Loading...
HomeMy WebLinkAboutBuilding Plansc i 69'-4"" 38'-4" 5,_1„ 4'-5" 12'-6" 16'-10" ! 4'-7" 2'-9" 16" T-1' T-1 , 1„ 16" T-3'" 11'-9"' 16" 3'-9" 3'-3" 16" (4) Risers at 7 (3) Treads at 11 L-14 L-16 L-14 Cone. mm ---- ---, °° - - ----------- ------ __ mm mo Steps ----- ----- ❑ o b I I I I 1 > Porch > , L-15 10'-0"Ceilin gI I 1 b 00 o from F.F.E. I L- 55 I I 1 o Concrete Sidewalk I I I I moICOJ 24 I 1 1I 6080 French with Sidelights �. a s.h. LL LL outdoor .. L_4 m m m mm mm mm oo mm mimic m AC Cond. Shower on cone. 10'-0'" �' w d vent 2880i ecI pad Cing. N thn 10'-0" Ceiling N 10'-0- Ceilin g 3'-8" 2'-0Safe, wau 10'-0' 12-0"' 111'30" — — — — 1T-10"" — — — 11'-0' Ceiling � '10 Pump O ^ Lnd. Dining I g Ceilin g 12'-0" `� o I Master Bdrm. m I-J 1o'-o"cng. 10'-0"Ceiling I I i b I 110'-0"Ceiling & 12"Coffer L-7 m O [:�04 O co WTw.. 3'-1'" 3'-8" 3'-6" i 72"x 20" z I a.h. 2 x 4 Frame I 2'-0" 2 _p" Fixed ❑ wall at 40.5'" Glass o Bollard 2680 I I Hdr. at tall I I o M Cing. 8-0 ----- I I 6'-10'" 3,_51 7,-7„Bo ❑ — — — — - - Golf Cart I I dw I Living Room I — L-8 1 10'-0'"Ceilin o y P' Wall I I �\ d I o 10'-0"'Ceiling & I I O from F.F.E. 00 o N U Oven \� 12""Coffer N N 1 o I cc o I❑ m 2680 a oM • ;, i�l '.. iCook Top & Xhaust Kitchen M r` c 00 00 ❑ o`' O.1p I ooCone. 10 -0"Cellig 2680`" Pocket Ni "I I 4-9"13-11 Steps -0- volo � T 12 -2" 15'-4" 4'-8"" T-3" T-0" o 2„ 2„ '--,(4) Risers at 7" ih 10'-0" j I I -(q) Treads at I " 1 I I I Cing. II 22 x 54 access I L---------- 10 -0 Cing. Temp. Glass 27„x 27,,Provide.R1I with Ladder water on 30"'Tall Batt in Adj: fine ^ I --� �o U Wall ' Fixed GlassMWalls eInsulation L. ® 22x36 O I N I I Access I i. 27"x 27„ I _ I N �60 I I I --Fixed � Glass co L 99 1 22'-0" v 9 -3 2 -7 I I 3'- ' v 8'-4' 3 6"' 4 '-8"' 1'- ' N 6'-6"' � 3'-11'" l Garage 28 i $drOat 0 II I r� 0� �, I 90 N T 2x 5� L-6 a I 10'-0"'Ceilin g I I— —, — — — — I —i ❑• m m 1 v from F.F.E. F. 27"x "" 27 Fixed L-5 t 0� ih 10'-0"Ceiling Glass oo Bedro m 2 tc. I L-2 a Study o ° m 10'-0"C fling ❑• m cc m 10'-O"Ceiling 00 0 N m m 2 6 L-1 m m L_1 E*7 26m I T-O" 2' 0"' 5080 o I d1cluawi 2' 0" IT-O" 5080 8 ❑ 3'-4- 2'-8" o s.h. s.h.Ln N m I ❑ O m m mi m m m Elm m m 26 s.h. Egress L-1 I L-1 26 s.h 26 s.h. 26 s.h. l Egress L} 1 L-1 I 5/12 Pitch Egress Egress Ent I lted I Caeiing 10'-0"Ceiling I j o L-11 I I 10' -0"C iling I from F.F.E. L-11 of 1 from F.'-.E. ( I m- - - - - - - --- m - -- - - - - - - JI m------- -,-- m ---------- I He �-(Ym t # 201 Project Data Building Code Project: Linda G. O'Quinn 6th Edition Florida Building Code: Residential Street Address: T.B.D. City: Ft. Pierce 2014 National Electric Code NFPA 70 I. RECEIVED County: St. Lucie Area Tabulation 0- � �' DEC 11 1020 Department State: Florida O 'X N 00 Permitting St. Lucie CeuntY Scope of Work Living 1941 L.Lu (� z M Garage 636 J New one level CBS single family Porch 384 LO to residence Entry 285 W w L c�lo Design Loads Total 3246 n. Lp 00 Roof Live Load: 20.0 p.s.f. Total Cubic Volume: 20,146 c.f.. -� J Q Li 0, N - Floor Live Load: N.A. z v Wind Speed: 160 MPH CL Wind Importance Factor. 1.0 V w m Building Category: II' p Wind Exposure: C J Internal Pressure Coefficent: .18 w CD Structure Designed: Enclosed ; Soil bearing capacity: 2000 p.s.f. VJ Cast Crete Lintel Schedule All Reber to be #5 Grade 60 mina ICU MARK LENGTH OF LINTEL ALLOWABLE-. '.. GRAVITY LOAD APPLIED GRAVITY LOAD ALLOWABLE UPLIFT LOAD APPLIED UPLIFT LOAD BEAM SPECS. L-1 4'-6- 8672 1048 4292 679 8F24-1B/1T L-2 T-8" 3129 1107 1640 656 8RF22-1B/1T L-3 14'-2" 1902 1235 968 730 8F22-1B/2T L-4 4'-2"" 8060 625 4409 364 8RF22-1B/1T L-5 3'-8" 8974 102 4853 101 8F24-1B/1T L-6 T-4" 8974 133 5591 109 8F24-1B/1T L-7 T-4" 2661 154 ,, 1634 125 8F16-1B/1T L-8 T-4" 6472` '. 188+ 3508 139 8F52-1B/1T L-9 1T-4" 2047 188 872 139 8F52-1B/1T L-11 6'-8" 2661 151 1634- 125 8F16-1B/1T L-12 8'-4" 1843 154 1133 114 8F16-1B/4T L-14 8'-4- 1843 159 1133 158 8F16-1B/1T L-15 10'-0" 1843 47,9 1133 380 81716-18/2T L-16 20'-4" 598 113 306 134 8F16-1B/1T Min. Beam depths shown, beams may be increased' without comment At Lintels over 24" deep provide (1) #3 vertical rebar at 24"o.c. along length of lintel �5n.�°a<u read.' Safe Load Table Notes puenily � %5 rebar �- �a°ryvmaf0o"I 1. All values based on minimum 4" nominal bearing. _ F-filled pout Exception: Safe loads for unfilled U lintels must m ( be reduced by 20% if bearing length is less than 61/2-. 8F16-1B/1T 2.N.R.=Not Rated ' °ta 3. Safe loads are superimposed allowable loads. 7 ab b ttom ra .atop a�a*^ 4. One #7 rebar may be substituted for two #5 e "°mil"el rebar in 8 inch U lintels only. Lintel Type. Designation 5. All safe loads in units of pounds per linier foot. 6. All safe loads are based on simply supported span. Composite U Lintel Materials p 7. Safe load ratings based on rational design analysis ACL318 ACI 530. per and 1. Grout per ASTM C476 fg=3000:psi with maximum 3/8 inch aggregate and 8 to 11 inch slump. Installation Notes 2. Reber per ASTM A615 Grade 60 3. Concrete masonry units (CMU) per ASTM C90 with 1. Installation of U lintels must comply with architectural and/or structural drawings. minimum net area compressive strength = 1900 psi - 4. Mortar per ASTM C270 Type M or S 2. U lintels can be field cut to the required length. 3. Cast in place concrete may be provided in composite U lintel in lieu of concrete masonry units. 4. The exterior surface of U lintels installed in exterior concrete masonry walls shall have a coating of stucco applied in accordance with ASTM C-926 or other - approved coating. 5. Concrete masonry units used in composite U lintel shall be laid in a running bond. 6. Shore composite lintels as required. 7. U lintels are manufactured with a 5 1/2- long notch at both ends to accomodate vertical cell reinforcing and grout W 45 > CU 0 LI Q ~ LO •!` N y T CU o Z Q Lu 130 0 LL LLI p U LL z >; woC 0 D O .� U W � � J J N o N date revision drawn 6.1. checked s.1. date 11/7/2020 scale as noted job number 20011 sheet A-1 i cc 8'-3- 1 T-8" 6'-3" 5'-10" T-10" T-9' (4) Risers at 7" (3) Treadql at 11" 10" 1" Nosing 1. YP- Cast In Place cone. Steps with 3000# mix F.F.E. 0.00' Riser Fight not to exceed 7 3/4"" 38'-4" T r � 19'-0" 16" T-0" 16" #5 Rebar 12"o.. T-8" 6,-2„ #5 Rebar TYP. —28," C S Cone. D OSteps F-1 ❑ -- - d F-1 04 I - I --❑❑ I 4'-2 2-13-5"'-5"17' 17" I F 8'-3" '' 14'-2" T-11" 8'-5co I I a I I c I + c Ft1 _ l ❑ �cc o ---- ❑ ---- F-1— ------ co — I o N I v R FL1 m — 4"' I -4„ .. p F-4 [7 �O �0 O F-4 OD �� F-4 01�--F-1-- EI �— I 4" 2500# 15 cone. pad I I F-s —� IN I I r F-2 _ N F_2 i — I 0 I 11'-2" ' I Ft1 14" I Slope for o Ft5 Garage Dr.60 TI (] 0400, 2'-1 3'-11" 18' L2'-0" \ 1'-11" I F-5 \ TYP. Typ' I o ❑ I i I O 12 M F cv (4) Risers at 7" ❑ I (3) Treads at 11 � ❑ Cone. I . 5 1 +n Steps 4- 2500# FIBERMIX CONC. I v ON CLEAN, OMPA TEDER o + ' I TERMITE TREATED FILL. � _ '`. _4„ 8" I 13'-9'" 5'-1" 3'-0' +" J ( � ASSUMED F.F.E. 0.00' i' Q F-1 -28"' I b F-3 slope 2 F 5 c� �i i Slope for I I ❑ Garage Dr. ' / Fh II 100 I I I I I I aa+ 14" I I I M — — — — — — — — p 'v IET - ,,.' �� I F-4 OD 3613"" 3'-0" 14" N — ❑ F-2 ------ -- — ---- — F-2 ❑. ❑• ❑' o 24"x 24~x 1i8" Pad 5 rebar with (1) #5 rebar 6'"o.c.. each way — F 4 _ _4" F 24"x 24"x 18" 4 I Pad FooLng with —+-II (1) #5 rebar 8" h each wayC. Ft1 v El ❑• goo o F-1' ---- `a �— a N O — -4 N F FE 0 ❑ -- I ❑ N ❑ F-4 ❑ ❑ N T-11" T-10- Foundation & Footing Plan scale: 1 /4- = V-0- J T-10- 114"" 14' 16'-8" Cone. Steps (4) Risers at 7- (3) Treads at I I 10 6'-0- T-8" 41'-0- " T-10"" 14- 14' 8'-4" 16'-8- T-4" one. tep Detail Garage F-1 F-2 18" x 1$" mono. footing with (2) #5 rebar Cont. and curb 8 SEE TYPICAL WALL 4" to 6" SECTION FOR DETAILS 4/, 16", 18" STEMWALL & FOOTING CURB FOOTING AT GARAGE F-3 F-4 Recess 4" at Shower 18" x 18" mono. footing 8" with (2) #5 rebar cont. 4" 4' 4„ 8" 16"" „ 4 A F8- 18" _-_- - 18" TYP. SHOWER RECESS STEP FOOTING F.F.E. 0.00, (2) #5 Top & (2) Garage #5 Bottom with (1) '28 #3 Vert. 16'o.c. Typ. ' F-5 osing Entry FFE sb°` � Ooo' Riser Hght. not to exceed 7.3/4" Cast In Place cone. = E Steps with 2500# mix /rand #5 rebar 12-o.c. / each way STEM WALL, SEE TYPICAL WALL SECTION --1�_ —28" 4- 2500# FIBERMIX CONC. OVER .006 VAPOR BARRIER ON CLEAN, COMPACTED, TERMITE TREATED FILL Conc. Step Detail Entry & Porch FORMWORK & SHORING GENERAL FOUNDATION NOTES No structural concrete shall be stripped until it has reached at least 80% of Concrete shall be a minimum of 4"' thick over clean, compacted, the 28 day design strength, termite treated fill and 6 mil polyethylene vapor barrier. Design, Erection, & Removal of all formwork, shores, & reshores shall meet If concrete slab contains 6"' x 6" 10/10 WWM provide I- coverage meet the ACI Standards 347 and 301 Concrete shall have at minimum compressive strength of not less Contractor to verify all building setbacks prior to the start of construction. than 3,000 p.s.i. A formboard survey shall be submitted to the building department for approval prior to pouring concrete. All 90% hooks are to be extended 10"" minimum beyond the turn. Field bends are to be done cold and the diameter of the bend, measured on the inside of the bar, is not to be less than six SOIL STATEMENT: bar diameters. Foundation has been designed for a soil bearing capacity of 2000 p.s.i. Minimum coverage for rebar shall be 3" in footings and 1 1/2'" in Fill shall be laid in layers of 12. Each layer to be compacted to 95% bond beams. Hooks may be rotated horizonitally if required to compaction. achieve minimum coverages. If the contractor encounters, while digging the foundation, any Rebar overlap shall be 48 bar diameters. 30" for #5 rebar discrepancy to suggest the soil may be inadecuate, he must immediately report it to the owner and the Architect or 'Engineer The foundation design assumes that the soil has a minimum so as to order a soil boring test load carrying capacity of 2000 p.s.f. p Dowel Rod Repair Note '.. In. the event the soil bearing capacity falls below 2000p.s.f. This foundation plan may besuperceded by Foundation Design Engineer. In the event vertical steel has been omitted from the down pour locations, drill 5" into concrete (no closer than 3 3/4"" Satisfactory compaction test of fill does not verify lower soils are adequate. from edges and 5' from ends of cap, walls) Remove dust per manufacturers instructions and use Two part epoxy to anchor the #5 rebar in place. Use either Hilti C-100"" or All specifications and dimensions to be verified by contractor. Simpson Epoxy —Tie. All exterior slabs shall slope a minimum 1/8" per foot for drainage V H Q N N 0 co W '!C V z M LL L0 WJ co le •(� W L N u) a co -J li C4 Q 0 CU Z W > > 'O 0 J W \�J '4-) VJ r" W ' Q W \� ~ / Lc. i N = O y T LJ� p cc r Z co Q UJ N ��cu/ Op CM L.L T ^ur h r ' �v 4 10, i14; { µ/x f %xTi1' gS° b � �pp-yr Y` 1 pµ m O LL M W i P LL Z W Q 0 .. C.) W 0 � � J o J � U drawn 3.1. checked e.t date 11/7/2020 scale as noted Job number 20011 sheet A-2 2" v.t.r. 2" v.t.r. 1 1/2 V I I 12 Q I 1 1/2' ��� I ❑5 6"Trim at Head N 04 LAV 4-Trim 12 ..and Sill. Q X co 5 4 Trimm at Jambs ��LW d. `./ z M I I I _ W.C. I T.O.B. (7 -J 2" WASHER 101-0" C (� N `D SINK � W O Window Head In 3 —1 N 8'-0" _ ❑ Cement Plank 0 J l�L N 2"v.t.r. Siding front only _ r r Plumbing contractor to provide a water hammer & shut off valve at j `� 1 1/2"" �' 4""Comer Trim ~ d each fixture 2„ I '\ IEll Z 2" v.t.r. 2- Auto 3„ �� I 2"" v.t.r. LJ LLI:�W `k Insulate all hot waier lines Vent I `�� LLJ U p f I I I I J .. I I I F.F.E. O LAv 3„ i I 0.00' Ill M SINK Entry F.F.E. ' LAvfLAV 3„ -28- J LAY 2" 3" ro'nt Elevation stuoao 0 $" .sale: t/ over CBS 4-Stucco Band 8" Stucco Base 2„ 2"" 3"' & Cap Trim Three Coat Stucco over TUB 3", TUB 2„ Paper backed wire lath on 3" 2"" 2"" one layer of House Wrap on W.G. 3-SHWR. 5/8""cdx plywood fastened to — 2" trusses per Nailing Schedule Q� i Plumbing Riser - — C.O. 3 " CU W Q 4„ g nr Diagram LO N .. = o ca 0 to septic — Oz N system — LLI Q 7n r v All sanitary lines, 2- or less shall have a slope of 1/4- per PLUMBING NOTES: foot minimum. Plumber to consult with contractor and equipment ordered All sanitary lines', above 2" shall have a slope of 1 /8" per for rough in dimensions. foot minimum. Verify all dimensions with the floor plan. The floor plan Provide Anti -Scalding Valve in all showers. dimensions dictates all other dimensions on other sheets. Lowest living area floor, elevation (refered as 0.00') to be Do not scale drawings, if any conflicts arise, contact the set by a professional land surveyor to the required building Architect or Engineer for clarification prior to construction. department elevation, but not less than 18" above the crown of the road. cu 00 Top of Window ❑ ❑ r+1 to Soffit, Typical ❑ ❑ FL-17 Rear Elevation scale: 1/4" = V-0" 12 2 ' 3 I 2 13 ---------- -- �— El El 2 2 1 3 3 (' 2 2 3 3 II 1 — 2 � 2 Right Elevation 2 2 f �— ---- --� / 1 2 scale: 3/16" = 1'-0"" / 2 / a 2 2 2 \ J -----_ 2 I / 2 2 / \ 3 3 2 2 \ L/I — — // 2 \\ 2 \\ 3 3 2, V/ / 1 \ \\, 2 ® ® ® ® ® ® ® ® 000 2 / \ Roof Wind Zones / \ ❑®® uuuuuu®® L— — - — — —� ®®® ®®®®®®®® 3 3 2 3 3 2 3 3 ®®® ®®❑®®®®® ' 4. Left Elevation scale: 3/16- = V-0„ I I Wind Zones - Walls w O W 0 LL z W O a., 0 .. uJCUa� C O I— U date revision drawn e.l. checked s.1. date 11/7/2020 scale as noted job number 20011 sheet A-3 Missed Tie Down Strap Note In the event the Tie Dbwn Strap has been omitted from the Layout location, install! one HTSM20 strap at the proper location. Fasten with (4) 1 4- x1!2 1/4- Hex Head Titan screw to C.B.S. and 00) 10d to truss. 1 MAXIMUM UPLIFT 1175 lbs. C C 1 C J 1 C C Connector Ndtes: Lateral forces perpendicular and parallel to wall has been Do not substitute connectors considered (less than 300 p.l.f.) Contractor to approve temporary bracing to prevent toppling Do not sheath trusses before all straps are in place of trusses, see HIB-9. Attach valley trusses and piggy back trusses, if present, Other specs, if different from above, have priority. to main trusses per truss manufacturer drawing. A.T.R. = All Treaded Rod Truss to truss connection by truss company, installed Drill and Epoxy Set all A.T.R. per manufacturers spec's. Use either-Hilti- 0-100 or Simpson Epoxy Tie Epoxy Connector Schedule Truss Bearing Truss Connector Gnty. Connector Fasteners Point Uplift ID Uplift 19 1849 HHETA20 1 2235 00) 1Od x 1 1/2" A1G 1 Ply 11 1713 HETA20 1 1810 (9) 10d x 1 1/2" (1) 5/8'ATR drilled & epoxy A21GE 26 2539 MGT 1 3965 into bond beam with 12""min. 2 Ply embed. and (22) 10d to truss F (1) 5/8"ATR drilled & epoxy 19 4022 into bond beam with 12-min. MGT embed. and (22) 10d to truss MTSM16 1 Each 4825 (7) 10d to truss and (4) B2G 17 4072 1/4-x 2 1/4""Titen to CBS 2 Ply 1 3787 (1) 5/8'ATR drilled & epoxy MGT 1 3965 into bond beam with 12"min. 11 3098 embed. and (22) 1 Od to truss All other trusses ALL <1810 HETA20 1 1810# (9) 10d x 1 1/2"" to CBS Supporting (4) 10d Valley Framing <250# VTCR 1 370# Valley (3) 10d x 1 1/2" Trusses Truss Truss Bearing Point Locations are numbered per the Truss Profile Sheets Provided' by the Truss Manufacturer. 2 x 4 diagonal "X" bracing at'8'-0'o.c. Galv, drip edge starting from ridge with (3) 12d each min. 4" lap end 2 x 4 blocking at 4'-0'o.c. starting from ridge between both top and bottom cords for two truss spaces from —< gable end (2) 1 trusses 24"" see layout See truss shop drawings Continuous 2 x 4 Lateral bracing at1/3 points of span. Nail with (2) 16d each truss btm. cord. Continuous 2 x'4 bracing fastened to beam with 5/8"" x 6" wedge bolts with 1/8- x 2- washer 24'o.c. Gable End Bracing Detail 2 x 4 bottom cord bracing Bottom Cord Lateral Bracing 1 x 3 p.t. over 2 x 6 Paint Grade Fascia Gable end truss by truss mfgr. 5/8" cAx. plywood `with 8d nails 4"o.c. Cover with House Wrap 2x "1"" web stiffener as required by the truss mfgr. "Simpson" HETA16 truss to bond beam with (14) 10d x 1 1/2- located at each truss vertical Concrete Bond `Beam Attic Vents Calculation GARAGE, PORCH, and ENTRY AREAS Attic Area: 1305 s.f. /'150 = 8.7 s.f. required. soffit area = 152.7'IS. x 1.5 = 229 s.f. end Venting Provided: ,CESS 8 x 16 soffit vent: 85 sq. in. each vent 15'Vents along overhang = 1,275 sq. in. A.F.F. 1,2775 sq. in. / 144 = 8.9 s.f. Total Ventilation Provided: 8.9 sq. ft.' Q 04 - p ao L W 114, v Z M LL to .� W to N d' 00 -J (1 N . a v 0.... V/ M Z C) ' a V (� W � O N o Q� W _W 0 W Q ~ •C LO N 'fir/ V r CD 00 Vi z _ LLJ r- Q w CIO 00 W M 0 LL LU � •L U U- Z W O _ p U) V W C J O J N H U date revision drawn ed. checked s.l. date 11/7/2020 scale as noted job number 20041 sheet A-4 STRUCTURAL NOTES: T' GENERAL R04FING NOTES Ceramic Ile Shall be installed in accordance with ANSI A108.1 A108.4 A108.5 All reinforcing steel shall be high strength billet steel and shall conform'to ASTM A-615 grade 60 specifications. Lap continuousRoofing to be composed of and attached to pre manufactured A108.6, A108:11, A118.1, A118.3, A136.1, & A137.1. Fiber mat reinforced wood trusses as follows: reinforcing 48 bar diameters or 30' in beams and in slabs. tap backer shall be used behind walla lied ceramic tiles in the tub bottom steel over supports and to steel at mids an. Hook PP Pp P P Felt underlayment (min. ASTM 0 226 Type.[0 with 4"' min: side and and shower areas and conform to ASTM C1325. Per Durock, discontinuous ends of all top bars. Reinforcing steel shallhave end laps, fasten with coorosion resistant annular ring shank! nails cement board exceeds ASTM C1325. a minimum of 1" concrete cover, or as follows: at 6" o.c. in laps and In staggered rows spaced 12' o.c. in field. If roof pitch is < 4/12 install (2) layers 15# felt. BOTTOM TOP SIDES If roof pitch is 4/12 or greater, install (1) layer 30# felt. Gypsum Mote Beams: 1 1 /2" 1 1 2" 1 2" 5/8" c.d.x. sheathing or equal installed with staggered joints & GI clips, / 1 / nailed to trusses with 8d corrosion resistant annular ring shank nails Gypsum board shall conform to ASTM C22,'C475, C514, C1002, C1047 Slab on Grade: 1 1/2" 1" _ yP spaced max. 6 o.c. throughout, except max. 4 o.c. at gable ,ends. 01177, 01178, C1278, C1396, or C1658 and installed per FBC residential Structural Poured: 3/4"' 3/4" Poured Walls: _ 3/4'" All roof trusses are to be pre -manufactured assemblies provided by code. Per USG, Wallboard conforms to 01396. Slabs exposed a licensed wood truss fabricator with separate drawings and data to the weather 3/4" 1 "' prepared for actual project conditions by a Florida registered Gypsum Board & Gypsum Panel Products professional engineer certified for truss design. Any deviation from Reinforcing steel shall be detailed and fabricated in accordance the proposed plans as shown regarding placement or bearin, shall with the "'Manual of Standard Practice of Detailing Reinforcingbe brought to the attention of the truss engineer prior to fa brication Gypsum board and gypsum panel products shall be applied g of the trusses. The truss manufacturer's certified layout shll govern at right angles or parallel to framing members. All edges and Concrete Structures" and the current ACI Building Code 318" after fabrication. ends of gypsum board and gypsum panel products shall All structural steel shall conform to current ASTM Specification A-36The handling, erection, and fixing of wood trusses shall be in occur on framing members, except those edges and ends that accordance with the specifications contained on the certifi;d mfgi's. are perpendicular to the framing members. Interior gypsum All wood' in contact with masonry shall be pressure treated or apl roved drawings and data. board shall not be installed where it is directly exposed to separating material weather or to water. All engineered headers and truss hangers to be provided by, the truss manufacturer. All dimensions shall be verified in field by the contractor. If there!, are Wall and ceiling gypsum board shall be fastened with screws any discrepancies the Architect or Engineer shall be notified before Splitting or cracking of structural components due to installation of spaced at 12"o,c. Screws for attaching gypsum board and gypsum proceeding. hardware is not permitted. panel products to Wood framing shall be Type W Or Type S in Unless otherwise noted, the installation of specified hardwa%e shah accordance with ASTM C1002 andshall penetrate thewood not No slump over 5-shall be permitted for any structural concrete ithout conform to the truss manufacturers installation instructions and ' less than 5/8" inch 0 5.9mm) Gypsum board and Gypsum panel the Architect or Engineer approval. standard practice. products shall be attached to cold formed steel framing less than 0.033" (1mm) thick shall be Type S in accordance with All Design and Construction shall be inaccordance with the current ASTM C1002 or bugle head style in accordance with ASTM C1513 American Concrete Institute(ACI). and the American Institute of Steel and shall penetrate the steel not less than 3/8" to 0.112 Construction (AISC), The Florida Building Code and all applicable 0 mm to 3mm) thick shall be in accordance with ASTM 0954 or local codes. bugle head style in accordance with ASTM 1513. Screws for attaching gypsum board or gypsum panel products to structural Structural Concrete shall attain a minimum ultimate compressive strength insulated pagles shall penetrate the wood structural panle facing (Fe') in 28 days as follows: not less than 7/16"o.c. 01.1 mm). 8" x 16- C.M.U. WITH CELLS FILLED Column Footing and Wall Footing: 3000 p.s.i. WITH GROUT & (1) #5 VERT. Gypsum board used as the base orbacker for adhesive application Column and walls from foundation to roof: see column schedule. .' . DOWEL of ceramic tile or other required nonabsorbent finish material shall All other concrete: 3000 ps.i. a conform to ASTM C1396, 01178, C1278. Use of water resistant gypsum backing board shall be permitted on ceilings. Water Footing sizes and reinforcing are based on allowable soil bearing resistant capacity of 2000 ps.i. All footings shall bear in virgin soil. If this x gypsum board shall not be installed over a Class 1 or is not the case, the Architect or Engineer shall be notified Defer w Class 2 vapor retarder in a shower or tub compartment. Cut or g P.T. 2 x 6 AT (3) SIDES OF &-/] exposed edges, including those at wall intersections, shall be proceeding with the work. OPENING, FASTEN TO BLOCK sealed as recommended by the manufactuer. Water resistant AS NOTED. gypsum backing board shall not be used where there will be Timber (Heavy Timber Construction) DOOR SIDES ' direct exposure to water, or areas subject to continuous high (a) Truss manufacturer shall submit a signed and sealed shop humidit drawings by a registered Engineer. 1/2"' x 6"'REDHEADS iWITH MIN. y' (b) Wood rafters to have a Stress Grade of Fb=1200 ps.i. ii 2" x t/8"WASHER 12" FROM ENDS (c) Roof members should be secured to the beams or other o AND 16"o.c. MAX. structural components with hurricane anchors for wind uplift. 0 Cold Formed Steel Note S DOOR HEAD All wood members shall have a minimum fiber stress in bending 1/4" x 2 3/4" TAPCONS STAGGERED Cold formed steel framing supporting gypsum board and gypsum of 1200 p,.s.i. with 1/360 max. deflection. 24-o.c. panel products shall be not less than 1 1/4" (32mm) wide in the least dimension. Non Load bearing cold formed steel framing All bolted; connections shall be 1/2" Cadmium plated or better. shall comply with AISI S220 and ASTM C645, Section 10. Load bearing cold formed steel framing shall comply with AIS1 S200 Lag bolts to be used only in shear connections with minimum Garage Door Buck Detail ASTM C955, Section 8. 4- threaded penetration past steel plate. Lag bolted conditions shall be drill tapped no larger than the Wood Framing Note internal thread diameter and shall not be hammer driven. Under Girder Trusses provide equal number of studs as girder Wood framing supporting gypsum board and gypsum panel plys at frame bearing locations products shall be not less than 2- (51 mm) nominal thickness P I in th least dimension except that wood furringstrips not less than 1" b to be used over m) nominal di ension sal a GENERAL REQUIREMENTS Bottom sCord P g g P �° not more than 24"o.c. (610mm) All work to be as per the current edition of the FloridaBuildingCode and meet or exceed all applicable local requirements. General contractor is responsible for all labor, materials, utilities, testing, Wire Lath Attachment waste removal, storage, securing of sited accomodation, transp rt/freight, and all other cost related to the completion of this project., un ess explicitly Over wood framing the paper identified here. 2 x 4 top plate backed wire lath Shall be Installed Owner is responsible for all municipal related charges such as impact over one layer of approved plastic fees, and water connection, except building permit fees, which are to be house wrap. Lath shall be attached included in the construction bid. 1/2„ gyp dw horizontal framing members with 1.5 General contractor to check all drawings for errors and ommis ionsiand roofing nails and t0 vertical wood bring them to the attention of the architect prior to starting any work, or framing members with 6d Common ordering any materials of the respective division of work. If such errors 2 x 4 studs 24"o.c. nails or 1 roofing nails driven t0 and ommissions are not reported in writingto the architect, an resulting No. 3 Stud Grade penetration of not less then 3/4"" damages or costs shall be born entirely by the general contra^ or, of an inch, or 1 wire staples Architect is not responsible for the contractors method or me ns of driven flush with the plaster base. construction. 2 x 4 p.t. sill plate Staples shall have Crowns not less General contractor is to keep the site in a clean and safe state through than 3/4" and shall engage not less out the course of construction. On building turnover, general c ntraptor to than three strands of lath and clean all surfaces so as to be free of dust, grease, stains, scuffs, etc: wood base penetrate the wood framing members not less than 3/41�. The fasteners must Unless otherwise noted, the installation ;of specified hardware hall conform to the manufacturers instructions and standard practice. Cased Hard Coil penetrate the wood framing members Nails 12"o.c. max. not less than 3/4 Fasteners shall be All plans and drawings are not considered complete until they have (been %" O.C. max, reviewed and approved by the St. Lucie County Building Department F.F:E. and the building permit has been issued; 0.00'- EXTERIOR CEILING & SOFFIT NOTE ^' 7/8 Stucco finish over 3/8" high ribbed gale. wire lath fastened to SHEATHING NAILING DOTES Concrete framing members with No. 11 guage nails with l 3/4- embed. with 3/8- Foundation dia. head 6"o.c. max. edges to be tied and nailed at 9"o.c. Install one layer of 15# felt to framing prior to installing ribbed lath Nailing Pattern Nailing Schedule Zone 1: 8d at 6"o.c. field & 4""o.c. edges ROOF & FLOOR DIAGRAM Interior Wall Section INTERIOR WALL FRAMING NOTE Zone 2: 8d at 4"o.c. edges & field Use sheathing with#8 gun nails at 6"o.c. Zone 3: 8d at 4-o.c. edges & field at supported panel edges and!#8 gun Interior non bearing walls to be 2 x 4 studs 24' o.c. nails at 6"o.c. at intermediatesupports. Spruce, Pine, Fir (SPF) #3 Grade lumber or better Pneumatic Nails or metal studs (25 Ga.) Crimper may be used in lieu of screws. Pneumatic or mechanicaly driven nails will ROOF SHEATHING TO GABLE END FRAME be accepted under the following conditions: Use #8 gun nails at 4'o c. BUCK ATTACHMENT NOTES Min. nails size 8d or larger ring shank with comer bars at be.T Min. shank diameter:.113 EXTERIOR SHEATHING (outside only) (2) comer AT DOORS USE P.T. PINE OR SPRUCE AND ATTACH Min. Length: 2" bars at footing (minll) Use #8 gun naps at 4 o c: at panel edges TO BLOCK WITH 1/4" D[A. TAPCONS INTO C.B.S. Min. Head 'Diameter. .280 Full Round and #8 gun nails at 4 0.. at panel top and e SET AT 6" FROM CORNERS AND AT 12-o.c. MAX. Min. Ring Qiameter .012 over shank dia bottom and 6"o.c. in field ir Min, 16 to,120 Rings Per Inch vert. dowel lapped with AT WINDOWS USE P.T. PINE OR SPRUCE AND ATTACH wall reinforcing, all BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS Note laps 30' (min.) in grout OR "T"" NAILS" 4" FROM ENDS AND 12 o.c. filled cell Gun nails shall be permitted as an USE WOOD SHIMS MINIMUM DURING DOOR INSTALLATION acceptable fastener from any manufacturer Wood screws meeting the same size requirement THRESHOLD NOTE may be used in lieu of nails without comment 30' Lap min. At egress door (see floor plan) the max. hgth. Corner Reinforcing Detail of the threshold shall be 1/2" g i 3/8" continuous bead of 5V Roof Panels caulk (back bedding) behind buck to prevent liquid passage over 30# Felt on set flange in continuous 19/32" o.d.x, plywood fastened bead of caulk across the as per nailing schedule entire face of buck CBS Pre Engineered Wood Roof Trusses 24"o.c. u Min. 1 1/4" embedment Shop Drawings by w cg n a at windows and min. 1 1/2"` at Others °: embedment c 2 ti d a ° a sl. gi, doors g 1See Connector ;oaf cc B Q Schedule a0 �d a 1/2" drywall 12 Galy. Drip Edge R2¢ Spray Q 5 over 1 x 3 p.t. Foam Insu . 10,-0„ot T.O.B. stucco finish perimeter caulk 1 /2"" d.W. 1/4-.max. struct shim Attach p.t bucks - 1 x 4 p.t. with 8d coil nails at 12'o.c.Firestopas 2 X 6 Cedar Per Fascia Board Typ. Alum. window cturers jamb or sliding glass product approvals doorjamb Stucco Soffit Over NOTE: Method of attachment and Gunable sealants shall comply with ASTM C 920 Class Two Course Perimeter High Ribbed Wire Lath waterproofing procedures are the 25 grade- or same at poured concrete sill. greater for properjoint expansion Beale With (1) #5 Rebar 1 `6" and contraction in each course, Filled Install one layer of 15# Coat Bucks with Protecto LWM200 Waterproofing With Grout felt to framing prior to after they have been installed and Chaulked installing wire lath Window & Door Flashing Detail at CBS Wall 1 x 2 p.t furring Includes Buck Attachment Method strips 2411o.c with R4.1 Foil insulation 8 x 16 x 8 Alum. window corrosive resistant :. CMU Typ• frame Tapcon concrete d 3/8' continuous bead of srews installed as caulk (back bedding) behind specified in window shim to prevent liquid passage manufacturers product Light Textured approval #5 Vert. rebar in Stucco Finish 1/4" struct. shi window sal grout filled cell set flange in continuous See Floor Plan bead of caulk across the entire face of buck for Locations perimeter caulk stucco finish d' ° #5 Vert. Rebar with precast Protecto LWM200 - - cone. sill 10"" Hook and 30" Coating on Outside face Lap. Tie to Vert. and Janbs of Openings all Sides min. 8 Gunable sealants shall. comply with Reber In Cells ASTM C 020 Class 25 grade or greater for proper joint expansion and contraction (1) #5 M Reber Typical Precast Cone. Sill Detail Coat Bucks with Protecto LWM200 Waterproofing after they have been installed and Chaulked F.F.E. N w v � Galy. Cap °D +o, s i 4" 2500# Fibermix Conn. 100 ao on .006 Vapor Bearier on cIV 06 Clean, Compacted, Termite i % 2" dia. Galy Treated Fill c Pipe LU Grade Set ballard 12" 00 from appliance koN Galy. Collar (2) #5 Rebar=lr-4- Typical(4)1/4""x21/4"' Cone. Typical Wall Section Foundation Tapcons Bollard Detail all comer bars to be the same size, number, and spacing as horizontial bars in footing, beams, and walls PRODUCT APPROVAL Approval Product Model Number Manufacturer Glass Attachment Method Building Rated Product Rated Number Type Design Pressures Design Pressures Head: 12" max. from comers & 30"o.c. max. Jambs FL 239.7 S.H. Windows SH-5500 Singlehung PGT Industries Impact 12' max. from corners & 17 7" max. 5 each side of meeting rail. Use 1/4" Tapcon with 1 1/4' embedment +33.5 -44.8 +/- 50.0 into concrete Head and Sill: 6-max. from corners & 15"o.c. max. at FL: 243.5 Picture Windows PW-5520 Singlehung PGT Industries Impact Jambs. Use 1/4" Tapcon with 1 1/4" embedment +33.5 -44.8 +/-50.0 into concrete '.. Glazed B" from corners and 3"& 7-each sideof center at head & FILM 17184.2 Swing Doors Fiberglass Plastpro Impact sill and 6-from corners & 14 1/4-max. o.c. at jambs. +33.5 -36.3 +/- 50.0 Door 1/4" tapcon screws with 1 1/4" embed, into cone. FL#: 17184.5. Swing Doors Fiberglass Plastp r o Impact 6" from comers & 14"o.c. at jambs, head, sill. 1/4" tapcon screws with l 1/4" embed. into conc. +33.5 -36.3 + 65.0 -70.0 (Inswing) Door FL#: 5678.28 Overhead Door Grand Harbour Clo a Clopay Impact Flag Bracket Angie (3) total 5/16" x 1 5/8" lag screws. (7) total +27.9 -3t2 +37.0 -41.0 Series Bracket T-0" height (1) 5/18" x 1 5/8" lag screws per bracket, Approval Product Model Number Manufacturer Attachment Method' Building Rated Product Rated Number Design Pressures Design Pressures FL: 17443.1 Roofing 5V CrimpJA Taylor Roofing g #9-15.x 1"coorosion resistant screw with sealing. washer at each rib 12"o.c. in field and 6"o.c. along perimeter. -45.0 -69.25 FL: 9777.7 (optional)Undedayment. Roofing Weatherlock Specialty Owens Coming g Direct attachment to plywood deck -45.0 -142.5 FL: 12098.1 Siding Lap Siding Nichiha Aerosmith Fastening Systems, SurePin 2'9ong, .30 Head Dia., .145 Shank dia. Direct to CBS, Face Nail 16"o.c. -45.0 -78.3 V Q LU � ',. e�_ V Z M U LL 'LO bQ N al Q fL 00 Q .. U O ICU Z it U UJ > ID o N Q� LU C) m !4^-J v! W U Q CU w F- .� / LO N 00.0 C.) Cc Cc LU Q V /cu iL M Cn LL LLI U LL Z >, Lu 0-" c .. 0' LlJ N J 0J O U date revision i drawn S.I. checked s.l. date 11/7/2020 scale as noted job number 20011 sheet A-5 Smoke detectors wired to 120V Bathroom lights Non Switchable, Non GFt Electrical contractor to verify all equipment loads prior to' start of construction. Electrical contractor to recalculate electrical schedule if loads are to be modified Electrical Notes 1. All loads to be checked by a Florida Licensed Electrician 2. All work to meet the National Electrical Code 3. Calculations and panels below are for sizing conduit and overall building load requirements only 4. All conductors to be copper; all insulation to be THHN. Conduit as follows: PVC below ground, Rigid from underground to service box for exterior lights on building, AC, MC, or EMT conduit elsewhere. 5. Ensure min. 36" clear between equipment and disconnects; Typical Electrical Load Calculations 1941 Living S.F. at 3 VA 5823 watts One 20 Amp Appliance Ckts. 1500 watts Two Laundry Cir. @ 1500 watts 3000 watts One Dishwasher & One Disposal @ 1500 watts each 3000 watts One Microwave @ 2000 watts 2000 watts One Wall Oven 6000 watts One Dryer @ 5 kw 5000 watts One Ref. @ 1500 watts 1600 watts Three Baths @ 1500 watts each 4500 watts One Exhaust Hood 1000 watts Water Heater 8500 watts Septic Hook Up 1200 watts Well Pump 1400 watts Total 44,423 watts First 10 KVA at 100% 10,000 watts Remainder at 40% 13,769 watts Total 23,769 watts One AC Heat at 100% 10,000 watts Total 33,769 watts 33,769 W / 240 V = 140.7 Amps Use 200A Service (3) #2/0 (THW) copper and (1) #4 ground (THW) copper in 2 galy. conduit (3) #2/0 (THW) copper and (1) #4 ground (THW) all F.P.L. service copper in 2 galy. conduit (if overhead service) Panel: 200 B. 200 Amp Circuit Circui 1,6, 3W 40 Cit Panel M O 120/240 Volt a.c. disc. (3) #2/0 (THW) copper and (1) #4 ground (THW) copper in 2 galy. conduit 5/8" dia. x 10'-0- F.P.L. service (if underground long ground rod 3/4"" copper '.service) water pi 8'-0" tie ground wire to footing rebars Electrical Riser Electrical Riser Diagram i Well Pump Disc. Safe Meter EP gf, FM 01ac. wh gr' o Xah. o Golf Cart eC I Cing. Mount for G.D.O. I I �1 p:c. in I attic I I L---I � I '. Cing. Mount ' for G.D.O. Dining Kitchen r 510 I I L-------- I grl. Garage Electrical Plan scale: 1/4" = 1'-0"" ELECTRICAL LEDGEND O RECESSED LIGHT WITH LENS Cd EXTERIOR & WET LOCATIONS I SURFACE MOUNTED LIGHT FIXTURE 'r TTTe SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE I, . UNDER CABINET FLUORESCENT FIXTURE e RECESSED:. INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN CEILING FAN I iO EXHAUST FAN OUTLET pp0000qq I_J DOOR CHIMES THERMOSTAT COMBO SMOKE & CARBON S MONOXIDE DETECTOR DUPLEX OUTLET- SWITCHED TELEVISION DUPLEX OUTLET L. 220 V OUTLET TELEPHONE SWITCH M• LUSH BUTTON -( THREE WAY SWITCH ..yr DIMMER SWITCH NOTE: ''RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46- A.F.F. ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING i OUTLETS THAT ARE NOT GFCI MUST BE AFCI. TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE'15 & 20 AMP BRANCH CIRCUITS COORDINATE THE TV AND PHONE LOCATIONS WITH CONTRACTOR Fan & Light Bedroom 2 Porch //x `�� F/F)r I `V1 w°QD Y� i n 3Wt, \ I IMasten Bdrm. � ---\ — — —-- J i � 1 i� \ IIr3w ' Living RoomvP I I I in 1 attic vp i I---. — I — — — — — — — ® w,. 6[ \\ 1 S S Septic SD Hook Up Fan & Light' wp INStudy gr \ I Entry - I U r.y I Q. 0 M w M oo r� �1 V Z CO) LL W00 i •� 0 0. J LL N a I Z(L Uw ; o 0 � _J U) Q� w '-I^-) vJ I' Qi ~ (D (a >~tn.�N •_0 �vc)Z00 N �a LLI C/)v r p I Q LL uJ p 0 LL Z w O o N LU N —J 0 F— C) date revision drawn checked S.I. date 11/7/2020 scale as noted job number 20011 sheet A-6