HomeMy WebLinkAboutCompaction Testr In -Place Density Report Client: & Associates, Inc. Permit Number: 2010-0185 Report Date: 12/16/2020 Port St. Lucie Branch Test Method: ASTM D6938 Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone:772-878.0072 j I Renar Development Corp. 3725 S. East Ocean Boulevard, Suite 101 Stuart, FL 34996 ,10le, 4/ l85 Project: 113-15-66-5434B Morningside Residential Lots Fort Pierce Fort Pierce, FL Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (% Maximum Dry Density (pcf) In Place Moisture %) In Place Dry Density pcf) In Place Wet Density (pc Probe Depth in Percent Compaction Min Comp. (% Remark 398 12/8/20 20-311 (Modified) A -- 10.5 117.5 9.6 117.9 129.2 12 100 95 Pass 399 12/8/20 20-311 Modified A -- 10.5 117.5 10.4 116.7 128.8 12 99 95 Pass 400 12/8/20 20-311 (Modified) A 10.5 117.5 10.2 116.1 127.9 12 99 95 Pass 401 12/8/20 20-311 (Modified) A 10.5 117.5 11.3 117.3 130.6 12 100 95 Pass 402 12/8/20 20-311 (Modified) A - 10.5 117.5 11.1 116.4 129.3 12 99 95 Pass 403 12/8/20 20-311 Modified A - 10.5 117.5 11.3 115.7 128.8 12 98 95 Pass 404 12/8/20 20-311 Modified A 10.5 117.5 11.9 114.8 128.5 12 98 95 Pass 405 12/8/20 20-311 Modified A 10.5 117.5 10.6 116.1 128.4 12 99 95 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 398 House Pad - Pad Fill: Lot 114.324 Palm Breeze Drive. N Corner -1.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 399 House Pad - Pad Fill: Lot 114. 324 Palm Breeze Drive. W Corner -1.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 400 House Pad - Pad Fill: Lot 114. 324 Palm Breeze Drive. S Corner -1.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 401 House Pad - Pad Fill: Lot 114. 324 Palm Breeze Drive. E Corner -1.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 402 House Pad - Pad Fill: Lot 114. 324 Palm Breeze Drive. NE Footing -2.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 403 House Pad - Pad Fill: Lot 114. 324 Palm Breeze Drive. SE Footing -2.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 404 House Pad - Pad Fill: Lot 114. 324 Palm Breeze Drive. SW Footing -2.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 405 House Pad - Pad Fill: Lot 114. 324 Palm Breeze Drive. NW Footing -2.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie Remarks Comments Pass: Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL. fi-r In -Place Density Report Client: 8t Associates, Inc. Permit Number: 2010-0185 Renar Development Corp. 725 S E t O Bo levard Suite 101 Port St. Lucie Branch Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone:772-878-0072 Report Date: 12/16/2020 Test Method: ASTM D6938 3 . as cean u , Stuart, FL 34996 Project: 113-15-66-5434B Morningside Residential Lots Fort Pierce Fort Pierce, FL J' 11�N C+ N0. 6394 r srq OF 7 ir�r�oti This item has been digitally signed and sealed by Branch Manager Dan J. Zrallack, P.E. on Dec 16, 2020 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL.