HomeMy WebLinkAboutREV 2 12 15 2020 COMMENT RESPONSE HGI PSL
PERMIT NUMBER 2011-0374
REVISION 2 - 12 15 2020 BLDG DEPT COMMENTS/RESPONSE NARRATIVE
HILTON GARDEN INN PORT ST LUCIE - 8540 Commerce Centre Drive Port St. Lucir, Fl.
ADA SITE/FACILITIES SURVEY & CERTIFICATION / PERMIT CD's
C/O Joanne Lee - J.LEE INTERIORS LLC
4805 NW 58 Ave. Coral Springs F. 33067
Architect: Thomas Brown Architect (TBA)
Thomas H. Brown, Jr., Architect Fl, LA, SC, NC, GA. VA, OH, AR, NJ, MD,
TX, NM, MI &NCARB
5266 Pinto Way, Orlando, Fl. 32810
G.C: Ron Janis - Janis Services Inc. 209 S 3rd St Lantana fl. 561-582-3988
Project Name: ADA SITE/FACILITIES SURVEY & PERMIT CD's per J.LEE INTERIORS - HILTON GARDEN INN PORT ST. LUCIE, FL.
Proj No. / Date : TBA- 01 24 2020 - Jan. 24, 2020, May 01, 2020
REVISION 2: IDENTIFIED DELTA 2 12 15 2020 BLDG DEPT COMMENTS NARRATIVE
To Whom It My Concern,
Delta 2, 12 15 2020 BLDG DEPT COMMENTS
PLANS EXAMINER REVIEW INCOMPLETE Jpi, Inc-Andrew 12/2/2020
12/2/2020 Comment: 1) A0.01- TYPE IV CONSTRUCTION IS INCORRECT. "HOTEL" OCCUPANCY IS INCORRECT. (301.1, 601.1)
RESPONSE: A.001 CORRECTED TO TYPE OF CONSTRUCTION: TYPE IV PROTECTED.
OCCUPANCY: MIXED USE R-2 HOTEL / A-2 SMALL ASSEMBLY. THE BUILDING IS FULLY SPRINKLERED.
12/2/2020 Comment: 2) A-100, A-101- SHOW ACCESSIBILITY ON PLANS, CLEAR FLOOR SPACE AT DESK & SERVING AREAS. ([A]107.2)
RESPONSE: ACCESSIBILTY INDICATED ON SHEET A-200, A-201 & A-202 FOR ADA COMPLIANCE OF ALL ELEMENTS ELEMENTS.
12/2/2020 Comment: 3) A-001- PROVIDE THE LEVEL OF ALTERATION AND COMPLIANCE
METHOD. (301.1)
RESPONSE: A0.01 ADDED LEVEL 2 ALTERATION AND COMPLIANCE METHOD.
12/2/2020 Comment: 4) PROVIDE A LIFE SAFETY PLAN. ([A]107.2.1)
RESPONSE: A-200 LIFE SAFETY PLAN INDICATING MAX. DISTANCE TO AN EXIT, FIRE ALARM DEVICES AND OCCUPANCY LOAD.
12/2/2020 Comment: 5) PROVIDE CONSTRUCTION DETAILS FOR ALL WORK- I.E. WALL TYPES, CEILING ASSEMBLIES, PATCHING FLOOR FOR REMOVED PLUMBING, ECT. ([A]107.2.1)
RESPONSE: WALL TYPES; THERE IS ONLY ONE NON BEARING WALL BEING REMOVED AT THE "SHOP".
CEILING ASSEMBLIES: THERE IS ONLY A SMALL PORTION OF SUSPENDED ACOUSTIC TILE CEILING (LESS THAN 100 SQ. FT.) BEING REMOVED OR ADDED.
PATCHING FLOOR; THIS IS THE GROUND FLOOR. ANY PENETRATIONS AT THE SECOND FLOOR ARE COVERED BY ADDED SHEETS A8.01 & A8.02.
12/2/2020 Comment: 6) A-202- PROVIDE DIMENSIONS, SHOW ACCESSIBILITY STALLS, ACCESSORY MOUNTING HEIGHTS, & CLEAR FLOOR SPACE FOR DIAPER CHANGING TABLES. ([A]107.2.1)
RESPONSE: A-201 & A-202 ADDED ALL MOUNTING HEIGHTS AND CLEAR FLOOR SPACE @ FIXTURES.
12/2/2020 Comment: 7) PROVIDE FLAME & SMOKE SPREAD REQUIREMENTS FOR INTERIOR FINISHES. (801.1)
RESPONSE: A0.01 ADDED CLASS C FLAME AND SMOKE SPREAD REQUIREMENTS FOR FULLY AUTO SPRINKLERED BUILDING.
12/2/2020 Comment: 8) IDENTIFY FIRE SEPARATION (FIRE WALLS & PARTITIONS). PROVIDE UL ASSEMBLY (501.1).
RESPONSE: THERE ARE NO FIRE SEPERATIONS ON THE GROUND FLOOR.
TBA – ThomasBrownArchitect LIC AR 7661 - DATE: 12 15 2020
- Thomas H. Brown Jr.
______________________________________________________________________