Loading...
HomeMy WebLinkAboutProduct Approval (2) File Copy 2 6I2 ' EXTERIOR RESEARCH&DESIGN, I.I.C. VIEWED Certificate of Authorization#9503 CICHRISTIAN STREET,UNIT#13 OXFORD,CT 06478 QOTRINITY ERD Ci®D COMPLIANCE (203)262-9245 EVALUATION REPORT T. LUCIE COUNTY rl A Entegra Roof Tile,LLC ®CC Evaluation Report E39310.11.11-1-R4 I�s.NTEGRA 1289 NE 9t'Avenue FL7804-R10 R O O F T I L E Okeechobee, FL 34972 �a 7i0 Date of Issuance:11/02/2011 (602)515-6933 r l Revision 4:10/17/2017 SCOPE: ( " This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code (HVHZ)sections noted herein. DESCRIPTION: Entegra Concrete Roof Tiles(HVHZ jurisdictions) LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: ��t�tttfrrn„ .vim C: "Sg4'9g A � -? Z`, The facsimile seal appearing was authorized by Robert Nieminen, Robert J.M.Nieminen,P.E. ��• ,q,f, t=` P.E.on 10/17/2017.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 1,'� Q V;\ ��7 document.Signed,sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity[ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. Q0TmN1TYJERD ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1523.6.5.2 Physical Properties TAS 112 1995 1523.6.5.2 Wind Driven Rain TAS 100 1995 1523.6.5.2.2 Static Uplift Resistance TAS 101 1995 1523.6.5.2.3 Static Uplift Resistance TAS 102 1995 1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 1995 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) TAS 101 P39740.02.12 02/21/2012 ATL(TST3782) Physical Properties RT0624.05-14 07/03/2014 ATL(TST3782) Physical Properties RT0624.04-14 07/07/2014 ATL(TST3782) Physical Properties RT1210.02-15 12/17/2015 ATL(TST3782) Physical Properties RT1210.03-15 12/17/2015 ATL(TST 3782) Physical Properties RT1103.01-15 11/07/2015 ATL(TST 3782) Physical Properties RT1103.02-15 11/07/2015 ATL(TST 3782) Physical Properties RT1103.03-15 11/07/2015 ATL(TST 3782) Physical Properties RT1103.04-15 11/07/2015 ATL(TST 3782) Physical Properties RT1103.05-15 11/07/2015 Miami-Dade(CER1592) HVHZ Compliance 14-0416.12 11/27/2014 Miami-Dade(CER1592) HVHZ Compliance 15-0721.04 11/05/2015 Miami-Dade(CER1592) HVHZ Compliance 16-0112.06 02/25/2016 Miami-Dade(CER1592) HVHZ Compliance 16-0112.07 02/25/2016 Miami-Dade(CER1592) HVHZ Compliance 16-0112.08 02/25/2016 Tile Roof Institute TAS 100,TAS 101,102,102(A) Membership Confirmation Current PRI(QUA9110) Quality Assurance Service Confirmation Exp.11/02/2018 Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-1-R4 j Certificate of Authorization#9503 6"'EDITION(2017)FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 2 of 8 Q0TRINrry I ERD 4. PRODUCT DESCRIPTION: 4.1 1 TAS 112,Type 3a(flat-profile) BERMUDA FLAT,PLANTATION FLAT and HORIZON FLAT I 16' -' 1-1/T4' T 10• r f--- 16' i 2• 10, Bermuda Flat Plantation Flat 40 13" 17-1/4" Horizon Flat Exterior Research and Design,U.C. Evaluation Report E39330.11.11-1-R4 Certificate of Authorization#9503 6T"EDITION(2017)FBC HVHZ EVALUATION FL7804-R30 Entegra Roof Tiles Revision 4:10/17/2017 Page 3 of 8 Q0TRINrry ERD 4.2 1 TAS 112,Type la(interlocking,high-profile) BELLA HIGH"S" 1 13-4" Bella High"S" 4.3 1 TAS 112,Type lb(interlocking,low-profile) ESTATE"S"and HACIENDA Nail Holes 0 • 0 • I I/2„ may, Estate"S"f Hacienda 4.3 TAS 112,Type 2a(non-interlocking,high-profile) GALENA SPANISH"S"and REGAL e e v., 17" 10.1 13 1/4" Galena Spanish"S" Regal Exterior Research and Design,I.I.C. Evaluation Report E39310.11.11-1-R4 Certificate ofAuthori:ation#9503 6i"EDITION(2017)FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 4 of 8 i TRINITY I ERD 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements. 5.3 Fire classification is not part of this evaluation;refer to FBC 1516 or listing by an approved testing agency for fire rating of this product. 5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations. 5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in accordance with TAS 112,Appendix W. 5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment products shall hold current Florida Statewide Product Approval or Local Approval for use in tile roof assemblies in FBC HVHZ jurisdictions. 5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements. 5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar-set or adhesive-set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of RAS 118, RAS 119 or RAS 120,as applicable. 6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment-Based System' in accordance with Roofing Application Standard RAS 127-11 using the data outlined herein. TABLE 1:AERODYNAMIC MULTIPLIERS-X(FT) Tile Batten Application Direct-Deck Application Bermuda Flat 0.189 0.205 Plantation Flat 0.267 0.289 Horizon Flat 0.305 0.330 Bella High"S" 0.349 0.378 Estate"S" 0.267 0.289 Hacienda 0.267 0.289 Galena Spanish"S" N/A 0.235 Rega 1 0.287 0.311 TABLE 2: RESTORING MOMENT DUE TO GRAVITY-M,(FT-LBF) Roof Slope(0) Tile 2:12<0<3:12 3:12<0<4:12 4:12<0<5:22 5:12<0<6:12 6:12<0<7:12 0>7:12 Battens I Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Bermuda Flat 5.22 6.43 5.17 6.37 5.09 6.27 4.98 6.15 4.86 6.00 4.72 5.83 Plantation Flat 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Horizon 7.60 8.32 7.52 8.24 7.41 8.12 7.26 7.95 7.09 7.76 6.89 7.55 Bella High"S" 6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13 Estate"S" 6.14 6.84 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14 Hacienda 5.92 6.80 5.92 6.80 5.82 6.69 5.70 6.55 5.56 6.39 5.41 6.22 Galena Spanish"S" N/A 6.20 N/A 6.13 N/A 6.03 N/A 5.89 N/A 5.74 N/A 5.57 Regal 7.77 8.34 7.77 8.34 7.65 8.20 7.49 8.03 7.30 7.83 7.10 7.61 Exterior Research and Design,U.C. Evaluation Report E39310.11.11-1-R4 Certificate of Authorization#9503 6'"EDITION(2017)FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 5 of 8 QoTmNIWIERD TABLE 3A: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT-MF(FT-LBF) MECHANICALLY ATTACHED SYSTEMS` Fastener Direct-Deck Direct-Deck (min.15/3Z" (min.19/32" Tile Type # Size Shank Clip plywood) plywood) Battens Nail One(1) 10d Smooth or Screw N/A 7.3 9.8 4.9 Nail Two(2) 10d Smooth or Screw N/A 14.0 18.8 7.4 Nail One(1) 10d Smooth or Screw Eave 19.0 19.0 22.1 Nail One(1) 10d Smooth or Screw Field 24.3 24.3 24.2 Bermuda Flat, Nail Two(2) lod Smooth or Screw Eave 31.9 31.9 32.2 Plantation Flat or Nail Two(2) 30d Smooth or Screw Field 35.5 35.5 34.8 Horizon Nail Two(2) 10d Ring N/A 30.9 38.1 17.2 Nail' Two 10d' Ring' N/A 50.31 65.51 48.31 Screw One(1) #8 N/A N/A 30.8 30.8 18.2 Screw Two(2) #8 N/A N/A 51.7 51.7 24.4 1 Installation with a 4-inch the headlap and fasteners located min.2Y-inch from head of tile. Nail One(1)' 10d Smooth or Screw N/A 8.8' 11.8' 4.1' Nail Two(2) 10d Smooth or Screw N/A 16.4 21.9 7.1 Nail One(1)Z 10d Smooth or Screw Eave 19.O2 19.O2 22.12 Nail One(1)Z lod Smooth or Screw Field 24.32 24.32 24.2' Nail Two(2) 10d Smooth or Screw Eave 31.9 31.9 32.2 Estate"S"or Hacienda Nail Two(2) 10d Smooth or Screw Field 35.5 35.5 34.8 Nail Two(2) 10d Ring N/A 27.8 37.4 28.8 Nail' Two(2)1 10d' Ring' N/A 43.0' 67.51 50.91 Screw One(1)Z #8 N/A N/A 25.8' 25.8' 22.92 Screw Two(2) #8 N/A N/A 47.1 47.1 49.1 1 Installation with a 4-inch tile headlap and fasteners located min.2%-inch from head of tile. Z For one(1)fastener installations,utilize hole that is approximately 4%-inch from the interlocking edge. Nail One(1) SOd Smooth or Screw N/A 5.1 6.8 2.8 Nail Two(2) 10d Smooth or Screw N/A 6.9 9.2 7.3 Nail One(1) 10d Smooth or Screw Field 23.1 23.1 19.0 Nail One(1) 10d Smooth or Screw Eave 29.3 29.3 24.0 Nail Two(2) 10d Smooth or Screw Field 27.6 27.6 38.6 Bella High"S",Galena Nail Two(2) 10d Smooth or Screw Eave 38.1 38.1 41.8 Spanish"S"or Regal Nail Two(2) lod Ring N/A 28.6 41.2 19.4 Nail' Two 10d' Ring' N/A 33.1' 48.11 50.91 Screw One(1) #8 N/A N/A 20.7 20.7 18.1 Screw Two(2) #8 N/A N/A 43.2 43.2 29.8 1Installation with a 4-inch tile headlap and fasteners located min.2Y-inch from head of tile. i Exterior Research and Design,I.I.C. Evaluation Report E39330.11.11-1-114 Certificate of Authorization#9503 6'EDITION(2017)FBC HVHZ EVALUATION FL7804-R30 Entegra Roof Tiles Revision 4:10/17/2017 Page 6 of 8 QOTRINITYlERD TABLE 4: ATTACHMENTRESISTANCE EXPRESSED AS A"MOMENT—MF(FT-LBF) MORTAR AND,ADHESM&SET SYSTEMS Note from Entegra Roof Tile, UC: The performance data listed in Table 4 are,based on the respective adhesive manufacturers'test reports and Miami-Dade NOAs.' Entegra Roof Tile, LLC.relies upon the adhesive manufacturers to provide these values for our inclusion, in this FBC HVHZ Evaluation Report "Please'consult the individual adhesive manufacturer for information on product approvals, limitations,erevisions or other information for determining wind load and overturning moment performance: Tile Adhesive Tile Product Product Approval Placement Mf(ft-lbf) "TILE BOND"'by Dow Chemical NOA 16-0222.01 Interdependent(2-paddy) 41 Bermuda "Touch N'Seal Storm Bond"by DAP Foam NOA 16-0421.03 Interdependent(2-paddy) 73 Flat, "Polyset®RTA-1"by ICP Adhesives&Sealants NOA 16-0315.03 Interdependent(2-paddy) 52 Plantation Interdependent(2-paddy) 43 Flat or "Polyset®AH-160"by ICP Adhesives& NOA 17-0322.03 Independent medium add Horizon Sealants P ( paddy,—30 g) 51 Independent(large paddy,—45 g) 92 "TILE BOND"'by Dow Chemical NOA 16-0222.01 Interdependent(2-paddy) 44 "Touch N'Seal Storm Bond"by DAP Foam NOA 16-0421.03 Interdependent(2-paddy) 42 "Polyset®RTA-1"by ICP Adhesives&Sealants NOA 16-0315.03 Interdependent(2-paddy) 44 Estate 5 or Hacienda Interdependent(2-paddy) 50 "Polyset®AH-160"by ICP Adhesives& NOA 17-0322.03 Independent(medium paddy,—30 g) 37 Sealants Independent(large paddy,—54 g) 61 Mortar Various Per RAS 120 21 "TILE BOND'""'by Dow Chemical NOA 16-0222.01 Interdependent(2-paddy) 48 "Touch N'Seal Storm Bond"by DAP Foam NOA 16-0421.03 Interdependent(2-paddy) 52 Bella High "Polyset®RTA-1"by ICP Adhesives&Sealants NOA 16-0315.03 Interdependent(2-paddy) 36 "S",Galena Interdependent(2-paddy) 30 Spanish"S" "Polyset®AH-160"by ICP Adhesives& or Regal Sealants NOA 17-0322.03 Independent(medium paddy,—30 g) 49 Independent(large paddy,—63 g) 94 Mortar Various Per RAS 120 25 7. LABELING: 7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo,as detailed below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. and/or NT R R Labeling:Bermuda Flat,Plantation Flat,Estate"S",Bella High"S",Galena Spanish"S" Exterior Research and Design,LLC. Evaluation Report E39310.11.11-1-R4 Certificate of Authorization#9503 6'"EDITION(2017)FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 7 of 8 TRINITY I ERD and/or H n on Labeling: Horizon Flat,Hacienda,Regal S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: PlantProfiles Okeechobee,FL Bermuda Flat,Plantation Flat, Estate"S",Bella High"S",Galena Spanish"S" Ft. Myers,FL Horizon Flat, Hacienda Deerfield Beach, FL Horizon Flat,Hacienda, Regal 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies,LLC.—QUA9110;(813)621-5777 -END OF EVALUATION REPORT— Exterior Research and Design,U.C. Evaluation Report E39330.11.11-1-R4 Certificate of Authorization#9503 6T"EDITION(2017)FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 8 of 8 i I D¢�1 .a® 9047 Short Chip Cir, Port St. Lucie, FL 34986 Pro'ect TotalsTotal Roof Area - 40.22 . ' St Indard Slope(41M:12) - 40.02 SQ Low Slope(2:12-3c12) - 0.21 SQ High Roof(over 1 st_ory) - 2.89 SQ Rolf Planes - 2.2 Structures - 1 Eaye - 314.68 LF Rake - 27.37 LF Total Perimeter - 342 05 LF Ridge - 61.43 LF } Hip - 256r17 LF Va ley - 81.50 LF Slope Change - 4.34 LF Step Flashing - 54.95 LF Headwall Flashing - 11:24 LF THIS REPORT IS FOR ESTIMATION PURPOSES ONLY AND DOES NOT INCLUDE WASTE,VERIFY ALL DIMENSIONS AND TOTALS BEFORE PURCHASING MATERIALS. THIS REPORT IS THE PROPERTY OF SCOPE TECHNOLOGIES,INC.AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT i I Roof Area Analysis-Structure 1 Plane I Area(sf) I Pitch I Slope I High 9047 Short Chip Cir, Port St. Lucie, FL 34986 A 314 6:12 8 576 6:12 C 80 6:12 D 703 6.12 E 10 3:12 L H F 10 3:12 L H G 113 6:12 47.5 37.1 H 67 6:12 H 1 67 6.12 H 1 ^ 1 317 6:12 �\ K 67 6:12 H D L 37 6:12 M . 42 6:12 s�•_ B % N 39 6:12 C O 2S 6:12 I� Q 67 6:12 H A 14_.. _ / r� w R 17 6:12 T 36 6.12 U 250 6:12 V 307 6:12 ..__-_T_ .�;� V // '� � 19 ;tare.(Si:eep-!I)-,,;K `�'� Totals(SQ) ti ' 3:12 - 02 \',Jos 4i12 - 02 � U �f / Q 6:12 - 39.9` jA- •" / I z- -----•-- `.! L''r Low 02 16.5 j br' High - 29 v`1R ' f" S 6.2 e' N \ T 51.5 Drawing KeyO ---Fave —Hip --•----Ridge Parapet —Gear Story ----- Headwall Flashing \\\Ice&Water Areas I2 — —Rake Edge ---Valley —Flat Drip Edge --Coping ----- Slope Change ----- Step Flashing Flat Slope Area