Loading...
HomeMy WebLinkAboutAPPROVED, EngineeringFlorrda license #AR0016908 1045 S.E. Riverside Drive Stuart, Florida 34996 (772) 781-6695 December 15, 2020 St. Lucie County Building Department Fort Pierce, Florida RE: Terry Residence 2546 NW Seagrass Drive Palm City, Florida 34990 To whom it may concern: The design pressures (PSF) for the above location to replace (2) horizontal windows and (1) sliding glass doors at the second floor (30' roof height) are as follows: ZONE 4 - +46.0, -49.8 ZONE 5 - +46.0 —61.4 Zone 5 is defined as 5' of building wall from building corners. Zone 4 is defined as all other wall space. Design pressures calculated with 160mph ultimate design wind speed and 124 nominal wind speed, importance factor 1.0, exposure D, surface exposure D, category li, internal pressure coefficient +.18, -18. Sincerely, Dwight Davis AIA