HomeMy WebLinkAboutLCR SIGNS, AMO AUTO CARE SIGN INFOL
SIGNS
ELECTRIC�SIGNAGE
SALES & SERVICE
LICENSED & INSURED
7724s82,5276
WWW.LCRSIGNS.COM
24'S"
0 ILii
_,_l-1i-i s, e._t�
Height: 32"
Height: 20"
162"
ANCHOR SCHEDULE
'TALI FASTFNER5 SHALL 77-1
BESPAIEDEYENLY" F7,
WALLMATERIAL
I ANCHOR TYPE
SPACING
3/8" THREADED RODS WITH MIN
MIN (64)
2" EMBED IN ADHESIVE
TOTAL
CONCRETE (3ksi) or
3/8" TAPCONS OR EQUIV) WITH
MIN (32)
HOLLOW MASONRY
2.5" EMBED
TOTAL
3/8" EXPANSION ANCHORS WITH
MIN (24)
3.5" EMBED
TOTAL
1/2" PLYWOOD
3/8" TOGGLE BOLTS
MIN (40)
TOTAL
(NO ACCESS BEHIND)
1/4" WOOD SCREWS, FULL EMBED
MIN (62)
TOTAL
METAL STUDS OR
#14 METAL SCREWS TO MIN 18ga
MIN (46)
METAL PANELS
STEEL OR 0.090" ALUM
TOTAL
HOLLOW WALL
3/8" THRUBOLTS OR LAGS TO
MIN (24)
(BLOCKING BEHIND)
SOLD BLOCKING BEHIND
TOTAL
REVERSE LIT CHANNEL LETTERS
BIF.'g_ rl]IS i[Ll R
Clear Lexan BeoN --
.Ole" Aluminum Face—
$ealtile Connector
Clip Attachment
LED
LEO Lead Wire t Wh.p )
Clip attachment
PVC Standoff
Seallite Connector- -
LED 118em;nalon -
.090• Aluminum Face
Po ver Supply
Clear Lexan Bade
FRONT VIEW
SIDE VIEW
Wireway with Halo Reverse Lit Channel Letters
Cobalt Blue-Oracal 651
1.5" Stand Offs
2" Returns
Wireway Box Color Benjamin More 2155-20
ST.LUCIE COUNTY
PLAN REVIEW
BLDG:
DATEELE:
DATE
DATE' Z
PLUMB:
DATE:
MECH:
DATE:
$m^
3 M..
=LLM
A n
C
ram
D
z3� _
N2
AMO Auto Care `
REVERSE LIT HALO
i
LED CHANNEL LETTER SET
N
UL LISTED- CONNECTED
3I
TO EXISTING POWER
..
m�
� N
N
e e •
NJ N
,n 6
m
63 OF 331 SQFT USED
0g
a*
E E
o a
c
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
9:11_ F Pxv
'NOT TO SCALE
is 0
2c
en II
�g
V �
�<
General • Benign Kin weeJamewththe NquirsmentsoftbeFla eNlgCode6thEdQ017lfor use rnthm&Wnldethe High &IomyHumnneZo HVHZI.-This engmeedrgcandies onlythestmcuaral intently ofthose systemvomponents,and/or othercrosrmctim eryliatly spedfied hHe[n.•Electrical notes, details,&spedfiatiomare p ridedbyand are the sole iesponsithityoftheelectrical contraLtor.Noelectrical owlew has been performed and recntificandon ofwdi is intended,- Structural design meets requirements ofACl31&14,A15C360.10, ADM1-15,&NOS-15,
Notes: as appikable.• Steel cnmponenls shill be stated, panned, a otherwise pmtmed against mmsion per FIX Sec t1031n212.6.-Alum comporents in contact wnh steel or embedded in mnaete shah be pained or protected as presnrs@N in A11611-15(la), or 0aslk/ceopme Wcm prow".•All exposMfasmras steal be SS. m have a predestine mating Not corrosion protection. •All welding Shag comply nth AWS requlremm -Steel wddiOn. electrode, -Aluminum welds: 4043 filer alloy.•Alum w4unWs: 601 or shaper, U.N.O.