HomeMy WebLinkAboutENCODE - EVANS RESIDENCE - 11-11-2020-signedEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 410/8/2020 10:07 AM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction:
ST. LUCIE COUNTY
EVANS RESIDENCE
Street:
City, State, Zip: FT. PIERCE , FL ,
5911 BIRCH DRIVE
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
Existing (Projected
Single-family
1
No
1644
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=1.05 94.83 ft²
SHGC=0.25
Sgl, U=1.05 40.00 ft²
SHGC=0.30
N/A f t ²
N/A f t ²
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 1644.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Frame - Wood, Exterior R=19.0 1192.00 ft²
b. Frame - Wood, Adjacent R=11.0 296.00 ft²
c. N/A R=f t ²
10. Ceiling Types
a. Roof Deck (Unvented)R=19.0 1644.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Main
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 50 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:2.000 ft.
Area Weighted Average SHGC:0.265
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits Pstat
3
(134.8 sqft.)
(1488.0 sqft.)
(1644.0 sqft.)
(1644.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
32.8 SEER:16.00
Efficiency
k B t u / h r Efficiency
34.0 COP:1.00
f t ² R
6 225
EF: 0.950
Glass/Floor Area: 0.082
Total Proposed Modified Loads:
Total Baseline Loads:
41.88
48.83 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
10-8-2020
NOVMEBER 11, 2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
ST. LUCIE COUNTY
1
EVANS RESIDENCE
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle: 0
No
1
1644
3
Existing (Projected)
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
FT. PIERCE ,
St. Lucie
5911 BIRCH DRIVE
Street Address
Comment:
Building Type: User
Cross Ventilation:
Whole House Fan:
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Block1 1644 13152
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 Main 1644 13152 Yes 2 3 Yes Yes1 Yes
# Floor Type Area Tile Wood Carpet
FLOORS
R-ValueSpace Perimeter
1 1644 ft² 0 0 1______ Slab-On-Grade Edge Insulation - - - -0156 ft Main
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Composition shingles 1781 ft² Medium 0.6 19 22.6______ No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Unvented 1644 ft² N N0
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented) 30 1644 ft² 0.11 Wood______ Main Blown
10/8/2020 10:07 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 19 0Main 36 8W Frame - Wood 0.6000000.23Exterior 288.0 ft² ____
2 19 0Main 47 8N Frame - Wood 0.6000000.23Exterior 376.0 ft² ____
3 19 0Main 36 8E Frame - Wood 0.6000000.23Exterior 288.0 ft² ____
4 19 0Main 30 8S Frame - Wood 0.6000000.23Exterior 240.0 ft² ____
5 11 0Main 37 8N Frame - Wood 0.6000000.23Garage 296.0 ft² ____
# Door Type U-Value AreaStorms
DOORS
Ornt Space
Width
Ft In Ft In
Height
1 Wood .2 .1 ft² None______ N Main .1.1
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 W Low-E Single 1.05 0.3 20.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 1______ Yes1 N
2 W Low-E Single 1.05 0.25 17.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 1______ Yes1 N
3 N Low-E Single 1.05 0.25 17.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 1______ Yes2 N
4 N Low-E Single 1.05 0.25 17.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 1______ Yes2 N
5 N Low-E Single 1.05 0.25 6.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 1______ Yes2 N
6 E Low-E Single 1.05 0.25 17.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 1______ Yes3 N
7 E Low-E Single 1.05 0.25 6.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 1______ Yes3 N
8 S Low-E Single 1.05 0.25 2.8 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 1______ Yes4 N
9 S Low-E Single 1.05 0.25 12.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 1______ Yes4 N
10 E Low-E Single 1.05 0.3 20.0 ft² 2 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 1______ Yes3 N
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 312 ft² 312 ft² 37 ft 8 ft 11______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
1096 560.17.000254Wholehouse .0881113.16Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtype BlockSpeed
1 Electric Strip Heat/ COP:1 34 kBtu/hr ______ sys#1None 1
10/8/2020 10:07 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtype BlockSubtype
1 Central Unit/ SEER: 16 32.8 kBtu/hr 984 cfm 0.8______ sys#1None 1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.95 50 gal 60 gal 120 deg None______ None Garage
FSEC
Company Name System Model # Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert # Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply ---- ---- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 225 ft² Attic 40 ft² Default Leakage Main (Default) c______ 1 1 (Default) c
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078
Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878
Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 Main
10/8/2020 10:07 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction:
ST. LUCIE COUNTY
EVANS RESIDENCE
Street:
City, State, Zip: FT. PIERCE , FL ,
5911 BIRCH DRIVE
Permit Number:
Design Location: FL, Fort Pierce CHECKAIR BARRIER CRITERIA
A continuous air barrier shall be installed in the building envelope.
The exterior thermal envelope contains a continuous air barrier.
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
the insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall be sealed.
The junction of the top plate and the top of exterior walls shall be
sealed.
Knee walls shall be sealed.
The space between window/door jambs and framing, and
skylights and framing shall be sealed.
Rim joists shall include the air barrier.
The air barrier shall be installed at any exposed edge of
insulation.
Exposed earth in unvented crawl spaces shall be covered with
a Class I vapor retarder with overlapping joints taped.
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Narrow cavities
Shafts, penetrations
Crawl space walls
Floors
(including
above-garage
and cantilevered
floors)
Rim joists
Windows, skylights
Walls
Ceiling/attic
General
COMPONENT
Garage separation
Recessed lighting
Plumbing and wiring
S h o w e r / t u b
HVAC register boots HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub-floor or drywall.
The air barrier shall be installed behind electrical or communication
boxes or air-sealed boxes shall be installed.
The air barrier installed at exterior walls adjacent to showers and
tubs shall separate them from the showers and tubs.
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Recessed light fixtures installed in the building thermal envelope
shall be sealed to the drywall.
Air sealing shall be provided between the garage and conditioned spaces.
When required to be sealed, concealed fire sprinklers shall only be
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ceilings.
C o n c e a l e d
Electrical/phone box on
exterior walls
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
INSULATION INSTALLATION CRITERIA
EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software10/8/2020 10:07 AM Page 1 of 1
Air-permeable insulation shall
not be used as a sealing material.
The insulation in any dropped ceiling/soffit
shall be aligned with the air barrier.
Cavities within corners and headers of frame walls
shall be insulated by completely filling the cavity
with a material having a thermal resistance of R-3
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Rim joists shall be insulated.
Floor framing cavity insulation shall be installed to
maintain permanent contact with the underside of
subfloor decking, or floor framing cavity insulation
shall be permitted to be in contact with the top side
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
and doors
on exterior wall
requirements
Recessed light fixtures installed in the building
thermal envelope shall be air tight and IC rated.
sprinklers
Where provided instead of floor insulation, insulation
shall be permanently attached to the crawlspace
Exterior walls adjacent to showers and tubs shall
be insulated.
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 86
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. __________ Existing (Projected)
2. Single-family or multiple-family 2. __________ Single-family
3. No. of units (if multiple-family)3. __________ 1
4. Number of bedrooms 4. __________ 3
5. Is this a worst case? (yes/no)5. __________No
6. Conditioned floor area (sq. ft.)6. __________1644
7. Windows, type and area
a) U-factor:(weighted average)7a._________1.050
b) Solar Heat Gain Coefficient (SHGC)7b._________0.265
c) Area 7c._________134.8
8. Skylights
a) U-factor:(weighted average)8a._________NA
b) Solar Heat Gain Coefficient (SHGC)8b._________NA
9. Floor type, insulation level:
a) Slab-on-grade (R-value)9a._________0.0
b) Wood, raised (R-value)9b._________
c) Concrete, raised (R-value)9c._________
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)10A1.________19.0
2. Masonry (Insulation R-value)10A2.________
B. Adjacent:
1. Wood frame (Insulation R-value)10B1.________11.0
2. Masonry (Insulation R-value)10B2.________
11. Ceiling type and insulation level
a) Under attic 11a.________30.0
b) Single assembly 11b.________
c) Knee walls/skylight walls 11c.________
d) Radiant barrier installed 11d.________No
12. Ducts, location & insulation level
a) Supply ducts R_______6.0
b) Return ducts R_______6.0
c) AHU location Main
13. Cooling system: Capacity_______32.8
a) Split system SEER_______
b) Single package SEER_______
c) Ground/water source SEER/COP_______
d) Room unit/PTAC EER_______
e) Other __________16.0
14. Heating system:Capacity_______34.0
a) Split system heat pump HSPF_______
b) Single package heat pump HSPF_______
c) Electric resistance COP_______1.0
d) Gas furnace, natural gas AFUE_______
e) Gas furnace, LPG AFUE_______
f) Other
15. Water heating system
a) Electric resistance EF_______0.95
b) Gas fired, natural gas EF_______
c) Gas fired, LPG EF_______
d) Solar system with tank EF_______
e) Dedicated heat pump with tank EF_____
f) Heat recovery unit HeatRec%_______
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans _________
b) Cross ventilation _________No
c) Whole house fan _________No
d) Multizone cooling credit _________
e) Multizone heating credit _________
f) Programmable thermostat _________Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature:_________________________________________Date:____________________________________
Address of New Home: ____________________________________City/FL Zip: ________________________________5911 BIRCH DRIVE FT. PIERCE, FL
10/8/2020 10:07:30 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
NOVEMBER 11, 2020