HomeMy WebLinkAboutEngineering utting
• FIELD DENSITY .
I� �3 REPORT
Your Proi-A Ourpommitmerit
PROJECT NO. PSL-1316
TO CLIENT Lennar Homes, LLC
Lennar Homes, LLC C.C.
8895 N Military Trl Ste. 101-B REC,FEE r
Palm Beach Gardens, FL
- 33410 •
ATTN: Thomas Leo LL-1 I� �,•.�
St. Lac"sue FL
PROJECT Meadow wood LOCATION Btwn I-95 and Johnson Rd.�
Fort Pierce, FL
REPORT NO. 6 NO.OF DENSITIES 5 TESTED BY M. Updike DATE TESTED Apr 10, 2 017
CONTRACTOR See Supporting Lab,Testing
AREA Proofroll Reports for Detailed;Material
CONSTRUCTION TYPE (0—12") Descriptions
DENSITY LaboratoryMOISTURE DRY DENSITY
LOCATION COMPACTION
NUMBER Soil Identifier FIELD LAB FIELD LAB %
16 Lot 192- Approximate Center Lt Brown Sand 6.6 12.0 108.2 107.5 101
Sl Trace Shell Frags
17 Lot 194- Approximate Center Lt Brown Sand 7.4 12.0 107.0 107.5 100
Sl Trace Shell Frags
18 Lot 195- Approximate Center Lt Brown Sand 6.9 12.0 107.6 107.5 100
Sl Trace Shell Frags
19 Lot 196- Approximate Center Lt Brown Sand 7.9 12.0 107.5 107.5 100
Sl Trace Shell Frags
20 ILO Lot 197- Approximate Center Lt Brown Sand 6.8 12.0 107.2 107.5 100
Sl Trace Shell Frags
FIELD METHOD Nuclear ASTM D6938 98
SP�C:�fItb,GOMF-AC;rjoW .
LABORATORY METHOD Modified Proctor ASTM D1557 4. ion,
1L`; �1'S91N`bIC Ell.,:
.°\.-
COMMENTS �=- . ;•m°� - - : . �.
` '`, ?,�
Page 1 of 1 Apr 10,'2017 ='• ; %`,C'at� l y (_ t:
P Nutting Engineers of Florida,Inc. PER. P.
t1.��C±±�RI Y. .[[yy ,
These test results only represent compaction measured at the location reported to a maximum depth of 12 Inches below the surface tested. IRICh31i>1+1•dps$ly`�.E:#42603
This report does not reflect bearing capacity or deeper soil conditions.
This report shall not be reproduced,except In full or relied upon without prior written approval of Nutting Engineers of Florida,Inc..
t, , ..
Palm Beach(561)736-4900*Broward(954)941-8700*Miami Dade(305)824.0060*Port St.Lucie(772)408-1050
LSH ENGINEERING,Au c.
'470. BOX 933, BOCA RATON, FL 33riZ9
(561) 362-0237 362-7414 (FAX)
April 12, 2017
St. Lucie County Building Dept.
2300 Virginia Ave
Fort Pierce, FL 34982
Re: Lennar, Meadowood
Lot 197
Permit# 1703-0330
I
Plan Reviewer,
The following revisions have been made to the construction documents for the above referenced
location.
1. Removed detail referencing glass block on sheet 6.
y"401 1Ilill
B
` `--`� d � �f
inCerey,.; G�
a c� �
I
APR 14 2011
PERNIFTING
St. Lucie Count;, FL
i
STRUCTURAL ENGINEER,P.E. #33915 - SPECIAL INSPECTOR, S.I. #0290