Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval (2)
4/9/2020 Florida Building Code Online hZ lid _ BCIS Home Log In I User Registration I Hot Topic Submit Surcharge Stats&Facts Publications I Contact Us I BCIS Site Map Links Search I Florida Product Approval Oa-si USER:Public User dt � §ZECEIVED Product Aeorowl Menu>Product or Apyliwtion Search>epoliration Llst>Application Detail • j „• FL# FL10674-R35 2020 Application Type Revision permitting Department Code Version 2017 St. Lyle County Application Status Approved J lie Copy Comments / Archived R WE ED FOR Product Manufacturer Owens Corning CODE COMPLIANCE Address/Phone/Email One Owens Corning Par a�0 L CIE COUNTY Toledo,OH 43659 NSA (740)404-7829 BOCC `� ,6 greg.keeler@owenscorning.com (—JAG//`/ !/t]C) Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer O Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M.Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies,LLC Quality Assurance Contract Expiration Date 01/01/2099 Validated By John W. Knezevich,PE 0 Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R15 COI 2019 01 COI NIEMINEN.p.Lf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr app_dfl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6ixEDL 5g 209MAD/C d—1/2-. 4/9/2020 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 08/15/2019 Date Validated 08/15/2019 Date Pending FBC Approval 08/21/2019 Date Approved 10/15/2019 Summary of Products FL# Model,Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles Shingles and Starters Limits of Use Installation Instructions Approved for use in HVHZ:No FL10674 R15 II 2019 08 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R15.pdf Impact Resistant:N/A Verified By: Robert 3.M.Nieminen PE-59166 Design Pressure,N/A Created by Independent Third Party:Yes Other: Refer to ER,Section 5. Evaluation Reports FL10674 R15 AE 2019 08 FINAL ER OC ASPHALT SHINGLES FL10674-R15.pdf Created by Independent Third Party:Yes Back Next Contact Us::2.601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer."oo yljaht 2007-2013 State of Florida.::Privagy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.27S(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: M• K] ® [Pol ;Credit Card https:Uwww.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQ8ucR6ixEDL76gG32Q9MA%3d%3d 2/2 NEMO I etc. Certificate of Authorization#32455 353 Christian Street,Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION .O. Owens Corning Evaluation Report 037940.02.12-1110 One Owens Corning Parkway FL10674-R15 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)404-7829 Revision 10: 08/15/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s),the Quality Assurance or the production facility location(s). NEW I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M.Nieminen P.E. %s:.�: or%`'= The facsimile seal appearing was authorized by Robert z '.'%.FS�� Nieminen,P.E.on 08/15/2019. This does not serve as an Florida Registration No.59166,Florida DCA ANE1983 electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOJetc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO l etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO I etc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018,NEMO ETC,LLC ONEMOletc. ROOFING SYSTEMS EVALUATION: SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 61'Edition(2017)Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. STANDARDS: Section =- Pro a 'Standard Year 1507.2.4,R905.2.3 Physical Properties ASTM D1970 2015 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Enti Examination Reference, Date " Owens Corning Declaration Equivalency Declaration 08/06/2019 PRI(TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various PRI(QUA9110) Quality Control Service Confirmation 04/05/2020 4. PRODUCT DESCRIPTION: 41 ACCESSORY STARTERS:,. 4.1.1 Starter Strip Shingle,Starter Strip Plus and SRS TopShield Starter are starter strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 Starter Shingle Roll is a mineral-surfaced,fiberglass-reinforced,self-adhering SBS modified bitumen starter strip, nominal 7.2-inch wide x 33-ft 4-inch long roll,for use with asphalt shingles. Meets ASTM D1970. 4.2 ASPHALT SHINGLES: 4.2.1 Classic°and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles.Meets ASTM D3462. 4.2.2 Berkshire*are fiberglass reinforced,4-tab asphalt roof shingles. Meets ASTM D3462. 4.2.3 Duration%TruDefinition°Duration Duration®Premium Cool,TruDefinition®Duration*Designer Color Collection, TruDefinition°Oakridge, Oakridge° and WeatherGuard° HP are fiberglass reinforced, laminated asphalt roof shingles. Meets ASTM D3462. 43 HIP Bi:RIDGE SHINGLES: 4.3.1 Berkshire'Hip&Ridge Shingles with Sealant,DuraRidge®Hip&Ridge Shingles with Sealant,ProEdge®Hip&Ridge Shingles and WeatherGuard°HP Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. Meets ASTM D3462. NEMO ETC,LLC Evaluation Report 037940.02.12-1110 Certificote of Authorization 832455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-RlS Owens Corning Asphalt Roof Shingles Revision 10:08/iS/2019 Page 2 of 10 -(14MEMO l etc. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither MEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 The Owens Corning asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating acceptable use in all wind zones Up to V.,d=150 mph(V„It=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3,and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.2 Starter Strip Shingle,Starter Strip Plus and SRS TopShield Starter noted in Section 4.1.1 and the Owens Corning hip &ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating acceptable use in all wind zones up to Vasd=150 mph(V„It=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 611320-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 ACCESSORY STARTERS:- 6.2.1- Installation of Starter Strip Shingle,Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions,using minimum five(5)nails per strip. Felt underlaymant Deck FeltimdMrymmt gecY sdadhered Sell-adhered man weatherLocka tmdedaymetd aoedge _ ftalge Nails located uaibratad Y-a'from save r�trem aava lmhll first Self-seafawadhesivs MtdFmeStener StdpF4n SJaea6aj adhesive startersuip positioned along save xph�mmm,d _,_ PastionM olona save shingle with s'removed Blotter strip shingle overhangs eaves and cakes lh=Y' stators 1Rwavedunas eavn mdroko vaa/a• Figure 1:Minimum Nailing,Starter Strip Figure 2:Minimum Nailing,Starter Strip Plus NENIO ETC,LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R35 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 3 of 10 ONEMOjetc. 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. Deck Underlayment Drip edge Drip edge Starter Shingle Roll adhered directly to underlayment and primed drip edge Self-sealing adhesive positioned along eaves Figure 3:Starter Shingle Roll 6.3 'ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: ➢ Berkshire°shingles require minimum five(5)nails per shingle. ➢ WeatherGuard®HP shingles require minimum six(6)nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Classic®&Supreme: Normal Mansard or Arse pare Normal Mansard or Area pare Wind Areas High Wind desvenes y Wind Areas High Wind deavanes y Area pare vientos normales Areas vientos fuertes Area pare vientos nornolea Areas vientos fuerres �• (A) �., r 1- z• (B r2' 11' �" (A) �' �' z• (B) z. �. 1zt . . . . . . . . . . . . W Exposure 5 5/8'Exposure Exposicfon Exposicidn Figure 4:Minimum Nailing,Classic&Supreme Figure 5:Minimum Nailing,Classic&Supreme (Standard Size) (Metric Size) NEMO ETC,LLC Evaluation Report 037940.02.12-1130 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVH2 EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 4 of 10 ONEMOjetc. 6.3.1.2 Berkshire®: Sealant swp: Sealant strip La tira de seWor. La tira de sellador •i-4 Q_ --s': i— '� • —+a.--.• •.--► •----.• B:Yx 9 Yf 9 Yt B Vr "? a 8 lb" 8 W 8 W, 8 W, } r Figure 6: 5-Nail Pattern,Berkshire Figure 7: 6-Nail Pattern,Berkshire Sealatrt.stirip La fba de sellador, R 8 Yf. SYt' 8 Yi'' 8'Ve V 2 Asphalt rooMgcement Cenienfo tle tesho de astaho Figure 8: Mansard or Steep Slope Pattern,Berkshire NEMO ETC,LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization#32455 CH EDITION(2017)FBC NON-HVH2 EVALUATION F1.10674-1115 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 5 of 10 NEMO I etc. 6.3.1.3 Duration®,TruDefinition®Duration,Duration®Premium Cool&TruDefinition"Duration'Designer Color Collection: 4-Nail Fastenin§Pattern SumNait®fastening area width Nail;Typical 1" 12" v.—cone S—NA • w. sago moo. • a.YB c� so�teaa., • �F ;6'118";6.5l8 esponrc Figure 9:Standard 4-Nail Pattern,Duration 6-Nail Fastening.Pattern' SureN;d10 fastening area width; Nail;Typical 1" 12" 12" 1" finenscmrsre�SwetlaH ,::• ....,,•.'�R2mg iwroy ziraKp - •-o+iens Car�q See(:ai'9'+ .• 61B".:rr518.' Figure 10: 6-Nail Pattern,Duration Fastening:for Slop'es:Greater Than`2T72 SureNail®fastening area width Nail;Typical 1" 1211 •*n CaNnp sm" - • •'E:i�Ms O.ewo�cvaap Y •avail Canuip SfriYa, • 6418" 5.518 emosue - �2" Four 1"Spots of Asphalt Roofing Cement Figure 11: Mansard or Steep Slope Pattern,Duration NEMO ETC,LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization N32455 0 EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-RSS Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 6 of 10 (NNEMOletc. 6.3.1.4 TruDefinition Oakridse®,Oakridse®: 4 Nail Paftem Esquema,con 4 0.avos t^ a° 55/8".'Exposure... Natls: 56/8"Exposure ;. ExposFc M de 6618 ping. Claws Exposieign de 55l8pu1g. Figure 12:Standard 4-Nail Pattern,Oakridge 6 Nail Pattern, Esquema con 6'clayos r rir liW Exposure Naffs ciavos 5 5/8"Exposure: Exposicaon,de 66/00419.. fxppsieip6 de 5S/8,pufg.; Figure 13:6-Nail Pattern,Oakridge Fasten1fil f fob Slopes;Greater Than 21:12: SureNalw fastening area width Nag,Typical 1" 12"' 12" 1"- '_VwuCuroCSmsai ...�.. /i345mJ�0 - ..._�Owe•Canep S.eNYN: .. &1WE-- �2. Four 1"Spctabf Asphalt Roogng'Cement Figure 14:Mansard or Steep-Slope Pattern,Oakridge NEMO ETC,LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization#32455 6'N EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 7 of 10 MEMO etc. 6.3.1.5 WeatherGuard®HP: ►I 1 12PIS 12�t� �U ivy mts 5 5ta'E�nsve E4ros, de 5 5.8 pulp, tipWcl&5i h 5 5J8 pu4g� Figure 15:6-Nail Pattern,WeatherGuard HP 6 Nail Pattem Esquema con 6 claws Nail 6118'from bottom of shingle la 5 5/8'Exposure parte inferior de la e 6 Fasteners Clave a 611 pping de Exposici6n�de 5 518 ping. 6 sujetidores pan teja 1w4 1 pi; 'F 2' —i►� IE— t2 I. • UP • • r • >ZN� i Four 1°Spots of Asphalt Roof Cemerit Cuatro puntos de cemmto de toaa de asfafto de f pulgada Figure 16:Mansard or Steep-Slope Pattern,WeatherGuard HP 6..4 �HiP&RIDGE SHINGces: � 6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. ➢ Berkshire Hip and Ridge Shingles with Sealant and DuraRidge® Hip & Ridge Shingles with Sealant require minimum two(2)nails per shingle. ➢ WeatherGuard' HP Hip and Ridge Shingles and ProEdge® Hip & Ridge Shingles require minimum four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. NEMO ETC,LLC Evaluation Report 037940.02.12-RiO Certificate of Authorization#32455 67H EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R15 Owens Coming Asphalt Roof Shingles Revision 10:08/15/2019 Page 8 of 10 NNEMOjetc. 6.4.1.1 Berkshire®Hip&Ridge with Sealant and DuraR)dge®Hip&Ridge Shingles with Sealant Fig. A PrevailingWindDirection Fig. B Top View �— Direccibn del viento predominante t° Vista superior Nail 2% clavo Nails a • Owens Wmfng.SveNal`_. �- Clavos I I I I I I I cl� ( i W 21 V P166nde d I c 109 V 11 I. I P 12" Figure 17:Isometric View,Berkshire and DuraRidge Figure 18:Plan View,Berkshire and DuraRidge 6.4.1.2 WeatherGuard®HP Hip&Ridge Shingles: Fig.A s.4 FIg.C Hip&Ritlge, Ingle Fastening'., E-Prevalling Nand TOVlew Dlreclbn p A` Nalls 4 4 j I `\\ A Nalls. Nails 44 I I. °— :Expo6sure "' 5 Exposure I ZNL:S: Figure 19:Isometric View,WeatherGuard HP Hip&Ridge Figure 20:Plan View,WeatherGuard HP Hip&Ridge NEMO ETC,LLC Evaluation Report 037940.02.12-R10 Certificate of Authorization#32455 CH EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R35 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 9 of 10 ONEMOjetc. 6.4.1.3 ProEdge®Hip&Ridge Shinales: Prevailing Standard Wind'Direction SeafaIM Stri Fastening p Pattern `-` 6•Exposure ! •� ~I I IMT • 12 Sealant Fasten 7'h• 7'r= 6•Exposure Cover Exposed 1 1 Fasteners with Roof Cement Figure 21:Isometric View,ProEdge Figure 22: Plan View,ProEdge 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. PLANTS:9. MANUFACTURING Contact the named QA entity for information on which plants produce products covered by Florida Rule 611320-3 QA requirements. QUALITY10. PRI Construction Materials Technologies,LLC—QUA9110; 813 621-5777;bwilson@pricmt.com - END OF EVALUATION REPORT- MEMO ETC,LLC Evaluation Report 037940.02.12-1130 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10:08/15/2019 Page 10 of 10