ccepted manner, tke
manufacturer will incur the expense of such testing and the AHJ may immediateiy rex ;or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements •
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Mule-Hide Self-Adhered Roof System over Wood Decks
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following •
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
•
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done 0
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA#19-0508.04 and consists of pages 1 through 29. 0
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 20-0902.19
Expiration Date: 10/11/22
Approval Date: 10/22/20 •
Page 1 of 29
ROOFING ASSEMBLY APPROVAL
Cateeorv: Roofing
Sub-Cate¢orv: Modified Bitumen
Materials SBS/APP/TPO
Deck Type: Wood
Maximum Desien Pressure -112.5 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
• TABLE 1
Test Product
Product Dimensions Specification Description
G2 Base Sheet 108' x 36" ASTM D 4601, Asphalt-coated fiberglass reinforced base sheet
Type II
•--Nail Base 65' 2"x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced base
Type I sheet.
SA Base Sheet 66' 8"x 3' 33/8" ASTM D 6163, Self-adhered, fiberglass reinforced, SBS modified
Type I bitumen membrane with a self-adhering back face and
a smooth top surface.
SA Base Sheet FR 66' 8"x 3' 3-3/8" ASTM D 6163, Self-adhered, fire-rated, fiberglass reinforced, SBS
• Type I modified bitumen membrane with a self-adhering back
face and a smooth top surface.
SA-SBS Cap Sheet 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered, fiberglass reinforced, SBS modified
Type I bitumen membrane with a self-adhering back face and
• a granule top surface.
SA-SBS Cap Sheet FR 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered, fire-rated,polyester reinforced, SBS
Type I modified bitumen membrane with a self-adhering back
face and a granule top surface.
SA-SBS KoolCap® 32' 10"x 3' 33/e" ASTM D 6164, Self-adhered, fiberglass reinforced, SBS modified
Type I bitumen membrane with a self-adhering back face and
• a granule top surface.
SA-SBS KoolCap® 32' 10"x 3' 3 3/s" ASTM D 6164, Self-adhered, fire-rated,fiberglass reinforced, SBS
FR Type I modified bitumen membrane with a self-adhering back
face and a granule top surface.
APP Torch Base/Cap 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified
bitumen membrane with a bum off polyethylene back
face and a smooth or sanded top surface.
APP Torch S 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified
bitumen membrane with a burn off polyethylene back
face and a smooth or sanded top surface.
SA-APP Cap Sheet 32' 10"x 3' 33/s" ASTM D 6222, Self-adhered,polyester reinforced,APP modified
Type I bitumen membrane with a self-adhering back face and
a granule top surface.
MIAM4DADE COUNTY
NOA No.:20-0902.19
II Expiration Date: 10/11/22
Approval Date: 10/22/20
Page 2 of 29
> s
SA-APP Cap Sheet FR 32' 10"x 3' 3}/s" ASTM D 6222, Self-adhered, fire-rated,polyester reinforced,APP
Type I modified bitumen membrane with a self-adhering back
face and a granule top surface.
APP Torch Base 65' 8"x 3' 3 3/s" ASTM D 6509, APP modified asphalt coated fiberglass reinforced base
Premier Type I sheet.
APPROVED INSULATIONS: -
TABLE 2
Product Name Product Description Manufacturer
(With Current NOA)
Mule-Hide Poly ISO 1 Polyisocyanurate foam insulation Polyglass USA, Inc.
Poly ISO 2 Polyisocyanurate foam insulation Polyglass USA, Inc.
ACFoam-II Polyisocyanurate foam insulation Atlas Roofing Corp
ACFoam-III Polyisocyanurate foam insulation Atlas Roofing Corp
Structodek High Density Fiberboard Roof Wood fiber insulation board Blue Ridge Fiberboard,Inc.
Insulation
DensDeck,DensDeck Prime Gypsum insulation board Georgia-Pacific Gypsum LLC
H-Shield Polyisocyanurate foam insulation Hunter Panels, a division of
Carlisle Construction
Materials, LLC
H-Shield CG Polyisocyanurate/perlite composite insulation Hunter Panels, a division of
Carlisle Construction
Materials, LLC -
ENRGY-3 Polyisocyanurate foam insulation Johns Manville Corp.
Fesco Board Expanded mineral fiber Johns Manville Corp.
Multi-Max FA-3 Polyisocyanurate foam insulation Rmax Operating,LLC.
SECUROCK Gypsum-Fiber Roof Board Fiber reinforced coverboard United States Gypsum `
Corporation
APPROVED FASTENERS:
TABLE 3
Fastener Product Product Manufacturer
Number Name Description Dimensions (With Current NOA)
1. Dekfast DF-#12-PH3 Insulation fastener for wood, steel SFS Group USA,Ine.
and concrete decks
2. Dekfast DF-#14-PH3 Insulation fastener for wood, steel Various SFS Group USA, Inc.
and concrete decks
3. Dekfast DF-#15-PH3 Insulation fastener for wood, steel. Various SFS Group USA,Inc.
and concrete decks
4. Dekfast PLT-H-2-7/8 Galvalume hex stress plate. 2 7/8"x SFS Group USA,Inc.
3 1/47,
MaADBCotlNTY NOA No.: 20-0902.19
MiAM
A Expiration Date: 10/11/22
Approval Date: 10/22/20
Page 3 of 29
i APPROVED FASTENERS:
TABLE 3
Fastener Product Product Manufacturer
• Number Name Description Dimensions (With Current NOA)
5. #14 Roofgrip Insulation and membrane fastener Various OMG,Inc.
6. Flat Bottom Metal Plate A2-SS aluminized steel plate 3" square OMG,Inc.
7. Mule-Hide HDP Fastener Insulation fastener for steel and Mule-Hide Products
wood decks Co.,Inc.
8. Mule-Hide 3"Metal Insulation Round Galvalume AZ50 steel plate 3.23 round Mule-Hide Products
Plate 3"round Co., Inc.
9. #12 Standard Roofgrip Insulation fastener for wood, steel Various OMG, Inc.
and concrete decks
10. OMG 3 in.Ribbed Galvalume Galvalume stress plate. 3"round OMG, Inc.
Plate (Flat)
11. OMG 3" Galvalume Steel Plate Galvalume stress plate. 3"round OMG,Inc.
12. Dekfast PLT-R-3 Galvalume stress plate. 3"round SFS Group USA,Inc.
13. Millennium One-Step A two component,low rise, H.B.Fuller Company
Foamable Adhesive polyurethane foam adhesive
14. Millennium One Step Green A two component, low rise, H.B.Fuller Company
• Foamable Insulation Adhesive polyurethane foam adhesive
15. Millennium PG-1 Pump Grade A two component, low rise, H.B.Fuller Company
Adhesive polyurethane foam adhesive
16. PG 100 A penetrating solution of solvent 1,3,5, 50,55 Polyglass USA,Inc.
and a blend of selected asphalts used gal,tube or 17
to promote adhesion. oz. spray can
• 17. PG 350 A fibered rubberized adhesive _ 1,3, 5, 50, 55 Polyglass USA,Inc..
designed for use with modified gal. or tube
bitumen membranes.
18. PG 400 A thick, fibered,rubberized flashing 1, 3, 5, 50, 55 Polyglass USA,Inc.
cement for use in dry or damp gal. or tube
conditions.
19. PG 425 A thick,fibered,rubberized flashing - 1, 3, 5, 50, 55 Polyglass USA,Inc.
cement for use in dry or damp gal. or tube
conditions.
20: PG 450 A thick,fibered,rubberized flashing 1, 3, 5, 50, 55 Polyglass USA,Inc.
cement. gal. or tube
21. PG 500 A thick,fibered,rubberized flashing 1, 3, 5, 50, 55 Polyglass USA,Inc.
cement for use with modified gal. or tube
bitumen membranes.
NOA No.:20-0902.19
MIAMMADECo1}A[TY Expiration Date: 10/11/22
C� ' ' ' Approval Date: 10/22/20
Page 4 of 29
Y
APPROVED FASTENERS:
TABLE 3
Fastener Product Product Manufacturer .
Number Name Description Dimensions (With Current NOA)
22. POLYPLUS 35 A fibered rubberized adhesive 1, 3, 5, 50, 55 Polyglass USA,Inc.
designed for use with modified gal. or tube
bitumen membranes.
23. POLYPLUS 45 A.thick;fibered,rubberized flashing 1, 3; 5, 50, 55- Polyglass USA, Inc. a
cement. gal. or tube
24. POLYPLUS 50 A thick,fibered,rubberized flashing 1, 3, 5, 50, 55 Polyglass USA,Inc:
cement for use with modified gal, or tube
bitumen membranes.
25. WB-3000 A low-VOC,water-based acrylic 5.gallon pail Polyglass USA,Inc.
primer to enhance adhesion of self.-
adhered membranes.
APPROVED SURFACING
TABLE 4
Chosen components must be applied according to manufacturer's application instructions. ,
Number Product Product Application Specification Manufacturer
Name Description Rate
1. Gravel To be installed in a flood.coat '4001bs/sq N/A Generic
of approved asphalt at 60•lbs/sq
2. Slag To be installed in a flood coat 300 lbs/sq N/A Generic
of approved asphalt at 601bs/sq •
3. KM Acryl 15 A premium white or tinted. 1-1'%2 gal/sq ASTM D6083 Polyglass USA,
elastomeric acrylic based roof Inc. '
..coating(water-based). A-
polyester fabric may be used
for reinforcement with this
coating.
4. KM Acryl 15 QS A premium white or tinted 1-1'/2 gaUsq ASTM D6083 Polyglass USA, •
quick setting,elastomeric Inc.
acrylic based roof coating
(water-based)..A polyester
fabric maybe used for
reinforcement with this coating.
5. ,KM Acryl 25 A premium white or tinted ' 1-1'/z gaUsq ASTM D6083 •Polyglass USA, •
elastomeric acrylic based roof Inc."
coating(water-based). A
polyester fabric may be-used
for reinforcement with this
coating,
¢ NOA No.: 20-090219
� , Expiration Date: 10/11/22
Approval Date: 10/22/20
`t.: Page 5 of 29
•
APPROVED SURFACING:
TABLE 4
Chosen components must be applied according to manufacturer's application instructions.
Number Product Product Application Specification Manufacturer
UU S U
Name Description Rate
• 6. KM Acryl 25 QS A premium white or tinted 1-1%2 gal/sq ASTM D6083 Polyglass USA,
quick setting, elastomeric Inc.
acrylic based roof coating
(water-based). A polyester
fabric may be used for
reinforcement with this coating.
• 7. KM-PS#220 A single component, solvent, 1.25 gaUsq ASTM D6694 Polyglass USA,
white or tinted, silicone Inc.
coating.
8. KM-PS #250 A high
e rad premium
p g g solids, 1.25 gaUsq ASTM D6694 Polyglass USA,
white or tinted, single Inc.
component,moisture cure,
•
fluid applied silicone coating
9. PG 300 An asphalt cutback fibered roof 1'Y2-2 gaUsq ASTM D4479 Polyglass USA, -
coating. May be applied by Inc.
brush or spray equipment to
rejuvenate aged BUR
10. PG 600 Non-fibered aluminum roof 'h-1 gaUsq ASTM D2824 Polyglass USA,
coating. Type I Inc.
• 11. PG 650 Fibered aluminum roof coating. 1'Y2-2 gal/s_q ASTM D2824 Polyglass USA, -
Type III Inc.
12. PG 700 A premium white or tinted 1-1'/2 aUs ASTM D6083 Polyglass USA
g q Yg
elastomeric acrylic based roof Inc.
coating(water-based). A
polyester fabric may be used
• for reinforcement with this
coating.
13. PG 700 QS A premium white or tinted 1-1'/z gaUsq ASTM D6083 Polyglass USA,
quick setting, elastomeric Inc.
acrylic based roof coating
(water-based). A polyester
a fabric may be used for
reinforcement with this coating.
14. PG 800 An asphalt based,non-fibered 3 gaUsq in two ASTM D 1227 Polyglass USA,
clay emulsion coats Inc.
15. PolyBrite 70 A premium white or tinted 1-1'/z gaUsq ASTM D6083 Polyglass USA,
elastomeric acrylic based roof Inc.
• coating(water-based). A
polyester fabric may be used
for reinforcement with this
coating.
NOA No.:20-0902.19
MtAMF�A�$COU� Expiration Date: 10/11/22
° Approval Date: 10/22/20
Page 6 of 20
APPROVED SURFACING: e
TABLE 4
Chosen components must be applied according to manufacturer's application instructions.
Number Product Product Application Specification Manufacturer
Name Description Rate
16. PolyBrite 70 QS' A premium white or tinted 1-1%2 gal/sq ASTM D6083 Polyglass USA,
quick setting, elastomeric Inc.
acrylic based roof coating
(water-based). A polyester '
fabric may be used for
reinforcement with this coating.
17. PolyBrite 90 A premium grade high solids, 1.25 gal/sq ASTM D6694 Polyglass USA,
white or tinted, single Inc.
component,moisture cure,
fluid applied silicone coating.
18. PolyBrite 95 A single component,white or 1.25 gal/sq ASTM D6694 Polyglass USA,
tinted,solvent,moisture cure Inc.
silicone coating.
19. POLYPLUS 60 Non-fibered aluminum roof ''/z-1 gal/sq ASTM D2824 Polyglass USA,
coating. Type I Inc.
20. POLYPLUS 65 Fibered aluminum roof coating. 1'/z-2 gal/sq ASTM D2824 Polyglass USA,
Type III Inc.
NOA No.: 20-0902.19
MIAMMADECOUNMW Expiration Date: 10/11/22
Approval Date: 10/22/20
Page 7 of 29
EVIDENCE SUBMITTED:
Test Agency Test Name/Report Report No. Date
Factory Mutual Research 4470 2W7A7.AM 08.04.94
Corporation 4450 2D5A9.AM 06.22.99
4470 3000857 01.12.00
4470 3004091 01.12.00
4470 3001334 02.15.00
4470 3014692 08.05.03
4450 3014751 08.27.03
4450 3019317 06.30.04
4470 3024311 11.01.06
4470 3012321 07.29.07
4470 3036182 07.31.09
4470 RR202591 10.22.15
Trinity ERD TAS 114 11752.09.99-1 02.09.00 =
TAS 114 11751.05.03 05.30.03
TAS 117(B)-ASTM D903 020841.06.04 06.02.04
TAS 114 02762.03.05 03.30.05
TAS 114 02764.09.05 09.09.05
TAS 114 P1739.01.07 01.23.07
• TAS 114 P1734.07.06-R1 02.27.07
TAS 117(B)-ASTM D6862 C8500SC.11.07 11.30.07
TAS 114 &FM 4470 P7860SC.11.07 11.30.07
TAS 114(D)—ASTM D 1876 P 10070.10.08 10.09.08
TAS 114(H) P13760.09.09 09.10.09
FM 4470 &TAS 114 P33970.03.11 03.15.11
ASTM D6163 /ASTM D 4601 P33960.03.11 03.15.11
ASTM D6163 P37590.03.13-2-R1 02.05.13
ASTM D6164 P37590.03.13-3A 03.06.13
TAS 114 P1738.02.07-R2 04.29.13
TAS 114&TAS 117 (B) 11757.04.01-1-R1 04.30.13
ASTM D6509 P37590.03.13-1-R1 06.26.13
ASTM D6222 P37590.03.13-5-R1 07.01.13
ASTM D6164 P37590.07.13-1 07.02.13
TAS 114 &FM 4474 P41630.08.13 08.06.13
ASTM D4601 /TAS 117 P45940.09.13 09.04.13
ASTM D6222 P37590.09.13 09.12.13
ASTM D4601 /TAS 117 P45970.05.14 05.12.14
ASTM D6162 SC5170.05.15 05.08.15
ASTM D6162 SC5170.12.15-1 12.29.15
o TAS 114&FM 4474 PLYG-SC8905.05.16-1 05.17.16
TAS 114&TAS 117 (B) 11757.12.00-1-R2 04.05.17
PRI Construction Materials ASTM D6222 PUSA-061-02-02 01.28.08
Technologies ASTM D6163 PUSA-064-02-02 02.27.08
ASTM D6222 PUSA-062-02-02 12.04.08
ASTM D6694 PUSA-134-02-01 05.16.14
ASTM D6694 PUSA-135-02-01 05.16.14
TAS 117(B) PUSA-202-02-01 05.08.17
FM 4470 &TAS 114 PUSA-202-02-02 05.23.17
NOA No.:20-0902.19
M"MADECOU T1'Y Expiration Date: 10/11/22
• ' ' Approval Date: 10/22/20
Page 8 of 29
APPROVED ASSEMBLIES: . .
Membrane Type: SBS/APP
Deck Type 1I: Wood,Insulafed
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24"span_ s with#8 wood screws at 6 o.c.. 4
System Type A(1): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is
subsequently adhered to insulation.
All General and System Limitations apply.
Anchor Sheet:- One ply of Nail Base,APP Torch Base/Cap*, APP Torch S* or G2 Base Sheet, fastened to the
deck as described below:
with.OMG fasteners and Flat Bottom Metal Plates.
Fastening#1: Attach base sheet using'11 ga. annular ring shank and 1-5/8"diameter'tin caps spaced 8"o.c. in
a 4"lap and 8"o.c. in three equally spaced staggered rows in the center of the sheet.
Fastening#2: Attach base sheet using OMG#14 Roofgrip fasteners and Flat Bottom Metal Plates,Dekfast •
DF-#14-PH3 with. Dekfast PLT-H-2-7/8 plates or Mule-Hide HDP Fasteners with Mule-Hide
3"Metal Insulation Plates, spaced 12"o.c. in a 4"lap and 12"o.c. in two equally spaced
staggered rows in the center of the sheet.
One or more of the following _
Base Insulation Laver(Optional) Insulation Fasteners Fastener •
Table 3 Densi /ft'.
Poly ISO 2,H-Shield,Mule-Hide Poly ISO 1,ACFoam-II,ACFoam-I1I,H-Shield,Multi-Max FA-3,ENRGY-3
Minimum 1.51'thick N/A N/A
Note: All insulation shall be adhered-to the anchor sheet in full mopping of approved asP roved hot halt within the EVT
range and at a rate of 20-40 lbs/100 ft'. Please refer to Roofing Application Standard RAS 117 for insulation •
attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved
top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top ,
layer placed with the polyisocyanurate side facing down.
Top Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft'
DensDeck,DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board •
Minimum 1/"thick N/A N/A
Note: Apply top layer of insulation in a full mopping of any approved mopping asphalt within the EVT range and
at a rate of 20-40 lbs/100 ft . Please refer to Roofing Application 'Standard RAS 117 for insulation attachment.
= Insulation listed as Base.Layer only shall be used only as base layers with a second layer of approved top layer
insulation installed as the final membrane substrate. Composite insulation panels,may be used as a top layer placed •
with the polyisocyanurate side facing down.
Primer: Apply WB-3000 at 1 gal.per 300 sq. ft. ,
(Optional)
Mu WDADECO NOA,No.: 20-0902.19 •
, Expiration Date:'10/11/22
Approval Date: 10/22/20
Page 9 of 29
I -
Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered.
Ply Sheet: One or more plies of SA Base Sheet, SA Base Sheet FR, self-adhered.
• (Optional)
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR,SA-APP Cap Sheet, SA-APP Cap
Sheet FR; SA-SBS.KoolCap® or SA-SBS KoolCap®FR, self-adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -52.5 psf, (See general limitation#7.)
•
•
m _
•
NOA No.:20-0902.19 "
Muu�Fr�aoECou Expiration Date: 10/11/22
Approval Date: 10/22/20
Page 10 of 29
0
Membrane Type: SBS/APP
Deck Type II: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank,- fastened at'24",spans with#8 wood screws at 6" o.c. ® .
System Type A(2): All insulation layers,are adhered to a mechanically attached anchor sheet. Membrane is
subsequently adhered to insulation.
All General and System Limitations apply.
Anchor Sheet: One ply of Nail Base,Nail Base P, APP Torch Base/Cap,APP Torch S, G2 Base Sheet,
fastened to the deck as described below:
Fastening: Attach base sheet using OMG#14 Roofgrip fasteners and Flat Bottom Metal Plates spaced 12"
o.c. in a 4"lap and 12"o.c. in two-equally spaced staggered rows in-the center of the sheet.
One or more of the following
Base Insulation Laver(Optional) Insulation Fasteners Fastener -
Table 3 Densi /ft2.
Poly ISO 2,H-Shield,Mule-Hide Poly ISO 1,ACFoam-II,ACFoam-III;H-Shield,Multi-Max FA-3,ENRGY-3
Minimum 1" thick N/A N/A
Top Insulation Laver Insulation Fasteners Fastener
Table 3 Densi /ft2
DensDeck,DensDeck Prime,'SECUROCK Gypsum-Fiber Roof Board
Minimum'/a"thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT
=range and at a rate of 20-40 lbs/100-Al. Please refer to Roofing Application Standard RAS 117 for insulation
attachment.' Insulation listed as base layer only shall be used only as base layers with a second layer of approved •
top layer insulation installed as the'final membrane substrate.-Composite insulation panels may be used as a top
layer placed with the polyisocyanurate side facing down.
Primer: ;Apply WB-3000 at,1 gal,per 300 sq. ft. .
(Optional)
Base Sheet: One ply of SA Base Sheet or SA Base'Sheet'FR,'self-adhered.
Ply Sheet: One or more plies of SA Base Sheet.or SA Base.Sheet FR; self-adhered.
(Optional)--
Membrane:- One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap®or.SA-SBS KoolCap®FR, self-adhered.
Surfacing.' Install one of the approved surfacin products listed in Table 4.to g obtain desired coating or
g pp g P •
(Optional) required fire classification.
Maximum Design
Pressure: -60.0 psf; (See general limitation#7:)
•
UPNMTY NOA No.: 20-0902.1�9
° Q Expiration Date: 10/11/22
Approval Date: 10/22/20
Page 11 of 29
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Peck Description: 19/32" or greater plywood or wood plank, fastened at 24"spans with 8d common nails at 4" o.c.
or#8 wood screws at 6" o.c.
• System Type A(3): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is
subsequently'adhered to insulation.
All General and System Limitations apply.
Anchor Sheet: One ply of G2 Base Sheet fastened to the deck as described below:
• Fastening: Attach base sheet using 11 ga. Annular ring shank and 1-5/8"diameter tin caps spaced 8"o.c.
in a 4"lap and 8"o.c. in three equally spaced staggered rows in the center of the sheet:
One of more of the following:
Base Insulation Laver(Optional) Insulation Fasteners Fastener
Table 3 Density/ft2
• Poly ISO 2,H-Shield,Mule-Hide Poly ISO,1,ACFoam-II;ACFoam-III,H-Shield,Multi-Max FA-3,ENRGY-3
Minimum 1"thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within,the EVT
range and at a rate of 20-40 lbs/100 ft . Please refer to Roofing Application Standard RAS 117 for insulation
attachment. Insulation listed as base layer only shall be used only.as base layers with a second layer of approved
• top layer insulation'installed as the final membrane substrate. Composite insulation panels may be used,as a top
layer placed with the polyisocyanurate side facing down.
Top Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ftz
Dens Deck,Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board
• Minimum V4"thick N/A N/A
Note: Apply top layer of insulation in a full mopping of any approved mopping asphalt within the EVT range and
at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Insulation listed as Base Layer only shall be used only as base layers with a,second layer of approved top layer
insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer
placed with the polyisocyanurate side,facing down.
Primer: Apply WB-3000 at 1 gal.per 300 sq. ft.
(Optional)
Base Sheet: One ply of SA Base-Sheet or SA Base Sheet FR, self-adhered.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
0 (Optional)
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet IiR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, self-adhered.
NOA No.:20-0902.19
0 MTAMFOADEGO' Expiration Date: 10/11/22
Approval Date: 10/12/20
Page 12 of 29
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification. •
Maximum Design
Pressure: -52:5 psf; (See general limitation#7.)
• a
M MADECov NOA No.:20-0902.19
... Expiration Date: 10/11/22
Approval Date: 10/22/20
Page 13 of 29 •
• Membrane Type: SBS/APP
Deck Type 1I: Wood,Insulated
Deck Description: 19/32" or greater plywood or wood plank fastened at 24" spans with#8 wood screws at 6" o.c.
System Type A(4): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is
• subsequently adhered to insulation.
• All General and System Limitations apply.
Anchor Sheet: One ply of Nail Base or Nail Base P,.fastened as below:
Fastening: 12 ga. Annular ring shank nails and 1-5/8"tin-caps attached 6"o.c. in 4"lap and 6"o.c. in
four equally spaced staggered rows.
• Base Insulation Laver Insulation Fasteners- Fastener
Table 3 Densitv/ft2
ACFoam-II,Poly ISO 2,ACFoam-III,H-Shield,Mule-Hide Poly ISO 1,H-Shield CG,Multi-Max FA-3,
ENRGY 3
Minimum 1"thick N/A N/A.
• Note: All insulation shall be adhered to the anchor sheet with Millennium One-Step Foamable Adhesive, _
Millennium One Step Green Foamable Insulation Adhesive or Millennium PG-1 Pump Grade Adhesive applied ed
over rows of tin-caps in continuous rows 7" o.c. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer
of approved top layer insulation installed as the final membrane substrate. Composite insulation panels maybe
used as a top layer placed with the polyisocyanurate side facing down.
• Primer: Apply WB-3000 at 1 gal.per 300 sq. ft.
(Optional)
Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
(Optional)
•
Membrane:
One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR,_SA-APP Ca Sheet SA-APP Ca
P � p
Sheet FR, SA-SBS KoolCapO or SA-SBS KoolCapO FR,self-adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
• Maximum Design
g
Pressure: -60.0 psf; (See general limitation#7.)
M2AMK ADE C=j .
NOA No.:20-0902.19
•� Expiration Date: 10/11/22
Approval Date: 10/22/20
• Page 14 of 29
Membrane Type: SBS/APP
Deck Type 1I: Wood,Insulated
Deck Description: Min. 19/32"plywood(15/32" for re-roof)or wood plank, fastened at 24"spans with 8d common
nails at 6"o.c.
System Type C(1): All layers'of insulation are mechanically attached to roof deck. Membranes subsequently
adhered to insulation.
All General and System Limitations apply.
One or more of the following
Base Insulation Laver ' Insulation Fasteners Fastener
Table 3 Density/ft'
Any approved Polyisocyanurate listed in Table 2 '
Minimum 1.0"thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels
listed are minimum.sizes and dimensions; if larger panels are used, the number of fasteners shall be increased
maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation •
attachment.
Top Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft'
SECUROCK Gypsum-Fiber Roof Board
Minimum'/"thick 2 with 4 or 12; 5 with 6, 10 1:2 ft' •
or 11; 7 with 8
DensDeck Prime
Minimum 1/4"thick 2 with 4; 5 with 6 or 11; 7 1:2 ft2
with 8
Note:All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation •
panels.listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Primer: Apply WB-3000 at 1 gal.per 300 sq. ft.
= (Optional)
Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered. •
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
(Optional)
Membrane: One ply of SA-SBS Cap Sheet FR, SA-APP Cap Sheet FR or SA-SBS KoolCap®FR, self-
adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or • .
(Optional) required fire classification.
Maximum Design
Pressure: -45.0 psf; (See General limitation#7.)
NOA No.: 20-0902.19
MteuManeCovtm Expiration'Date: 10/11/22 ;• .
Approval Date: 10/22/20
Page 15 of 2,9
Membrane Type: SBS/APP
Deck Type 11: Wood,Insulated
• Deck Description: 19/3211
or greater plywood or wood plank, fastened at 24"spans with 8d common nails or wood
screws at 4"o.c.
of insulation are mechanical) attached to roof deck.Membranes subsequently
System Type C(2): All layersy q Y
adhered to insulation.
All General and System Limitations apply.
• One or more of the following
Base Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft2
Any approved Polyisocyanurate listed in Table 2
Minimum 1.5" thick N/A N/A
•
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased
maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation
attachment.
Top Insulation Laver Insulation Fasteners Fastener
• Table 3 Density/ft2
Structodek High Density Fiberboard Roof Insulation
Minimum'/Z"thick 2 with 4 1:1.33 ftz .
DensDeck
Minimum '/4" thick 2 with 4 1:1.33 ft2
• Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation -
panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Primer: Apply WB-3000 at 1 gal.per 300 sq. ft. to DensDeck prior to application of self-adhered base
0 (Optional) sheets.
Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR,self-adhered.
(Optional)
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
® Sheet FR, SA-SBS KoolCap®or SA-SBS KoolCap@ FR, self-adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -67.5 psf; (See General limitation#7.)
NOA No.: 20-0902.19
M1AM{-DADECOUNW Expiration Date: 10/11/22
Approval Date: 10/22/20
Page 16 of 29
Membrane Type: SBS/APP
Deck Type 1I: Wood,Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24"spans with 8d common nails at 4" o.c. °
System Type C(3): All layers of insulation are mechanically attached to roof deck.Membranes subsequently
adhered to insulation.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Layer Insulation Fasteners Fastener .
Table 3 Density/ft'
Any approved Polyisocyanurate listed in Table 2
Minimum 1.5" thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased
maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation
attachment.
Top Insulation Laver Insulation Fasteners Fastener
Table 3 Density/ft'
Structodek high Density Fiberboard Roof Insulation
Minimum %11 thick 2 with 4 1:1.33 ft2
DensDeck
Minimum '/"thick 2 with 4 1:1.33 ft'
Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation
panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 fQr
insulation attachment.
Primer: Apply WB-3000 at 1 gal.per 300 sq. ft. to DensDeck prior to application of self-adhered base
(Optional) sheets. -
Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
(Optional)
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA=SBS KoolCap®or SA-SBS KoolCap®FR, self-adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -67.5 psf; (See General limitation#7.)
NOA No.: 20-0902.19 •
Mu►MFOADECOLiNTY Expiration Date: 10/11/22
Approval Date: 10/22/20
Page 17 of 29
•
Membrane Type: SBS/APP
Deck Type 1I: Wood,Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24"spans with wood screws at 6" o.c.
• System Type C(4): All layers of insulation are mechanically attached to roof deck. Membranes subsequently
adhered to insulation.
I
All General and System Limitations apply.
i
One or more of the following:
• Insulation Layer Insulation Fasteners Fastener
Table 3 Density/fe
ENRGY 3,H-Shield,Mule-Hide Poly ISO 1,ACFoam-II,Poly ISO 2
Minimum 1.5" thick 2 with 4; 7 with 8 1:1.33 ft2
Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation
• panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for -
insulation attachment.
Primer: Apply WB-3000 at 1 gal.per 300 sq. ft.
(Optional)
Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR,self-adhered.
•
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
(Optional)
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, self-adhered.
• Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -92.5 psf; (See General limitation#7.)
a
s
NOA No.: 20-0902.19
® M"K ADB COUNTY Expiration Date: 10/11/22
Approval Date: 10/22/20
Page 18 of 29
- Membrane Type: SBS/APP
Deck Type 1I: Wood,Insulated
Deck Description:' 19/32° or greater plywood or wood plank, fastened at 24" spans with#8 wood screws at 6"o.c..
System Type D(1): All insulation is loosed laid with preliminary attachment to deck. Base sheet is subsequently
mechanically fastened through insulation to the roof deck. Membranes subsequently adhered.
-All General and System Limitations apply.
One or more layers of the following: ,.
Base Insulation Laver Insulation Fasteners Fastener
x Table 3 Density/ft'
' 1
Any approved Polyisocyanurate listed in Table 2
Minimum 1"thick N/A N/A'
Q .
Top Insulation Layer.(Optional) Insulation Fasteners Fastener
Table 3 Density/ft"
Fesco Board
Minimum'/"thick N/A N/A,
Structodek High Density Fiberboard Roof Insulation
Minimum 1/2".thick N/A N/A
DensDeck,DensDeck Prime,SECUROCK Gypsum-Fiber Roof-Board
Minimum V411 thick N/A N/A
Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a
„ minimum application rate of,two fasteners per board;for insulation boards having no dimension greater than 4 ft.,
and four fasteners for any insulation board having no,dimension greater,than 8 ft.
Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below:
Fastening: Attach base sheet using OMG#14 Roofgrip fasteners and Flat Bottom Metal Plates,Dekfast
DF-#14-PH3 with Dekfast PLT-H-2-7/8 plates, or Mule-Hide HDP Fasteners with Mule-Hide
3"Metal Insulation Plates, spaced 12"o.c. in a 4"lap and 12" o.c. in two equally spaced
staggered rows in the center of the'sheet.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
_ . Sheet FR, SA=SBS-KoolCap®or SA-SBS KoolCap®FR, self-adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -52.5 psf; (See General limitation#7.)
CMIAM��DAVECOMWM 'NOA No.: 20-0902.19
Expiration Date: 10/11/22
Approval Date: 10/22/20
Page 19 of 29
• Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19/3211 or greater.plywood or wood plank, fastened at 24"spans with#8 wood screws at 6". o.c.
System Type D(2): All insulation is loosed laid with preliminary attachment to deck. Base sheet is subsequently
mechanically fastened through insulation to the roof deck. Membranes subsequently adhered.
• All General and System Limitations apply.
One or more layers of the following:
Base Insulation Laver Insulation Fasteners Fastener
Table 3 Densi /ft2
• Any approved Polyisocyanurate listed in Table 2
Minimum 1"thick N/A N/A
Top Insulation Laver(Optional) Insulation Fasteners Fastener
Table 3 Density/ft'
Fesco Board
• Minimum 1/"thick N/A N/A
Structodek High Density Fiberboard Roof Insulation
Minimum 1/z" thick N/A N/A
VensDeck,DensDeck Prime,SECUROCK Gypsum-Fiber Roof Board
•
Minimum 1/411 thick N/A N/A
Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a -
minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft.,
and four fasteners for any insulation board having no dimension greater than 8 ft.
Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below:
•
Fastening: Attach base sheet using OMG#14 Roofgrip fasteners and Flat Bottom Metal Plates spaced 12"
o.c. in a 4"lap and 12"o.c. in two equally spaced staggered rows in the center of the sheet.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, , self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR,SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap®or SA=SBS KoolCapS FR, self-adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -60.0 psf; (See General limitation#7.)
NOA No.:20-0902.19
MMMMAne COUNW
• : Expiration Date: 10/11/22
e Approval Date: 10/22/20
Page 20 of 29
e
Membrane Type: SBS/APP
Deck Type 1: Wood,Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24"spans with 8d common nails at 4" o.c.
or#8 wood screws at 6" o.c.
System Type E(1): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Nail Base or Nail Base P fastened to the deck as described below:
Fastening: Attach base sheet using 11 ga. annular ring shank nails and 1-5/8"diameter tin caps spaced 8"
o.c. in a 4"lap and 8"o.c. in three equally spaced staggered rows in the center of the sheet.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR,self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap®FR, self-adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification. '
Maximum Design
Pressure: -52.5 psf; (See General limitation#7.).
NOA'No.: 20-0902.19
Expiration MtArtF°a°EcoucuTY ration Date: 10/11/22
■III ....�
Approval Date: 10/22/20 •
Page 21 of 29
c
Membrane Type: SBS/APP
Deck Type 1: Wood,Non-Insulated
• Deck Description: 19/32" or greater plywood or wood plank, fastened at 24"spans with 8d ring shank nails at 6" o.c.
at edges and intermediate supports.
System Type E(2): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
• Base Sheet: One ply of Nail Base or APP Torch Base Premier fastened to the deck as described below:
Fastening: Attach base sheet using 11 ga. annular grooved shank and 1"diameter caps spaced 6" o.c. in a
3"lap and 6"o.c. in four equally spaced staggered center rows.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet
•
FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, self-adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -52.5 psf; (See General Limitation#7)
•
•
•
MIAMFDADE COUNTY
NOA No.:20-0902.19
Expiration Date: 16/11/22
Approval Date: 10/22/20
Page 22 of 29
IN
I - "
Membrane Type: SBS/APP
Deck Type 1: Wood,Non-insulated
Deck Description: "/32" or greater plywood or wood plank, fastened at 24"spans with 8d common nails at 4"o.c.
or#8 wood screws at 6"o.c
System Type E(3): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Nail Base or Nail Base P fastened to the deck as described below:
Fastening: Attach base sheet using OMG#14 Roofgrip fasteners and Flat Bottom Metal Plates spaced 12" `
o.c. in a 4"lap and 12"o.c. in two equally spaced staggered rows in the center of the sheet.
Ply Sheet: One or more plies of SA Base Sheet, SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet
FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR,self-adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -52.5 psf; (See General Limitation#7)
NOA No.: 20-0902.19
nwnwnnecourrrr Expiration Date: 10/11/22
Approval Date: 10/22/2U
Page 23 of 29
•
Membrane Type: SBS/APP
Deck Type 1: Wood,Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24"spans with 8d common nails at 4" o.c.
• or#8 wood screws at 6"o.c.
System Type E(4): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Nail Base or Nail Base P fastened to the deck as described below:
• Fastening: Attach base sheet using 11 ga. annular ring shank nails and 1-5/8"diameter tin caps spaced 8"
o.c. in a 4"lap and 8"o.c. in three equally spaced staggered rows in the center of the sheet.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet
•
FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, self-adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design
Pressure: -52.5 psf; (See General Limitation#7)
•
•
0
NOA No.:20-0902.19
Expiration Date: 10/11/22
MIAMMADE COUNTY
Approval Date: 10/22/20
Page 24 of 29
Membrane Type: SBS/APP -
Deck Type 1: Wood,Non-Insulated Q
Deck Description: 19/3211 or greater plywood or wood plank,fastened at 24"spans with#8 wood screws at 6"o.c.
System Type E(5): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Nail Base or APP Torch Base Premier fastened to the deck as described below:
Fastening: Attach base sheet using OMG#14 Roofgrip fasteners and Flat Bottom Metal Plates, Dekfast
DF-#14-PH3 with Dekfast PLT-H-2-7/8, or Mule-Hide HDP Fasteners with Mule-Hide 3"
Metal Insulation Plates, spaced 12" o.c. in a 4" lap and 12"o.c. in two equally spaced
staggered rows in the center of the sheet.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, self-adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
•
Maximum Design
Pressure: -60.0 psf; (See General limitation#7.).
M araFuewe cou�t,Y NOA No.: 20-0902.19
r
I- ...� U� Expiration Date: 10/11/22
Approval Date: 10/22/20
Page 25 of 29
Membrane Type: SBS/APP
Deck Type 1: Wood,Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened to supports spaced 24"o.c. and to blocking
members spaced 48"o.c. with TruFast TP#1 Ox2-7/8"screws spaced 6"o.c.
System Type E(6): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
•
All General and System Limitations apply.
Base Sheet: One ply of Nail Base or Nail Base P fastened to the deck as described below:
Fastening: Attach base sheet using 12 ga, annular ring shank nails and 1-5/8"diameter tin caps spaced 4"
o.c. in a 4"lap and 4"o.c. in four equally spaced staggered rows in the center of the sheet.
•
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR,self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet
FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, self-adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coaling or
• (Optional) required fire classification.
Maximum Design
Pressure: -97.5 psf, (See General Limitation#7)
MIAM4DADE COUNTY NOA No.: 20-0902.19
Expiration Date: 10/11/22
Approval Date: 10/22/20
Page 26 of 29
Membrane Type: SBS/APP
Deck Type 1: Wood,Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened to supports spaced 24"o.c. and to blocking
members spaced 48" o.c.with#100"wood screws spaced 6"o.c.
System Type E(7): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Nail Base or Nail Base P fastened to the deck as described below:
Fastening: Attach base sheet using 12 ga.ring shank nails and tin caps.spaced 4"o.c. in a 4"lap and 4" o.c.
in four equally spaced staggered rows in the center of the sheet.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet
FR, SA-SBS KoolCap or SA-SBS KoolCap®FR, self-adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
•
Maximum Design -97.5 psf;With SA Base Sheet or SA Base Sheet FR(See General limitation#7.)
Pressure: -112.5 psf; With all other base sheet options (See General limitation#7.)
NOA No.:20-0902.19 .
M"FuaoE counrnr Expiration Date: 10/11/22
Approval Date: 10/22/20
Page 27 of 29
Membrane Type: SBS/APP
• Deck Type 1: Wood,Non-Insulated
Deck Description: "/32" or greater plywood or wood plank, fastened to supports spaced 24" o.c.with#80"wood
screws spaced 6"o.c.
System Type E(8): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
• Base Sheet: One ply of Nail Base or Nail Base P fastened to the deck as described below:
Fastening: Attach base sheet using 12 ga. annular ring shanked nails and 1-5/8"tin-caps 6"o.c. in 4"lap
and 6"o.c. in four equally spaced staggered rows. Tin-caps are primed with PG 100.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
•
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet
FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, self-adhered.
Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
(Optional) required fire classification.
Maximum Design -97.5 psf; With SA Base Sheet or SA Base Sheet FR(See General limitation#7.)
Pressure: -112.5 psf; With all other base sheet options (See General-limitation#7.)
:S
0
NOA No.:20-0902.19
MtAM DARE caurrrr Expiration Date: 10/11/22
Approval Date: 10/22/20
Page 28 of 29
,6
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product
Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the
top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
u
shall be 4'x 4'maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped.If no recovery board is used the base sheet shall be applied using spot mopping
with approved asphalt, 12" diameter circles,24" o.c.; or strip mopped 8"ribbons in three rows, one at each side lap .
and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not
= acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of
either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf., as .
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchoribase sheet or membrane attachment is based on a minimum
= fastener resistance value in conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less than that required, as determined by the Building Official, a revised fastener •
spacing,prepared, signed and scaled by a Florida registered Professional Engineer,Registered Architect, or
Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal
resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing
Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application
Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, •
Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this
NOA, General Limitation#9 will not be applicable.)
8. All attachment and sizing of perimeter nailers,metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e.perimeters, extended comers and corners). (When this limitation is specifically •
referred within this NOA, General Limitation#7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 20-0902.19
MIAMMADECOUNTY Expiration Date: 10/11/22 •
Approval Date: 10/22/20
Page 29 of 29
a �� x 16