Loading...
HomeMy WebLinkAboutCertification for Design Load Compliancew- L C Planning & Development Services Department H mE Building & Code Regulations Division o �� 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 F� Certification for Design Load Compliance Project Name: T C A P 70 Project Address: 157371 -PA y 0 1.5r f � � �. Lc+�re � �L 311y87 Permit #: Occupancy Type: Construction Type: ICr lCol/c re�-- INSTRUCTIONS FOR USE: This certification must be completed, signed, and sealed by the design professional of record. Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residence° '(single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Code Sixth Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: I X II 111 Iv Exposure Category: B X g C D 4. Design Wind Velocity, 165 mph ASD X LRFD End Zone Width: 12 ft 5. Mean Roof Height 35' ft Roof Pitch: varies :12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: See Roof Zone 2: See Roof Zone 3: See Roof Zone 4: +38/-42 Zone 5: +40/-70 Garage: +32/-36 7. Design Loads: Floor.40 PSF Roof/Dead:20 PSF Roof/Live: 20 Balcony:40 PSF Dock: PSF Deck:40 PSF Stairs:40 PSF Fence: n/a PSF Railings: n/a PSF 8. Were Shear Walls Considered For Structure?-X--Yes Not Applicable Explain Why Not: Note: All ICF Walls are Shear Walls '9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also c t structural elements depicted on these plans provide adequate resistance to the design forces s p/v �! eRobert F Oleck UCFti Print Name Cert # & Co. Cert Auth. FI PE# 52514; CA# 30021 Revised 0 R.F.Oleck,lnc.1219 Scarlet Oak Loop, Winter Garden, FL Company Name & Address