HomeMy WebLinkAboutBuilding plans7 RIDGED POLYSTYRENE INSULATION
Tk:
IUUMR
2' RIDGED POLYSTYRENE INSULATION
wY#SXt 94 S.M.S. ro.C.
rSUTYL RUBBER SEAL
YL
BER
AL
EXTRUDED ALUM. AT L
EXTRUDED ALUM. ATTACH RAIL
Yd010H 1/4 SAPS 7O.C.
024 ALUM ROOF 2X1P.T.wffiW'W,S.
AERNNATCONNECTIONDE ETAIL CO TAB& PATIO ROOF: NHM ' R
ARE 61JIWEL I TO ANY d�RREC IONS
REQUIRED BY FIELD INSPECTORS THAT
.024ALUMRO. YBL#E�ry/N/g�ECES$A.RYINORDER TO
2' RIDGED POLYSTYRENE INSULATI� I
EXISTING MOBILE HOMER"
WI#1114&M.S. T O.C.
i BUM RUBBER SEAL
i rA
�r.024 ALUM ROOF FLASHING
wl#BIU 1/4 S.M.S S. O.C.
�BUWYL RUBBER SEA
PANS wf (2) 9 S.M.S. PER PAN
OWALUM.ATTAOI RAIL
M' X81(1 1N B.M.S. T O.C,
BUTYLRUBSERSEAL
024 ALUM FLASHING INTO PAN
MIDCAULKORCONRNUE
FLASHING TO GIITIER
248 SMS w/ NEOPRENE
WASHERS TO TOP OF EACH PAN
N41T�1M-a1 �11i1/
EXISTING
OVERHANG
E%ISRNGALUM. YSTRQIE FOAM
__,,, INSERT EACH PAN
NAN
.024ALUMRDOF wNNXt ll1 S.M.S.TO.C.
BMFELTONTOPOF BUTYL RUBBER SEAL
PANS
024ALI1M FLASHWO INTO PAN
AND CAOXORCONTIMIE
;_ FLASHING TO GUTTER
EXISTING PANS wl J
INSULATION INSERTS
2X3 P.T. BLOCKS CUT TO FIT 0
PANS wl P) IM S.M.S. PER PAN
2X3 P.T. BE CUT TO FR INTO "�K�4%i��, i
PANS wl 12)#e S.M.S. PER PAN ��`�' '..
ALTERNATE PATIO
EXISTING PANSw/ N.T.S.
FXISME COACH
INSULATION INSERTS
FRAME
EXISTING ALUM.
C0.1 BBEAM
BUTYL RUBBER
ALTERNATE COACH & PATIO ROOF ATTACHMENT #2 OVERLAPPING -
CONNECTION DETAIL(NTS) (w14th WALL) .024 ALUM ROOF
..." .024,.. ROOF CONT. OVER
F I RIDGE W/ FACTORY SEAMS ® 4r D.C.
024ALIMR
2• RIDGED POLYSTYRENE INSULATION
EACH PAN
MOSILEHOMEROOF SINGLEWIDE(NTS)
TYPICAL ROOF SECTION
N.T.S.
ISWIC STAINLESS STEEL HEX HEAD
FROM ATTACHMENT RAIL TO EXISTING
MOBILE HOME FRAME 0 S O.C. MIN.
INTO EXISTING FRAMING
118t1'WIDE BUM RUBBER CONI
.024 ROLL ALUMINUM
INSULATION
—.024 ALUM ROOF
1Y
Nm THBALTEWUiE
MIYKE TGOMWIN
FFFRAMsAwFB.TKHI
1'
aFHRu#NI
on
MAYB%m�
EIAT&IC
ANFA9MINAMWMHECTION
EXTRUDED ALUMINUM ATTACHMENT
RAIL w/#M1-1I1 STAINLESS STEEL
EXISTING MOBILE HPRE-PUNCHED
� OME I I SCREWS HED HOLES. O.C.
FRAMING 8 ROOFING
COBRNGAUM. `INERT EACH PAN OAM GUTTER EDGE DETAIL ALTERNATE ATTACHMENT RAIL FASTENING #1
COL S BEAM N.T S.
N.T.S.
4r .C.(TY) CLEAT
ATTACHMENT DETAIL "B" Cy\37 ee o.c.(rrP)
EXTRUDED ALUM. ATTACH RAIL
w/#8X11M SAS. TO.C.
�2X3P.T.w/M'
W.S®8'O.C.
.ON ALUM ROOF
r RIDGED POLYSTYRENE INSULATION FOAM FILLER
EXISTING MOBILE NICE ROOF EXTRIAEOAlINA ATTACH RAIL EXISTING CENTER CAP TINO COACH FR!
w/##X11/4SAS.70.C.
'7 BUM RUBBER SEAL DOUBLE WIDE RIDGE DETAIL
9
0249.UMaoaF
N.T.S.
FINSVIATION
EXISTING
FRAME
EXISTING PATIO ROOF
MAX SPAN N'6'
'ERED INSULATION AS REQUIRED
r RIDGED POLYSTYRENE INSULATION
OVERLAPPING.
.024 ALUM ROOF
EXTRIAEEAL M. ATTACH RAIL
wl#BRJ%S.M.S. 3' O.C.
P.T. WOOD BLOCKvd
#BKPW.S®SPANNNG
TO STRAIGHTEN WOOD ONLY
ALTERNATE COACH & PATIO ROOF ATTACHMENT #3 EXISTING CENTER CAP J �EXISTING COACH FRAMING
CONNECTION DETAIL(NTS) (NO DROP BETWEEN ROOFS) DOUBLE WIDE RIDGE DETAIL
USING ALTERNATE #1 ATTACHMENT (NITS)
MOBILE HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH EXPOSURE C
MINE
ATTACH CONT. 2Y4' P.T. TO EXISTING
J
MOBILE HOME FRAMING W1III WOOD
SCREWS ® SPATTING TO STRAIGHTEN
WOOD ONLY, IN LIEU OF FW. FRAMING
.024 ALUM GUTTER
ATTACHMENT PER DETAILS —
W/STRAPS@4'-0o.C.
ST. LI'C COLJ�TV RIIR n^` nnTSION
REVTFR'GDFOR COW LLA;'lCE
RaVILR'ED BY
DATE
Affilt PL,.ANS AND PERMIT MUST Bt KEPT ON JOD
*V*MfO INSPECTION WILL BE 5LkDE'
W#8X1114S.MS.ro.C.
-BUM RUBBER SEAL
D24ALUMFAMA
,"�'AT ADJACENT PATIO ROOF
PROVIDE A24 FLASHING
INTO PATIO RODF(MIN B')
wl#BsMsolro.C.
FASCIA EDGE DETAIL
N.T.S.
OWNER: ��h,(��Z)FI%_•
ADORESS' Ate) �•PT t
CTTY'!TSQ%.: (71" STATE:'
LOT# \ 03 -t BLOCK#
STYRENE-BUTADIENE
FACTORY SEAM DESIGN FOR RUBBER SEALANT
ALUMINUM ROOF COVERINGS BETWEEN SHEET & CLEAT
OVER SOLID ROOFS ONLY PRODUCT APPROVAL #FL5739
N.T.S.
NOTES:
1.) THIS DESIGN CONFORMS TO THE 2014 FLORIDA BUILDING CODE FOR A
CATEGORY B BUILDING FOR WIND LOADING OF 185 MPH, EXPOSURE C AS
DETERMINED BY ASCE STANDARD 7.
2.) THIS DESIGN CONFORMS TO FLORIDA STATUTE 15G2.0081 FOR
MOBILEIMANUFACTURED HOME REPAIR AND REMODELING.
3.) ALUMINUM ROOFING IS DESIGNED FOR USE OVER A SOLID ROOF ONLY. IT
SHALL NOT BE USED AS A STRUCTURAL ROOF SYSTEM.
4-) THE ROOF COVERING SHALL NOT OVERHANG THE EXISTING ROOF.
5.) ENGINEER IS NOT RESPONSIBLE FOR STRUCTURAL INTEGRITY OF EXISTING
ROOF, THE STRUCTURE OF THE EXISTING ROOF SHOULD BE ABLE TO
SUPPORT THE CONSTRUCTION LOADING FOR THE NEW ROOF SYSTEM.
6.) MAXIMUM WIDTH OF A SINGLE WIDE MOBILE HOME NOT TO EXCEED 14'-0.
7.) MAXIMUM WIDTH OF A DOUBLE WIDE MOBILE HOME NI EXCEED 28'-0
8.) INSULATION TO BE POLYSTYRENE FORM APROX. DENSITY"1# PER S.F.
#.) MAXIMUM HEIGHT OF MOBILE HOME NOT TO EXCEED 160..
10.) MINIMUM THICKNESS OF ALL ROOF FLASHING TO BE .024 ALUM.
11.) THE R•VALUE OF THE 2' EPS INSULATION IS R=8.7.
SHEET No.: $1 Of 2
CC-L O V L7 k V NOT VALID UNLESS DATED
&5ES
WITH M9
L �v E
ZIP.3y4S/%Q
IS
JS
RANGE PROFESSIONAL ENGINEER 20311
STATE OF FLORIDA
w
o
17p
b
a
q
m
�
Io
f
y
c
1b
w
M
TO
W
Eptl
4b
co
N
a
Gi
co
V4N
C3
41
N ID
f� N
O
O � 4
O
I>a N
N m
ril �Qm
'f 404
yO
co
Vq
OWN
N
Om
2�W
hR�
Z
4
Z IY
U
T MIN THICKBONDED PANEL—'
NOTE:
MAX 17 SPAN BONDED PANEL
EXISTING ALUM.
COL. & BEAM
OR FRAMING
BONDED
N.T.S.
w/#BX11/4 S.M.S. 3' O.C.
,BUTYL RUBBER SEAL
2` r PT wl 010F TEX SCREWS ® r O.C. THRU
BONDED PANEL INTO EXISTING BEAM
024 ALUM FLASHING
_
/— EXTRUDED ALUM. ATTACH RAIL
w118%1114 S.M.S. T O.C.
EDGE DETAIL #2
.024 ALUM RASHM
EXTRUDED ALUM. ATTACH
w/ #8X1 114 S.M.S. X O C.
12'x12'x.024 ALUM CAP —
PARK MODEL DETAIL A
N.T.S.
EXTRUDED ALUM. ATTACH RI
w/#8X1 114 S.M.S. 3' O.C.
12'x12'x.024 ALUM CAP
LAP OF ROOF ROLL TO BE ON _
DOWNWARD SIDE
.024 ALUM ROOF
7 RIDGED POLYSTYRENE EXTRUDED ALUM. ATUCH RAIL PARK MODEL DETAIL B
INSULATION w11BX71M S.M.S.3'OC. N.T.S.
' � j� ' BUM RUBBER SFAL
�i � �.024 ALUM PUSHING
2*x4' PT CONT. w/ #8x3' WOOv SCREWS @ 8'
O.C. TO RIDGE BEAM & 14/84' WOOD
SCREW TO EACH TRUSS
RIDGED POLYSTYRENE INSULATION
—27c4' WOOD TRUSS
24'O.C. w/ 112' SHEATHING
EXTRUDED ALUM. ATTACH RAIL
w/,#8X1 1/4 S.M.S. 3' O.C.
a% A%J,l j je
BUTYL RUBBER SEAL
SEE GUTTER 8
FASCIA EDGE
DETAILS, S-1
j
2x4 P.T. w/ #ex3'WOOD SCREWS
MAX 18' O.H. --�
0 B' O.C. TO FASCIA w/ 148x3'
TO EACH TRUSS TAIL 0 24'O.C.
CONTINUOUS
2' FASCIA TYP.
YL RUBBER SEAL
2k4' PT CONT. w/ 24 &Y WOOD SCREWS TO EACH TRUSS
2' RIDGED POLYSTYRENE INSULATION
/-2'0' WOOD TRUSS 0
/ 24'O.C. w/IZ SHEATHING
RUDED ALUM. ATTACH RNL
w/#BX1 1/4 S.M.S. 3' O.C.
UTYL RUBBER SEAL
SEE GUTTER&
FASCIA EDGE
j
2.0 P.T. w/#8x3'WOOD SCREWS
MAX 18' O.H.
0 12' O.C. TO FASCIA w/ 146x3'
TO EACH TRUSS TAIL ® 24'0C.
CONTINUOUS
2' FASCIA TYP.
TMIN THICK BONDED PANEL •�//////��/jjj ( 2-0 PTrd i®q'SMS®/'NTO
NOTE: EXTRUDED METAL &BONDED PANEL -
MAX I7SPAN BONDED PANEL /
/ 1'MAX O.H.
.032 EX/FWDED FASCIA
EXISTING ALUM. j WETIING OR GUTTER
COL & BEAM
OR FARMING SHEET No.: SZ Of 2
OWNER: NOT UNL SS DAT
BONDED PANEL ROOF EDGE DETAIL #1 \ ADDRESS: DWI E
N.T.S. E �
CRY: STATE: 21P: ES BUSHOUS , P.E./"
MOBILE HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH EXPOSURE C LOT# BLOCK# RANGE: PROFESSIONAL ENGINEER 20311
STATE OF FLORIDA