Loading...
HomeMy WebLinkAboutPLANS - EVANS RESIDENCE - 11-11-20203'-0"x6'-8"1'-5"x2'-0" SH@ 4'-11" A.F.F.3'-0"x4'-0" SH@ 2'-11" A.F.F.3'-0"x4'-0" SH@ 2'-11" A.F.F.4'-3"x4'-0" SH @ 2'-11" A.F.F.4'-3"x4'-0" SH@ 2'-11" A.F.F.4'-3"x4'-0" SH@ 2'-11" A.F.F.4'-3"x4'-0" SH @ 2'-11" A.F.F.3'-0"x6'-8"3'-0"x3'-0" SH @ 2'-11" A.F.F. 3'-0"x6'-8"2'-8"x6'-8"2'-8"x6'-8" 2'-8"x6'-8" 2'-6"x7'-0" 9'-0"x6'-10" OHGD2'-8"x6'-8"GFI WP GFI WP SSS 56'-1"24'-1"9'-4"21'-3"36'-1" 14'-7 1/2"5'-8"14'-4 1/2"47'-9"8'-4"14'-2"11'-5"20'-9"13'-3"14'-10"8'-0" 12'-5"14'-5" SHEET TITLE : PROJECT TITLE : COMMISSION # : REVISIONS : FILE NAME : REV #DATE DESCRIPTION OFFICE INFORMATION DRAWN BY : CHECKED BY : ISSUE DATE : RSL 10/20/2020 2023 EVANS RESIDENCE FIRE REPAIR 5911 Birch Dr, Fort Pierce, FL 34982, USA PID: 3402-609-0592-000-8 - -- CONSULTANTS : 22062 CONCHA AVE. BOCA RATON, FL. 33428 ROBERT S. LEWIS REG # : AR91402 PH : 1.772.408.6963 FAX : Ancient tech email it. No one faxes anymore EMAIL: rlewis@biarch.com AA26001089 10-20-2020A R CH I T ECT URE DATE:$7+.&+0)+&'#5 A0.1 TITLE PAGE - RSL C:\PROJ\1200\1201 OWNER:NATHAN J., AND JENNIFER EVANS ADDRESS:5911 BIRCH DRIVE FORT PIERCE, FL. 34982 PROPERTY INFORMATION: PROP ID: 3402-609-0592-000-8 ZONING: RS-4 COUNT Use: 0100 LEGAL:INDIAN RIVER ESTATES UNIT 08 BLK 66 LOT 22 (MAP 34/ 11S ) PROPERTY APPRAISER INFORMATION CONSTRUCTION TYPE TYPE I: BUILDING ELEMENTS ARE NON COMBUSTIBLE TYPE II: EXTERIOR WALLS NON COMBUSTIBLE | FRTW NON BEARING PARTITIONS CORRIDORS SERVING NO MORE THAN 30 OCCUPANTS 1 HR FRTW TYPE III: EXTERIOR WALLS NON COMBUSTIBLE | INTERIOR - ANY TYPE IV: HEAVY TIMBER TYPE V: EXTERIOR & INTERIOR ANY MATERIAL PERMITTED BY CODE A-PROTECTED B-UNPROTECTED SPRINKLED UNSPRINKLED CLIMATE ZONE: 1 MIAMI/DADE/BOWARD 2 FL 3 4 5 FBC: ENERGY : C301.1 CHAPT. 6 RISK CATEGORY I - LOW HAZARD ( AGRICULTURAL, TEMPORARY, MINOR STORAGE ) II - BUILDINGS NOT I, III, OR IV III - SUBSTANTIAL HAZARD ( ASSEMBLY +300, SCHOOLS +250, I2 +250, I3, ANY OCCUPANCY WITH +5000, PUBLIC UTILITIES NOT IN CAT IV, BUILDINGS CONTAINING TOXIC SUBSTANCES. IV - I2 W/ SURGERY & TREATMENT, PUBLIC SERVICES & UTILITIES, SHELTERS, HIGHLY TOXIC MATERIALS, AVIATION CONTROL TOWERS, NATL. DEF. BUILDINGS, WATER STORAGE AND PUMP STATIONS. CHAPT. 1604 SCOPE: THIS IS AN EXISTING RESIDENCE THAT SUFFERED A FIRE. THIS SET OF DOCUMENTS ARE REPAIRS TO THE RESIDENCE DUE TO THE FIRE. THE REPAIR WILL CONSIST OF : NEW PARTITIONS AND REPAIRED PARTITIONS, (1) REPLACEMENT WINDOW (2) NEW WINDOWS, ENCLOSING A WINDOW, REPLACEMENT OF THE FRONT DOOR AND ADDING A BACK DOOR. NEW ELECTRIC FROM THE METER INTO THE HOUSE, REINFORCEMENT OF THE EXISTING EXTERIOR WALLS AND GABLE ENDS, INSULATION, DRYWALL, AND FIXTURES. MECHANICAL - COMPLETE REPLACEMENT PLUMBING - REPLACEMENT OF FIXTURES IN THE SAME LOCATIONS. ELECTRIC - NEW ELECTRICAL. EXISTING SERVICE. BUILDING / PROJECT DATA BUILDING AREA: PROJECT AREA: TOTAL AFTER CONSTRUCTION: 1559 SF U/A, 328 SF GARAGE 123 SF OUTDOOR COVERED PATIO 1,957 SF TOTAL 1,640 SF UNDER AIR ( 81 SF INCREASE) 1957 SF NO CHANGE TO THE TOTAL AREA OF THE RESIDENCE. PART OF THE EXISTING COVERED ENTRY IS BECOMING PART OF THE KITCHEN. SHEET INDEX A0.1 - TITLE PAGE - EXISTING PLAN A0.2 - RESIDENTIAL NOTES A1.5 - DEMOLITION PLAN A2.0 - FLOOR PLAN - DOOR AND WINDOW SCHEDULE A3.0 - BUILDING ELEVATIONS AND SECTIONS A9.0 - DETAILS E1 - ELECTRICAL PLAN, RISER AND PANEL SCHEDULE E2 - ELECTRICAL M1 - MECHANICAL NOTES AND EQUIPMENT M2 - MECHANICAL PLAN M3 - MECHANICAL DETAILS P1 - PLUMBING PLAN C1 - COMMENTS, RESPONSES, AND REVISIONS LOAD SCHEDULE LIVE DEAD PART'N TOTAL GROUND FLOOR 40 50 10 100 SECOND FLOOR 40 15 10 65 ROOF + LIMIT STOR.30+20 30 0 80 1607.5Partition loads. In buildings where partition locations are subject to change, provisions for partition weight shall be made, unless the specified live load is 80 psf or greater. The partition load shall be not less than a uniformly distributed live load of 15 psf (0.72 kN/m2). ULTIMATE WIND SPEED = 170 M.P.H. RISK CATEGORY = II EXPOSURE CATEGORY 1609.4.3 B MEAN ROOF >30 FT. W/ SURFACE ROUGHNESS B UPWIND 1500 FT MEAN ROOF <30 FT. W/ SURFACE ROUGHNESS B UPWIND 2600 FT C WHERE EXPOSURES B, AND D DO NOT APPLY D WHERE SURFACE ROUGHNESS D EXTENDS 5000 FT UPWIND INLAND FROM THE SHORELINE 600 FT OR (20 x BUILDING HEIGHT) SURFACE ROUGHNESS 1609.2 B URBAN, SUBURBAN, WOODED W/ NUMEROUS OBSTRUCTIONS C OPEN TERRAIN W/ SCATTERED OBSTRUCTIONS LESS THAN 30FT. 100 FT HORIZONTALLY FROM AN AREA (C or D) 100' W x 600' D UPWIND INCLUDES FLAT OPEN COUNTRY & GRASS LANDS EXTENDING 1500 FT. D FLAT UNOBSTRUCTED AREAS AND WATER SURFACES. INTERNAL PRESSURE = +/- 0.18 ROOF DEAD LOAD FOR WIND DESIGN TAKEN AT 10 P.S.F. NOTE: THIS STRUCTURE IS DESIGNED IN ACCORDANCE WITH CHAPTER 16 OF THE FLORIDA BUILDING CODE. DESIGN PRESSURES FOR EXTERIOR DOORS AND WINDOWS ARE NOTED ON THE ELEVATIONS. WINDOW AND DOOR MANUFACTURERS SHALL MULTIPLY THE GIVEN DESIGN PRESSURES BY THE APPROPRIATE FACTORS TO OBTAIN TEST PRESSURES. RISK CATEGORY 1604.5 I Buildings and other structures that represent a low hazard to human life. AGRICULTURE, TEMPORARY II THOSE NOT I, III, IV, OR V III Buildings and other structures that represent a substantial hazard to human life BUILDINGS > 300 OCC., E >250 OCC., E GREATER THAN 12TH > 250 OCC., I2 > 50 RESIDENTS, I3, UTILITIES IV Buildings and other structures designated as essential facilities 1 A0.1 SCALE: APROX 1" = 100' LOCATION MAP B BB B B B BB 150' W x 600' D SURFACE ROUGHNESS IN ACCORDANCE W/ 1609.4.1 APPROXIMATELY 7,000FT TO THE INTERCOASTAL APPROXIMATELY 19,000 FT TO THE BEACH APPROXIMATELY 19,000 FT TO THE POWER PLANT DESIGN LOADS WITHIN CATEGORIES MAY BE HIGHER THAN THE MINIMUM ADOPTED BY THE COUNTY OR MUNICIPALITY NOTED. THIS IS THE DESIGN INTENT OF THE PROFESSIONAL. BUILDING CLASSIFICATION: A1 - FIXED SEATING A2 - FOOD AND/OR DRINKS A3 - WORSHIP, RECREATION A4 - INDOOR SPORTS A5 - STADIUMS BLEACHERS B - BUSINESS E - EDUCATIONAL F1 - FACTORY (MODERATE HAZARD) F2 - FACTORY ( LOW HAZARD) F3 - FACTORY ( SPECIAL PURPOSE H - HIGH HAZARD NEW STRUCTURE/ OCCUPANCY I1 - INSTITUTIONAL HOUSING 16+ I2 - INSTITUTIONAL MEDICAL CARE I3 - INSTITUTIONAL JAILS M - MERCANTILE R1 - RESIDENTIAL ( TRANSIENT ) R2 - RESIDENTIAL ( 2+ DWELLINGS) R3 - RESIDENTIAL ( PERMANENT ) R4 - RESIDENTIAL CARE >16 PERSONS S1 - STORAGE ( MODERATE HAZARD ) S2 - STORAGE ( LOW HAZARD ) U - UTILITY / MISCELLANEOUS D - DAYCARE EXISTING STRUCTURE/ OCCUPANCY CHAPT. 3 CLASSIFICATION - E.B. REPAIRS: REPLACEMENT OF DAMAGED MATERIALS FOR MAINTENANCE ALTERATIONS LEVEL 1: REPLACEMENT OF MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES FOR THE SAME PURPOSE. LEVEL 2: THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM OR INSTALLATION OF ADDITIONAL EQUIPMENT. LESS THAN 50 PERCENT OF THE BUILDING AREA. LEVEL 3: ALTERATIONS WHERE THE WORK AREA EXCEEDS 50 PERCENT OF THE AGGREGATE AREA OF THE BUILDING WITHIN ANY 12 MO. PERIOD. CHANGE OF OCCUPANCY: FOLLOW PROVISIONS OF CHAPT 9. ADDITIONS:FOLLOW PROVISIONS OF CHAPTER 10. CHAPT. 4 CURRENT CODES BUILDING 6th EDITION (2017) FLORIDA BUILDING CODE RESIDENTIAL 6th EDITION (2017) FLORIDA RESIDENTIAL CODE EXISTING 6th EDITION (2017) FLORIDA EXISTING BUILDING CODE ACCESSIBILITY 6th EDITION (2017) FLORIDA ACCESSIBILITY CODE ENERGY 6th EDITION (2017) FLORIDA ENERGY CONSERVATION CODE PLUMBING 6th EDITION (2017) FLORIDA PLUMBING CODE MECHANICAL 6th EDITION (2017) FLORIDA MECHANICAL CODE FUEL GAS 6th EDITION (2017) FLORIDA FUEL GAS CODE ELECTRICAL 2014 NATIONAL ELECTRIC CODE FIRE 6th EDITION (2017) FLORIDA FIRE PREVENTION CODE 2015 NFPA 101 LIFE SAFETY CODE 2015 NFPA 1, FIRE CODE FIRE :Review and approval by the AHJ shall not relieve the applicant of the responsibility of compliance with this Code per NFPA -1: 1.14.1 STRUCTURAL ASCE STANDARD 7-10 FIRE ALARM FIRE ALARM AND SIGNALING CODE NFPA 72 FLOOD ZONE FBC -1612.1: Chapter 5 of ASCE 7 and with ASCE 24. CLASSIFICATION:ZONE X BASED ON FEMA FLOOD MAP SERVICE CENTER SEARCH BY ADDRESS. 5911 BIRCH DRIVE 2 A0.1 SCALE: APROX 1" = 300' EXISTING RESIDENCE G:\BuildingIdeas\2000\2023-5911BirchDr-Cason-EvansRes-Fire\05-SD\X-base-Evans-201016.dwg, 10/20/2020 3:39:47 PM, Robert S Lewis P.A. AR91402 (561) 441-8126 rlewis@biarch.com SHEET TITLE : PROJECT TITLE : COMMISSION # : REVISIONS : FILE NAME : REV #DATE DESCRIPTION OFFICE INFORMATION DRAWN BY : CHECKED BY : ISSUE DATE : RSL 10/20/2020 2023 EVANS RESIDENCE FIRE REPAIR 5911 Birch Dr, Fort Pierce, FL 34982, USA PID: 3402-609-0592-000-8 - -- CONSULTANTS : 22062 CONCHA AVE. BOCA RATON, FL. 33428 ROBERT S. LEWIS REG # : AR91402 PH : 1.772.408.6963 FAX : Ancient tech email it. No one faxes anymore EMAIL: rlewis@biarch.com AA26001089 10-20-2020A R CH I T ECT URE DATE:$7+.&+0)+&'#5 A0.2 GENERAL RESIDENTIAL NOTES - RSL C:\PROJ\1200\1201 THIS PROJECT IS A "REMODEL OF" JOB. THIS CONTRACTOR SHALL VISIT THE JOB SITE TO DETERMINE THE EXTENT OF WORK INVOLVED WITH THE CHANGES SHOWN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND ALLOW FOR ANY CHANGES THAT MAY BE MADE DURING THE COMPLETION OF THE JOB. CONTRACTOR SHALL INFORM ARCHITECT/ENGINEER IMMEDIATELY OF ANY DISCREPANCIES BETWEEN ACTUAL EXISTING CONDITIONS AND INFORMATION INDICATED AS "EXISTING" ON PLANS WHICH WILL IMPEDE THE COMPLETION OF THIS JOB PRIOR TO BEGINNING OF WORK. ANY ELECTRICAL WORK THAT MAY HAVE TO BE DONE TO COMPLETE ANY ALTERATIONS SHOWN ON PLAN SHALL BE INCLUDED IN THIS CONTRACT WITH NO ADDITIONAL CHARGE TO THE OWNER AFTER CONTRACTS ARE LET. SPECIAL NOTE SDJ LF S TA VP HE B S S 4 D S S K R S 3 S GFI C GFI UC GFI WP DC HN C FB L F G:\BuildingIdeas\2000\2023-5911BirchDr-Cason-EvansRes-Fire\05-SD\X-base-Evans-201016.dwg, 10/20/2020 3:39:52 PM, Robert S Lewis P.A. AR91402 (561) 441-8126 rlewis@biarch.com 3'-0"x6'-8"1'-5"x2'-0" SH@ 4'-11" A.F.F.3'-0"x4'-0" SH@ 2'-11" A.F.F.3'-0"x4'-0" SH@ 2'-11" A.F.F.4'-3"x4'-0" SH @ 2'-11" A.F.F.4'-3"x4'-0" SH@ 2'-11" A.F.F.4'-3"x4'-0" SH@ 2'-11" A.F.F.4'-3"x4'-0" SH @ 2'-11" A.F.F.3'-0"x6'-8"3'-0"x3'-0" SH @ 2'-11" A.F.F. 3'-0"x6'-8"2'-8"x6'-8"2'-8"x6'-8" 2'-8"x6'-8" 2'-6"x7'-0" 9'-0"x6'-10" OHGD2'-8"x6'-8"56'-1"24'-1"9'-4"21'-3"36'-1" 14'-7 1/2"5'-8"14'-4 1/2"47'-9"8'-4"14'-2"11'-5"20'-9"13'-3"14'-10"8'-0" 12'-5"14'-5" 6"14'-4" 1'-0"3'-4"3'-6"3'-4"CONTRACTOR TO ROUGHEN EXISTING SLAB AND ADD STO CR 245 BONDING AGENT PRIOR TO POUR. CONCRETE FINISH TO MATCH EXISTING SLAB HEIGHT. GARAGE KITCHEN DINING RM. LIVING RM. BEDROOM #3 BEDROOM #2 BEDROOM #1 W.I.C. #1 BATH #1 BATH #2 EXISTING SLAB UNTAMPERED FILL 6 MIL VAPOR BARRIER NEW FILL TERMITE TREATMENT AND TAMPED COMPACTION NEW PIPING OR CONDUIT WHERE APPLICABLE #4 REBAR 16" LONG STAGGERED AT 16" O.C. 4" EPOXY EMBEDMENT INTO EXISTING SLAB EXISTING SLAB EA. SIDE NEW FIBER REINFORCED CONC.1'-4"SHEET TITLE : PROJECT TITLE : COMMISSION # : REVISIONS : FILE NAME : REV #DATE DESCRIPTION OFFICE INFORMATION DRAWN BY : CHECKED BY : ISSUE DATE : RSL 10/20/2020 2023 EVANS RESIDENCE FIRE REPAIR 5911 Birch Dr, Fort Pierce, FL 34982, USA PID: 3402-609-0592-000-8 - -- CONSULTANTS : 22062 CONCHA AVE. BOCA RATON, FL. 33428 ROBERT S. LEWIS REG # : AR91402 PH : 1.772.408.6963 FAX : Ancient tech email it. No one faxes anymore EMAIL: rlewis@biarch.com AA26001089 10-20-2020A R CH I T ECT URE DATE:$7+.&+0)+&'#5 A1.5 DEMOLITION PLAN - RSL C:\PROJ\0300\A1 1 A1.5 SCALE: 1/4" = 1'-0" DEMOLITION PLAN NOTE: EXISTING ELECTRICAL SERVICE TO BE COMPLETELY REMOVED. ALL PANELS, CIRCUITS, AND WIRING TO BE REMOVED. NEW ELECTRICAL SERVICE TO BE PROVIDED EXISTING MECHANICAL SYSTEM TO BE COMPLETELY REMOVED. NEW MECHANICAL EQUIPMENT TO BE INSTALLED. ALL INTERIOR DOORS AND WINDOWS TO BE REMOVED AND REPLACED 2 A1.5 SCALE : 1/2" = 1'-0" SLAB REPAIR DETAIL 4 A1.5 SCALE : NTS TRENCHING REPAIR DETAIL G:\BuildingIdeas\2000\2023-5911BirchDr-Cason-EvansRes-Fire\05-SD\X-base-Evans-201016.dwg, 10/20/2020 3:39:54 PM, Robert S Lewis P.A. AR91402 (561) 441-8126 rlewis@biarch.com 3'-0"x6'-8"3'-0"x4'-0" SH@ 2'-11" A.F.F.4'-3"x4'-0" SH @ 2'-11" A.F.F.4'-3"x4'-0" SH@ 2'-11" A.F.F.4'-3"x4'-0" SH@ 2'-11" A.F.F.4'-3"x4'-0" SH @ 2'-11" A.F.F.2'-8"x6'-8"2'-8"x6'-8" 9'-0"x6'-10" OHGD SH 22 SH 223'-0"x6'-8"2'-8"x6'-8" 4'-0"x6'-8" BF 2'-8"x6'-8" 2'-10"x6'-8"1'-5"x2'-0" SH@ 4'-11" A.F.F.13'-11 1/2"5"2'-0"13'-9"5"6'-2"13'-11 1/2"2'-0"14'-4"6 1/2" 14'-10 1/2"8'-4"2'-10"x6'-8"3'-0"x6'-8"14'-1"5"16'-4 1/2"6'-0"3'-4"4'-0"x6'-8" BF 5"2'-8"x6'-8"3'-0"5"9'-4"5"6'-0"x6'-8" BP3'-0"x6'-8"3 1/2"6'-9"14'-7 1/2"4'-2"4'-2 1/2"5" 6'-1"3'-0"x6'-8"3'-8"2'-0"5"4'-0"6'-5"3'-8"2'-0"5"2'-0" 3'-10" 2'-10" MIN. (3) FRAMING MEMBERS IN CORNER INFILL EXISTING WINDOW SEE DETAIL 2/A2 6'-2"5"7'-2"5'-0"6'-0" NEW CONCRETE LANDING AT EXTERIOR DOOR 3" STEP AT DOOR MIN. (3) FRAMING MEMBERS IN CORNER FRONT PORCH SLAB TO BE BROUGHT LEVEL TO THE EXISTING INTERIOR SLAB HEIGHT CONTRACTOR TO ROUGHEN EXISTING SLAB AND ADD STO CR 245 BONDING AGENT PRIOR TO POUR. CONCRETE FINISH TO MATCH EXISTING SLAB HEIGHT. GARAGE KITCHEN DINING RM. LIVING RM. BEDROOM #3 BEDROOM #2 BEDROOM #1 W.I.C. #1 BATH #1 BATH #2 SHOWER SEAT 19" A.F.F.7'-9"1'-7"2" STEP REINFORCE AND BRACE GABLE END TRUSS SEE DETAIL 1-2/A9.1 REINFORCE AND BRACE GABLE END TRUSS SEE DETAIL 1-2/A9.1 REPAIR (2) TRUSS BOTTOM CHORDS SEE 3/A9.1 REINFORCE THE TRUSS BOTTOM CHORD ON EACH SIDE OF THESE (2) TRUSSES. 'C' LABEL DOOR'C' LABELDOORSISTER A 2x6 TO THE BOTTOM CHORD OF THE GABLE TRUSS BETWEEN THE GARAGE AND LIVING ROOM. 3" WOOD SCREWS SEE DETAIL 4/A9.1 SHEET TITLE : PROJECT TITLE : COMMISSION # : REVISIONS : FILE NAME : REV #DATE DESCRIPTION OFFICE INFORMATION DRAWN BY : CHECKED BY : ISSUE DATE : RSL 10/20/2020 2023 EVANS RESIDENCE FIRE REPAIR 5911 Birch Dr, Fort Pierce, FL 34982, USA PID: 3402-609-0592-000-8 - -- CONSULTANTS : 22062 CONCHA AVE. BOCA RATON, FL. 33428 ROBERT S. LEWIS REG # : AR91402 PH : 1.772.408.6963 FAX : Ancient tech email it. No one faxes anymore EMAIL: rlewis@biarch.com AA26001089 10-20-2020A R CH I T ECT URE DATE:$7+.&+0)+&'#5 A-2.0 FLOOR PLAN - - RSL C:\PROJ\0300\A1 OPENING ID PRODUCT MODEL #MANUFACTURER EVALUATION AGENCY NOA # BUILDING DESIGN PRESSURE PRODUCT DESIGN PRESSURE EXPIRATION DATE DOORSWINDOWNOTES NOTE: VERIFY ALL R.O. PRIOR TO ORDERING WINDOWS. VERIFY R.O. FROM WINDOW MANUF. PRIOR TO PLACING BLOCK. METHOD OF ATTACHMENT S.M.IL.M.ISHUTTERSREQ.- SEE FLOOR PLAN NOTES-BUILDING #7 FOR INFORMATION REGARDING REQUIRED LOCATIONS REQUIRING TEMPERED GLASS - CONTRACTOR TO CONFIRM ALL INFORMATION FROM MANUFACTURES RECOMENDATIONS AND NOA PRIOR TO INSTALLATION. - SHUTTER INSTALLER TO REVIEW DOCS PRIOR TO QUOTING MATERIALS. SHUTTER INSTALLER TO VISIT SITE FOR FIELD MEASUREMENTS PRIOR TO ORDERING MATERIALS. SHUTTER ANCHORS TO BE REVIEWED AND APPROVED BY INSTALLER. -VERIFY ALL EXISITNG ROUGH OPENINGS ON SITE PRIOR TO ORDERING WINDOWS - PROVIDE OWNER WITH THE OPTION OF WINDOW AND DOOR MUTTONS IN LIEU OF CLEAR GLASS OPENINGS. - SOME OF THE WINDOWS ABOVE MAY BE WITHIN AN INTERIOR ZONE REQUIRING LOWER DESIGN PRESSURES. IF A HIGHER DESIGN PRESSURE IS SHOWN IT MAY BE BECAUSE ANOTHER SIMILAR WINDOW TYPE IS GROUPED WITH IT THAT LIES WITHIN AN EDGE ZONE. IN EITHER CIRCUMSTANCE IF THE PRODUCT PRESSURE IS HIGHER THAN THE DESIGN PRESSURE SHOWN THE PRODUCT EXCEEDS THE MINIMUM PRESSURE REQUIREMENTS. REPORT # R.O. ROOF SIDING 100 FD-5555 Outswing PVC French Door PGT INDUSTRIES 20-0427.05 1-23-2024 - 58 + 43 - 70 + 70 3'-0"x6'-8" OUTSWING 3'-4"X6'-10" - WINDOW SILLS - IN DWELLING UNITS WHERE THE OPENING OF THE OPERABLE WINDOW IS LOCATED MORE THAN 72" ABOVE THE FINISHED GRADE OR SURFACE BELOW SHALL BE A MINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR. GLAZING BETWEEN THE FLOOR AND 24 NCHES SHALL BE FIXED OR HAVE OPENINGS THROUGH WHICH A 4" DIAMETER SPHERE CANNOT PASS. (GUARD RAIL) -WINDOW EGRESS - MIN 20" WIDE MIN. 24" HIGH MIN. 5 SQUARE FEET @ GRADE, 5.7 SQUARE FEET ALL OTHERS. SILL HEIGHT BETWEEN 24" AND 44". - WINDOW SIZE - MIN 8% OF ROOM FLOOR AREA. MINIMUM VENTILATION (OPEN AREA) SHALL BE 4% OF FLOOR AREA. WINDOWS AND DOOR VALUES SHALL BE MIN. SHGC=.24 AND U=.67 #10 STEEL SMS, MIN 1 2" EDGE DISTANCE, 1-3/8" MIN EMBEDMENT, 4" MAX CORNERS, 12" O.C. GLASS TYPES 2 OR 7 ONLY 1 A2.0 SCALE: 1/4" = 1'-0" FLOOR PLAN 2 A3 3 A3 1 A3 NOTE: REPLACE ALL ELECTRIC, SEE ELECTRICAL REPLACE ALL MECHANICAL SEE MECHANICAL ALL NEW FLOORING, WALL FINISH, BASE BOARDS CLOSED CELL FOAM INSULATION MIN 4" R19. 1 2" GYPSUM BOARD WALLS AND CEILING TO BE INSTALLED. THE EXISTING ATTIC SPACE ABOVE THE BEDROOM SECTION OF THE HOME WILL RECEIVE NEW BATT INSULATION TO BRING THE VALUE TO MIN. R38 CONTRACTOR TO DISCUSS WITH THE OWNER CLOSING THE ATTIC SPACE AND INSTALLING FOAM INSULATION AS AN ALTERNATIVE. A 3'-0"x2'-0"3'-2"x2'-2"SH-5500 PVC Single Hung Window PGT INDUSTRIES MAIMI DADE - 210 + 100 1/4" ULTRACON, 1-1/4" MIN EMBEDMENT, 5-1/2" EDGE DISTANCE, 6" CORNERS, 10" STYLE, 14.375" MAX SPACING. 20-0401.03 7-30-2025 ALL GLASS TYPES MEET DESIGN PRESSURE MAIMI DADE - 58 + 43 2 A2.0 SCALE: 1/2" = 1'-0" WINDOW INFILL DETAIL 4 A2.0 SCALE: 1/2" = 1'-0" EXISTING WALL REINFORCEMENT DETAIL B 1'-5"x2'-0"1'-7"x2'-2"SH-5500 PVC Single Hung Window PGT INDUSTRIES MAIMI DADE - 210 + 100 1/4" ULTRACON, 1-1/4" MIN EMBEDMENT, 5-1/2" EDGE DISTANCE, 6" CORNERS, 10" STYLE, 14.375" MAX SPACING. 20-0401.03 7-30-2025 ALL GLASS TYPES MEET DESIGN PRESSURE- 58 + 43 G:\BuildingIdeas\2000\2023-5911BirchDr-Cason-EvansRes-Fire\05-SD\X-base-Evans-201016.dwg, 10/20/2020 3:39:57 PM, Robert S Lewis P.A. AR91402 (561) 441-8126 rlewis@biarch.com VENT TO BE CLOSED PRIOR TO INSTALLING INSULATION WITHIN THE ATTIC NEW DOOR CEDAR TRIM NEW DOOR CEDAR TRIM VENT TO BE CLOSED PRIOR TO INSTALLING INSULATION WITHIN THE ATTIC PRIOR ENTRY BOUNDARY EXISTING SIDING LEFT OFF OF THIS ELEVATION FOR CLARITY OF NEW WORK CEDAR TRIM WOOD SIDING TO MATCH THE EXISTING RESIDENCE PRIOR ENTRY BOTTOM OF BEAM CEDAR TRIM WOOD SIDING TO MATCH THE EXISTING RESIDENCE EXISTING ROOF EXISTING ROOF EXISTING RESIDENCE EXISTING SIDING LEFT OFF OF THIS ELEVATION FOR CLARITY OF NEW WORK GARAGE FRONT ENTRY GARAGE KITCHEN EL. 0'-0" MATCH EXISTING FINISHED FLOOR CONTRACTOR TO ROUGHEN EXISTING SLAB AND ADD STO CR 245 BONDING AGENT PRIOR TO POUR. CONCRETE FINISH TO MATCH EXISTING SLAB HEIGHT. SHEET TITLE : PROJECT TITLE : COMMISSION # : REVISIONS : FILE NAME : REV #DATE DESCRIPTION OFFICE INFORMATION DRAWN BY : CHECKED BY : ISSUE DATE : RSL 10/20/2020 2023 EVANS RESIDENCE FIRE REPAIR 5911 Birch Dr, Fort Pierce, FL 34982, USA PID: 3402-609-0592-000-8 - -- CONSULTANTS : 22062 CONCHA AVE. BOCA RATON, FL. 33428 ROBERT S. LEWIS REG # : AR91402 PH : 1.772.408.6963 FAX : Ancient tech email it. No one faxes anymore EMAIL: rlewis@biarch.com AA26001089 10-20-2020A R CH I T ECT URE DATE:$7+.&+0)+&'#5 A-3.0 Elevations Building Section - RSL C:\PROJ\0300\A1 1 A3.0 SCALE: 1/4" = 1'-0" REAR ELEVATION 2 A3.0 SCALE: 1/4" = 1'-0" FRONT ELEVATION 3 A3.0 SCALE: 1/4" = 1'-0" RIGHT ELEVATION 5 A3.0 SCALE: 1/4" = 1'-0" ENTRY SECTION DEMOLITION 8 A3.0 SCALE: 1/4" = 1'-0" ENTRY SECTION 3 A2.0 SCALE: 3/4" = 1'-0" ENTRY WALL SECTION 3 A2.0 G:\BuildingIdeas\2000\2023-5911BirchDr-Cason-EvansRes-Fire\05-SD\X-base-Evans-201016.dwg, 10/20/2020 3:40:01 PM, Robert S Lewis P.A. AR91402 (561) 441-8126 rlewis@biarch.com SHEET TITLE : PROJECT TITLE : COMMISSION # : REVISIONS : FILE NAME : REV #DATE DESCRIPTION OFFICE INFORMATION DRAWN BY : CHECKED BY : ISSUE DATE : RSL 10/20/2020 2023 EVANS RESIDENCE FIRE REPAIR 5911 Birch Dr, Fort Pierce, FL 34982, USA PID: 3402-609-0592-000-8 - -- CONSULTANTS : 22062 CONCHA AVE. BOCA RATON, FL. 33428 ROBERT S. LEWIS REG # : AR91402 PH : 1.772.408.6963 FAX : Ancient tech email it. No one faxes anymore EMAIL: rlewis@biarch.com AA26001089 10-20-2020A R CH I T ECT URE DATE:$7+.&+0)+&'#5 A-9.0 INTERIOR DETAILS - - RSL C:\PROJ\0300\A1 1 A9.0 SCALE : NTS TYP. INTERIOR PARTITIONS 2 A9.0 SCALE : NTS BLOCKING DET.3 A9 SCALE : NTS SCUTTLE DETAIL 15 A9.0 WOOD- WINDOW WATERPROOFING DETAIL SCALE : NTS 4 A9 SCALE : NTS WOOD CORNER DET 5 A9 SCALE : NTS DOOR SILL DET 6 A9 SCALE : NTS WINDOW HEAD DET.7 A9 SCALE : NTS WINDOW SILL DET.8 A9 SCALE : NTS WINDOW JAMB DET.9 A9 SCALE : NTS GARAGE WALL DETAIL G:\BuildingIdeas\2000\2023-5911BirchDr-Cason-EvansRes-Fire\05-SD\X-base-Evans-201016.dwg, 10/20/2020 3:40:04 PM, Robert S Lewis P.A. AR91402 (561) 441-8126 rlewis@biarch.com CONNECT (2) 2"x6"x ( 8" BEARING MIN) 3" WOOD SCREWS (2) ROWS STAGGERED SPACE 4" O.C. OUTSIDE FACE TOWARDS THE FRONT DOOR MAY NOT HAVE 8" BEARING AND THIS IS ALREADY TAKEN INTO CONSIDERATION. CONNECT (2) 2"x4"x6'-0" W/ 0.131"x2.5" NAILS (2) ROWS STAGGERED SPACE 4" O.C. (2) TRUSSES ON EACH SIDE OF DAMAGED TRUSS 2x4 INFILL DAMAGED WEB MEMBER 2x4 INFILL DAMAGED WEB MEMBER 3'-0"3'-0" 3'-0"3'-0" TRUSS #2 TRUSS #1 CONNECT (1) 2"x4"x8'-0" W/ 0.131"x2.5" NAILS (2) ROWS STAGGERED SPACE 4" O.C. TO THE TRUSS BEFORE TRUSS #1 AND AFTER TRUSS #2 SHEET TITLE : PROJECT TITLE : COMMISSION # : REVISIONS : FILE NAME : REV #DATE DESCRIPTION OFFICE INFORMATION DRAWN BY : CHECKED BY : ISSUE DATE : RSL 10/20/2020 2023 EVANS RESIDENCE FIRE REPAIR 5911 Birch Dr, Fort Pierce, FL 34982, USA PID: 3402-609-0592-000-8 - -- CONSULTANTS : 22062 CONCHA AVE. BOCA RATON, FL. 33428 ROBERT S. LEWIS REG # : AR91402 PH : 1.772.408.6963 FAX : Ancient tech email it. No one faxes anymore EMAIL: rlewis@biarch.com AA26001089 10-20-2020A R CH I T ECT URE DATE:$7+.&+0)+&'#5 A-9.1 DETAILS - - RSL C:\PROJ\0300\A1 1 A9.1 SCALE : NTS GABLE END BRACING DETAIL 2 A9.1 SCALE : NTS GABLE END REINFORCEMENT DETAIL 3 A9.1 SCALE : NTS DAMAGED BOTTOM CHORD REPAIR 4 A9.1 SCALE : NTS CABINETRY DETAIL 4 A9.1 SCALE : NTS REINFORCEMENT DETAIL OVER KITCHEN GABLE END BOTTOM CHORD G:\BuildingIdeas\2000\2023-5911BirchDr-Cason-EvansRes-Fire\05-SD\X-base-Evans-201016.dwg, 10/20/2020 3:40:15 PM, Robert S Lewis P.A. AR91402 (561) 441-8126 rlewis@biarch.com 3'-0"x6'-8"3'-0"x4'-0" SH@ 2'-11" A.F.F.4'-3"x4'-0" SH @ 2'-11" A.F.F.4'-3"x4'-0" SH@ 2'-11" A.F.F.4'-3"x4'-0" SH@ 2'-11" A.F.F.4'-3"x4'-0" SH @ 2'-11" A.F.F.2'-8"x6'-8"2'-8"x6'-8" 9'-0"x6'-10" OHGD 3'-0"x6'-8"1'-5"x2'-0" SH@ 4'-11" A.F.F.3'-0"x6'-8"GARAGE KITCHEN DINING RM. LIVING RM. BEDROOM #3 BEDROOM #2 BEDROOM #1 W.I.C. #1 BATH #1 BATH #2 GFI WP SD SD SDSD SD UC VP VP VP GFI WP GFI S 3 S SS S D SS D S D S 3 S S 4 SHEET TITLE : PROJECT TITLE : COMMISSION # : REVISIONS : FILE NAME : REV #DATE DESCRIPTION OFFICE INFORMATION DRAWN BY : CHECKED BY : ISSUE DATE : RSL 10/20/2020 2023 EVANS RESIDENCE FIRE REPAIR 5911 Birch Dr, Fort Pierce, FL 34982, USA PID: 3402-609-0592-000-8 - -- CONSULTANTS : 22062 CONCHA AVE. BOCA RATON, FL. 33428 ROBERT S. LEWIS REG # : AR91402 PH : 1.772.408.6963 FAX : Ancient tech email it. No one faxes anymore EMAIL: rlewis@biarch.com AA26001089 10-20-2020A R CH I T ECT URE DATE:$7+.&+0)+&'#5 E1 ELECTRICAL PLAN RSL C:\PROJ\0300\A1 1 E1 SCALE : 1/4" = 1'-0" POWER PLAN S D SDIMMER SWITCH FOR LIGHT SWITCH FOR CEILING FAN COMBINATION LIGHT/CLG. FAN COMB. LIGHT/CLG. FAN SWITCHING DETAIL 2 E1 SCALE :NTS CON- DUIT WIRE POLE TRIPREMARKSCKT NO REMARKS 9 7 3 5 1 10 NO 8 4 2 6 CKT 17 19 13 15 11 27 25 23 21 28 18 26 24 22 20 14 16 12 29 30 WIRE DUIT CON- POLE TRIPNO DEM V.A. DEM V.A.V.A NO DEM V.A DEM MAINS: MAIN BUS: NEUTRAL: A.I.C MOUNTING: SERVICE: TYPE: POLES: 1957 SQ. FT. AT 3VA/SF = 5871 VA1 2 EXISTING 4 NEW NOTE: ELECTRICIAN TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO ORDERING AND/OR INSTALLATION OF EQUIPMENT. ALL NEW LIGHT FIXTURES SHALL BE LED INTERIOR PANEL LOCATED IN BEDROOM #3 37 35 33 31 39 38 36 34 32 40 3 RELOCATE TO NEW PANEL 41 42 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 MOTOR STARTERS SHALL BE MANUAL MAGNETIC, WITH OVERLOAD RELAYS IN EACH HOT LEG CONTRACTOR SHALL BE RESPONSIBLE FOR BALANCING ALL LOADS ON THE VARIOUS PANEL BOARDS FOR EXISTING & NEW CIRCUITS TO ALLEVIATE OVERLOAD. ALL FUSES, UNLESS NOTED ON DRAWING SHALL BE CURRENT LIMITED FUSES (CL) RATED FOR 100,000 AIC. ALL CIRCUIT BREAKERS, TWO AND THREE POLE, TO BE COMMON TRIP. NO TIE HANDLES, OR TANDEMS WILL BE ACCEPTED. ALL RACEWAYS UNDERGROUND SHALL BE A MINIMUM OF 3/4" CONDUIT. FURNISH AND INSTALL DISCONNECT SWITCHES AND WIRING FOR AIR CONDITIONING SYSTEM A PER MANUFACTURERS RECOMMENDATIONS. CONTROLS ARE TO BE SUPPLIED BY AIR CONDITIONING CONTRACTOR AND CONNECTED BY ELECTRICAL CONTRACTOR. THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF POWER AND TELEPHONE COMPANIES. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS, AND TESTING. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY OF PROPERTY DAMAGE FOR THE DURATION OF THE WORK. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE A SHALL INCLUDE REPLACEMENT OR REPAIR OR ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE YEAR FROM THE DATE OF ACCEPTANCE. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. ALL MATERIAL SHALL BE NEW AND BEAR UNDERWRITERS LABELS WHERE APPLICABLE. ELECTRICAL SYSTEM SHALL BE COMPLETE AND EFFECTIVELY GROUNDED AS REQUIRED BY THE LATEST EDITION OF THE NEC. IT IS NOT THE INTENT OF THESE PLANS TO SOW EVERY MINOR DETAIL OF CONSTRUCTION THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. ELECTRICAL CONTRACTOR TO COORDINATE LOCATION OF NEW METER AND DISCONNECT WITH UTILITY PROVIDER SMOKE DETECTORS SHALL BE PROVIDED W/ A VISIBLE "POWER ON INDICATOR" & TEST BUTTON. SMOKE DETECTORS SHALL BE HARD WIRED (110V TYPE) TO A NON-SWITCHABLE KITCHEN OR BATHROOM LIGHTING CIRCUIT & SHALL NOT BE CONNECTED TO THE LOAD SIDE OF A GROUND FAULT CIRCUIT INTERRUPTER. ALL ELECTRICAL MATERIALS, DEVICES AND APPLIANCES MUST BE CERTIFIED BY AN APPROVED TESTING LABORATORY AS PER FBC 4503 STANDARDS. ALL OUTSIDE EQUIPMENT SHALL BE WATERPROOF FIXTURE SHOP DRAWINGS SHALL BE APPROVED BY ARCHITECT BEFORE ORDERING. ALL MATERIALS SHALL BE "U.L. APPROVED" SWITCH HEIGHT SHALL BE 44" AFF UNLESS OTHERWISE NOTED ON PLAN RECEPTACLE HEIGHT TO BE 18" AFF UNLESS NOTED OTHERWISE ON PLAN PLUG RECEPTACLES TO BE 120V 20A INTERMEDIATE GRADE, GROUNDING, FLUSH TYPE, RECEPTACLE AND COVER PLATES TO BE IVORY IN COLOR ELECTRICAL OUTLETS IN FINISHED AREAS IN WALLS & FLOORS SHALL BE RECESSED INTO THE STRUCTURE WITH FACE FLUSH WITH SURFACE. ALL CONDUITS FOR SUCH OUTLETS SHALL BE CONCEALED IN THE STRUCTURE. CONTRACTOR SHALL BE HELD TO HAVE EXAMINED THE SITE WITH RESPECT TO ALL EXISTING FIELD CONDITIONS, SERVICE SIZE, LOCATIONS, AND TO HAVE FULLY EXAMINED THE ORIGINAL PLANS FOR THIS BUILDING 28. 27. 26. 25. 24. 23. 22. 21. 20. 19. 18. 17. 16. 15. 14. 13. 12. 11. 10. 9. 8. 7. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS, AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. UL RATED PLASTIC IS AN APPROVED EQUAL. MINIMUM WIRE SIZE SHALL BE #12 AWG, EXCLUDING CONTROL WIRING UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE COPPER WITH THWN INSULATION. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NEC) AND SHALL COMPLY WITH N.F.P.A., LOCAL AND STATE APPLICABLE CODES . DO NOT SCALE THE ELECTRICAL DRAWINGS REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT CONFIRM WITH OWNER REPRESENTATIVE. DISCONNECT SWITCHES SHALL BE GENERAL DUTY, QUICK MAKE, QUICK BREAK ENCLOSURES WITH WP RATING, AS REQUIRED BY EXPOSURE. 4. 3. 2. 1. 6. 5. ALL POWER EXISTING U.N.O. BY CIRCUIT #.29. 16. A) ALL 120-VOLT, SINGLE PHASE, 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER COMBINATION-TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT (NEC 210.12(B)). B) TAMPER-RESISTANT RECEPTACLES (NEC 406.11) ARE REQUIRED IN DWELLING UNITS IN ALL AREAS AS SPECIFIED IN 2008 NEC 210.52, ALL 125-VOLT, 15 AND 20 AMP RECEPTACLES 30. ALL 120-VOLT, SINGLE PHASE, 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT KITCHEN SHALL BE GFCI BY CIRCUIT BREAKER OR BY OUTLET. THIS INCLUDES EQUIPMENT SUCH AS REFRIGERATORS, DISHWASHERS, DISPOSALS, AND MICROWAVES. 31 NOTE FOR ELECTRICIAN: REVIEW EXISTING FIELD CONDITIONS. 1) LABEL THE PANEL. 2) IF A PANEL IS BEING FED FROM ANOTHER PANEL ADD A PERMANENT NOTE TO THE PANEL DOOR SAYING WHICH PANEL IT IS FED FROM 3) IF THE EXISTING GROUND CAN NOT BE LOCATED THEN THE ELECTRICIAN WILL PROVIDE (2) SEPARATE GROUNDING RODS PLACE 8FT INTO THE GROUND MIN. 6FT APART FROM ONE ANOTHER. #4 COPPER GROUND. 5871VA 3000 VA 10000VA 1200 VA 5000 VA 4500 VA 1200 VA 1200 VA 735 VA 1200 VA 1200 VA 1200 VA 1100 VA 2400 VA 38806 VA 10000 VA 11522 VA 6500 VA 28022 VA 1957 SQ. FT. @ 3VA/SQ. FT. ______ (2) SMALL APPL. CKTS @ 1500VA EA RANGE SPRINKLER PUMP DRYER HOT WATER REFRIGERATOR MICROWAVE D.W. DISPOSAL WASHER OUTDOOR REF. GDO EXTERIOR GARAGE TOTAL CONN. LOAD _______ 1ST 10,000 VA @ 100% REMAINDER @ 40% AHU ( 10 KW ESH) @ 65% TOTAL CALC. LOAD ________ 28022 VA/ 240V = 117 AMPS G:\BuildingIdeas\2000\2023-5911BirchDr-Cason-EvansRes-Fire\05-SD\X-base-Evans-201016.dwg, 10/20/2020 3:40:17 PM, Robert S Lewis P.A. AR91402 (561) 441-8126 rlewis@biarch.com SHEET TITLE : PROJECT TITLE : COMMISSION # : REVISIONS : FILE NAME : REV #DATE DESCRIPTION OFFICE INFORMATION DRAWN BY : CHECKED BY : ISSUE DATE : RSL 10/20/2020 2023 EVANS RESIDENCE FIRE REPAIR 5911 Birch Dr, Fort Pierce, FL 34982, USA PID: 3402-609-0592-000-8 - -- CONSULTANTS : 22062 CONCHA AVE. BOCA RATON, FL. 33428 ROBERT S. LEWIS REG # : AR91402 PH : 1.772.408.6963 FAX : Ancient tech email it. No one faxes anymore EMAIL: rlewis@biarch.com AA26001089 10-20-2020A R CH I T ECTURE DATE:$7+.&+0)+&'#5 M-1 MECHANICAL NOTES - - RSL C:\PROJ\0300\A1 #+4*#0&.'45 %10&'05+0)70+65 4Ä# G:\BuildingIdeas\2000\2023-5911BirchDr-Cason-EvansRes-Fire\05-SD\X-base-Evans-201016.dwg, 10/20/2020 3:40:21 PM, Robert S Lewis P.A. AR91402 (561) 441-8126 rlewis@biarch.com 3'-0"x6'-8"3'-0"x4'-0" SH@ 2'-11" A.F.F.4'-3"x4'-0" SH @ 2'-11" A.F.F.4'-3"x4'-0" SH@ 2'-11" A.F.F.4'-3"x4'-0" SH@ 2'-11" A.F.F.4'-3"x4'-0" SH @ 2'-11" A.F.F.2'-8"x6'-8"2'-8"x6'-8" 9'-0"x6'-10" OHGD SH 22 SH 223'-0"x6'-8"2'-8"x6'-8" 4'-0"x6'-8" BF 2'-8"x6'-8" 2'-10"x6'-8"1'-5"x2'-0" SH@ 4'-11" A.F.F.2'-10"x6'-8"3'-0"x6'-8"4'-0"x6'-8" BF 2'-8"x6'-8"6'-0"x6'-8" BP3'-0"x6'-8"3'-0"x6'-8"GARAGE KITCHEN DINING RM. LIVING RM. BEDROOM #3 BEDROOM #2 BEDROOM #1 W.I.C. #1 BATH #1 BATH #2 2" STEP SHEET TITLE : PROJECT TITLE : COMMISSION # : REVISIONS : FILE NAME : REV #DATE DESCRIPTION OFFICE INFORMATION DRAWN BY : CHECKED BY : ISSUE DATE : RSL 10/20/2020 2023 EVANS RESIDENCE FIRE REPAIR 5911 Birch Dr, Fort Pierce, FL 34982, USA PID: 3402-609-0592-000-8 - -- CONSULTANTS : 22062 CONCHA AVE. BOCA RATON, FL. 33428 ROBERT S. LEWIS REG # : AR91402 PH : 1.772.408.6963 FAX : Ancient tech email it. No one faxes anymore EMAIL: rlewis@biarch.com AA26001089 10-20-2020A R CH I T ECT URE DATE:$7+.&+0)+&'#5 M-2 MECHANICAL PLAN - - RSL C:\PROJ\0300\A1 G:\BuildingIdeas\2000\2023-5911BirchDr-Cason-EvansRes-Fire\05-SD\X-base-Evans-201016.dwg, 10/20/2020 3:40:23 PM, Robert S Lewis P.A. AR91402 (561) 441-8126 rlewis@biarch.com SHEET TITLE : PROJECT TITLE : COMMISSION # : REVISIONS : FILE NAME : REV #DATE DESCRIPTION OFFICE INFORMATION DRAWN BY : CHECKED BY : ISSUE DATE : RSL 10/20/2020 2023 EVANS RESIDENCE FIRE REPAIR 5911 Birch Dr, Fort Pierce, FL 34982, USA PID: 3402-609-0592-000-8 - -- CONSULTANTS : 22062 CONCHA AVE. BOCA RATON, FL. 33428 ROBERT S. LEWIS REG # : AR91402 PH : 1.772.408.6963 FAX : Ancient tech email it. No one faxes anymore EMAIL: rlewis@biarch.com AA26001089 10-20-2020A R CH I T ECT URE DATE:$7+.&+0)+&'#5 M-3 MECHANICAL DETAILS - RSL C:\PROJ\0300\A1 5%#.' 065 5%#.' 065 5%#.' 065 5%#.' 065 5%#.' 065 5%#.' 065 5%#.' 065 G:\BuildingIdeas\2000\2023-5911BirchDr-Cason-EvansRes-Fire\05-SD\X-base-Evans-201016.dwg, 10/20/2020 3:40:24 PM, Robert S Lewis P.A. AR91402 (561) 441-8126 rlewis@biarch.com 2'-8"x6'-8"1'-5"x2'-0" SH@ 4'-11" A.F.F.DINING RM. BATH #1 BATH #2 3'-0"x6'-8"KITCHEN SHEET TITLE : PROJECT TITLE : COMMISSION # : REVISIONS : FILE NAME : REV #DATE DESCRIPTION OFFICE INFORMATION DRAWN BY : CHECKED BY : ISSUE DATE : RSL 10/20/2020 2023 EVANS RESIDENCE FIRE REPAIR 5911 Birch Dr, Fort Pierce, FL 34982, USA PID: 3402-609-0592-000-8 - -- CONSULTANTS : 22062 CONCHA AVE. BOCA RATON, FL. 33428 ROBERT S. LEWIS REG # : AR91402 PH : 1.772.408.6963 FAX : Ancient tech email it. No one faxes anymore EMAIL: rlewis@biarch.com AA26001089 10-20-2020A R CH I T ECT URE DATE:$7+.&+0)+&'#5 P-1 PLUMBING - - RSL C:\PROJ\0300\A1 1 P1 SCALE: 1/2" = 1'-0" PLUMBING PLAN-BATHROOM PLUMBING NOTES FIXTURE / DESCRIPTION AQUALYN #0476.028 CADET #2168.128 MOEN SINGLE BOWL #22106 8799 FAUCET W/ #Z-40 DRAIN ASSEMBLY SUPPLY PIPES, MCGUIRE ANGLE STOPS & ADJUSTABLE 'P' TRAP CHURCH OPEN FRONT SEAT , SUPPLY PIPE, MCGUIRE ANGLE STOP AND 2" BOLT CAPS ZURN SIERRA 7442 FAUCET 3/8" FLEX. SUPPLY PIPE, MCGUIRE ANGLE STOP & ADJUSTABLE 'P' TRAP W/ DRAIN NOTES 1 1/4" 3" 3" MAXIMUM FLOW RATE OR QUANTITY PLUMBING TABLE 604.4 MFG. NO. DROP-IN LAVATORY SINK TANK WATER CLOSET 1 4 6 FU WATER PIPE SIZE 1" 1/2" SINK FAUCET URINAL PRIVATE PUBLIC LAVATORY FIXTURE WATER CLOSET WATER CLOSET PLUMBING FIXTURES LAVATORY, PRIVATE OR FIXTURE FITTINGS LAVATORY, PUBLIC LAVATORY, PUBLIC, METERING SHOWER HEAD WATER CLOSET PLUMBING FIXTURE SCHEDULE NOMINAL SAN. SIZE MAX FLOW RATES - 1.5 GPM AT 60 PSI .5 GPM AT 60 PSI .25 GP METERING CYCLE 2.0 GPM AT 80 PSI 2.0 GPM AT 80 PSI 0.5 GAL PER FLUSHING CYCLE 1.28 GAL PER FLUSHING CYCLE SHALL BE CONSISTANT WITH FIXTURE OUTLET SIZE SHALL BE CONSISTANT WITH FIXTURE OUTLET SIZE 1 1/2" 1 1/2" 2 2 1/2" 1/2"KITCHEN SINK SHOWER 1/2" D.W. RESIDENTIAL D.W. COMMERCIAL 6.5 GAL PER CYCLE OR LESS ( E. STAR OR W. CERT.) WATER FACTOR OF 8 OR LOWER ( E. STAR/ W. SENSE CERT) <1.2 GAL. PER RACK FOR FILL AND DUMP. 0.9 GAL FOR LOW TEMP D.W. COMMERCIAL UNDER COUNTER 1 GAL PER RACK H.T., 1.5 GALLONS PER RACK L.T. WASHING MACHINE 1 P1 SCALE: 1/2" = 1'-0" PLUMBING PLAN- KITCHEN EXISTING SANITARY LINE TO EXISTING HOT AND COLD WATER SUPPLY EXISTING SANITARY LINE TO EXISTING HOT AND COLD WATER SUPPLY NOTE: PROVIDE 1 4" WATER SUPPLY LINE WITH SHUTOFF TO REFRIGERATOR LOCATION 2 P1 SCALE: 1/2" = 1'-0" SANITARY RISER 3 P1 SCALE: 1/2" = 1'-0" PLUMBING SUPPLY MASTER BATH BATH 2 KITCHEN NEW KITCHEN ISLAND SINK TO EXISTING SANITARY TO EXISTING SANITARY KITCHEN NOTE: PROVIDE 1 4" WATER SUPPLY LINE WITH SHUTOFF TO REFRIGERATOR LOCATION FBC PLUMBING 424.3 Individual shower valves. Individual shower and tub-shower combination valves shall be balanced-pressure, thermostatic or combination balanced-pressure/thermostatic valves that conform to the requirements of ASSE 1016 or ASME A112.18.1/CSA B125.1 and shall be installed at the point of use. Shower and tub-shower combination valves required by this section shall be equipped with a means to limit the maximum setting of the valve to 120 degrees F (49 degrees C), which shall be field adjusted in accordance with the manufacturers instructions. In line thermostatic valves shall not be utilized for compliance with this section VALVES SHALL BE BALANCED - PRESSURE, THERMOSTATIC OR COMBINATION BALANCED-PRESSURE/THERMOSTATIC VALVES THAT CONFORM TO THE REQUIREMENTS OF ASSE 1016.G:\BuildingIdeas\2000\2023-5911BirchDr-Cason-EvansRes-Fire\05-SD\X-base-Evans-201016.dwg, 10/20/2020 3:40:25 PM, Robert S Lewis P.A. AR91402 (561) 441-8126 rlewis@biarch.com SHEET TITLE : PROJECT TITLE : COMMISSION # : REVISIONS : FILE NAME : REV #DATE DESCRIPTION OFFICE INFORMATION DRAWN BY : CHECKED BY : ISSUE DATE : RSL 10/20/2020 2023 EVANS RESIDENCE FIRE REPAIR 5911 Birch Dr, Fort Pierce, FL 34982, USA PID: 3402-609-0592-000-8 - -- CONSULTANTS : 22062 CONCHA AVE. BOCA RATON, FL. 33428 ROBERT S. LEWIS REG # : AR91402 PH : 1.772.408.6963 FAX : Ancient tech email it. No one faxes anymore EMAIL: rlewis@biarch.com AA26001089 10-20-2020A R CH I T ECT URE DATE:$7+.&+0)+&'#5 C1 COMMENTS, RESPONSES AND FIELD REVISIONS RSL C:\PROJ\0300\A1 REVISIONS THIS SHEET IS INITIALLY SUBMITTED BLANK TO RECEIVE FUTURE COMMENTS, RESPONSES, AND FIELD REVISIONS.G:\BuildingIdeas\2000\2023-5911BirchDr-Cason-EvansRes-Fire\05-SD\X-base-Evans-201016.dwg, 10/20/2020 3:40:28 PM, Robert S Lewis P.A. AR91402 (561) 441-8126 rlewis@biarch.com