Loading...
HomeMy WebLinkAboutEnergy CodeCY5(.0 FORM R405-2017 FLORIDA ENERGY' EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation.- Residential Performance.Method Project Name: MNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT. . Street: THE STERLING Permit Office: :ST. LUCIE:COUNTY City, State; Zip:. FT..PIERCE , FL , �--- Owner: %� O �� Permit Number:. Jurisdiction: Design Location: FL, Fort Pierce county: St. Lucie (Florida Climate Zone 2) - 1.. New construction or existing. New (From.Plans) 9. Wall Types (1442.0 'sqft.) Insulation ...Area, 2. Single family or multiple family. Single-family a: Concrete Block - Int Insul, Exterior _ R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family. 1 c. N/A R= :ft2 4. Number of Bedrooms 7 d. N/A R_ , . fti . . 10. Ceiling.Types (1504.0 sqft.) :. Insulation .Area 5; Is this a worst case? Yes a. Under Attic (Vented) R=30.0. 1474.00 ft2 6. Conditioned floor area above grade (ft2) 1474 b. Knee_Wall (Vented) R=19.0 30.00 ftz - Conditioned floor area below,g(ft2)ade (ft0 c. N/A R= ft2 .. 11.• Ducts R .. ft2, 7. Windows(141.3 sgft.) - Description -- Area a. Sup: Attic, Reti Attic,_ AH: Attic 6 175 a. U-'Factor: : Sgl, U=1:04 161.25 ft2 . SHGC: SHGC=0.29 'b. U-Factor: Sgl, U=1.11 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 .SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr . :Efficiency d. U-Factor: N/A =. ft2 a. Electric Heat Pump- 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 14. Hot water. systems . a. Electric Cap:.40 gallons 8. Floor Types (1473.5 sqft.) Insulation Area EF: 0.970 -.a. Slab -On -Grade Edge Insulation R=0.0 1473:50 ft2 b. Conservation features 'b. N/A..- .:R= ft2 None. c. N/A• R= ft2 15. Credits Pstat Total Proposed Modified Loads: 47.97 Glass/Floor Area: 0.096 c PASS ASS Total Baseline Loads: 48.55 hereby certify that the plans and specifications covered by Review of the plans and- -this calculation are in compliance with the Florida Energy. specifications covered by this Code. calculation. indicates compliance with the Florida Energy Code. PREPARED By: DATE. 1-9-20 Before construction is.completed - this building will be inspected for compliance with Section 553.908 O X. * R hereby certify that this building, as designed, is in compliance- , Florida Statutes. , with the. Florida Energy. Code:.-:.. Qd9.w'E . . OWNER/A NT: BUILDING'OFFICIAL: DATE: DATE:AF -. Compliance requires certification by the air handler unit manufacturer that.thE aiAhffl.-nnclos htifielas .1 . certified factory -sealed in accordance with R403:31A. = Compliance requires an Air -Barrier and Insulation Inspection Checklist.in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (1140 REVIEWED FOR,'. CODE. COMPLIANCE: ST.. LUCIE COUNTY BOCC 1/8/2020 4:48 PM EnergyGauge® USA 6:0.02. (Rev. 1) - FlaRes2017. FBC 6th Edition (2017) Compliant Software- Page 1 of 5 INPUT SUMMARY CHEC FORM R405-2017 INPUT SUMMARY CHEC KLIST REPORT PROJECT . Title: WYNNE THE STERLING IMP: :Bedrooms'. 2 Address Type:: Street Address Building Type: , -User: Conditioned Area: 1474 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #'of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle:. 180 Street: THE STERLING: Permit Office: ST. LUCIE COUNTY Cross Ventilation: -' No County: St. Lucie, " Jurisdiction: Whole House Fan: No _" City, State; Zip: _: FT..'PIERCE-; Family Type: Single-family.., FL, .: New/Existing: New (From Plans) Comment:. .. . . .. ... CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2;5 % Winter Summer Degree:Days Moisture Range: FL,: Fort Pierce FL_VERO BEACH MUNI 39 90 70 75 ". 299 62 _ Low • BLO.CKS Number- Name. Area. Volume.. ". .1 Entire House 1474 11792" SP ACES Number. Name: Area Volume Kitchen Occupants: :Bedrooms: InfilID Finished -Cooled . Heated 1 BEDROOM'. 329 2632 No 0 1 1 Yes Yes Yes 2-- WIC : 63 504 No 0 1 No" Yes:Yes " 3 " -M. BATH 56 448 No' 0 1. Yes Yes " . .,Yes. . 4 KITCHEN 192 1536 - . Yes . 0 1 No . Yes Yes' . 5. BATH 45 . 366 .. No . -.-0 1. Yes. Yes. Yes 6 . BEDROOM 2 204: 1632 No. 0- 1 1 " Yes : Yes -.Yes . 7 -ENTRY 55 440 No. 0 1 Yes Yes Yes- - 8 LAUNDRY 42 336 No 0 . 1 Yes Yes Yes 9 GREAT/DINING": _ _ • 488.. 3904 No .. 0 1.: Yes .. Yes .. Yes . . FLOORS # Floor Type Space Perimeter Perimeter R-Value : • Area Joist R-Value Tile " " Wood Carpet- 1 Slab=On-Grade Eiige lnsulatio BEDROOM $2 ft 0 329 ft2 ___: 0 1 . 0 2Slab-On-Grade Edge Insulatio WIC 1 ft 0 63ft2 0 1 •. 0. 3 Slab -On -Grade Edge lnsulatio M. BATH. 8 ft 0 :56 ft' _ 0 1 0 4Slab-On-Grade Edge Insulatio-: KITCHEN 1.ft 0 192 ft2' 0 .: 1 b = 5 Slab-On-Grade,Edge_ Insulatio . - _ , BATH " 5-ft - 01. -45 ft2 , .' _ 0 " "... -1, . 0'' - .6 Slab -On -Grade Edge lnsulatio BEDROOM 2 .32.2 ft 0 2015 ftz .0. T .0 7 Slab -On -Grade Edge Insulatio ENTRY: 7 ft 0 55 ft' 0 1 0 FORM R405-2017 JNPUT. SUMMARY -CHECKLIST REPORT - . FLOORS # Floor Type Space Perimeter Perimeter R-Value - - Area Joist R-Value Tile Wood Carpet 8 Slab'On-Grade Edge:lnsulatio LAUNDRY Aft 0 .42'ft' 1. 0 : 9.SIab-On-Grade Edge Insulatio GREAT/DINING . 46 ft0 - 488 ft' 0 1 0.- ROOF . Roof Gable Roof Rad . Solar•__ SA Emitt Emitt Deck_ Pitch Type : Materials Area : Area Color Barr ' Absor. Tested Tested Insul. : (deg) 1 Gable or -Shed Metal -1553 ft' 246 ft' : -Light N 0.6 'No - 0.9 - No 0 ...18.4• ATTIC. . . _ ' # Type: .. Ventilation: Vent Ratio-(1 in) Area RBS : IRCC: . 1 Full attic Vented • _ 156 . 1474 ftz - . N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac' Truss Type. 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft' 0.1 Wood: 2 :: Under Attic (Vented) WIC .30 Blown:: -63 ft' 0.1 Wood ... 3 UnderAttic�(Venfed) M. BATH 30 Blown 66.ft' 0.1 Wood' 4 Under.Attic (Vented) KITCHEN 30. Blown - 1921' , 0.1 Wood =. .6. Under Attic (Vented) BATH 30.- Blown '45 ft' 0.1 Wood . 6_._ UnderAttic_(Vented) _. __ _ BEDROOM-2_ 30. Blown 2b4ft2. t- Wood 7 Under -Attic (Vented) ENTRY 30 Blown 55:ft' " 0.1 = Wood 8. Under Attic (Vented) -. LAUNDRY 30 Blown .42 ft'. 0.1.. ' Wood. 9. ;. Under Attic (Vented). GREAT/DINING. 30 _ Blown... 488f12'. -0:1 Wood 10:" Knee Wall (Vented). -"BEDROOM 19 Blown" 30 ft'• 0.11 : Wood. . WALLS Adjacent ILT Space Cavity Width Height ing : Solar . Sheathing Fram13 on Below k6rieo . -1 NE=>SW Exterior Concrete Block - I'm InsuBEDROOM. 4.1 10 0.. 8' 0 -80.0 ft2 0 0 UA 0 2. SW=>NE Exterior Concrete Block -: Int lnsuBEDROOM .4.1 28 0 8 0 224.0 ft' 0 0: 0.4. 0 3 NW=>SE Exterior : Concrete Block: = Int IhsuBEDROOM : -4:1 14 . � 0 � 8 : 0 11'2.0 ft' � 0 0 0.4 0 4. SW=>NE.Exterior - . Concrete Block - Int Insul M. BATH .: 4.1 . 8 0 8 .0 64.0 ft' . 0 0 0.4 0, 5 NE=>SW Exterior Concrete Block - Int Insul BATH 4.1 5 - 0 8- 0 40.0 ft' 0 0 .0.4 0 6 NE=>SW Exterior. Concrete Block = Int InsBIEDROOM 2 4.1 16 0 8 0-: 128.0 ftz 0.: 0- ": • 0.4 m 0 7..SE=.>NW.Exterior. Concrete Block's. Int InsGEDROOM 2. 4.1 .10 .0 8 0 :. 80.0 ft' ... .0 0 . :. 0.4 . 0 . . 8 S=>N- Exterior Concrete Block- Int InSEXEDROOM 2' 4.1 4 3 8 -0 34.0 W. 0- -0 0.4 0' 9 SW=>NE Exterior -Concrete Block;. Int InSBIEDROOM 2 4.1 2 0 8 0 16.0 ft' 0 0• 0.4- 0 :10 SE=>NW Exterior - Concrete Block-- Int Insul ENTRY' 4.1 -6 6 8 - 0 : 4&0 ft' 0': : " 0 : 0.4 0 11 SW=>NE Exterior . Concrete Block- Int Insul ENTRY 4:1 1 0 :8 0 8.0 ft' 0 0 0..4' 0 12 SW=>NE Exterior Concrete Block - Int InsuLAUNDRY 4.1. 6 0 8 0 48.0 ft' . 0 .0 0.4 0 13 NE=>SW Exterior Concrete Block = Int InstOREAT/DINI_ -4.1 26 0 • 8 0,_ •208.6 ft' 0 0 0.4 ,. 0 14 NW=>.SE Exterior Concrete Block- Int InsOREAT/DINI 4.1 20. 0 8." 0. 160.0.ft' 0, 0 0.4 .0 FORM R4n5_9n17 INPI IT __R11MMARV CI4FCKI 1ST REPORT WALLS . V. Adjacent Cavity Width Height 'Sheathing Framing :, Solar Space_ Below o 15 N=>S Garage Frame -Wood KITCHEN 11- 24 8 192.0 ft2. 0.23 0.4 0 DOORS # Omt Door Type Space Width Storms U-Value Ft Width In Ft Area 1. SE=>NW , Insulated ENTRY • None .39 3 - 1 6 8. 20.6 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst. Case. / Wall. # Ornt ID • Frame Panes NFRC Overhang U-Factor. SHGC Imp Area Depth Separation : Inf Shade Screening 1 :NW=>SE 3 Metal 2._ SW=>NE.4 Metal 3 SE=>NW 7 Metal :4 NE=>SW13 Metal 5 :NW=>SE14 Metal .Low-E Single _ Low-E Single .Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 1.04 .0.29 N w 32.9 ft2. 1 ft 0 in 1 ft 5 in: - 1.04 0,29 N 6.9 ft2 -1 ft 0 in . 1 ft, 5 in 1.04 0.29 N 24.0 ft2 6 ft 0 in 1 ft 5 in 1.04 0.29 N 37.5 ft2 1 ft 0 in 1 ft 5 in 1.11 0.27 N. Offft2 8 it 0 in . _-1 ft 5 in Drapes/blinds None None None Drapes/blinds Exterior 5 None- . None None Exterior 5 ..GARAGE # Floor Area Ceiling Area Exposed Wall. Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft2 315 ft2 24 ft, 8 ft 11 INFILTRATION .... .. .. .... .. # Scope -Method . SLA CFM 50 ELA EgLA . ACH ACH 50 1 Wholehouse Proposed'ACH(50)- .000356 1375.7 75.53 142.04 .1233 7 HEATING SYSTEM # .System Type Subtype . Speed Efficiency Capacity :Block. - Ducts'-1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sy41 COOLING SYSTEM .. . # System Type Subtype. Subtype Efficiency Capacity Air Flow 'SHR Block Ducts . 1,- Central Unit/ Split Singl . SEER: 15 34.8 kBtu/hr cfm 0.85 - 1 sys#1 - HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation. 1 Electric None Garage : 0.97 40 gal '60.9 gal 120 deg None FORM R405-2017 INPUT SUMMARY: CHECKLIST REPORT SOLAR HOT WATER SYSTEM . FSEC Collector. Storage: Cert # . Company Name - System Model #. Collector Model # . Area. Volume." FEF-• None None ft2 :DUCTS :. -=- Supply Retum.=- - Air'- :CFM 25 . 6FM25: HVAC # - V # . Location R=Value Area Location Area Leakage Type . - Handler - TOT OUT " QN RLF Heat Cool 1. ; Attic . .6 - .175 ft2. _ "Attic :. 65 ft2 _ . Default:Leakage Attic.. :. (Default) (Default). TEMPERATURES .. . Programable'Thermostat: Y . Ceiling Fans: Cooling Jan Fell .Heating ' Jane Feb' Mar Mar �X�.Apr.: Apr Apr.: : �. May May:.. Jun' Jun:. r1jun Jul .: �Xj Jul Aug Aug . X Sep Sep. Oct : Oct �X� Nov: Nov Dec Dec. . N Venting Jan . Feb X Mar = May-' Jul Aug _ Sep Oct - Nov Dec ,' Thermostat Schedule: H_ ERS 2006 Reference Hours . Schedule Type . 1 - 2 3 . .4 5 6 7 8 9'' .; 10 11 12 Cooling (VVD) AM' 78 .• 78 78 78 78- 78....78 : 78 80.' 80'.. ...80 -.80 PM -80 - - 80 - 78 78 78 78 78 78 78 '78 78,' 78 Cooling (WEH) AM -78, , 78 78 -78 78. 78 .78 78 78 -78 . . 78 '78 PM 78 78 78 78 78 : 78 78 78 78: 78 .78 78 Heating (WD)' AM : ' ' 66 -66: " '66:: 66 66 68 : 68 68': 68 = 68 68 68 PM- .68 .. 68 .. .68. 68• • 68• .68• 68 68 68 . ' .. 68.,-- .:66 -. 66. Heating (WEH) AM' 66 66 66 66 66 68 68 . 68' 68 68 68 . 68 PM -68 68- 68 68 . .68 68 68 68. 68 .68 66— -66 MASS, Mass Type' Area . Thickness Furniture Fraction Space. Default(8 Ibs/soft. 0 ft2: Oft . 0.3 - BEDROOM Default(8 lbs/sq.ft: ft? ft. 0.3' WIC Default(8 lbs/sq:ft.:. . .. ft -0.3. . M BATH .. - Default(8lbs/sq.ft. ft' ft 0.3 KITCHEN- ' -Default(8 lbs/sq.ft. ft2 ft 0.3. BATH . Default(8 IWsq:ft.: ft2: ft 0.3 BEDROOM'2 -Default(8 lbs/sq.ft: ft2 ft 0:3 ENTRY Default(8lbs/sq.ft. ft2. ft- 0.3 LAUNDRY Default(8 Ibs/s .ft. ft2 ft .0.3. GREAT/DINING 2017.- AIR: BARRIER AND:INSULATION INSPECTION COMPONENT CRITERIA: - : TABLE:402:4.1:1 AIR BARRIER AND INSULATION: INSPECTION COMPONENT CRITERIA = Project Name:. WYNNE THE STERLING IMPACT - Builder Name: WYNNE DEVELOPMENT Street:. THE'STERLING Permit Office:: ST. LUCIE COUNTY .:City, State, Zip: FT: PIERCE ; FL, Permit Number:: Y U Owner:.. Jurisdiction: Design Location:: FL, Fort Pierce x) COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION -CRITERIA General A continuous air barrier shall be installed in the-building:envelope: Air=permeable insulation shall The exterior thermal envelope contains a, continuous. air barrier. not: be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be.aligned with The insulation in any dropped ceiling/soffit ... the. insulation and an gaps. in the air barrier.shall be sealed. . Y 9 p shall be aligned With the air, barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of -the foundation and sill,plate shall'be sealed.: Cavities within corners -and headers of frame'walls The junction. of the top: plate and the.top of exterior walls shall be.. shall be insulated by completely filling the -cavity . . . .. .... .. sealed._ : .. with -a material having a.thermal resistance'of R-3' Knee walls shall be: sealed. per inch minimum. . Exterior thermal envelope:insulation for framed .: walls shall be installed in substantial contact and continuous alignment with the air barrier: Windows; sk li hts :. Yg The space. between winnow/door jambs and framing,, and P.. 9.... .. and doors - skylights and framing shall be sealed.' .Rim joists-. Rim joists shall include the air barrier: Rim joists shall be insulated. Floors : The air barrier shall be: installed at any exposed edge of : Floor framing: cavity insulation shall be installed to- - ' (including.: •. insulation.. maintain permanent contact With the underside of.-:. . above,garage: subfloor decking, or floor framing cavity insulation: and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from: the. bottom, to the top of all perimeter floor framing., .. .:' .... .. .. . .. .... members: . Crawl space walls ' Exposed earth in rinvented crawl spaces shall be covered with '. Where provided instead of.floor insulation, insulation a Class I vapor retarder with overlapping joints taped. p shall be permanently attached to the crawlspace Shafts,: penetrations Duct shafts, :utility penetrations, and flue shafts opening to - exterior or unconditioned space shall be sealed. - - ' Batts in narrow cavities shall be cut to ft,:or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity . • spaces: Garage separation Air sealing shall be provided between the garage and conditioned'spc as. Recessed. lighting. Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the -building . shall be sealed to the- drywall. thermal envelope shall be air tight and IC rated.. Plumbing and wiring. Batt insulation shall be cut n around neatly to fit wiring and. plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend -behind wiring, Shower/tub, . The air barrier installed at exterior.walls:adjacent to; showers and Exterior walls adjacent to showers'and tubs shall on:exterior wall tubs shall separate ahem from the'showers.and tubs. be insulated. Electrical/ hone box or The air barrier shall: be installed behind electrical. or communication exterior walls boxes•or air -sealed boxes shall be installed. HVAC.register boots HVAC register boots -that penetrate building thermal envelope shall be sealed to:the sub=floor or drywall.' Concealed .... . .... . When required to be sealed, concealed fire sprinklers: shall only be . .... .. .... sprinklers sealed.in a manne-r'thafis recommended_ by the manufacturer. ,; Caulking or other adhesive sealants shall not be used to fill voids -. between fire sprinki cover plates and walls or ce a. 7n addition,: inspection of log 'walls :shall be, in accordance with the provisions:of ICC-400: 1/8/2020 4:49 PM En6rgyGau,ge@ USA 6.0.02 (Rev..1)•- FlaRes2017 FBC 6th Edition'(2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD.. ENERGY PERFORMANCE LEVEL (EPL) DISPL":CARD ESTIMATED ENERGY PERFORMANCE INDEX* =. 99 . The lower. the Energy Performance Index, -the more :efficient the home: 1. New home or, addition 1. -New (From Plans) 12. Ducts, location & insulation level a): Supply ducts R '6.0. :.. 2; Single-family.or multiple -family.:.-. 2: Single-family .... .'.b) Return ducts . R 6:0- - ;c) AHU location Attic 3, No. _of. units (if multiple -family) 3.. 1. 4.: Number of bedrooms • 4: • 2 13: Cooling system:: Capacity :. . a}Split system..- .. SEER 115.0 -- . 5. Is this a worst case? (yes/no) 5: Yes b) Single "package : SEER . c) Ground/water source SEER/COP . 6.. Conditioned floor area (sq. ft.) 6. 1474 d) Room unit/PTAC :.EER . e) Other . 7. Windows, type and area a) U-factor:(weighted average) 7a.' 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b.. 0.284 . 14..Heating system: Capacity 34.8. c) Area.:. 7c. ...141.3 a) Split system heat pump.:. HSPF .. - 8.5 . . 'b)Single package heat'pump HSPF 8. Skylights c) Electric resistance COP' ._a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas.; AFUE b) Solar Heat Gain Coefficient (SHGC) 8b.. -.NA . e) Gas furnace,. LPG AFUE • f) Other 9: Floor type, insulation level: a)•Slab-on=grade (R7value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15.. Water heating system . c) Concrete, raised (R-value) 9c. a) Electric_ resistance EF '0.97 ; „. b) Gas fired,. natural gas EF `. .10.-Wall type.and insulation:.. c).Gas fired,. LPG .:.. EF. .. .. A. Exterior: .: : d) Solar system with tank EF 1. Wood frame (Insulation R-Valu.e) 10A1.1 e) Dedicated heat pump with.tank EF. 2..Masonry:(Insulation.R-value):. 10A2. :4.1 f) Heat.recovery unit:. HeatRec% B.. Adjacent:: .. : g):Other 1. Wood frame (Insulation R-value) 10131. 11-.0 . 2. Masony (Insulation R-value) 10B2. 16.-HVAC-credits claimed (Performance Method), 11.. Ceiling type -and -insulation -level. a) Ceiling fans .. . a) Under attic : 11a. :30.0 b)-Cross ventilation: No b :Sin le assembly :11.b: c Whole house fan - -:No-.-" -'c) Knee Walls/skylight walls 116. 19.0 d) Multizone cooling credit d) Radiant barner-installed. 11d. • No e) Multizone heating.credit f) Programmable;thermostat. Yes .; . *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation; if not DEFAULT.: certify that this home has complied with the Florida Building: Code', Energy Conservation, through the above energy - saving .features. which:wili be installed (or exceeded): in -this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant -features.' Builder Signature: Date: Address of.New.Home:-: THE STERLING. City/FL Zip: : FT.. PIERCE; FL 1 1/8/2020 4:49:01. PM . EnergyGauge®. USA 6.0.04 (Rev.. 1) - FlaRes2017 FBC 6th Edition (2017):Compliant Software Page 1-of 1 ;