HomeMy WebLinkAbout5711 eastwood final HD H APPLICATION #:AP1433134
$ STATE OF FLORIDA PERMIT #:56-SF-1948918
DEPARTMENT OF HEALTH
DOCUMENT #:F11554554
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:09/12/2019
we '
FEE PAID:305.00
RECEIPT #:56-PI D-4128051
APPLICANT: Wade Jurney Homes, LLC
AGENT: Wade Jurney Homes, LLC
PROPERTY ADDRESS: 5711 Eastwood Dr Fort Pierce, FL 34951
LOT: 6 BLOCK: 138
SUBDIVISION: Lakewood Park ID#: 1301-61-0041-000-8
CHECKED [X3 ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION SETBACKS
[ ) [013 TANK SIZE [13 900.00 [21 [ 3 [271 SURFACE WATER FT
[ 3 [021 TANK MATERIAL Concrete [ 3 [281 DITCHES FT
[ 3 [031 OUTLET DEVICE [ 3 [291 PRIVATE WELLS 75 FT
[ 3 [041 MULTI-CHAMBERED [L_jj N 3 [ 3 [301 PUBLIC WELLS FT
[ 3 [053 OUTLET FILTER PolylokPL-68 [ 3 [313 IRRIGATION WELLS FT
[ 3 [06) LEGEND 1. 28-015-04DC3 2. [ 3 [32) POTABLE WATER 47 FT
[ 3 [07) WATERTIGHT [ 3 [333 BUILDING FOUNDATIONS 15 FT
[ 3 [081 LEVEL [ 3 [341 PROPERTY LINES 5 FT
[ ) [093 DEPTH TO LID [ 3 [351 OTHER FT
DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM
[ 3 [103 AREA [13 375 [23 SQFT [ 3 [363 DRAINFIELD COVER
[ 3 [113 DISTRIBUTION BOX HEADER X [ 3 [371 SHOULDERS
[ 3 [121 NUMBER OF DRAINLINES 1. 4.00 2. [ ) [381 SLOPES
[ 3 [133 DRAINLINE SEPARATION [ 3 (391 STABILIZATION 12/09/2020
[ 3 [143 DRAINLINE SLOPE
[ 3 [151 DEPTH OF COVER ADDITIONAL INFORMATION
[ 3 [163 ELEVATION [ ABOVE / BELOW IBM 8.00 [ 3 [401 UNOBSTRUCTED AREA
[ 3 [173 SYSTEM LOCATION [ 3 [413 STORMWATER RUNOFF
[ 3 [183 DOSING PUMPS [ 3 [42) ALARMS
[ 3 [191 AGGREGATE SIZE [ 3 [431 MAINTENANCE AGREEMENT
[ 3 [203 AGGREGATE EXCESSIVE FINES [ 3 [44) BUILDING AREA
[ 3 [211 AGGREGATE DEPTH [ 3 [453 LOCATION CONFORMS WITH SITE PLAN
FILL / EXCAVATION MATERIAL [ 3 [461 FINAL SITE GRADING
[ 3 [223 FILL AMOUNT [ 3 [471 CONTRACTOR Bruce T Mc Cullers (Reliable T
[ 3 [231 FILL TEXTURE [ 3 [481 OTHER ADS MPS-9(9 pipes-2 tier)
[ 3 [241 EXCAVATION DEPTH ABANDONMENT
[ 3 [253 AREA REPLACED [ 3 [49) TANK PUMPED
[ 3 [263 REPLACEMENT MATERIAL [ 3 [501 TANK CRUSHED & FILLED
Comments: Comments are on page 2.
CONSTRUCTION I APPROVED / St. Lucie CHD DATE: 11/10/2020
DISAPPROVED )' Enviro entaI specialist II r' J Ingram(ENVIRONMENTAL HEALTH)
FINAL SYSTEM [ APPROVED / DISAPPROVED 3: � St. Lucie CHD DATE: 12/09/2020
Environmental Specialist rian J Ingram(ENVIRONMENTAL HEALTH)
(Explanation of Violations on following page)
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1433134 E101948918
APPLICATION #:AP1433134
STATE OF FLORIDA PERMIT #:56-SF-1948918
DEPARTMENT OF HEALTH DOCUMENT #:FI1554554
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
�c CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:09/12/2019
WEIFEE PAID:305.00
RECEIPT #:56-PI D-4128051
Violation Number Comment
Comments
The system is sized for 3 bedrooms with a maximum occupancy of 6 persons(2 per bedroom),for a total estimated flow of 300
gpd.
New ST,filter and DF installed. No violations. System ok to cover. Contractor notified onsite. Needs final inspection for mound
system gutters,and final site grading.
Final system approved. Contractor and building department emailed final approval.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1433134 EID1948918