HomeMy WebLinkAboutNettles Island Engineer LetterDwTg4fTPAWS A-ee4frrZ6T, P.A. Flnnda license hAR001608 1045 S.E. Riverside Drive Stuart, Florida 34996 (772)781-6695 December 15, 2020 St. Lucie County Building Department Fort Pierce, Florida I3E: Nettles Island Club House 9801 South Ocean Drive Jensen Beach, Florida To whom it may concern: The design pressures (PSF) for the above location to replace (12) fixed windows below 30' roof height are as follows: ZONE 4 - +48.9 -50.7 ZONE 5 - +48.9 —64.7 Zone 5 is defined as 5' of building wall from building comers. Zone 4 is defined as all other wall space. Design pressures calculated with 165 mph ultimate design wind speed and 128 nominal wind speed, importance factor 1.0, exposure D, surface exposure D, category II, internal pressure coefficient +. 18, -18. Sincerely, Dwight Davis AIA