HomeMy WebLinkAboutFL NOA 20-0519.09 FW NOA No. 20-0519.09
Expiration Date: September 22, 2025
Approval Date: October 10, 2020
8/31/20 Page 1
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/building
CGI Windows and Doors, Inc.
3780 W 104th Street
Hialeah, FL 33018
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform
in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right
to revoke this acceptance if it is determined by Miami-Dade County Product Control Section that this product
or material fails to meet the requirements of the applicable building code.
This product is approved as described herein and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: Series “Sentinel 130" Aluminum Fixed Window – L.M.I.
APPROVAL DOCUMENT: Drawing No. PW130LMI-NOA, titled “‘Sentinel’ Series 130 Fixed Window -
LM”, sheets 1 through 7 of 7, dated 05/22/19, with revision A dated 05/07/20, prepared by manufacturer,
signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami-Dade County Product Control Revision
stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control
Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises and renews NOA# 19-0603.02 and consists of this page 1 and evidence pages E-1, E-2,
E-3, E-4 and E-5, as well as approval document mentioned above.
The submitted documentation was reviewed by Manuel Perez, P.E.
Manuel Perez, P.E.
Product Control Examiner
NOA No. 20-0519.09
Expiration Date: September 22, 2025
Approval Date: October 10, 2020
E - 1
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA’s
A. DRAWINGS
1. Manufacturer's die drawings and sections.
(Submitted under NOA No. 10-0510.13)
2. Drawing No. PW130LMI-NOA, titled “Sentinel 130 Alum Fixed Window
(L.M.I.)(S.M.I.)”, sheets 1 through 7 of 7, dated 05/22/19, prepared by manufacturer,
signed and sealed by Anthony Lynn Miller, P.E.
(Submitted under NOA No.19-0603.02)
B. TESTS
1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked-up drawings and installation diagram of a series 560 aluminum
sliding glass door, prepared by Fenestration Testing Laboratory, Inc., Test Report No.
FTL-19-8916, dated 04/10/19, signed and sealed by Idalmis Ortega, P.E.
(Submitted under NOA No.19-0603.02)
2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
2) Water Resistance Test, per FBC, TAS 202-94
3) Small Missile Impact Test per FBC, TAS 201-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked-up drawings and installation diagram of a series 130 and 410
aluminum fixed windows, prepared by Fenestration Testing Laboratory, Inc., Test
Report No. FTL-19-8917, dated 04/09/19, signed and sealed by Idalmis Ortega, P.E.
(Submitted under NOA No.19-0603.02)
3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked-up drawings and installation diagram of a series 7500 PVC fixed
window, to qualify DuPont “Butacite” PVB interlayer, Duraseal® and Super Spacer®
insulating glass spacer, prepared by Certified Test Laboratories, Test Report No.
CTLA–3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E.
(Submitted under NOA No.15-0413.03)
Manuel Perez, P.E.
Product Control Examiner
NOA No. 20-0519.09
Expiration Date: September 22, 2025
Approval Date: October 10, 2020
E - 2
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA’s (CONTINUED)
B. TESTS (CONTINUED)
4. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked-up drawings and installation diagram of a series 7400 PVC project
out window, to qualify DuPont “Butacite” PVB interlayer, Duraseal® and Super
Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report
No. CTLA–3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E.
(Submitted under NOA No.15-0413.03)
5. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked-up drawings and installation diagram of a series 238 aluminum fixed
window, to qualify DuPont “Butacite” PVB interlayer, Duraseal® and Super Spacer®
insulating glass spacer, prepared by Certified Test Laboratories, Test Report No.
CTLA–3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E.
(Submitted under NOA No. 15-0413.03)
6. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Small Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked-up drawings and installation diagram of a Sentinel 130 aluminum
fixed window, prepared by Hurricane Test Laboratory, Test Report No.
HTL 0080-0130-10, dated 03/30/10, signed and sealed by Vinu J. Abraham, P.E.
(Submitted under NOA No.10-0510.13)
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 6th
Edition (2017), dated July 15, 2017, prepared by Al-Farooq Corporation, signed and
sealed by Javad Ahmad, P.E.
(Submitted under NOA No.17-0918.07)
2. Glazing complies with ASTM E1300-09.
D. QUALITY ASSURANCE
1. Miami-Dade Department of Regulatory and Economic Resources (RER)
Manuel Perez, P.E.
Product Control Examiner
NOA No. 20-0519.09
Expiration Date: September 22, 2025
Approval Date: October 10, 2020
E - 3
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA’s (CONTINUED)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 17-0808.02 issued to Kuraray America, Inc. for their
“SentryGlas® (Clear and White) Glass Interlayers” dated 12/28/17, expiring on
07/04/23.
2. Notice of Acceptance No. 17-1114.14 issued to Kuraray America, Inc. for their
“Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers” dated 01/18/18,
expiring on 07/08/19.
3. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA)
for their “Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET
Core” dated 05/17/18, expiring on 12/11/23.
4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA)
for their “Saflex Clear and Color Glass Interlayers” dated 09/07/17, expiring on
05/21/21.
F. STATEMENTS
1. Statement letter of conformance, complying with FBC 6th Edition (2017), dated May
23, 2019, issued by manufacturer, signed and sealed by A. Lynn Miller, P.E.
(Submitted under NOA No.19-0603.02)
2. Statement letter of no financial interest, dated May 23, 2019, issued by manufacturer,
signed and sealed by A. Lynn Miller, P.E.
(Submitted under NOA No.19-0603.02)
3. Proposal No. 19-0219 issued by the Product Control Section, dated March 13, 2019,
signed by Ishaq Chanda, P.E.
(Submitted under NOA No.19-0603.02)
4. Notification of Successor Engineer for manufacturer’s NOA document per Section
61G15-27.001 of the Florida Administrative Code, notifying original engineer that
the successor engineer is assuming full professional and legal responsibility for all
engineering documents pertaining to this NOA, dated May 22, 2019, signed and sealed
by A. Lynn Miller, P.E.
(Submitted under NOA No.19-0603.02)
5. Laboratory compliance letter for Test Report No. HTL-0080-0103-10, issued by
Hurricane Test Laboratory, LLC, dated March 30, 2010, signed and sealed by Vinu J.
Abraham, P.E.
(Submitted under NOA No.10-0510.13)
6. Test Proposal for the qualification of Butacite® PVB glass interlayer by Kuraray
America, Inc., as well as Duraseal® and Super Spacer® Standard warm-edge
flexible insulating glass spacers, dated December 16, 2014, issued by RER, Product
Control Section, signed by Jaime Gascon, P.E., Supervisor, Product Control Section.
(Submitted under NOA No. 15-0413.03)
Manuel Perez, P.E.
Product Control Examiner
NOA No. 20-0519.09
Expiration Date: September 22, 2025
Approval Date: October 10, 2020
E - 4
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA’s (CONTINUED)
G. OTHERS
1. Notice of Acceptance No. 17-0918.07, issued to CGI Windows and Doors, Inc. for
their Series “Sentinel 130” Aluminum Fixed Window - L.M.I. approved on 11/22/17
and expiring on 09/22/20.
2. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. PW130LMI-NOA, titled “‘Sentinel’ Series 130 Fixed Window - LM”,
sheets 1 through 7 of 7, dated 05/22/19, with revision A dated 05/07/20, prepared by
manufacturer, signed and sealed by Anthony Lynn Miller, P.E.
B. TESTS
1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per ASTM F588 and TAS 202-94
along with marked-up drawings and installation diagram of all PGT Industries, Inc.
CGI Windows and Doors, Inc., representative units listed below and tested to qualify
Dowsil 791 and Dowsil 983 silicones, per Proposal #19-1155TP, prepared by
Fenestration Testing Laboratory, Inc., Test Reports No.:
PGT Industries, Inc. test specimens:
FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14
FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal)
FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal)
FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and
FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal)
all dated 07/13/20 and signed and sealed by Idalmis Ortega, P.E.
CGI Windows and Doors Inc. test specimens:
FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit 1 in proposal)
FTL-20-2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal)
FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal)
FTL-20-2108.4, CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and
FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal)
all dated 08/24/20 and signed and sealed by Idalmis Ortega, P.E
Manuel Perez, P.E.
Product Control Examiner
NOA No. 20-0519.09
Expiration Date: September 22, 2025
Approval Date: October 10, 2020
E - 5
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. NEW EVIDENCE SUBMITTED (CONTINUED)
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 6th
Edition (2017), dated 07/15/17, prepared by Al-Farooq Corporation, signed and
sealed by Javad Ahmad, P.E., updated to comply with FBC 7th Edition (2020), on
05/11/20 by manufacturer, signed and sealed by Anthony Lynn Miller, P.E.
D. QUALITY ASSURANCE
1. Miami-Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 18-0725.11 issued to Kuraray America, Inc. for their
“Kuraray SentryGlas® XtraTM (SGXTM) Clear Glass Interlayer” dated 05/23/19,
expiring on 05/23/24.
2. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their
“Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers” dated 05/09/19,
expiring on 07/08/24.
3. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA)
for their “Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET
Core” dated 05/17/18, expiring on 12/11/23.
4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA)
for their “Saflex Clear and Color Glass Interlayers” dated 09/07/17, expiring on
05/21/21.
F. STATEMENTS
1. Statement letter of conformance, of complying with FBC 6th Edition (2017), and
FBC 7th Edition (2020), dated May 07, 2020, issued by manufacturer, signed and
sealed by Anthony Lynn Miller, P.E.
2. Statement letter of no financial interest, dated May 07, 2020, issued by manufacturer,
signed and sealed by Anthony Lynn Miller, P.E.
3. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10,
2020, signed by Ishaq Chanda, P.E.
G. OTHERS
1. Notice of Acceptance No. 19-0603.02, issued to CGI Windows and Doors, Inc. for
their Series “Sentinel 130” Aluminum Fixed Window - L.M.I. approved on 07/03/19
and expiring on 09/22/20.
PRODUCT REVISED as complying with the Florida Building Code NOA–No. 20-0519.09 Expiration Date: 09/22/2025 By:________________________ Miami–Dade Product Control
PRODUCT REVISED as complying with the Florida Building Code NOA–No. 20-0519.09 Expiration Date: 09/22/2025 By:________________________ Miami–Dade Product Control
PRODUCT REVISED as complying with the Florida Building Code NOA–No. 20-0519.09 Expiration Date: 09/22/2025 By:________________________ Miami–Dade Product Control
PRODUCT REVISED as complying with the Florida Building Code NOA–No. 20-0519.09 Expiration Date: 09/22/2025 By:________________________ Miami–Dade Product Control
PRODUCT REVISED as complying with the Florida Building Code NOA–No. 20-0519.09 Expiration Date: 09/22/2025 By:________________________ Miami–Dade Product Control
PRODUCT REVISED as complying with the Florida Building Code NOA–No. 20-0519.09 Expiration Date: 09/22/2025 By:________________________ Miami–Dade Product Control
PRODUCT REVISED as complying with the Florida Building Code NOA–No. 20-0519.09 Expiration Date: 09/22/2025 By:________________________ Miami–Dade Product Control