Loading...
HomeMy WebLinkAboutProject InformationProject Summary pat - - wrightsoft Endre' House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@10L.COM. Project • • For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Notes: h..<Z—� � `�SN� Desicin Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible:Cooling Equipment Load Sizing Structure 18467 Btuh Structure 17655 Btuh Ducts 6190 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none e). Humidification 0 Btuh Blower 0 Btuh . Piping 0 Btuh Equipment load 24657 Btuh Use manufacturers data n ' Infiltration Rate/swing multiplier Equipment sensible load 0.95 25645 Btuh . Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 cfm) 0 . Btuh Heatingg Cool" ngg Area (none) (ftz) 1753 1753 Equipment latent load 5007 Btuh Volume (ft3) 14741 14741 Air changeslhour 0.38 0.20 Equipment total load 30652 Btuh Equiv. AVF.(cfm) 93 49 Req. total capacity at 0.70 SHR 3.1 ton Heating Equipment Summary Cooling .Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 34 OF 8.5 HSPF 34600 .Btuh @ 47OF 27 OF 1160 cfm 0.047 cfm/Btuh 0.50 in H2O Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh. Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160. cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Loadsensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed C WrightSOft" 2017=Apr-1017:19:28 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 i�• k Calcs\DocumentsMYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N + - wr yhtsoft° Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By:. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@!10LCOM 1 Room name Entire House MASTER BEDROOM 2 =ad wall 153.0 ft 45.0 ft 3 Room height 8.4 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 280.0 ft. 5 Room area 1753.0 ftz 280.0 ft' Ty Construction U-value Or HTM Area(ft2) Load Area (ft-) Load number (Btuh/ft2�`F). (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat . Cool 6 13A-0ocs 1Ac1om 1A 0143 1270 'ne ne: A.00 35;56 2 95 7043 488 7 448 :1795 0 247 .1 488 192 192 0 769 0 0 489. 0 c1om 7 270 ne . 35 56 7093 16 0 581 1151 0 1A�1om:: 1 270 .me'T .. 35;56 4524 . .16 . 0 _.. 581 ,..: 739 : , 0 ' .. 0. ;0 ;t0 11 �D 13A4ocs 0.143 se 4.00 Z55 64 41 165 105 0 0 0 0 .11D0 0390 se 10.92 11.31 23 23 248 2'�7 0 0 0 0 V� r 13A flocs : ;,0143 SW, 4.00 2:55 437 396 :1584 1007 56 56 224 1,43 r—C'. _4A5 tom . ,. _ .. 0 770 •: svy' 2t .. 27.53 41 ., ' 45 893 :..; .1140 . —G 13A4ocs 1Ac1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 290 33 .217 0 867 1162 551 1478 112 33 79 0 318 1162 202 1478 r---G P s 4A -2omd - 0.770 nw 21.56 36.90 41 0 . 880 1505 0 0 0 . 0 2C-0sw -2,55 128 . ; : :308 308 ; _ 784 ; . 395 " :' 0 ` C 16A-30md 0 032 - 0,90 2.32 1763 1753 1571 4067 280 280 251 650 "27 69 Ui00 :1753 . A65 ' �4237, . i _ 0 `. '.: - 280 't 4$ ; 1246 ... ..... 6 c) AED excursion 1360 600 Envelope loss/gain 15594 15385 3970 351i1 12 a) Infiltration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 290 2 460 p Appliances/other 1000 0 0 Subtotal Vines 6 to 13) 18467 17655 4779 3789 Less extemal load 0 0 0 Less transfer 0 0 0 0 0 Redistribution 0 0 02 14 15 Subtotal Duct loads 18467 17655 4779 37890 -T 34% 53% 6190 9340 34% 53% 160 2005 Total room load Air required (cfm) 24657 26995 6380 5794 1160 1160 3p0 249 Calculations approved bVACCA::to meet all reouirements of Manual J 8th Ed .49& -Fk- wrightSC ft-Right-Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:28 ...k Calcs\Documents%WYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N Page 1 - wrightsoft' Right-M Worksheet Job: Entire House Date: By: QUICK CALLS, INC. 317 ST. LUCIE,LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email; QUICKCALCS ,AOL.COM 1 Room name WIC M. BATH ad wad] Oft 7 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4. Room dimensions 7.0 x 9.0 ft 1.0 x 61.0 ft 5 Room area 63.0 ftz 61.0 ft2 Ty Construction U-value Or HTM Area (ft') Load Area : (ft5 Load number (Btuh/ft;°F). (BtuWft') or perimeter (ft) (Btuh). or perimeter -. (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross NIP/S Heat Cool 6 :13A flocs . ` 0143 ne 4 00 2.55 0 0 0 0 56 49 196 125 X-1' 1270 ne. 35 5ti 70.43 0 0 0 ' 0 7 = 0 247 488. 1Ac1om , 1270 ne. 3556 70.43 0 0 0 0 0 :'0 0 0` 1A�1om :; 1.270 . ne 35,56 45:24 .. 0 . 0 . . 0 ... 0 °. 0 11 W 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 __p 11DO 0.3 se 10.92 11.31 0 0 0 0 0 0 0 0 13Aflocs, 0143 sw. 4:00 255 0 . , p „0 .: U' : ' 0 0 _ 0 0. :'4A52om :' 0.770 -sw. 21 56 . 27.53 0 .,. 0 - p ,, -0 . 0 "'.. U . U : :,;0, V�l 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 l�r 1Ac1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5.2omd 0.770 nw 21.56 36,90 0 0 0 0 0 0 0 0 P 00-0sw.. . ; 0 091 . 255 1;28 0 0 0. 0 0 ;;0 C 16A-30md 0.032 - 0.90 2.32 63 63 56 146 61 61 55 142 0.00 :. ., 0 ` >' 0 :; .:. : •.0 -. '.61 7 ` . 194, . 0 6 c)AED emulsion -5 -26 Envelope loss/gain 56 141 692 729 12 a) Infiltration 0 0 b) Room ventilation 126 35 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 Appliances/other . p p 0 Subtotal (lines 6 to 13) 56 141 817 764 Less wdemal load 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 15 Subtotal Duct loads 56 141 0 g1 0 764 34% 53% 19 . 75 $4% 53% 274 404 Total room load Air required (cfm) 75 216 1091 1168 4 9 51 50 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed A&k -F - wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:28 ... k Calcs%Documents%WYNNE-THE WINDSOR-REVISED.rug Calc = MJ8 Front Doorfaces: N Page 2 -�- wrilghtsoft®. Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By 317 ST..LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: ..QUICKCALCS ,AOL.COM 1 Room name LAUDRY BEDROOM 2 2 - =ed wall 0 ft 12.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 . Room dimensions . 6.0 . x 6.0, ft 15.0 x 12.0 ft 5 Room area 36.0 ft2 180.0 ft2 Ty Construction U-value Or HTM Area (ft(ft2) Load number (Btuh/ft2-°F) (BtuWft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A 4ors • 1A�1om " 0143 :1270 ne; ne 4.00 35'56 2s55 7043 0 0 0 0 0 0 0 0 96 + 80 0; d0 319 0 203, 0 7A�1om : 1270 ne 35:56 7043 : 0 0 0 0 16 '.` A 569 9151,. 1Ac1om,. 1.270 ,-ne 3556 45:24 0 ' 0 0 %0 11 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11DO 0390 se. 10.92 11.31 0 0 0 0 0 0 0 0 yV I--G; 13A-0ocs -- 0143 sw 4:00 2.55 0 0 0 0 : 0 ` :0 0 0 . 4A5 tom 0.77.0 . sw 2156 _ 27.t3 .. :0 0 : 0 :: 0 <' ;'0 ;0 0 13A4ocs 1A-c1om 0.143 1.270 nw - nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 6 0 0 0 �—G 4A5-2omd. 0 770 - nw 21.56 36.90 0 0 0 0 0 0 0 0 C -12C-0sw;'- ;i0 091 : _: 2:55 12g , .. ,p .:. 0 -p 0 .. ; 0 ; .. .0 16A-30md 0.032 - 0.90 2.32 36 36 32 84 180 180 161 418 F.. `: i;22Prtpl' `: ': : :.0 989 =.:- ; ,. ,• 27.69 :: 0.00 : , ...' 36 180 :; 12 6 c)AED exurslon -3 -60 Envelope loss/gain 32 81 1394 1711 12 a) Infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 p p 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 32 81 1609 1772 Less wdemal load p p 0 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 15 Subtotal Ductloads 34% 53% 38 13 95 50 34% 53% 1615 541 1786 945 Total room load Air required (cfm) 5121 1 6 2101 2 101 .17 117 Calculations approved byACCA to meet all requirements of Manual -J.8th Ed -� wrightsoft• 2017-A1017:19:28 A Right -Suite® Universal 2017 17.0.14 RSUG8101 Page 3pr- k Calcs\Documents%WYNNE-THE WINDSOR-REVISED.rup Cale = MA Front Door faces: N r +�- wrightsoft. Right-M Worksheet Job: Entire House ` Date: QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-166-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name DINING_ /GREAT ROOM KrrCHEN wadi 0 ft 11.0 ft 3 Room�he 9h 8.9 ft heat/cool 8.9 ft heat/cool 4 Room dimensions 1.0 x 588.0 ft 19.0 x 11.0 ft 5 Room area 5W.0 ft2 209.0 ft2 Ty Construction U-value Or HTM Area 2 kea number. (Btuh/ft2-°F). (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs: 0143 ne 4:00 2,55 0 0 0 0 0 A p U 1A c1om ° 1270 ne'- 35.56 70 43 0 0 0 0 .. 0 : p ;0 0: 1Ac1om ;1270 ne; 35 56 70.43 U 0 0 0 ;: 0 0 0 0 1Ac1om ; . 1 270 ne: 35;56 45:24 . 0 0': 0 ; ., 0 :0 11 V�/ 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 .0 0 �D 11DO 0390 se 10.92 11.31 0 0 0 0 0 0 0 0 13Aoq§ : , .. 0143 sw;: 4i00 2;55 267 : 226 903 574 98 .: 98 392 249 0 770 . §w. 2156 2753 41 _ . ' ,. 22 . 893 _. 1140 .'.., 0 :.. :-0 , :. ;0. 13A-4ocs ' 0.143 nw 4.00 2.55 178 137 549 349 0 0 0 0 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5.2omd 0.770 nw 21.55, 36.90 41 0 880 150 0 0 0 0 12I3 :. 0 ', '. .., 0 ; , ': 0 11.6 _:. -:116 . :.295 J148 C 16A,30md 0.032 0.90 2.32 588 588 527 1364 209 209 187 485 F ... =22A-tpl . - _• ,; 0 989 . ; _ : 27.69 :: < , 0:06 . •. 588 , 50 ::.A385 1: ` ' 0 :.. 209',' . ;11 6 c)AED e)xursion 1004 -64 Envelope loss/gain 5136 5937 1179 818 12 a) Infiltration 1000 282 22p 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other p 1000 Subtotal (lines 6 to 13) 6136 6679 1399 1880 Less extemal load 0 0 0 0 Less.transfer 0 0 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 15 Duct loads 34% 53%1 2058 . 3541 340/6 53%1 469 995 Total room load 8200 10234 1867 2875 Air required (cfm) 386 '440 88 124 Calculations approved byACCA to meet all requirements of Manual J 8th Ed .A '- wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:28 :.k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup .Calc = MJ8' Front, Door faces: N Page 4 - wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALLS, INC. By 317 ST. LUCIE LN., FT. PIERCE, FL 34946-Phone: 772-466.6799 Fax 772-466-6796 Email: QUICKCALCWOL.COM 1 Room name BATH HALL 2 Exposed wall 5.0 ft 0 ft 3 Room height 8.0 It heat/cool 8.0 ft heat/cool 4 . Room dimensions .10.0 x 6.0 ft 5.0 x 5.0 It 5 Room area 50.0 ft2 25.0 ft2 Ty Construction U-value Or HTM Area (ft-) Load (ft2) Load number (BtuWft7-°F) (Btuh/ft2) or perimeter (ft) (Btuh) oorperimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WPM Heat Cool 6 Aocs: 1Ac1om ' 0143 1 270 ne: rie 4:00 35:56 2,55 70 43 40 40 0 0 160 102 0 0 0 ; :0 0 `0 0 I i0 •0. 0 1Ac1om - 1270 ne 3556 7043 0 0 0 0• 0; 0 I 0 b ,1A c1om:127.0 .ne 35.56 ..4524 0 0 .. • ' 0 0 .: 0 : 0 11 V1J 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 �D 11DO 0.390 se 10.92 11.31 0 0 0. 0 0 0 0 0 13figks- 0143 "sw 4' 00 2 55 0 0 0 0 0 . 0 -: 1-;0 :0 -G'.4Q52om; -0;770 .aw 21 56.. -2753.;;0 13AAocs 1A-c1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2omd. 0.770 my - 21.56 36.90 0 . 0 0 .0 0 0 0 0 p. K12C-0sw ; 0 091 . • 755 128 : 0 , , 0 .... 0 '.' 0 _ 0 : '•0 .... ' ., 0 C 16A-30md 0.032 - 0.90 2.32 50 50 45 .. 116 .: 25 , 25 22 58 F '22Atpl,;:: ; ,'0989 •. -: 27s,69 ;.: 0.00 _ - : , :. 50 •:-' 5 138 : ' -0 ,. .25 :. 0. 6 c)AED excursion 8 -2 Envelope loss/gain 343 210 22 56 12 a) Infiltration g0 25 0 b) Room ventilation 0 0 0 .0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to.13) 433 235 22 56 Less mdemal.load 0 0 0 0 Less transfer 0 0 0 Redistribution 6 14 "� 6 '� 14 Subtotal 439 249 0 0 15 Ductloads 34% 53% 147 132 340/a 53% 0 0 Total room load 586 381 0 0 Air required (cfm) .28 16 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed .A -- wrfightrsoft� Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:28 ..:k CaIcslDocumentslWYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N Page 5 - wrightsoft° "Right-JO Worksheet Job: Entire House Date` QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946.Phone: 772-466-6799 Fax 772-466-6796 Email:. QUICKCALCS@AOL.COM 1 Room name FOYER BEDROOM 3 2 E�osed wall. 9.0 ft 14.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 92.0 ft 92.0 ft2 13.0: x 13.0 ft 169.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) .(Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 11 V�/LO t--G 13A-0ocs 1Ac1om 1Ac1om ` 1Ac1om- : 13AAocs 11130 13A-0ocs AA5.2om 13A4ocs 1Ac1om 4A5.2omd 0143 1270 1270 1.270 0.143 0.390 6143 :.0.770 0.143 1.270 .0.770 ne ne ne: ne: se se sw. '.sw: nw nw nw 4 00 3566 3556 35.56 4.00 10.92 4:00 .2Tc56 4.00 35.56 21.56 285 7043 7043. 45524 2.55 11.31 2 55 2753 2.55 45.24 36.90 0 0 64 23 8 0 0 0 0 0 0 0 0 0 . 0 41 23 . t3 '.. 0 0 0 0 0 0 0 0 165 248 32 0 0 0 0 0 0 0 0 105 257 20 .' 0 0 0 0 104 0 0.. .. 16 0 0 „• . 8 -.' 0 0 0 0 ` 88 0 0 "" _ :0 0 0 - 8 '.. 0 0 0 0 351 0 581 0 0 32 A 0 0 0 223 0; .. 739 0 0 20 ";0 0 0 0 P 12GOsw` 0.01 1 2 55 128 : 88 88 ' 224 . 113 04 -: 104 265 1 M C .16A30md 0.032 0.90 2.32 92 92 82 213 169 169 151 392 F ..:22A tpl? .: 0 989 .. :' 27.69 . 0 00 :.: . '92 > 9 .. ..: 249 ..: 0 6 c)AED excursion -25 -52 Envelope loss/gain 1002 684 1768 1456 12 a) Infiltration 162 461 252 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1163 730 2020 1527 Less eMemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1 2020 1527 15 Duct loads 34% 53% 390 386 34% 53% 677 808 Total room load 1553 .1116 2697 2335 Air required (cfm) 73 48 127 100 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed A&.k -F�- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:28 ...It CaIcslDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N Page 8 Duct System Summary Job: wrightsoft° y Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Heating. Cooling Externalstatic pressure 0.50. in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available.static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.273 in/100ft 0.273 in/1'00ft Actual air flow 1160 cfm 1160 . cfm Total effective length.(TEL) 183 ft SupplyDetail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam . (in) H x W (in) Duct Mat[ Actual Ln `(ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 Ox0 VIFx 19.5 115.0 st1 BEDROOM c 2730 101 117 0.384 7.0 Ox0 VIFx 15.0 115.0 st1 BEDROOM 3 h 2697 127 100 0.353 6.0 Ox0 VIFx 26.8 115.0 st1 DINING/GREAT ROOM C 3411 129 147 0.292 7.0 Ox0 VIFx 36.5 135.0 st2 DINING/GREATROOM-B C 3411 129 147 .0.371 7.0 Ox0 VIFx 19.9 115.0 st1 DINING/GREAT ROOM-C C 3411 129 147 0.278 7.0 Ox0 VIFx 44.9 135..0 st2 FOYER h 1553 73 48 0.490 4.0 Ox0 VIFx 7.0 95.0 KITCHEN c 2875 88 124 0.366 6.0 Ox 0 VIFx 21.8 115.0 st1 LAUDRY c 145 2 6 0.371 4.0 ox0 VIFx 19.9 115.0 st1 M. BATH h 1091 51 50 0.282 6.0 Ox0 VIFx 42.3 135.0 st2 MASTER BEDROOM h 31.90 150 124 0.273 6.0 Ox0 VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 Ox 0. VIFx 40.9 135.0 st2 WIC c 216 4 9 0.292 4.0 Ox0 'VIFx 36.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 612 602 0.273 780 12.0 0 x 0 VinlFlx st1 st1 PeakAVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx wrightsoftg Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:29 Page 1 k CalcMDocuments\WYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N 0 Name Grille Size (in) Htg (cfm) Cig (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) . H x W (in) Stud/Joist . Opening (in) Duct Matl Trunk rb1 ox0 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft` 2017-Apr-1017:19:29 �, 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ZC�....k' Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N