HomeMy WebLinkAboutJAT 5V-2017mil"A
BC1S Home Log In User Registration - Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search
da..Y(A
Product Approval
USER: Public User
1W
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
�dJlh;'
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL17443-R1
Revision
2017
Approved
J A TAYLOR ROOFING
302 Melton Drive
FT PIERCE, FL 34982
(772) 466-4040
kylewhite228@aol.com
Kyle Taylor
kylewhite228@aol.com
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Locke Bowden
Evaluation Report
Florida License
PE-49704
Quality Assurance Entity
PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date
01/23/2023
Validated By
Zachary R. Priest, P.E.
" Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL17443 R1 COI FL 17443 J A Taylor 2017 Code Eval Report with Details
RSSS.p_if
Standard
Year
TAS 125
2003
UL1897
2012
UL580
2006
Product Approval Method
Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
FL # Model, Number or Name
01/24/2018
02/14/2018
02/17/2018
04/10/2018
17443.1 5 V Crimp
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-129.25
Other:-129.25 @ 6" o.c. -69.25 @16" o.c. margin of safety
2:1 with 24" max. coverage Install per manufacturers detail.
Not for use in HVHZ.
17443.2 VICTORIAN CRIMP SHINGLE
i
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-105
Other:-105PSF margin of safety 2:1. Install per
manufacturer's details and in compliance with FBC 2017 5th
ed. Not for use in HVHZ.
Description
26GA 1/2" rib height over 15/32" APA plywood
Installation Instructions
FL17443 R1 II FL 17443 J A Taylor 2017 Code Eval Report
with Details RSSS.pdIF
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17443 R1 AE FL 17443 3 A Taylor 2017 Code Eval Report
with Details RSSS.pdf
Created by Independent Third Party: Yes
26GA 1/2" RIB- PANELS LOCK INTO PREVIOUS PANELS; OVER
CDX/APA 15/32" PLYWOOD
Installation Instructions
FL17443 R1 II FL 17443 J A Taylor 2017 Code Eval Report
with Details RSSS.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17443 R1 AE FL 17443 ] A Taylor 2017 Code Eval Repo
with Details RSSS.pdf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Q2pyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
Credit Card
Safe
Product Report Manufacturer: 1 A Taylor Roofing Inc.
302 Milton Drive
Fort Pierce, Fl. 34962
(772) 466-4040
Compliant with Florida Building Code 2017 (6" ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant Quality Assurance Program: PRI CONSTRUCTION MATERIALS TECHNOLOGY
FBC Sections: 1504.3.2,1507
5V Crimp thru fastened %" rib at each panel edge and 1 fastener in the center of the panel, 24" net coverage, 26GA ASTM
A792, G-50, AZ55, .018, 50ksi min. over min.15/32" thick CDX plywood deck. Corrosion Resistant fastener #9-15 HWH with
sealing washers, metal to wood connections with fastener length to penetrate 5/16" thru substrate. Fasten along the crown
of the rib in the center of panel and along the lap. First fastener to be within 3" of panel edges. Min. 8Dx2" annular ring shank
nails spaced 6" O.C. reroofing, with less than 19/32" plywood (min.15/32"), this attachment is to be used in addition to
existing attachment. Deck slope 2:12 or greater and shall be compliant with FBC 2017 6T" ed. Underlayment: See FBC 2017 61"
ed., Sec. 1507 Table 1S07.1.1
**Design Pressure:
Spacing:
-69.25 PSF
16" O.C.
-129.25 PSF
6" O.C.
�• - ••A Plywood NON-HVHZ,
26GA ASTM A792, G-50, AZ55, .018, SOksi Victorian Crimp Shingle over 15/32" COX/APA Plywood attached to roof trusses.
Corrosion Resistant Fastener #10 x 1" Zinc plated, MTW Pancake Head, installed at 2 per panel into lock seam. Panels applied
with 12" exposure, adjacent shingles inserted into lock seam of previous shingle. Deck slope 2:12 or greater and shall be
compliant with FBC 2017 6T" ed. Underlayment: See FBC 2017 6T" ed., Sec.1507 Table 1507.1.1
**Design Pressure:
-105 PSF
"DESIGN PRESSURE INCLUDES A SAFETY MARGIN OF 2:1
Reference Data:
TEST REPORTS
Hurricane Test Laboratory (TST-1527) #0224-0501-06 TAS 125 JUL 58G-942)
PRI Construction Materials Technologies (TST-5878) #FAE-023-02-01 UL 580-06/UL 1897-042
1. UL 580-94 test standards are equivalent to UL 580-06 test standards.
2. UL 1897-04 test standards are equivalent to UL 1897-12 test standards.
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6T" ed.. see Chart 1507.1.1
2. Minimum slope to be compliant with Florida Building Code 2017 61h ed., and per with Manufacturer's installation reference.
3. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered
engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 61h ed., Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a financial interest in any company manufacturinj eTf ; q buting products
under this evaluation. ``��� bow `frrh,rr�
Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer, or� ililk- it ro�IJI j%t�ur 4er this
report. ��G`t-.•OE�1E •• '.
9 �q
seal No • .
• �/ /z
ow
FLOk
", ,!Ssi'�0N�P� ��.�.
5 V Crimp
Fastener- #9-15 corrosion resistant w/sealing washers
24" coveraae
,
Fastener: #9 x 15 corrosion resistant with sealing washers
in Compliance with 2017 Florida Building Code, Section 1507
Perimeter fastening: 6"o.c.
Main Field fastening 1 2"o.c.
Panel Width: 26"
Panel Coverage: 24"maximum
26 GA Architectural Metal Roof panel
VICTORIAN CRIMP SHINGLE
LOCK SEAM
MINIMUM 2 FASTENERS
AT LOCK SEAM
FIELD CUT 1/2 SHINGLE
TO CREATE STAGGERED
PATTERN
VICTORIAN CRIMP
SHINGLES
N
Fastener:#10 x 1 "
Zinc Plated MTW
Pancake Head
9"EXPOSURE