HomeMy WebLinkAboutCompaction TestPort St. Lucie Branch Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone:772-878-0072 r aA r d am a In -Place Density Report Client: & Associates, Inc. Permit # 1912-0370 Renar Development Corp. 3725 S. East Ocean Boulevard, Suite 101 Stuart, FL 34996 Report Date: 12/17/2020 Test Method: ASTM D6938 Project: 113-15-66-5434B Morningside Residential Lots Fort Pierce Fort Pierce, FL Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture % Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pc In Place Wet Density pc Probe Depth (in) Percent Compaction Min Comp. % Remark 390 12/8/20 20-310 Modified A 10.0 115.0 10.6 113.6 125.6 12 99 95 Pass 391 12/8/20 20-310 (Modified) A 10.0 115.0 12.1 112.4 126.0 12 98 95 Pass 392 12/8120 20-310 (Modified) A 10.0 115.0 9.4 115.7 126.E 1 12 101 95 Pass 393 12/8/20 20-310 (Modified) A 10.0 115.0 11.0 114.3 126.9 12 99 95 Pass 394 12/8/20 20-310 (Modified) A 10.0 115.0 8.6 115.2 125.1 12 100 95 Pass 395 12/8/20 20-310 (Modified) A 10.0 115.0 11.9 113.7 127.2 12 99 95 Pass 396 12/8/20 20-310 (Modified) A 10.0 115.0 12.2 112.1 125.8 12 97 95 Pass 397 12/8/20 20-310 (Modified) A 10.0 115.0 11.3 113.9 126.8 12 99 95 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 390 House Pad - Pad Fill: Lot 81. 9700 Starboard Drive. House Pad. NE Corner -1.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 391 House Pad - Pad Fill: Lot 81. 9700 Starboard Drive. House Pad. NW Corner -1.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 392 House Pad - Pad Fill: Lot 81. 9700 Starboard Drive. House Pad. SW Corner -1.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 393 House Pad - Pad Fill: Lot 81. 9700 Starboard Drive. House Pad. SE Corner -1.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 394 House Pad - Pad Fill: Lot 81. 9700 Starboard Drive. House Pad. N Footing -2.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 395 House Pad - Pad Fill: Lot 81. 9700 Starboard Drive. House Pad. E Footing -2.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 396 House Pad - Pad Fill: Lot 81. 9700 Starboard Drive. House Pad. S Footing -2.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 397 House Pad - Pad Fill: Lot 81. 9700 Starboard Drive. House Pad. W Footing -2.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie Remarks Comments Pass: Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as 1"Backscatter". Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL. OwArdamanln-Place Density Report Associates, Inc. Permit # 1912-0370 Port St. Lucie Branch Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone:772-878-0072 Report Date: 12111 /2020 Test Method: ASTM D6938 Client: Renar Development Corp. 3725 S. East Ocean Boulevard, Suite 101 Stuart, FL 34996 Project: 113-15-66-5434B Morningside Residential Lots Fort Pierce Fort Pierce, FL ,`y�ti1441 I I I111���� ♦t1, �•�VtCEIy��,,��. r 4'�• No. 63911 ,-= *r srq . OF a ♦ r ♦♦.wwsal ON Ea r f11 f P 141� This item has been digitally signed and sealed by Branch Manager Dan J. Zrallack, P.E. on Dec 17, 2020 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL.