Loading...
HomeMy WebLinkAboutEnergy Codei1 M µ FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: LOGSDON RESIDENCE Builder Name: PORT ST LUCIE PROPERTIES /~ Street: JAY GARDENS LANE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1557.3 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1271.70 ft2 b. Frame - Wood, Adjacent R=11.0 285.58 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1271.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1271.00 ftz 6. Conditioned floor area above grade (f?) 1271 b. N/A R= ft2 Conditioned floor area below grade (W) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows (128.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 150 a. U-Factor: Sgl, U=0.62 45.00 ft2 SHGC: SHGC=0.22 b. U-Factor: Sgl, U=0.58 43. 0 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.24 a. Central Unit 35.6 SEER:19.00 c. U-Factor: Sgl, U=0.65 40. 0 ft2 SHGC: SHGC=0.21 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A z a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.224 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1271.0 sgft.) Insulation Area EF:0.980 a. Slab -On -Grade Edge Insulation R=0.0 1271.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.101 Total Proposed Modified Loads: 42.03 PASS Total Baseline Loads: 49.44 I hereby certify that the plans and specifications covered by Review of the plans and 0 CUE S-r this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance c,�� �i�,''� ` __-��;��` with the Florida Energy Code. PREPARED BY: DATE. -1 4-2iQn Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that this building, es' ed, is i mpIi a Florida Statutes. 5 COD with the Florida Energy Code. WE OWNER/AG/.T BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 7/14/2020 12:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 I FORM R405-2017 INPUT SU 9MARY CHECKLIST REPORT v 0- Title: LOGSDON RESIDENCE Building Type: User Owner Name: # of Units: 1 Builder Name: PORT ST LUCIE PROPERTI Permit Office: ST LUCIE COUNTY Jurisdiction: ST LUCIE COUNTY Family Type: Single-family New/Existing: New (From Plans) Comment: PROJECT Bedrooms: 3 Conditioned Area: 1271 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: JAY GARDENS LANE County: St. Lucie City, State, Zip: FORT PIERCE, FL, CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1271 12459.6 SPACES Number Name Area Volume Kitchen Occupants. Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 3 147 1190.7 No 0 1 1 Yes Yes Yes 2 CLST 2 16 130 No 0 1 Yes Yes Yes 3 BEDROOM 2 140 1134 No 0 1 1 Yes Yes Yes 4 BATH 2 48 388.8 No 0 1 Yes Yes Yes 5 LINEN 6 48.6 No 0 1 No Yes Yes 6 W/D 15 121.5 No 0 1 No Yes Yes 7 CLST 3 16 129.6 No 0 1 Yes Yes Yes 8 KITCHEN 123 1476 Yes 0 1 Yes Yes Yes 9 HALLWAY 45 364.5 No 0 1 No Yes Yes 10 FOYER/GREAT RM 300 3600 No 0 1 Yes Yes Yes 11 DINING 132 1584 No 0 1 Yes Yes Yes 12 MASTER BEDROO 195 1579.5 No 0 1 1 Yes Yes Yes 13 M BATH 58 469.8 No 0 1 Yes Yes Yes 14 M WIC 30 243 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 3 24 ft 0 147 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulation CLST 2 2 ft 0 16 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulation . BEDROOM 2 23.9 ft 0 140 ft2 ---- 1 0 0 4 Slab -On -Grade Edge Insulation BATH 2 6 ft 0 48 ft2 ---- 1 0 0 7/14/2020 12:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FnRM Rangy-9n17 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulation LINEN 1 ft 0 6 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation W/D 1 ft 0 15 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulation CLST 3 2 ft 0 16 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulation KITCHEN 12 ft 0 123 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulation HALLWAY 1 ft 0 45 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulation FOYER/GREAT R 20 ft 0 300 ft2 ____ 1 0 0 11SIab-On-Grade Edge'lnsulation DINING 12 ft 0 132 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation MASTER BEDRO 13 ft 0 195 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation M BATH 16 ft 0 58 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation M W IC 5 ft 0 30 ft2 ____ 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1421 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1271 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 3 30 Blown 147 ft2 0.1 Wood 2 Under Attic (Vented) CLST 2 30 Blown 16 ft2 0.1 Wood 3 Under Attic (Vented) BEDROOM 2 30 Blown 140 ft2 0.1 Wood 4 Under Attic (Vented) BATH 2 30 Blown 48 ft2 0.1 Wood 5 Under Attic (Vented) LINEN 30 Blown 6 W 0.1 Wood 6 Under Attic (Vented) W/D 30 Blown 15 ft2 0.1 Wood 7 Under Attic (Vented) CLST 3 30 Blown 16 ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 123 ft2 0.1 Wood 9 Under Attic (Vented) HALLWAY 30 Blown 45 ft2 0.1 Wood 10 Under Attic (Vented) FOYER/GREAT R 30 Blown 300 ft2 0.1 Wood 11 Under Attic (Vented) DINING 30 Blown 132 ft2 0.1 Wood 12 Under Attic (Vented) MASTER BEDRO 30 Blown 195 ft2 0.1 Wood 13 Under Attic (Vented) M BATH 30 Blown 58 ft2 0.1 Wood 14 Under Attic (Vented) M W IC 30 Blown 30 ft2 0.1 Wood 7/14/2020 12:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 =norm Dnnr-onot7 INPI IT SIIMMARY CHFCKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below To IN Space Type 1 N Exterior all Concrete Block - Int InsuBEDROOM 3 4.1 12 0 8 1 97.0 ft2 0 0 0.6 0 _ r2 W Exterior Concrete Block - Int InsuBEDROOM 3 4.1 12 0 8 1 97.0 ft2 0 0 0.6 0 _ 3 W Exterior Concrete Block- Int Insul CLST 2 4.1 2 0 8 1 16.2 ft2 0 0 0.6 0 4 S Exterior Concrete Block - Int InsuBEDROOM 2 4.1 12 0 8 1 97.0 ft2 0 0 0.6 0 5 W Exterior Concrete Block - Int InsuBEDROOM 2 4.1 12 0 8 1 97.0 ft2 0 0 0.6 0 _ 6 S Exterior Concrete Block - Int Insul BATH 2 4.1 6 0 8 1 48.5 ft2 0 0 0.6 0 7 N Exterior Concrete Block - Int Insul CLST 3 4.1 2 0 8 1 16.2 ft2 0 0 0.6 0 8 N Exterior Concrete Block - Int Insul KITCHEN 4.1 12 0 12 0 144.0 ft2 0 0 0.6 0 9 S Exterior Concrete Block - Int InsuFOYER/GRE 4.1 20 0 12 0 240.0 ft2 0 0 0.6 0 10 E Garage Frame - Wood FOYER/GRE 11 11 0 12 0 132.0 ft2 0 0.1 0.6 0 11 N Exterior Concrete Block- Int Insul DINING 4.1 12 0 12 0 144.0 ft2 0 0 0.6 0 12 N Exterior Concrete Block - Int InsuMASTER BE 4.1 13 0 8 1 105.1 ft2 0 0 0.6 0 13 S Garage Frame - Wood MASTER BE 11 13 0 8 1 105.1 ft2 0 0.1 0.6 0 14 N Exterior Concrete Block - Int Insul M BATH 4.1 6 0 8 1 48.5 ft2 0 0 0.6 0 _ 15 E Exterior Concrete Block - Int Insul M BATH 4.1 10 0 8 1 80.8 ft2 0 0 0.6 0 16 E Exterior Concrete Block- Int Insul M W IC 4.1 5 0 8 1 40.4 ft2 0 0 0.6 0 17 S Garage Frame - Wood M W IC 11 6 0 8 1 48.5 ft2 0 0.1 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated FOYER/GRE None .39 3 6 8 20 ft2 WINDOWS Orientation shown is .the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.62 0.22 Y 15.0 f12 1 ft 0 in 1 ft 4 in None None 2 S 4 Metal Low-E Singlg- Yes 0.62 0.22 Y 15.0 ft2 1 ft 0 in 1 ft 4 in None None 3 N 8 Metal Low-E Single Yes 0.58 0.24 Y 9.0 ft2 1 ft 0 in 1 ft 4 in None None 4 S 9 Metal Low-E Single Yes 0.58 0.24 Y 30.0 ft2 1 ft 0 in 1 ft 4 in None None 5 N 11 Metal Low-E Single Yes 0.65 0.21 Y 40.0 f12 1 ft 0 in 1 ft 4 in None None 6 N 12 Metal Low-E Single Yes 0.62 0.22 Y 15.0 ft2 1 ft 0 in 1 ft 4 in None None 7 E 15 Metal Low-E Single Yes 0.58 0.24 Y 4.0 ft2 1 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 380 ft2 380 ft2 30 ft 8 ft 11 7/14/2020 12:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 cnonn onnr-'n-17 IAIDI IT CI It1lIMARY rWI=rKI IST RFPC)PT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000436 1453.7 79.8 150.08 .1639 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 19 35.6 kBtu/hr 1068 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS --- Supply ---- # Location R-Value Area -- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 150 ft2 Attic 15 ftZ Default Leakage Attic (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Coolin [ ] Jan Feb [[ ]]Mar Heatin[ Jan HFeb [X] Mar Venting[ j Jan Feb [[X]] Mar Ceiling Fans: [ ] A r Ma Jun Jul [X] Au riSe [ ] Oct Nov [ ] APr l May Jun Jul E ] AuSep [ ] Oct f X} Nov [X] Apr [ May Jun Jul ] Aug Se [X] Oct [X] Nov Dec Dec Dec 7/14/2020 12:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R4ns-gf117 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 •68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68' 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq fit. f? ft 0.3 LINEN Default(8 Ibs/sq.ft. ft2 ft 0.3 W/D Default(8 Ibs/sq.ft. f? ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER/GREAT RM Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/s .ft. ft2 ft 0.3 M W IC 7/14/2020 12:13 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 85 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. ft.) 6. 1271 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.616 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.224 c) Area 7c. 128.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: 13. Cooling system: Capacity 35.6 a) Split system SEER 19.0 b) Single package SEER c) Ground/water source SEER/COP d) Room unit/PTAC EER e) Other 14. Heating system: Capacity 27.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 C. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or ceeded) in this h me before final inspection. Otherwise, a new EPL display card will be completed based insVed code qptliplianj features. Date: !�q? y a�U2 v Address of New Home: JAY GARDENS LANE City/FL Zip: FORT PIERCE, FL 7/14/2020 12:13:49 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1