HomeMy WebLinkAboutBuilding PlansNOV 2 7 2019 ST. Lucie County, Pern 12" . H. Finish Columns with 5/8" thick cut coral finished stucco bands Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12 26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5" wood screws with self sealing washer at 12" o.c. max spacing over ASTM D (type 2) 30 lb felt underlayment installed with min. 4 aide laps and L" end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails spaced 6 o.c. at all laps and two staggered rows 12" o.c. in field. Attach deck to trusses using attachment detail on this sheet 5/8" thick light textured o O stucco on typical concrete �. block construction 5/8" thick x 8"w cut coral finished stucco bands RiGHT ELE\/ATiON 12 4 1 SLOPE. SCALE: 1/4" = 1'-0' 12 SLOPE 14 8'-I" T.O.B. 0'-0" = Finished Floor ELE\/ATiON NOTES: Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 911451.12 26 go. 5v crimp metal roofing attached to plywood deck using 49 x 1.5" wood screws with self sealing washer at 12" o.c. max spacing over ASTM D (type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails spaced L" o.c. at all laps and two staggered rows 12" o.c. in field. Attach deck to trusses using attachment detail on this sheet 12 4 1 SLOPE, - III Finish Columns with 5/8" thick cut coral finished stucco bands REAR - Overhangs at I'-O" unless otherwise noted on Roof Plan - Roof pitch at 4:12 unless otherwise noted - Ang changes to this plan shall be submitted to the architect for approval In writing prior to starting construction. Gulf Coast Supply and MFG 5v Crimp Metal roofing. FL #IIL51.12 2L ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5" - Return ALL Stucco Bands Into Window or Door. woad screws with self sealing washer at 12" o.c. max spacing over ASTM D 1112) 30 lb felt underlayment installed with min. 4 side laps and V end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails spaced L" o.c. at all laps and two staggered rows 12" o.c. in field. Attach deck to trusties using attachment detail on this sheet 12 4 SLOPE 5/8" thick x 8"w cut coral finished stucco bands \ 5/8" thick light textured stucco on typical concrete block construction ELE\/ATION SCALE: 1/4" = 1'-0" Gulf Coast Supply and MFG Sv Crimp Metal roofing FL #11G51.12 26 ga- 5v crimp metal roofing attached to plywood deck using #9 x 1.5" wood screws with self sealing washer at 12" o.c. max spacing over ASTM D (type 2) 30 lb felt underlayment installed with min. 4 side laps and V end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails spaced L" o.c. at all laps and two staggered rows 12" o.c. in field- Attach deck to trusses using attachment detail on this sheet 1/8" Thick cut coral stucco over paper backed wire lath nailed to substrate through one layer of 15 lb felt using 8d nails. Substrate to be 19/32" COX Plywood nailed at 6" o.c. in field and edges with IOd ring shank galvanized nails into truss webbing. 12" 12" 2„ ° ❑ 5/8" thick x 8"w cut �.O.H.5/8" thick x 8"w cut 3 coral finished stucco bands 3 coral finished stucco bands a O ®®"® 5/8" thick light textured stucco on typical concrete block construction - - are a Finished Floor Finished lour - - - - -O'-4" A.F.FD10100*1. 5/8" thick light textured stucco on typical concrete block construction LEFT ELEVATiON FRONT ELEVATiON SCALE: 1/4" = 1'-0" SCALE: 1/4" I'-O" Product Approval Submittal Affidavit Opening Schedule Swing Doors, Overhead Doors, Sliding Doors, Windows do Skylights Type NOA/FL NUMBER Product Model Manufacturer Glass Attachment method TESOpening Expiration Date Design Pressure of Approved Teats 1,2,3 E4 FLU 239.3 Single Hun g g SH-100 Impact PGT 5/I4" Vq' dia. tapcons w/ min. 19/8' penetration to be spaced per product. approval. Contractor shall adhere to min. edge distances specified in Product approval + 80.0 PSF - A 16-0330.02 Overhead Garage Door Model 8. width 9'-4" max width I6'-O" max height DAB I 'St rein�.le �e`"n 1,•"`H Ne si:. ry at a to siu " 15/w rdl eMeed Ip satyr m ..oh sndu t ,mneane inn. d 1.6' de" d,le tie - GC t" n y Mhm e" pr"d.et apprwd 10-9-21 + 50.0/-LO.O psf B FLU IL614.1 Fiberglass Deegn Pro/ Smooth Pro Jeld-Wen Elco 1/4' dia. to on with min 1.25' embedment at 3" max from corners and 11.5' o.c. max. thereafter in head and jambs. + 50.0 PSF C FLU 251.5 SlidingGlass Door Series 110 SGD PGT 1' nom Type "GSA" 1/4" dia. tapcons w/ min. 1 3/ penetration o bb�� spaced pei� product approval. ontrector %it adhere to min. 2 I/2 edge distances specified in Product approval + 60.0 PSF - Product NNUMBER Model # Manufacturer Attachment Method cation t��eee Design Pressure of Approved Teats MullionsInstall FLU 261.1 1" x 2 3/4" x .316" PGT per fastener type and spacings shown in Table IA and IB in product approval on sheet 65 or 22. + 58.0 PSF Roof FLU 11651.12 5V Crimp Metal Roofing Gulf Coast Su I in y and manufacturing 2i ga. 5v crimp metal roofing attached to pN}wood deck using #9 x 1.5" wooQ sans with self sisal washer at 12" o.c. max over ASTM D ( e 2) 30 lb Pelt unde� ment installed with min. 4's� laps and 6" end WP ag tip lope fastened with corrosion resistant tin ceps and with 1.25' ring shank nails ?paced L• o.c. at all I and two staggered rows 12 a.c. in field. Attach deck to trunee using attachment detail an roof plan - 108.5 PSF Siding Stucco on Block Soffit FLU 12198.3 Model T4 12" vented Vinyl Soffit Kaycan Install using 2' x 2" battens at V o.c. screwed to soffit framing using #8 x 3' wood screws at each truss. Install soffit to battens using 0.12" cha. x 1.5" Iona ring shlink nails with 3/8' cka, head - +55.0/-35.0 PSF Hurricane Panels I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record 2" x 4" top plate it ' 1/2" drywall ceiling on truss bottom cord JI/2" drywall on 2" x 4" studs at 14" o.c. base -board - 11 11 i 2" x 4" P.T. bottom plate 4" concrete slab with fibermesh OR 4'4" #10/10 WWM on 6 mil Visqueen over clean compacted termite treated fill Interior Non -Bearing Partition nts Braden It Braden AIA, FA Architects -Planners 41� S.E. Coconut Avenue Wynlie Bwlding Corp. THE STERLING Tel : (112) 281-8258 BFax S anish Lakes S . Lucie County Florida : (112) 281-8283 E-mail: bradenala0comcast.net q+,,,,r+ r`I staaac itAAt "nnnno.') Ia" .H. 5/8" thick x 8"w cut coral finished stucco bands Finish Columns with 5/8" thick cut coral finished stucco bands ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP. AND WiLL CONTINUE FOR ONE YEAR FROM THAT DATE PERMITTING INFORMATION (FORM 100) Florida Building Code Residential: Lth Edition and ASCE 1-10 for Wind Loading Building Design is: Enclosed Risk Categorg: It Wind Velocity: 145 mph ultimate Mean Roof Height• II'-O' Roof Pitch: 4:12 Internal Pressure oe icient: ±O-Is Subjectability to damage from: Weathering: Negligible Termites: Veru Heavu Width of Roof End Zone: 3'-4" Wind Speed: ILS mph ultimate Wind Exposure Classification: C 108 sly 1.21 x O.L = O.126 Adjustment factor for Exposure Height: ASD design Load Combination: ASCE 1-10 Section 2.4 DL+LL: DL+O.LWL., O.6DL+O.LWL Components E Cladding Wind Pressure (NET) Roof Zone: I. +20,G/-32.6 psf Roof Zone: 2. +20.4/-51.0 psf Roof Zone: 3. +20.6/-84.0 psf Components E Cladding Wall End Zone Width: 3'-4" Components E Cladding Wind Pressure (NET) Wall Zone: 4. +35.8/-38.1 psf 0 = Roof Zone I Wall Zone: 5. +35.8/-41.8 psf Walls Zone 4 Components d Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3Pat Shear Walls Considered for Structure? Yes Continuous Load Path Provided? ® = Roos Zone 2 es Wells Zone 5 Are Components an Cladding Details Provided? Yes END ZONE Minimum Soil Bearing Pressure: 2,500 par, Presumptive: X B9 Test: psi = Corner Zones SEE PRODUCT APPROVAL FOR iM ACT PROTECTION FOR O E INGS Roof Zone 3 ROOF LIVE LOAD: 51 psf ROOF DEAD LOAD: 10 psf FLOOR LIVE LOAD: -115- sf FLOOR DEAD LOAD: 10 psf JOB ADDRESS: 3Q) MODEL: GARAGE LEFT Date Drawn 9-9-19 Drawn by: C.C.U. Checked by: D.R.B. evisions : F COPY IOR CODE COMPLIANCE Sheet Comm # 1(0-300 B OF 5 FLOOR FLAN CRASH POST DETAIL TYPICAL NOTES: SCALE 1/4" = 1'-0" I. Contractor to verify ALL notes and dimensions prior to ste high by 4" diameter steel crash post. Floor proceeding with work. Flange with 4 - 3/8" 2. Contractor to STRICTLY enforce ALL OSHA Requirements. $la ai3/8 bolts 1nto kal steel plate) 3. ALL Lumber to be used as Beam, Rafters, etc... to have b a minimum 1,400 F.S.I. fiber stress. 4. No dissimilar metals to touch. 2" 2" 5. ALL Concrete used for slabs shall be min. 2,500 PSI concrete. " %' ALL Concrete used for vertical filled cells, cont. tie beams etc.. to m shall be 3,000 P.S.I. concrete and/or 4,000 P.S.i. grout mix a° 2 y" b. Drywall at ceilings shall be leveled and attached to bottom chord 4" of trusses with screws per FBC m I .4.3.5. 0 2 " 1. ALL wood in contact with concrete shall be pressure treated. 8. ALL wall dimensions are nominal and not finished wall or stud dimensions. 9. ALL plumbing fixtures to be low flow. 10. Contractor to Provide Drain at water heater in accordance with the current edition of the Florida Plumbing Code. 11. Contractor to Provide a 2'-8" wide door at one bathroom for V 21 4 „ handicap accessibility requirements. 12. Lowest finished floor to be set by Governing Building Department ` surveyor to set in field. 13. Separation between residence and garage shall be per FBC R302.6 14. Door between garage and residence shall be 1-3/4"t 20 min. rated door WEH• = Water Heater 15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 per FBC R302.9.1 16. Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per FBC R302.9.2 11. All exposed attic insulation materials installed on attic floors shall have a critical radiant I" x L" P.T. Buck nailed to flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation block with case hardened nails materials exposed on the underside of the roof deck or on the attic walls shall comply prior to door attachment with F_B.C. R316 - see permit info box of code edition 18. Gyypsum board material shall conform to ASTM C36, C19, C415, C514, C630, C931 1=r C9b0, C1002, C104TC11-11, CI118, C1218, C1395, or C1396 and shall be installed according to the following: (FBC R-102.3.5) Dr wall Thickness Location Orientation Framing Member Max. s ecin of fasteners Nod sizing options for drgwell into Spacing Maximum installation of wood framing members Nails Screws 2" x min. thickness Ceding Perpendicular 24" 12" 13ga 1 3/8" long with 19/64" head 0.098" diameter x 1 1/4" long /2 annular -ringed or 5d cooler nail 0.080" dia. x 1 5/8" Ion with g Watts Either 141.8" " IL Direction 15/64" head OR Ggpsum board nail 0.086" dia. x 1 5/8" with 9/32" head. Ceiling Perpendicular 24" 1" 12" 13ga 1 5/8" long with 19/64" head 0.098" diameter x 1 3/8" long annular -ringed or 6d cooler nail OR 0.092" dia. xx 11/8" long with Walls Either IL" Direction 1/4" head OR Gypsum board nail 0-0915" dia. x 11/B with 19/64" head. Install SGD thru buck into block with 3/I4" tap -con with 1 1/2" penetration at 0 o_c_ max. from each corner and 20." o.c. max thereafter at head per product approval Use 3/I4" tap -con with 1 1/2" penetration at L" o.c. max. from each corner and 20" o.c. max thereafter at sill per product apprc 19. ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.b, A108.1, A118.1, A118.3, A134.1 and A13-1.1 20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM C1288, C1325, OR CII-18 and installed I.A.W. manufacturers recommendations shall be used as backer for the wall the in tub areas and wall panels in shower areas. 21. Insulation including facings such as retarders or vapor permeable members installed Within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics shall have a flame spread index not to exceed 25 with an accompanyingg smoke developed index not to exceed 450 when tested in accordance with ,4STM E 84. Insulation shall comply with F.B.C. R316. Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12 2L ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5" wood screws with self sealing washer at 12" o.c. max spacing over ASTM D (type 2) 30 lb felt underlagment installed with min. 4' side laps and L" end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails spaced L" o.c. at all laps and two staggered rows 12" o.c. in field. Attach deck to trusses using attachment detail on this sheet \ Simpson HETA 20 or equal hurricane anchor at each trues with (10) IOd x 1 1/2" nails ( 24" o.c.) supporting Max. 18101be. uplift Aluminum Drip -- Edge t Fascia 2" x L" Sub -Fascia Kaycan full o vent vmg using 1/8" dra shank x I rooting nails with 3/8" product approval - see 5/8" thick light textured stucco on typical concrete block construction #5 bar vert. w/ 30" overlap --- at each filled cell Grade 12 4� PRE-ENGINEERED TRUSSES at 24"o.c. TYPICAL (shop drawings by manufacturer) \R-30 blown fiberglass in bottom chord of trusses I/2" drywall with smooth finish Two rows of beam block filled with concrete and (U #5 bar cont. in each row. Substitute ed recast lintel filled with concrete and (1) #5 tar coot. for bottom row over openings ul 1/2" drywall over I" x furringg strips a{ IL" o.c. with R4.1 frFal insulation on typical 8" Block walla All drywall to be installed per FBC R102.3.1 T and shall meet all pertaining ASTM codes. ao Mortar to be Type "M" onlg proportioned per FBC R601.1 and Mortar Jonts shall comply with FBC R601.2.1. Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...) Fill cell with concrete and (U #5 bar vert. (typical). Max. spacing shall not exceed Wood 48" unless otherwise noted Base see foundation plan notes for spacing at openings 4" concrete slab with fibermesh OR L"xL" #10/10 WWM on L mr1 Visqueen over / clean compacted termite treated fill i' i' I \ 14" x 14" Concrete footing 14" with (2) #5 bars cone. and #5 T Y P I C A L SECTION transverse bars at 48" o.c. Scale , 1/2" = I'-0" Masonry Beam Slldlna Door At Masonry Wall N.T.S. Head fixed door sliding door 1 1/2" Sill Detall NTS AREA CALCULATIONS Living A/C = 1,414 sq. ft. Front Porch = 153 sq. ft. Rear Porch = 114 sq. ft. Garage = 321 sq. ft. Total Under Roof= 2,124 sq. ft. Total Cubic Ft = 11,192 2" VTR JAL I I I 21' VTR Master r�� JIL Bath I I�2'. i 2• LrI Lay. i q" I 2• VTR W.C. JIL S. I I I slur-. Kit. emk I I Kitchen a• I I Lev...l 3' W.C. Bath #23" .O. T. o Septic PLUMBING RISER I" x 6" P.T. Buck nailed to block with case hardened nails a prior to door attachment Masonry Wall al Flooring Install SGD thru buck into block with 3/I6" tap -con with 1 1/2" penetration at L" o.c. max. from each corner and 20." o_c. max thereafter at Jambs per product approval IamF, Window Schedule Mark Size Rough Open. Window Description PRESSURE ZONE I. 4'-5%a"x 5'-3%" 54%a"x 0%4" Single Hung ZONE 4 2, 4'-2ke"x 5'-3%a" '75" x 43%' Single Hung ZONE 4 3. 2'-2" x 3'-2 1/2" 21k2"x 38%" Single Hung ZONE 4 4. '-5%"x 4'-2%" 1 54/e"x 5'lv, single Hung ZONE 4 ALL Windows to be aluminum windows w/ tint and mullions per elevations. ALL windows t0 withstand pressures in permit info box on sheet I ALL windows in bathrooms to be tempered All rough opening dimensions to be verified by contractor with manufacturers specs prior t0 construction Door Schedule Mark Size Rough Opening Door Description PRESSURE ZONE A T-O" X T-O" 108" x 84" Overhead Garage Door ZONE 4 B 3'-00 X C-8" 41 %4"x 83%" Fiberglass Panel - Inswing ZONE 4 C V-O" X C-8" 14" x el %2" d °" Sliding Glass Door ZONE 4 D 2'-O" X 4'-8" Solid Core - Wood - L-Panel -Bi-Fold Finished 24" x 81 i2" E 2'-L" X C-8" Solid Core - Wood - L-Panel F 5'-0" X C-8" Solid Core - Wood - L-Panel - Bi-Fold G 2'-8" x C-8" x 1 %4' Solid Core Wood, Steel, or Masonite Door H 2'-8" X L'-8" Solid Core - Wood - L-Panel J 2'-V X C-8" Solid Core - Wood - 4-Panel - Bi-Fold K 2'-e" X C-8" Solid Core - Wood - I. -Panel - Bi-Fold L 1'-6" X C-8" BI-FOLD ALL Exterior doors to withstand pressures stated In permit info box on sheet #i GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #1 All rough opening dimensions to be verified bg contractor with manufacturer s specs prior to construction 10'-01, 12" 10'-O" 12" NOT INCLUDED Opt0R*Fn&P&% O �0 00�o �o 67. o o ° (V - o ° EGRESS 12" x 12" Concrete column E block filled with concrete and (2) #1 bars vert. tied Into lintels above Covered Porch Provide screen infill below CD " c E MASTER 1 1i NOW BEDROOM 1 ° „ 8'-O" to 9 -A.F.F, .F.F. m n 8'-O" A.F.F. Vaulted Ceiling in CD Flat Ceding GRET if o ROOM I O O � E I E Rod t half 1 FIB in Vanity to e N 1 r' 34 %2„hig 1 :r co 1 $ 2" x L" knee -wall 8'-O to 9'-8" A.F.F. N LOJ r O I O[ below counter top mv faulted Ceiling CLOSET I DINING, 19• - - - -� ROOM CA®INIE Rod t Shelf 8„ sae Fir E ® e � ix 1 Vanity to be O F- ° O ° 1 34 Y2"high O1 (4111) 9Y4„ 13'-03/4,, 0 ir in ° High Wall KITCHEN 3'-e° F I o J in Veni Dryer �D through wall O L - - .-.I-L/;2" - - A.F.F. t�ver-hang d- Flat Ceiling o ° B. v Upper cabinets to D extend over Ref. 3'-O"4" l0'-2" O ri 2" filler--2,1 N I E 4'-01, , '' " BATH _ O .sing Rod t Shelf O O A/C o O ��,\\ „ R-II Bat natation W.H. I U)) N ® q Steel Ballard -1 1 Sae detad on this s ae L F O Provide auto 22" x 54° � 24 N closer Attic Access E ° I with light I Q L - - - - - J 22" - 8'-O" A.F.F. Flat Ceding 150 Amp Sc Meter P nel o m f SECOND°LIL PG ^ /_ GEN GRf-t�-"iE E BEDROOM ESSY E O -4" A.F.F. EEI I MT1 EE E (] Flat Cedingif N - F- O O r-----------------i EGRESS E `r Block wall in ° I garage to be I ° struck block I T O E I I O O O T I I - COVERED a I I 12" x 12" concrete column block filled PORCH with concrete and (2) #1 bare vert. tied � p into lintels abo a in I I ° ° o o 0 0 0 °° p ry - lf Oo Is 9'-O" 2'-8" 2'-8" 5'-2"all 15'-lo" Install windows thru buck into block with 3/I4" tap -con with 1 1/2" penetration at L" o.c. max. From each corner and 20." o.c. max thereafter at jambe and 20" o.c. max. Exterior face at head and sill per product approval of wall -1 / \ Buck to be I" x 4" PT I"x4" P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT lock with case hardened nails ON ALL JAMB, HEADER, AND D e t a l l at Windows prior to window attachment SILL BLOCK PRIOR TO BUCK INSTALLATION NTS Exterior face Attach buck to block wall with 1/4" die. Elco cone screws with min. 1 1/4" penetration at 12" o.c. max and 4" max from each corner thru 2" x V PT Buck Uetail at Uaor crews thru jamb into buck tge and 15" o.c. max and prior to door attachment NTS ao V_ STRUCTURAL NOTES" I. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL 8. SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN PROPER ENGINEERING DATA FOR DESIGN. 2. ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS 9• DESIGN LOADS ARE AS FOLLOWS: ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI ROOF (DL+LL) = 41 PSF WIND VELOCITY = PER PERMIT INFO BOX ON SHEET 41 BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS EXPOSURE ="C" 3• POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS, NO SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION. 10, ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-16, E 4 GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10 A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL. WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL 11• ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR (MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE. MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH. FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS, SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE. 5. LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS BEFORE FILL iS BROUGHT IN. FILL MATERIAL SHALL CONSIST OF CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL 12• MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE FOOTING: 3" STRUCTURAL FILL IN LOOSE LAYERS OF 12" IN THICKNESS AND BEAMS: 1-1/2" COMPACT EACH LIFT TO AT LEAST 95% OF ITS MODIFIED DRY PROCTOR VALUE. 13. LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS. 6• GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND 14. USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1400 PSI DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE ATTENTION OF THE ARCHITECT. 15. ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000 PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE. �• GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR 16. ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING. f0uAD�T10N FLAN I. Any changes to plans must be submitted to the architect for approval before proceeding with construction. 2. Contractor shall be responsible for verification of all notation and dimensions before starting construction. 3. Soil conditions assumed to be 2500 psf. Should any other conditions be encountered, the architect shall be notified in writing for revision -f. Verify all recess thickness at showers, tile, etc.... 5. Contractor to provide filled cell with concrete and 1 1*5 bar vert. at 48" o.c. max. Provide (1) filled cell on each side of openings upp to 5'-II" wide. Provide (2) filled cells on each side of openings from 6'-O" to 9'-I1" and Provide (3) filled cells on each side of openings from 10'—O" and up Contractor to see plans for any other condition used. Foundation walls shall have filled cells at 24" o.c. unless otherwise noted (see section) 6. Contractor to provide for Form Board Survey - Form Board Survey to be provided to Truss Company prior to truss construction 1. Contractor to provide for soil test prior to construction and provide a copy of soil test to architect for review prior to construction 8. ALL Reinforcing steel shall be grade 60, meeting ASTM A-16 and A-35 specifications. ALL Anchors to be A-301 steel. 9. Provide a minimum of 3" concrete protection at footings and 1-1/2" concrete protection at beams for ALL reinforcing bars. #5 bar vert. w/ Thicken edge to 8"x8" 30" overlap SEE TYPICAL with concrete and at each filled cellSECTIONS one 3*5 bar continuous WIE_ II I. E TYPICAL F( 4" concrete slab with fibermesh OR VxV #10/10 WWM on 10 mil Visqueen over clean compacted termite treated fill Hill 14"w x 14"d concrete monolithic footing with (2) #5 bars cons. 14 "' ING DETAIL J SCALE 1/2" = 1`0" 4" concrete slab with fibermesh OR 6 x6 410/10 WWM on 10 mil Visqueen over clean compacted termite treated fill #5 bar cont. Step per a foundation plan 11 (2) #5 bars cont. bottom steel DETAIL AT GARAGE STEPDOWN SCALE 1/2" = 1'-0" 12" x 12" concrete column block filled with concrete and (2) #1 bars vert. tied into lintels above Top of footer 16" below finished floor Verify house slab height in field 30"x30"xl6" concrete column footing with (4) 45 bars each way ti-ir_1s�rr� SCALE: 1/4" = 1'-0" Termite Protection for New Construction. Soil treatment used for subterranean termite prevention inside the foundation perimeter shall be done after all excavation, backfilling and compaction is complete. If soil area is disturbed after initial chemical soil treatment area shall be re -treated with a chemical soil treatment including spaces boxed or framed. Treatment must be in accordance With the rules and laws established by the Florida Department of Agriculture and consumer services. Protective sleeves around metallic piping penetrating concrete slab on grade floors shall not be of cellulose containing materials and shall receive application of termicide in annular space between sleeve and pipe. 4" concrete slab with fibermesh OR 6"x6" 410/10 WWM on Io mil Visqueen over clean compacted termite treated fill PORCH SLAB EDGE DETAIL SCALE 1/2" = 1'-0" #5 bar vert. w/ 30" overlap at each filled cell Adjust curb height based on gar. floor slope. 45 bar in curb \ 4" concrete slab with fibermesh OR 6 x6 #10/10 WWM on IO mil Visqueen over clean compacted termite treated fill O'-O" �`r`rrri�iT -III - —II 14" w x 14"d concrete monolithic footing with (2) #5 bars cant. 14" ARAGE CURB DETAIL SCALE 1/2" = 1'-0" 2" x 6" PT wood secured with \ 3/8"dia. x 6" anchor bolt at 18" o.c. overhead door track secured to wood jamb per manufacturer's product approval Garage Door Jamb Detail GARAGE DOOR TO WITHSTAND PRESSURES STATED NTS IN PERMIT INFO BOX ON SHEET #I. SEE PRODUCT APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL. Filled Cell Masonry Column With One #5 From Footing To Tie Beam Conc. Fill To Be 3000 PSI See Floor Plan For Location Single Filled Cell Column NTS Filled Cell Masonry Column With One #5 From Footing To Beam Each. Conc. Fill To Be 3000 PSI See Floor Plan For Location Double Filled Cell Column NTS Braden t Braden AIA, F Architects - Planners 411 S.E. Coconut Avenue JB Tel (112) 281-8258 Fax (112) 281-8283 E-mail: bradenaiascomcast.net Stuart. FL S4996 #AAC000032 I 1--y I ° el ; 10p . PA`tiO/SLAB I® cL --- -r ° OrLi ----------)O I I I I I Rear Patio/Slab to be poured separate W from the house slab. {L �l ° 24" m O Thicken footing to I FI 24% x 14"d x 24"L `n I under filled cells r I under girder bearing. — I° �C ° 2 ° ° Rear Patio%Slab to-----------------� be flush with bottom of sliding door recess. FI Slope 1/2" li I CD I 11 I II I II °I I I H.B_ VanitId'34Y2yto be high 4" concrete slab with fibermesh OR 1 CII� 6"x6" 410/10 WWM on 6 mil Visqueen over °J) clean compacted termite treated fill I I FI I °I I �I V 11 °I I I I FI old 4'-0" i ❑ � o � -------- HL!J A/C Lai #I 1 4"0 Steel Ballard I 1 filled w/ Concrete I�—> 1 I o"` TJ I ' L E 0-10 I I FI 1 1 s E+' I I F1 I I., E a I L— — i1 -i W lJ r r F- -i 1 .N 3 W 1 \ \0, 1 0 a 0 1 UO � F5 1 T T T T T O W � I � A- I 0 W T-2" L Recess for --0 F r l F rGarage Door �, ---- I °--- — — ---- kdl 12" x 12" concrete column block fdle with concrete and (2) #I bars vert. ti into lintels above Winne Building Corp. THE STERLING Spanish Lakes St. Lucie Countg Florida o o I 6D H.B. FOOTING SCHEDULE Mark size Description FI 14"W x 14"10 MONOLITHIC FOOTING WITH 2 95 BARS CONTINUOUS F 12"W X 1211D MONOLITHIC FOOTING WITH (2) #5 BARS CONTINUOUS F 30" x 30" x I6"D COLUMN FOOTING WITH (4) #5 BARS EACH WAY F 8"W x 8"D THICKEN SLAB EDGE WITH 1 #5 BAR CONTINUOUS FS 141111 With x 14"D Curb at Garage MONOLITHIC FOOTING WITH 2 #5 BARS CONTINUOUS - CURB a O'-O" Date Drawn Revisions Sheet Comm # 9-9-19 GARAGE Drawn bg: LEFT C.C.U. Checked by: B D.R-B- OF 5 Provide #5 bars with min. 48 bar diameters overlap into beam. Tic Pilled call steel into continuous beam block steel. t� Provide #5 bar set in pre -cast lintel into beam where length of the opening calls for it. ROOF SHEETING ATTACHMENT DETAIL I. Minimum Nail Size = 8d ring shank (min. 2.5" long) 2. Minimum Screw Size = 48 x 2" 3. Minimum Sheathing Thickness 19/32" CDX Plywood 4. Use nails or screws band on presspre for roof stated in permit info box on t ese plans for zone 3 Ke Area Edge Field Fastener Pressure Zane 1 6" 8d ring shank 45 psf Zone 2 4" 6" 8d ring shank 16 psf Zone 3 4" 4" 8d ring shank 84 psf ** Zone 3a 1 6" 6" #8 wood screw 112.5 psf ** Use nails or s4rews based on pres§ure for roof stated in permit info box on these plans for zone 3 Concrete / Lintel Column Vei , rify with Plan �� 12"x 12" I Column Block `Bt1 Rebar to Lintel Rebar 48 Bar Dia. Min. Overlap Attachment NTS Provide Cast -Crete SUB-OB/OT precast lintel set m mortar Min. 8" Bearing a PT Buck ad per iamb into filled a 4" Pre -cast Sill X Filled Call Provide #5 bare with min. 48 bar diameters overlap in Filled cell. Tie filled cell steel into continuous factor steel. Concrate Footing lase looter schedule for exact sizes) DETAIL AT WINDOW OPENING IN CBS WALL Scale: 1/2" = 1'-0" 1/8" thick light textured stucco installed per ASTM C 924 over ASTM D type 2 paper backed wire lath nailed to substrate through one layer of ASTM D Tgpe 2 felt paper using Bid nails. Substrate to be 19/32" CDX Plgwood nailed at b" o.c. in field III and edges with Irind shank nails into studs. SINGLE PLY REAR GIRDER TRUSS Nail 2" x 4" blocking to vert. leg of truss with IOd x 1.5 nails at 4" o.c. Install Simpson MGT into wall using 5/8' dia. threaded rod set min. 12" into wet beam and (22) IOd nails into truss 3LOCKING DETAIL )ER STRAPPING TER BEARING POINT Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11661.12 26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5" wood screws with self scaling washer at 12" o.c. max spacing over ASTM D (type 2) 30 lb felt uniderlagment installed with min. 4 side laps and 4" end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails spaced 6" o.c. at all laps and two etagggered rows 12" c.c. In field. Attach deck to trusses using attachment dotal on this sheet LINTEL SCHEDULE Mark Window or Do Unit Width Lintel Size Cast -Crete Specification Rows of "H" Block Above a " Bottom Steel Size Top Steel Size Max. Gravite Load (PLP) Max. Upbft Load (PLP) May- Lateral Load (PLP) L22 7-2" V-G" BPS-OB/IT 1 #5 3049 15119 1024 L31 2'-L` 2'-8' 3'-1" 4'-0' 8F8-OBAT 1 #5 25LI 1343 1L3 L45 4'-5" S'-10` 8P8-OB/IT 1 #5 1105 909 939 LSO S'-ON L'-V 8F8-OB/IT 1 #5 1238 835 121 LLO L'-8" T-0 8P8-OB/IT 1 #5 1011 121 534 LBO 8'-0" 9'-4` BP8-IB/2T 1 #5 2 #5 152 S91 512 L90 9'-08 10'-L" 8F8-I13/2T 1 #S 2 #5 643 $30 401 L90B 9'-O" 10'-6" BFIL-I15/2T ONE 1 #5 2 #5 1533 1183 401 1_I00 10'-O" II'-4` 8P8-IB/2T 1 #5 2 as 592 494 452 LIOOBI IO'-O` II'-4" 9FI4-IB/2T ONE 1 85 2 #5 13114 1028 452 L120 17-0" 13'-'f" 8P8-IB/2T 1 #5 2 #5 411 428 324 LI20B 12'-O` 13'-4" BPIL-IB/2T ONE 1 45 2 #5 1015 110 324 LI40 14'-O` 15'-4" 812I6-6/2T ONE I #5 2 #5 1250 1.09 1 259 LILO IL'-O` IT-4" 8F8-IB/2T 1 #5 2 #5 300 192 144 LILOB IL'-O` IT-4" arlL-I15/2T ONE I #S 2 #5 950 500 M4 - ALL LINTELS SHALL BE MADE BY CAST-CRETE. - LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE - REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ. REQUIREMENTS - LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED. Simpson HETA 20 or equal hurricane anchor at each truss with (10) IOd x 1 1/2" nails — ( 24" o.c.) supporting Max. IBIOIbs. uplift Aluminum Drip _ Edge i Fascia 12" 2" x L" S Kagcan full o vent vinyl eofHt metalled using 1/8" dia shank x 1.5' long gaiv. roofing nail@ with 3/8' die. head per product approval - see chart sheet #1 12' x 12' concrete column block filled with concrete and (2) #1 bars vert. tied into lintels above thicken edge to 8"x8" with concrete and one #5 bar continuous BEYOND Top of Tooter IL" below finished floor 12 4 attached to ht framing with no no Ion than (- horizontal wood into vertical w Aluminum Drip - Edge E Fascia Flash and Counter flash Nail ledger to gable end truss with (2) 10d Is at each web on 3/6' hi -rib lath ntai and vertical we it stables to brovidd 3/4" penetration member* 5/8" thick light textured stucco on typical concrete block construction Varies - see plan #5 bar vert. w/ 30" overlap at each filled cell Rear Patio/Slab to be flush with bottom of sliding door recess. 3 Tuwca) Brace Gable end with 2" x 4" SYP #2 eft back nailed to bottom of top chords using (2) IOd nails at each truss RE -ENGINEERED WOOD TRUSSES 9 24"o.c. TYPICAL ( shop drawings bg manufacturer ) w N � 4 X s O� rn (Y S to ZL d to v E C = U C4 sy w Elsic Brace Gable and with 2" x 4" SYP #2 min. aft back nailed to bottoms of top chords using (2) IOd nails at each truss dR-30 blown fiberglass in bottom chord of trusses O a I in -I/2" drywall with smooth finish Two rows of beam block filled with concrete .and (U #5 bar Cont. in each row. Substitute u precast lintel filled with concrete and (1) #5 bar cont. for bottom row over openings W 1/2" drgwall over I" x furringg PI strips at 14" o.c. with R4.1 -foil -insulation on typical 8" Block walls All drywall to be installed per FBC R102.3.1 and shall meet all pertaining ASTM codes. Mortar to be Type "M" on proportioned per FBC R601.1 and Mortar points shall damply with FBC i2601.2.1. Provide Du -Rock at all wet areas (ex. showers. tubs etc...) FIII call with concrete and (D #5 bar veil. (typical). v v -Max. spacing shall not exceed Strap truss to wall using Simpson MGT with Simpson HETA 20 5/8' dia. threaded rod with min 12" embedment hurricane anchor at each truss into beam (22) IOd truss leg either wet set or in epoxy with nails into truss. Add blocking to per detail on this sheet ( 2,4" O.C.) HETA 20 1810 supporting Max. lbs. uplift IVA WAS I WAN WINVAWEAr MAIN WIAWA Gulf Coast-SuriDlu and MFG 5v Crimp Met I roofing P Avid W PEA 'EM"I MEAN,- On MON Ell M: rim III C I I I I FLAN ------------- HETA 20 W L U) L 0�� LU E W LU u� LU ow Z� Z LLI <v I W R � o IZ d) 0 LLI Woad Baca 48" unless otherwise noted see Foundation plan notes for — OVERHANGS AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET spacing at openings 4" concrete slab with fibermesh OR — ROOF PITCH AT 4:12 UNLESS OTHERWISE NOTED ON THIS SHEET L"xt." #10/10 WWM clean compacted on b mil Visqueen over termite treated fill — TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER — ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE •�` ARCHITECT FOR APPROVAL IN WRITING PRIOR TO STARTING CONSTRUCTION. =�I II—IIII—IIII—III =(III=IIII=IIII= — ALL TRUSS TO TRUSS CONNECTIONS BY III IIII IIII— TRUSS MANUFACTURER =III =IIII Ilia- ,.�111- F1 — ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR 14" TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION Section at Front F arch — CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE srAIP . 1/7' = I'-n" FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO TRUSS CONSTRUCTION -2-19 PANEL "A" Poles BR Load Wee Description arc# arc# Description Wee I Load I BR I Ades 1 20 1.2 kw #12 Refrigerator I Range #i 112.0 kw 60 1 2 1 20 1.2 kw #12 Clothes Washer 3 1 20 1.5 kw 812 Kitchen S.A.C. 5 G Dr sr 810 5.0 kw 30 2 1 20 1.5 kw 912 Kitchen S.A.C. 1 a 1 20 #12 Bathroom Recepts 9 10 Air Cond sor #10 5.0 kw 30 2 - 1 20 1.2 kw #12 Dishwasher 11 12 1 20 1.2 kw #12 Microwave Is 14 Air Hand[ #10 5.0 kw 30 2 1 15 - 914 General Lighting 15 16 1 is 814 General Lighting M IS WH #10 5.0 Its 26 2 - 1 15 - #14 General Lighting 19 20 1 15 - 814 General Lighting 21 22 GDO #12 O.al KW 20 1 I 16 914 General Lighting 23 24 Spars Spars 1 25 1 21. 1 Spars spare 21 2a Spare Spam 29 30 Spars PANEL "A" LOAD CALCULATION SHEET Load Description Qt . I Watts Cseneral..Llghting i3. watts, sq,_ft.)......................... ,Small. Appliance, Circuit(s), ,,,,,,,,, ,,,,,,,,, ,,,,,,,,,,,, Ran3e. ......... ......... ......... ......... ........... Refrigerator ... .Microwave..................................................... Dish Washer ......... Clothes_,Washer.............................................. ,Clothes„Dryer................................................ .Water, Heate.r.. ................................................ Csarege.Door,Opener........................................ 1135 3 2 1,500 I 12.000 IF I 1,200 1 1,500 1 1.200 1,200 I 1.200 1200 I 5,000 5.000 I 4,500 4,500 1 810 810 Total Watts 35,615 First 10000 Watts e100% 1 10,000 10,000 Remainder 25,615 e40% 1 O 10,246 Electric Heat or A/C 10,000 91.5% 1 10,000 10,000 Calculated Load Watts 30,244 Voltage 240 Calculated Wattage Divided by Voltage = Total Amps 126.02 Panel Size Required = 150 Amps Electrical S mbol Legend S Single Palo Switch ® Recessed Can Light $$ Double Pole Switch ® Eyeball Recessed ps Push Button Switch Exhaust Fan Duplex Outlet lj Ceiling Mounted Light ==0 Special Receptacle !- Wall Mounted Light eterproo groun cut circuit int Light with Pull Chain (attic) ® Floor Duplex Outlet @ Computer Connection Jack cis Carbon Monoxide Detector Flood Light TQ Thermostat m Electrical Panel ® Central Vac rc:�i Electrical Meter ® Smoke Detector Ceiling fan ® Television Jack ❑ Z Telephone Jack ACoec A/C Disconnect ® I x 4 Florescent Light ® 2 x 4 Florescent Light ® Speaker Hook -Up FB = JUNCTION BOX TO SUPPORT A FAN O = THERMOSTAT LOCATION B/A = BALANCED AIR 1-2-19 149 CFM IOxIOxL MAST R BEDRO M 149 CFm IOAOxb yt .--- ®� 12x1 B/A ---- 9 Cle Opt. PATIO/SLAB Covered Porch 12xI2xIO B/A Cpniter Registers a� 208 CFM or( telling fan 208 CFM L1 IOxIOx IOx1 Ox1 IK71 IK71 Soffit - ATH ° Io i FIELD VERIFY SERVICE LOCATION RESPECIVE TO PANEL LOCATION AND USE APPROPRIATE RISER BELOW (3) #1 THHN Copper 2" PVC Schedule - 40 conduit 200a rated meter can - 2" PVC ( F schedule 80 2" rigid ser A/C disc. LT I ISO MCB PANEL rods ELECTRICAL RISER bonding pant - Contractor shall use AL-CU Landing lugs. - Contractor shall torque lugs I.A.W. manufacturers recommendations which shall be verified prior to construction - Verify AIC/KIC Rating prior to ordering ELECTRIC NOTES: #2/0 AL SER Cable With 41 Grnd 2" PVC Schedule 40 conduit sleeve into attic 200a rated meter can r 2"PVC (FPL schedule 80 2" rigid service A/C disc. 4 I AMP MCB PANEL I l ground rod& bonding pant _ ALTERNATE SERVICE ELECT. RISER NTS - Contractor shall use AL-CU Landing lugs. NTS - Contractor shall torque lugs I.A.W. manufacturers recommendations which shall be verified prior to construction t - Verify AIC/KIC Rating prior to ordering equipment Attie Aeeew I with light J L - - - - - Meter 150 Amp Panel GARAGE I I I I I I I I I I I I I I I I I I I I I 12" DINING ROOM 14 2gx20 �� is r R T1 ��[ ATH j T F I I I tU I ='o 1 I 11 I6" d1 1 14L CFM i L _ IOxLxG � 8�c4�c SECOND BEDROOM 12x12x8 �y B/A COVERED PORCH MECHANICAL LAYOUT scnLe: 114. - r-o.. Exhaust Duct Thru Soffit H.B. Vent_ thru 4" Exhaust SYf it Duct Thru Ulan - - Install owlet under disc. N not shown oA clarity I. Use copper wire only from panel to devices 15. Contractor shall guarantee all materials and workmanship 20. All equipment and panel sizes shall be verified before 2. Provide and wire all required smoke t Carbon free of defects for a period of not less than two years from ordering. The contractor shall provide circuit routings to Monoxide detectors. the date of acceptance or certificate of occupancy, or one suit the job conditions. 3. Contractor to verify location of electrical year from closing sale of house. service and provider. Correction of defects shall be completed without additional 21. Furnish and install all fixtures as called for on the plans 4. ALL bath and kitchen receptacles to be GFCI protected. charge and shall include replacements or repair of any or as selected by others. S. ALL exterior outlets to be WP/GFCI protected. other phase of installation that may have been damaged. 4. Recessed cans to be installed per NFPA requirements. 14. It is not the intent of these plans to show every minor detail 22• All raceways and pipes placed In or through any concrete 1. Tamper resistant AFCI receptacles are required in of construction. The contractor shall furnish and install slab shall be spaced a minimum of three diameters of the ALL rooms. all items For a complete electrical system and provide all largest conduit or pipe From any other service. 8. A/C Return Air Balance Must comp)g w/ FBC RM1402 the requirements necessary for the equipment to be placed in 9. A/C RefrrgergrLt lines that are run thru slabs must be proper working order. 23. All exposed wire below 9'-1" shall be installed in al EMT 10. in F'YG sll ALL ALL A/C Equipment shall comply with energy calculation Il. All work shall be done In accordance with the N.E.C. and shall local conduit. Braden t Braden AIA FA II. All work shall be performed bg a licensed electrical comply with all codes and ordinances, and shall meet all standard requirements of the local electric utility 24. Dryer Vents to be Installed per PEFC RMI502 � 12. system contractor, the completed stem shall be full operative. Contractor For and telephone company. Architects - Planners shall pay all Fees, permits, tes ing, and 411 S.E. Coconut Avenue 13. inspections Including blower testing where required. All work shall be coordinated with other trades to avoid 18. The electrical aystem shall be completely and effectively by latest N.E.C. Tel : (112) 281-8258 interference with the progress of construction. grounded as required the edition of the Fax : (112) 281-8283 14. All required insurance shall be provided for protection 19. All material shall be new and shall bear underwriters' E-mail: bradenala�eomeast.net against the public liability and property damage for the labels where applicable. duration of the work. Stuart. FL 34996 UAAC000032 O v- LECTRICAL PLAN SCALE: 1/4" = 1'-011 Post Light with Attic Venting Calculations EBC 230�.�1 Total Attic Space = 212-4 sq. f t. Venting Ratio 1/150 = 1.416 sq. ft. required Provide A Continuous Vented Soffit Winne Building Corp. THE STERLING Spanish Lakes St. Lucie County Florida Date Drawn : Revisions 9-9-19 GARAGE Drawn by: LEFT C.C.U. Checked by: D.R.S. Photo cell 1 vq) E� H.B. Exhaust Duct ^Thru Soffit Wire For Front Post Light Sheet Comm B OF 5