Desgin pressure calcs
NewSouth WINDOW SOLUTIONS 2526 Okeechobee Blvd, West Palm Beach, FL 33409 • 561-712-9000 • CRC 1330822 Property Information Building Information Owner. Gary & Kay Morgan Wind Zone: 170 MPH. Address: 6000 Nettle Path Dr Exposure Category: C Fort Pierce, FL 34951 Minimum Building Dimension: 25 & Mean Roof Height: 15 ft. Risk Category: H Design Pressure Calculations Oenm Location Device Device Device Max Positive Max Negative g(psf) Numberr Zone Width (in) Height (in) Elevation (ft) Pressure (psf) Pressure I Int 25.50 37 7 37.8 41.0 2 Int 24.25 49.75 7 37.8 41.0 3 Int 23.50 49.75 7 37.8 41.0 4 Int 24.25 49.75 7 37.8 41.0 5 Int 25.50 49.75 7 37.8 41.0 6 Int 25.50 37 7 37.8 41.0 7 Int 52 49.75 7 36.4 -39.6 8 Int 52 49.75 7 36.4 -39.6 9 Int 25.50 37 7 37.8 -41.0 Prep®ed in =ordm m with: dSCE 7-10, Chapin 30. Windloads- Compowma and QaMng. 6th Editbn (2a 7) Florida euildmg Cade. Page 1 of I