HomeMy WebLinkAboutEnergy Codei1
M
µ
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: LOGSDON RESIDENCE
Builder Name: PORT ST LUCIE PROPERTIES /~
Street: JAY GARDENS LANE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
9. Wall Types (1557.3 sgft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1271.70 ft2
b. Frame - Wood, Adjacent
R=11.0 285.58 ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ft2
10. Ceiling Types (1271.0 sqft.)
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0 1271.00 ftz
6. Conditioned floor area above grade (f?)
1271
b. N/A
R= ft2
Conditioned floor area below grade (W)
0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows (128.0 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 150
a. U-Factor: Sgl, U=0.62
45.00 ft2
SHGC: SHGC=0.22
b. U-Factor: Sgl, U=0.58
43. 0 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.24
a. Central Unit
35.6 SEER:19.00
c. U-Factor: Sgl, U=0.65
40. 0 ft2
SHGC: SHGC=0.21
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
z
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
1.000 ft.
Area Weighted Average SHGC:
0.224
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1271.0 sgft.)
Insulation Area
EF:0.980
a. Slab -On -Grade Edge Insulation
R=0.0 1271.00 ft2
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
None
Glass/Floor Area: 0.101
Total Proposed Modified Loads: 42.03
PASS
Total Baseline Loads: 49.44
I hereby certify that the plans and specifications covered by
Review of the plans and
0 CUE S-r
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
c,�� �i�,''� ` __-��;��`
with the Florida Energy Code.
PREPARED BY:
DATE. -1 4-2iQn
Before construction is completed
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, es' ed, is i mpIi a
Florida Statutes.
5
COD
with the Florida Energy Code.
WE
OWNER/AG/.T
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
7/14/2020 12:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
I
FORM R405-2017 INPUT SU
9MARY CHECKLIST REPORT
v
0-
Title:
LOGSDON RESIDENCE
Building Type:
User
Owner Name:
# of Units:
1
Builder Name:
PORT ST LUCIE PROPERTI
Permit Office:
ST LUCIE COUNTY
Jurisdiction:
ST LUCIE COUNTY
Family Type:
Single-family
New/Existing:
New (From Plans)
Comment:
PROJECT
Bedrooms:
3
Conditioned Area:
1271
Total Stories:
1
Worst Case:
No
Rotate Angle:
0
Cross Ventilation: No
Whole House Fan: No
Address Type:
Street Address
Lot #
Block/Subdivision:
PlatBook:
Street:
JAY GARDENS LANE
County:
St. Lucie
City, State, Zip:
FORT PIERCE,
FL,
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Entire House
1271 12459.6
SPACES
Number
Name
Area Volume
Kitchen Occupants.
Bedrooms
InfilID
Finished
Cooled
Heated
1
BEDROOM 3
147
1190.7
No
0
1
1
Yes
Yes
Yes
2
CLST 2
16
130
No
0
1
Yes
Yes
Yes
3
BEDROOM 2
140
1134
No
0
1
1
Yes
Yes
Yes
4
BATH 2
48
388.8
No
0
1
Yes
Yes
Yes
5
LINEN
6
48.6
No
0
1
No
Yes
Yes
6
W/D
15
121.5
No
0
1
No
Yes
Yes
7
CLST 3
16
129.6
No
0
1
Yes
Yes
Yes
8
KITCHEN
123
1476
Yes
0
1
Yes
Yes
Yes
9
HALLWAY
45
364.5
No
0
1
No
Yes
Yes
10
FOYER/GREAT RM
300
3600
No
0
1
Yes
Yes
Yes
11
DINING
132
1584
No
0
1
Yes
Yes
Yes
12
MASTER BEDROO
195
1579.5
No
0
1
1
Yes
Yes
Yes
13
M BATH
58
469.8
No
0
1
Yes
Yes
Yes
14
M WIC
30
243
No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 3
24 ft 0
147 ft2
----
1
0
0
2 Slab -On -Grade Edge Insulation
CLST 2
2 ft 0
16 ft2
----
1
0
0
3 Slab -On -Grade Edge Insulation
.
BEDROOM 2
23.9 ft 0
140 ft2
----
1
0
0
4 Slab -On -Grade Edge Insulation
BATH 2
6 ft 0
48 ft2
----
1
0
0
7/14/2020 12:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FnRM Rangy-9n17 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulation
LINEN 1 ft
0
6 ft2
____
1
0
0
6 Slab -On -Grade Edge Insulation
W/D 1 ft
0
15 ft2
____
1
0
0
7 Slab -On -Grade Edge Insulation
CLST 3 2 ft
0
16 ft2
____
1
0
0
8 Slab -On -Grade Edge Insulation
KITCHEN 12 ft
0
123 ft2
____
1
0
0
9 Slab -On -Grade Edge Insulation
HALLWAY 1 ft
0
45 ft2
____
1
0
0
10SIab-On-Grade Edge Insulation
FOYER/GREAT R 20 ft
0
300 ft2
____
1
0
0
11SIab-On-Grade Edge'lnsulation
DINING 12 ft
0
132 ft2
____
1
0
0
12SIab-On-Grade Edge Insulation
MASTER BEDRO 13 ft
0
195 ft2
____
1
0
0
13SIab-On-Grade Edge Insulation
M BATH 16 ft
0
58 ft2
____
1
0
0
14SIab-On-Grade Edge Insulation
M W IC 5 ft
0
30 ft2
____
1
0
0
ROOF
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Composition shingles 1421 ft2
0 ft2
Medium
N
0.6
No 0.9
No 0
26.6
ATTIC
V # Type
Ventilation
Vent Ratio (1
in)
Area
RBS
IRCC
1 Full attic
Vented
150
1271 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
BEDROOM 3
30
Blown
147 ft2
0.1
Wood
2 Under Attic (Vented)
CLST 2
30
Blown
16 ft2
0.1
Wood
3 Under Attic (Vented)
BEDROOM 2
30
Blown
140 ft2
0.1
Wood
4 Under Attic (Vented)
BATH 2
30
Blown
48 ft2
0.1
Wood
5 Under Attic (Vented)
LINEN
30
Blown
6 W
0.1
Wood
6 Under Attic (Vented)
W/D
30
Blown
15 ft2
0.1
Wood
7 Under Attic (Vented)
CLST 3
30
Blown
16 ft2
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
123 ft2
0.1
Wood
9 Under Attic (Vented)
HALLWAY
30
Blown
45 ft2
0.1
Wood
10 Under Attic (Vented)
FOYER/GREAT R
30
Blown
300 ft2
0.1
Wood
11 Under Attic (Vented)
DINING
30
Blown
132 ft2
0.1
Wood
12 Under Attic (Vented)
MASTER BEDRO
30
Blown
195 ft2
0.1
Wood
13 Under Attic (Vented)
M BATH
30
Blown
58 ft2
0.1
Wood
14 Under Attic (Vented)
M W IC
30
Blown
30 ft2
0.1
Wood
7/14/2020 12:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
=norm Dnnr-onot7 INPI IT SIIMMARY CHFCKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing
Framing
Solar
Below
To
IN Space
Type
1
N
Exterior
all
Concrete Block - Int InsuBEDROOM 3
4.1 12
0
8
1
97.0 ft2
0
0
0.6
0
_
r2
W
Exterior
Concrete Block - Int InsuBEDROOM 3
4.1 12
0
8
1
97.0 ft2
0
0
0.6
0
_ 3
W
Exterior
Concrete Block- Int Insul CLST 2
4.1 2
0
8
1
16.2 ft2
0
0
0.6
0
4
S
Exterior
Concrete Block - Int InsuBEDROOM 2
4.1 12
0
8
1
97.0 ft2
0
0
0.6
0
5
W
Exterior
Concrete Block - Int InsuBEDROOM 2
4.1 12
0
8
1
97.0 ft2
0
0
0.6
0
_ 6
S
Exterior
Concrete Block - Int Insul BATH 2
4.1 6
0
8
1
48.5 ft2
0
0
0.6
0
7
N
Exterior
Concrete Block - Int Insul CLST 3
4.1 2
0
8
1
16.2 ft2
0
0
0.6
0
8
N
Exterior
Concrete Block - Int Insul KITCHEN
4.1 12
0
12
0
144.0 ft2
0
0
0.6
0
9
S
Exterior
Concrete Block - Int InsuFOYER/GRE
4.1 20
0
12
0
240.0 ft2
0
0
0.6
0
10
E
Garage
Frame - Wood FOYER/GRE
11 11
0
12
0
132.0 ft2
0
0.1
0.6
0
11
N
Exterior
Concrete Block- Int Insul DINING
4.1 12
0
12
0
144.0 ft2
0
0
0.6
0
12
N
Exterior
Concrete Block - Int InsuMASTER BE
4.1 13
0
8
1
105.1 ft2
0
0
0.6
0
13
S
Garage
Frame - Wood MASTER BE
11 13
0
8
1
105.1 ft2
0
0.1
0.6
0
14
N
Exterior
Concrete Block - Int Insul M BATH
4.1 6
0
8
1
48.5 ft2
0
0
0.6
0
_ 15
E
Exterior
Concrete Block - Int Insul M BATH
4.1 10
0
8
1
80.8 ft2
0
0
0.6
0
16
E
Exterior
Concrete Block- Int Insul M W IC
4.1 5
0
8
1
40.4 ft2
0
0
0.6
0
17
S
Garage
Frame - Wood M W IC
11 6
0
8
1
48.5 ft2
0
0.1
0.6
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated FOYER/GRE
None
.39
3
6 8
20 ft2
WINDOWS
Orientation shown is .the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1
Metal Low-E Single Yes
0.62 0.22
Y
15.0 f12
1 ft 0 in
1 ft 4 in
None
None
2
S 4
Metal Low-E Singlg- Yes
0.62 0.22
Y
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
3
N 8
Metal Low-E Single Yes
0.58 0.24
Y
9.0 ft2
1 ft 0 in
1 ft 4 in
None
None
4
S 9
Metal Low-E Single Yes
0.58 0.24
Y
30.0 ft2
1 ft 0 in
1 ft 4 in
None
None
5
N 11
Metal Low-E Single Yes
0.65 0.21
Y
40.0 f12
1 ft 0 in
1 ft 4 in
None
None
6
N 12
Metal Low-E Single Yes
0.62 0.22
Y
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
7
E 15
Metal Low-E Single Yes
0.58 0.24
Y
4.0 ft2
1 ft 0 in
1 ft 4 in
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
380 ft2 380 ft2
30 ft
8 ft
11
7/14/2020 12:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
cnonn onnr-'n-17 IAIDI IT CI It1lIMARY rWI=rKI IST RFPC)PT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50)
.000436
1453.7 79.8 150.08 .1639 7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1 Electric Strip Heat/
None
COP:1 27 kBtu/hr 1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
Single SEER: 19 35.6 kBtu/hr 1068 cfm 0.8 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt Conservation
1 Electric None
Garage
0.98 50 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
--- Supply ----
# Location R-Value Area
-- Return --- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1 Attic 6 150 ft2
Attic
15 ftZ Default Leakage Attic (Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Coolin [ ] Jan Feb [[ ]]Mar
Heatin[ Jan HFeb [X] Mar
Venting[ j Jan Feb [[X]] Mar
Ceiling Fans:
[ ] A r Ma Jun Jul [X] Au riSe [ ] Oct Nov
[ ] APr l May Jun Jul E ] AuSep [ ] Oct f X} Nov
[X] Apr [ May Jun Jul ] Aug Se [X] Oct [X] Nov
Dec
Dec
Dec
7/14/2020 12:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R4ns-gf117 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (W D)
AM
65
65
65
65
65
65
65
68
68
68
68
•68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68'
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq fit.
f?
ft
0.3
LINEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
W/D
Default(8 Ibs/sq.ft.
f?
ft
0.3
CLST 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER/GREAT RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/s .ft.
ft2
ft
0.3
M W IC
7/14/2020 12:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 85
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location Attic
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. 3
5. Is this a worst case? (yes/no) 5. No
6. Conditioned floor area (sq. ft.) 6. 1271
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.616
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.224
c) Area 7c. 128.0
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
13. Cooling system: Capacity 35.6
a) Split system SEER 19.0
b) Single package SEER
c) Ground/water source SEER/COP
d) Room unit/PTAC EER
e) Other
14. Heating system: Capacity 27.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF 0.98
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
30.0
b) Cross ventilation No
b) Single assembly
11 b.
c) Whole house fan No
c) Knee walls/skylight walls
11 C.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or ceeded) in this h me before final inspection. Otherwise, a new EPL
display card will be completed based insVed code qptliplianj features.
Date: !�q? y a�U2 v
Address of New Home: JAY GARDENS LANE City/FL Zip: FORT PIERCE, FL
7/14/2020 12:13:49 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1