Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Efficiency
JV Ile Copy; FORM R405-2014 I FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: LH-2500-MW Builder Name: LENNAR HOMES Street: 9501 POINCIANA CT. Permit Office: City,State,Zip: FORT PIERCE,FL., Permit Number: Owner: 2500 MODEL LOT 197 @ MEADOWOOD Jurisdiction: Design Location: FL,Fort Pierce County:: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types 2400.0 sqft.) Insulation - Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 2200.00 ft2 b.Frame-Wood,Adjacent R=11.0 200.00 ftZ 3. Number of units,if multiple family 1 c.N/A R= ftZ 4. Number of Bedrooms 4 d.N/A R= ftZ 5?Is this a worst case? No 10.Ceiling Types (2520.0 sqft.) Insulation Area i a.Under Attic(Vented) R=30.0 2520.00 ftZ 6. Conditioned floor area above grade(ftZ) 2520 b.N/A R= ftZ Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ 11.Ducts R ftZ 7. Windows(343.9 sqft.) Description Area a.Sup:Attic,Ret:STUDY,AH:STUDY 6 300 a. U-Factor: Dbl,U=0.53 324.00 ftZ SHGC: SHGC=0.24 b. U-Factor:. Dbl,U=0.56 19.93 ftZ 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.23 a.Central Unit 46.5 SEER:14.00 c. U-Factor: N/A ftZ SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a.Electric Heat Pump 47.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 6.414 ft. Area Weighted Average SHGC: 0.239 14.Hot water systems 8. Floor Types (2520.0 sqft.) Insulation Area a.Electric Cap:50 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 2520.00 ftZ b. Conservation features b.N/A R= ftZ None c.N/A R= ftZ 15.Credits Pstat Glass/Floor Area: 0.136 Total Proposed Modified Loads: 78.58 PASS Total Baseline Loads: 81.31 I hereby certify that the plans and spec' ications covered by Review of the plans and O�-04E ST`1?� this calculation are in compliance with a Flori a Energy specifications covered by this ti 90 'Code. calculation indicates compliance y ��„ '_= .A _ r with the Florida Energy Code. PREPARED BY: Before construction is completed u�f DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed ' in compliance Florida Statutes. t� with the Florida Energy Code. GOD WE C¢� (OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: i - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. I 4/5/2017 5:51 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 I � FORM R405-2014 PROJECT Title: LH-2500-MW Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2520 Lot# Owner: 2500 MODEL LOT 197 @ ME Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: LENNAR HOMES Rotate Angle: 180 Street: 9501 POINCIANA CT. Permit Office: Cross Ventilation: No County: St.Lucie Jurisdiction: Whole House Fan: No City,State,Zip: FORT PIERCE,I Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site. Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range Y FL,Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 i Low BLOCKS Number Name Area Volume 1 Entire House 2520 25200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 STUDY 180 1800 No 1 4 1 No Yes Yes 2 TIOL MASTER 21 210 No 0 1 No Yes Yes 3 MASTER BATH 132 1320 No 0 1 No Yes Yes 4 WIC EXT MASTER 50 500 No 0 1 No Yes Yes 5 WIC MASTER INT 40 400 No 0 1 No Yes Yes 6 MASTER SUITE 294 2940 No 2 1 No Yes Yes 7 DINING FOYER 270 2700 No 0 1 No Yes Yes 8 GREAT ROOM 324 3240 No 0 1 No Yes Yes 9 PANTRY 24 240 No 0 1 No Yes Yes 10 LAUNDRY 81 810 No . 0 1 No Yes Yes 11 KITCHEN 247 2470 No 0 1 No Yes Yes 12 BREAKFAST 100 1000 No 0 1 No Yes Yes 13 BED 2 180 1800 No 1 1 No Yes Yes 14 BATH 2 55 550 No 0 1 No Yes Yes 15 BED 3 168 1680 No 1 1 No Yes Yes 16 HALL TO BEDS 108 1080 No 0 1 No Yes Yes 17 BED 4 180 1800 No 1 1 No Yes Yes 18 CABANA 66 660 No 0 1 No Yes i Yes i i 4/5/2017 5:51 PM EnergyGaugeB USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 I i . , FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio STUDY 27 ft 180 ft2 0 0 1 i 2 Slab-On-Grade Edge Insulatio TIOL MASTER 1 ft 21 ft2 ____ 1 0 0 i 3 Slab-On-Grade Edge Insulatio MASTER BATH 1 ft 132 ft2 ____ 1 0 0 4 Slab-On-Grade Edge Insulatio WIC EXT MASTE 10 ft 50 ft2 ____ 0 0 1 i 5 Slab-On-Grade Edge Insulatio WIC MASTER IN 1 ft 40 ft2 ____ 0 0 1 6 Slab-On-Grade Edge Insulatio MASTER SUITE 44 ft 294 ft2 ____ 0 0 1 7 Slab-On-Grade Edge Insulatio DINING FOYER 27 ft 270 ft2 ____ 1 0 0 y 8 Slab-On-Grade Edge Insulatio GREAT ROOM 18 ft 324 ft2 ____ 0 0 1 9 Slab-On-Grade Edge Insulatio PANTRY 4.5 ft 24 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulatio LAUNDRY 16 ft 81 ft2 1 0 0 11SIab-On-Grade Edge Insulatio KITCHEN 1 ft 247 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulatio BREAKFAST 20.5 ft 100 ft2 ____ 0 0 1 13SIab-On-Grade Edge Insulatio BED 2 18.5 ft 180 ft2 0 0 1 14SIab-On-Grade Edge Insulatio BATH 2 5.5 ft 55 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulatio BED 3 14 ft 168 ft2 _—_ 0 0 1 16SIab-On-Grade Edge Insulatio HALL TO BEDS 1 ft 108 ft2 0 0 1 17SIab-On-Grade Edge Insulatio BED 4 27 ft 180 ft2 ____ 0 0 1 18SIab-On-Grade Edge Insulatio CABANA. 17 ft 66 ft2 ____ 1 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 2730 ft2 0 ft2 Medium 0.9 No 0.9 No 0 I 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2520 ft2 N_ N i i 4/5/2017 5:51 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) STUDY 30 Blown 180 ft2 0.1 Wood 2 Under Attic(Vented) TIOL MASTER 30 Blown 21 ft2 0.1 Wood 3 Under Attic(Vented) MASTER BATH 30 Blown 132 ft2 0.1 Wood 4 Under Attic(Vented) WIC EXT MASTE 30 Blown 50 ft2 0.1 Wood 5 Under Attic(Vented) WIC MASTER IN 30 Blown 40 ft2 0.1 Wood 6 Under Attic(Vented) MASTER SUITE 30 Blown 294 ft2 0.1 Wood 7 Under Attic(Vented) DINING FOYER 30 Blown 270 ft2 0.1 Wood 8 Under Attic(Vented) GREAT ROOM 30 Blown 324 ft2 0.1 Wood 9 Under Attic(Vented) PANTRY 30 Blown 24 ft2 0.1 Wood I 10 Under Attic(Vented) LAUNDRY 30 Blown 81 ft2 0.1 Wood 11 Under Attic(Vented) KITCHEN 30 Blown 247 ft2 0.1 Wood I r 12 Under Attic(Vented) BREAKFAST 30 Blown 100 ft2 0.1 Wood 13 Under Attic(Vented) BED 2 30 Blown 180 ft2 0.1 Wood 14 Under Attic(Vented) BATH 2 30 Blown 55 ft2 0.1 Wood i 15 Under Attic(Vented) BED 3 30 Blown 168 ft2 0.1 Wood 16 Under Attic(Vented) HALL TO BEDS 30 Blown 108 ft2 0.1 Wood i 17 Under Attic(Vented) BED 4 30 Blown 180 ft2 0.1 Wood 18 Under Attic(Vented) CABANA 30 Blown 66 ft2 0.1 Wood WALLS I Adjacent Space Cavity Width Height Sheathing Framing Solar; Below lipEt In Et In Area R-NIalue Fr;;Ctinn 0 1 SE=>NW Exterior Concrete Block-Int Insul STUDY 4.1 14 0 10 0 140.0 ft2 0 0 0.5 0 2 SW=>NE Exterior Concrete Block-Int Insul STUDY 4.1 12 0 10 0 120.0 ft2 0 0 0.5 j 0 _ 3 SW=>NE Exterior Concrete Block-Int InsfXASTER BA 4.1 11 6 10 0 115.0 ft2 0 0 0.5 0 4 NE=>SW Exterior Concrete Block-Int InsMASTER SUI 4.1 12 0 10 0 120.0 ft2 0 0 0.5 ; 0 5 SW=>NE Exterior Concrete Block-Int InsMASTER SUI 4.1 18 0 10 0 180.0 ft2 0 0 0.5 0 6 NW=>SE Exterior Concrete Block-Int InsMASTER SUI 4.1 14 0 10 0 140.0 ft2 0 0 0.5 0 7 SE=>NW Exterior Concrete Block-Int InsMINING FOY 4.1 18 0 10 0 180.0 ft2 0 0 0.5 0 8 NW=>SE Exterior Concrete Block-Int InsGREAT ROO 4.1 18 0 10 0 180.0 ft2 0 0 0.5 0 i 9 SW=>NE Exterior Concrete Block-Int InsEIREAKFAST 4.1 10 0 10 0 100.0 ft2 0 0 0.5 0 10 NW=>SE Exterior Concrete Block-Int InsBIREAKFAST 4.1 10 6 10 0 105.0 ft2 0 0 0.5 0 11 NE=>SW Exterior Concrete Block-Int Insul BED 2 4.1 11 6 10 0 115.0 ft2 0 0 0.5 0 _12 SE=>NW Exterior Concrete Block-Int Insul BED 2 4.1 7 0 10 0 70.0 ft2 0 0 0.51 0 13 NE=>SW Exterior Concrete Block-Int Insul BATH 2 4.1 5 6 10 0 55.0 ft2 0 0 0.5 0 14 NE=>SW Exterior Concrete Block-Int Insul BED 3 4.1 14 0 10 0 140.0 ft2 0 0 0.5 0 15 NE=>SW Exterior Concrete Block-Int Insul BED 4 4.1 15 0 10 0 150.0 ft2 0 0 0.5; 0 16 NW=>SE Exterior Concrete Block-Int Insul BED 4 4.1 12 0 10 0 120.0 ft2 0 0 0.51 0 17 SW=>NE Exterior Concrete Block-Int Insul CABANA 4.1 11 0 10 0 110.0 ft2 0 0 0.5 0 _18 NW=>SE Exterior Concrete Block-Int Insul CABANA 4.1 6 0 10 0. 60.0 ft2 0 0 0.51 0 19 NE=>SW Garage Frame-Wood STUDY 11 20 10 200.0 ft2 0.23 0.75 0 4/5/2017 5:51 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 I I FORM R405-2014 I i DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In I 1 SE=>NW Wood DINING FOY None .39 3 7 6 8 23.9 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 180 degrees). Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 SE=>NW 1 Metal Double(Tinted) Yes 0.53 0.24 30.0 ft2 2 ft 0 in 1 ft 0 in None j None 2 SW=>NE 3 Metal Double(Tinted) Yes 0.53 0.24 9.0 ft2 2 ft 0 in 1 ft 0 in None None 3 SW=>NE 5 Metal Double(Tinted) Yes 0.53 0.24 10.0 ft2 2 ft 0 in 1 ft 0 in None None 4 NW=>SE 6 Metal Double(Tinted) Yes 0.53 0.24 30.0 ft2 2 ft 0 in 1 ft 0 in None None 5 SE=>NW 7 Metal Double(Tinted) Yes 0.53 0.24 36.0 ft2 8 ft 0 in 1 ft 0 in None None 6 SE=>NW 7 Metal Double(Tinted) Yes 0.53 0.24 12.0 ft2 8 ft 6 in 1 ft 0 in None None 7 NW=>SE 8 Metal Double(Tinted) Yes 0.53 0.24 72.0 ft2 11 ft 6 in 1 ft 0 in None None 8 SW=>NE 9 Metal Double(Tinted) Yes 0.53 0.24 36.0 ft2 17 ft 0 in 1 ft 0 in None None 9 NW=>SE10 Metal Double(Tinted) Yes 0.53 0.24 36.0 ft2 2 ft 0 in 1 ft 0 in None None .10 NE=>SW11 Metal Double(Tinted) Yes 0.53 0.24 15.0 ft2 2 ft 0 in 1 ft 0 in None j None 11 NE=>SW13 Metal Double(Tinted) Yes 0.53 0.24 4.0 ft2 2 ft 0 in 1 ft 0 in None None 12 NE=>SW 14 Metal Double(Tinted) Yes 0.53 0.24 15.0 ft2 2 ft 0 in 1 ft 0 in None None 13 NW=>SE16 Metal Double(Tinted) Yes 0.53 0.24 15.0 ft2 2 ft 0 in 1 ft 0 in None None 14 SW=>NE17 TIM Double(Tinted) Yes 0.56 0.23 19.9 ft2 2 ft 0 in 1 ft 0 in None None 15 NW=>SE18 Metal Double(Tinted) Yes 0.53 0.24 4.0 ft2 2 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 382.8 ft2 382.8 ft2 64 ft 8 ft 1 I INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000318 2100 115.29 216.81 .2319 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 47 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 14 46.5 kBtu/hr 1395 cfm 0.75 1 sys#1 I I i 4/5/2017 5:51 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 i FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 I . DUCTS I —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 300 ft2 STUDY 100 ft2 Default Leakage STUDY (Default) (Default) 1 1 s TEMPERATURES Programable Thermostat:Y [ ]] Ceiling Fans: Heat ng Jan Feb f X]Mar Apr May Jun Lr May rj JunX�Jul Jul rl Aug L Au X�Sep �X�Oct ct �X1 Nov Nov Dec Venting Jan Feb [ Dec X Mar Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 1 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM. 68 68 68 68 68 68 68 68 68 68 66 66 ,i I I I i i 4/5/2017 5:51 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 I I FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 9501 POINCIANA CT., FORT PIERCE, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area a.Concrete Block-Int Insul, Exterior R=4.1 - 2200.00 ft2 2.:Single family or multiple family Single-family b.Frame-Wood,Adjacent R=11.0 200.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft? 4. Number of Bedrooms 4 d.N/A R= ft? i 10.Ceiling Types Insulation Area I 5. Is this a worst case? No a. Under Attic(Vented) R=30.0 2520.00 ft? 6. Conditioned floor area(ft2) 2520 b.N/A R= ft2 7. Windows- Description Area c.N/A R- ft2 a. U-Factor: Dbl,U=0.53 324.00 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:STUDY,AH:STUDY 6 300 SHGC: SHGC=0.24 b. U-Factor: Dbl,U=0.56 19.93 ft2 SHGC: SHGC=0.23 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 46.5 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 47.0 HSPF:8.20 Area Weighted Average Overhang Depth: 6.414 ft. Area Weighted Average SHGC: 0.239 8. Floor Types Insulation Area 14.Hot water systems 2 a.Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 2520.00 ft EF:0.95 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building TIE ST Construction through the above energy saving features which will be installed (or exceeded) 1 1 0 0� in this home before final inspection. Otherwise, a new EPL Display Card will be completed ��vQ`,,,,'�%' •€' �0 based on installed Code compliant f eq,4es. Builder Signature: Date: 41211, Address of New Home: _ Jl i( � Gj City/FL Zip: COD WE, 417� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient j mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) _ 638-1492 or see the EnergyGauge web site at energygauge.com for information and.a list of certified Raters. For! information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/5/2017 5:51 PM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 • i I .01191 Pro ect SummaryJob: 1Date: Jun 24,2016 • Entire House By: LINDSTROM j AIR CONOITIONINO.INC. ._ Lindstrom Air Conditioning 3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-421-4117 Fax 954-420-0064 Web:www.lindstromair.com Project I • • For: LENNAR Notes: 2500 MODEL @ MEADOWOOD I Design Information e Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 31452 Btuh Structure 27818 Btuh Ducts 4999 Btuh Ducts 5686 Btuh Central vent (80 cfm) 2456 Btuh Central vent (80 cfm) 1315 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 38907. Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 33078 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4007 Btuh Ducts 2384 Btuh Heating_ Cooling Central vent (80 cfm) 3334 Btuh i Area(ftz) 2520 2520 Equipment latent load 9725 Btuh Volume(ft') 25200 25200 Air changes/hour 0.32 0.16 Equipment total load 42803 Btuh Equiv.AVF (cfm) 134 67' Req. total capacity at 0.76 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make LENNOX Make LENNOX Trade Trade Model 14HPX-048 Cond 14HPX-048 j AHRI ref Coil CBX25UH-048 ! AHRI ref Efficiency 8.2 HSPF Efficiency 14 SEER Heating input Sensible cooling 35400 Btuh Heating output 47000 Btuh @ 47OF Latent cooling 11100 Btuh Temperature rise 27 OF Total cooling 46500 Btuh Actual air flow 1600 cfm Actual air flow 1600 cfm Air flow factor 0.044 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.78 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Apr-05 18:11:09 -f - wrightsoft Right-Suite®Universal 2013 13.0.12 RSU08398 Page 1 A+CK SAPROJECTS ENERGYtA-MANUAL J1LH-250D-MW.rup Cale=MJ8 Front Door faces: N i i I ' I � I Right-M Worksheet Job: Date: Jun 24,2016 F Entire House By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD,POMPANO BEACH,FL 33059 Phone:954-421-4117 Fax 954-420-0064 Web:www.lindstromair.com 1 Room name Entire House STUDY 2 Exposed wall 249.0 ft 27.0 ft 3 Room height 10.0 ft 10.0 ft heat/cool 4 Room dimensions 13.3 x 120 ft 5 Room area 2520.0 11:2 160.0 ftz Ty Construction U-value Or HTM Area (ft� Load Area (ft2) Load number (Btuh/ft;°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yV 13A-4ocs 0.143 ne 4.00 2.55 580 546 2186 1390 0 0 0 0 1 D-h2om 0.870 ne 24.36 43.19 4 0 97 173 0 0 0 .0 1 D-h2om 0.870 ne 24.36 43.19 30 0 731 1296 0 0 0 ;0 13A-4ocs 0.143 se 4.00 2.55 390 288 1153 733 140 110 440 280 11 1D-h2om 0.870 se 24.36 31.70 30 33 731 951 30 17 731 951 1D-h2cm 0.870 se 24.36 22.27 36 72 877 802 0 0 0 0 1E-h2fm 0.690 se 19.32 19.57 12 24 232 235 0 0 0 0 r D 11DO 0.390 se 10.92 11.31 24 24 262 271 0 0 0 0 13A-4ocs 0.143 sw 4.00 Z55 625 550 2202 1400 120 120 480 305 1013-b 0.750 sw 21.00 24.15 20 16 420 483 0 0 0 0 1 D-h2om 0.870 sw 24.36 22.27 9 18 219 200 0 0 0 0 1 D-h2om 0.870 sw 24.36 31.70 10 11 244 317 0 0 0 0 ID-h2om 0.870 sw 24.36 22.27 36 72 877 802 0 0 0 .0 13A-4ocs 0.143 nw 4.00 2.55 605 448 1794 1140 0 0 0 0 ID-h2om 0.870 rw 24.36 43.19 4 0 97 173 0 0 0 0 ID-h2om 0.870 rnv 24.36 43.19 15 0 365 648 0 0 0 0 1D-h2om 0.870 nw 24.36 43.19 30 0 731 1296 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 36 0 877 1555 0 0 0 0 ID-h2omd 0.870 nw 24.36 43.19 72 0 1754 3110 0 0 0 0 12B-0Irw 0.097 - 2.72 0.85 295 273 741 233 0 0 0 0 It-D 11DO 0.390 ne 10.92 11.31 22 22 240 249 0 0 0 10 C 16D-30td 0.032 n 0.90 1.04 2520 2520 2258 2621 160 160 143 166 F 22A-cpm 1.180 n 33.04 0.00 2520 249 8227 0 160 27 892 0 I i i I i i �I I I 6 c)AED excursion 2853 217 Envelope loss/gain 27316 22930 2687 1919 12 a) Infiltration 4136 1108 489 131 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 6 1380 1 230 Appliances/other 2400 10 Subtotal(lines 6 to 13) 31452 27818 3176 2280 • Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 31452 27818 3176 2280 15 Duct loads 16% 20% 4999 5686 16% 20% 505 466 Total room load 36451 33504 3681 2746 Air required(cfm) 11600 1600 162 131 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Fk wrightl:soft- Ri 2017-Apr-05 18:11:09 ght-Suite®Universal 2013 13.0.12 RSU08398 Page 1 �CA SAPROJECTS ENERGYtA-MANUAL J\LH-2500-MW.rup Calc=MJ8 Front Door faces: N i I i i Right-J®Worksheet Job. w Enure House Date: Jun 24,2016 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD,POMPANO BEACH,IFL 33069 Phone:954-421-4117 Fax 954-420-0064 Web:www.lindstromair.com 1 Room name TIOL MASTER MASTER BATH 2 Exposed wall O ft O ft 3 Room height 10.0 ft heat/cool 10.0 ft heaticool 4 Room dimensions 3.5 x 6.0 ft 11.0 x 12.0 It 5 Room area 21.0 f12 132.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 t 13A-4ocs 0.143 ne 4.00 255 0 0 0 0 0 0 0 '0 1D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 ;0 1 D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 10 11 ID-h2om 0.870 se 24.36 31.70 0 0 0 0 0 0 0 i0 1D-h2om 0.870 se 24.36 22.27 0 0 0 0 0 0 0 0 1E-h2fm 0.690 se 19.32 19.57 0 0 0 0 0 0 0 0 * D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 ;0 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 115 106 424 270 10B-b 0.750 sw 21.00 24.15 0 0 0 0 0 0 0 10 1 D-h2om 0.870 sw 24.36 22.27 0 0 0 0 9 9 219 266 1 D-h2om 0.870 sw 24.36 31.70 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 22.27 0 0. 0 0 0 0 0 0 13A-4ocs 0.143 rw 4.00 Z55 0 0 0 0 0 0 0 i0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 ID-h2omd 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 12B-0bw 0.097 - 2-72 0.85 0 0 0 0 0 0 0 0 it-D 11DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 10 C 16D-301d 0.032 n 0.90 1.04 21 21 19 22 132 132 118 137 F 22A-cpm 1.180 n 33.04 0.00 21 0 0 0 132 0 0 0 i i i I i i i r i 6 c)AED excursion -1 175 Envelope loss/gain 19 21 762 752 12 a) Infiltration 0 0 216 58 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 10 Subtotal(lines 6 to 13) 19 21 978 840 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 I0 14 Subtotal 19 21 978 840 15 Duct loads 16% 20% 3 4 16% 20% 155 172 Total room load 22 25 1134 1012 Air required(cfm) 1 1 50 48 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- Riglit-Suite®Universal 2013 13.0.12 RSU08398 2017-Apr-OS 18: ge Page 2 2 ACCK S:\PROJECTS ENERGY\A-MANUAL J1LH-2500-MW.rup Calc=MJ8 Front Door faces: N i I i � Right-J®Worksheet Job: House Date: Jun 24,2016 1 By: LINDSTROM �- Lindstrom Air Conditioning 3581 W MCNAB RD,POMPANO BEACH,IFL 33069 Phone:954-421-4117 Fax 954-420-0064 Web:www.lindstromaircom 1 Room name WIC EXT MASTER WIC MASTER INT I 2 Exposed wall 10.0 ft 0 ft 3 Room height ; 10.0 ft heat/cool 10.0 ft heat/coo, 4 Room dimensions 5.0 x 10.0 ft 5.0 x 8.0 ft 5 Room area 50.0 ft2 40.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load I number (Btuhlft2-°F) (Btulvft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat I Cool Gross N/P/S Heat Cool j 6 13A-4ocs -0.143 ne 4.00 255 0 0 0 0 0 0 0 0 ID-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 13A-4ocs 0.143 se 4.00 2-55 0 0 0 0 0 0 0 0 11 1D-h2om 0.870 se 24.36 31.70 0 0 0 0 0 0 0 0 ID-h2om '0.870 se 24.36 22.27 0 0 0 0 0 0 0 0 1E-h2fm 0.690 se 19.32 19.57 0 0 0 0 0 0 0 0 DD 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 10B-b 0.750 sw 21.00 24.15 0 0 0 0 0 0 0 0 ID-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 0 1D-h2om 0.870 sw 24.36 31.70 0 0 0 0 0 0 0 0 1D-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 ID-h2omd 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 126-0bw 0.097 - 272 0.85 0 0 0 0 0 0 0 0 It-D 11130 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 C 16D-30td 0.032 n 0.90 1.04 50 50 45 52 40 40 36 42 F 22A-cpm 1.180 n 33.04 0.00 50 10 330 0 40 0 0 0 6 c)AED excursion -2 2 Envelope loss/gain 1 375 50 1 36 40 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 375 50 36 40 Less external load 0 0 0 ' 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 375 50 36 40 15 Duct loads 16% 20% 60 10 16% 20% 6 ii Total room load 435 60 42 48 Air required(cfm) 19 3 2 2 I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ wrigF�tsofC I 'I 2017-Apr-05 18:11:09 Right-S uite®Universal 2013 13.0.12 RSU08398 Page 3 'CC-P, S:\PROJECTS ENERGM-MANUAL J\LH-2500-MW.rup Calc=MJ8 Front Door faces: N I i i a I I ' I r \ w Right-J®Worksheet Job. Entrre House Date: Jun 24,2016 �- Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD,POMPANO BEACH;FL 33069 Phone:954-421-4117 Fax 954-420-0064 Web:www.lindstromaircom 1 Room name MASTER SUITE DINING FOYER 2 Exposed wall 44.0 ft 27.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 14.0 x 21.0 ft 18.0 x 15.0 ft 5 Room area 294.0 ft' 270.0 ft' Ty Construction U-value Or HTM Area (ft� Load Area (W) Load number (Btuh/ftz°F) (Btuh/ft5 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 ne 4.00 Z55 120 120 480 305 0 0 0 '0 1D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 lo 1D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 180 108 432 275 11 1D-h2om 0.870 se 24.36 31.70 0 0 0 0 0 0 0 0 1D-h2om 0.870 se 24.36 22.27 0 0 0 0 36 36 877 802 1E-h2fm 0.690 se 19.32 19.57 0 0 0 0 12 12 232 235 D 11D0 0.390 se 10.92 11.31 0 0 0 0 24 24 262 271 13A-4ocs 0.143 sw 4.00 Z55 180 170 681 433 0 0 0 .0 10B-b 0.750 sw 21.00 24.15 0 0 0 0 0 0 0 :0 ID-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 10 1 D-h2om 0.870 sw 24.36 31.70 10 6 244 317 0 0 0 .0 1D-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 .0 13A-4ocs 0.143 nw 4.00 2.55 140 110 440 280 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 '0 ID-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 30 0 731 1296 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 ID-h2omd 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 R 12B-0bw 0.097 - 272 0.85 0 0 0 0 90 90 244 77 �--•D 11DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 C 16D-30td 0.032 n 0.90 1.04 294 294 263 306 270 270 242 281 F 22A-cpm 1.180 n 33.04 0.00 294 44 1454 0 270 27 892 .0 i I I I I ' I i I I 6 c)AED excursion 478 .89 Envelope loss/gain 4293 3415 3182 1851 12 a) Infiltration 827 222 338 91 b) Room ventilation 0 0 0 :0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 5120 4097 3520 1942 Less extemal load 0 0 0 0 Less transfer 0 0 0 10 Redistribution 0 0 0 �0 14 Subtotal 5120 4097 3520 1942 15 Duct loads 16% 20% 814 837 16% 20% 560 397 Total room load 5934 4934 1 4080 2339 Air required(cfm) 260 236 179 112 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigf�tsoft- 2017-Apr-05 18:11:09 Right-Suite®Universal 2013 13.0.12 RSU08398 Page 4 'CCk SAPROJECTS ENERGM-MANUAL ALH-250D-MW.rup Calc=MJ8 Front Door faces: N I Right-J®Worksheet Job: Entire House Date: Jun 24,2016 Lindstrom Air Conditioning By: LINDSTROM I 3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-4214117 Fax 954420-0064 Web:www.lindstromair.com 1 Room name GREAT ROOM PANTRY 2 Exposed wall 18.0 ft 4.5 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 18.0 x 18.0 ft 4.0 x 6.0 ft 5 Room area 324.0 ft2 24.0 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ft2) Load number (Btuhlft'-°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross' N/P/S Heat Cool Gross N/P/S Heat Cool 6 yV 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 ��----GG ID-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 1D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11 1D-h2om 0.870 se 24.36 31.70 0 0 0 0 0 0 0 0 1D-h2om 0.870 se 24.36 22.27 0 0 0 0 0 0 0 0 1E-h2fm 0.690 se 19.32 19.57 0 0 0 0 0 0 0 0 r. D 11D0 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 106-b 0.750 sw 21.00 24.15 0 0 0 0 0 0 0 0 1D-h2cm 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 31.70 0 0 0 0 0 0 0 0 1D-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 0 13A-4ccs 0.143 nw 4.00 2.55 180 108 432 275 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 ID-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 ID-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1D-h2omd 0.870 nw 24.36 43.19 72 0 1754 3110 0 0 0 0 12B-0bw 0.097 - 2.72 0.85 0 0 0 0 45 45 122 38 D 11DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 C 16D-30td 0.032 n 0.90 1.04 324 324 290 337 24 24 22 25 F 22A-cpm 1.180 n 33.04 0.00 324 18 595 0 24 5 149 0 i i I i 6 c)AED excursion 1007 I-3 Envelope loss/gain 3071 4729 292 i61 12 a) Infiltration 338 91 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 ! 0 Appliances/other 0 1 0 Subtotal(lines 6 to 13) 3410 4819 292 161 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3410 4819 292 61 15 Duct loads 16% 20% 542 985 16% 20% 46 12 Total room load 3952 5804 339 73 Air required(cfm) 173 277 15 3 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed - � wrightsoft' Right-Suite®Universal 2013 13.0.12 RSUDS398 2017-Apr-05 1 Page 5 ' � SAPROJECTS ENERGY�A-MANUAL J%LH-250D-MW.rup Calc=MJ8 Front Door faces: N I i I Right-J®Worksheet Job: w Entire House Date: Jun 24,2016 _._ Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-421-4117 Fax 954-420-0064 Web:www.lindstromair.com 1 Room name LAUNDRY KITCHEN 2 Exposed wall 16.0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 9.0 x 9.0 ft 37.5 x 10.0 ft 5 Room area 81.0 ft2 375.0 ft' Ty Construction U-value' Or HTM Area (ft� Load Area (ft� Load number (Btuh/ftz°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 % 13A-4ocs 0.143 ne 4.00 255 0 0 0 0 0 0 0 0 1 D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 13A-4ocs 0.143 se 4.00 2-55 0 0 0 0 0 0 0 0 11 1D-h2om 0.870 se 24.36 31.70 0 0 0 0 0 0 0 .0 ID-h2om 0.870 se 24.36 22.27 0 0 0 0 0 0 0 0 1E-h2rm 0.690 se 19.32 19.57 0 0 0 0 0 0 0 0 D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 10 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 10B-b 0.750 sw 21.00 24.15 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24,36 31.70 0 0 0 0 0 0 0 0 1D-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 10 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1 D=h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1D-112om 0.870 nw 24.36 43.19 0 0 0 0 0 0 1 0 0 1 D-h2omd 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 12B-0bw 0.097 - 272 0.85 160 138 375 118 0 0 0 0 D 11DO 0.390 ne 10.92 11.31 22 22 240 249 0 0 0 0 C 16D-30td 0.032 n 0.90 1.04 81 81 73 84 375 375 336 390 F 22A-cpm 1.180 n 33.04 0.00 81 16 529 0 375 0 0 0 I i i I i f i i 6 c)AED excursion -20 -123 Envelope loss/gain 1216 431 336 267 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2400 Subtotal(lines 6 to 13) 1216 431 336 2667 • Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 b 14 Subtotal 1216 431 336 2667 15 Duct loads 16% 20% 193 88 16% 20% 53 545 Total room load 1410 519 389 3213 Air required(cfm) 62 25 17 153 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft' I 2017-Apr-05 18:11:09 Right-Suite®Universal 2013 13.0.12 RSU08398 Page 6 'CC�'` SAPROJECTS ENERGM-MANUAL J1LH-2500-MW.rup Calc=MJ8 Front Door faces: N 7 Job: Right-J®Worksheet Entire House Date: Jun 24,2016 By: LINDSTROM Lindstrom Air Conditioning 1 3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-421-4117 Fax 954420-0064 Web:www.lindstromair.com 1 Room name BREAKFAST BED 2 2 Exposed wall 20.5 ft 18.5 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 10.0 x 10.0 ft 15.0 x 12.0 ft 5 Room area 100.0 ft' 180.0 f12 Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuh/ftz°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 � 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 115 100 400 255 ID-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 ID-h2orn 0.870 ne 24.36 43.19 0 0 0 0 15 0 365 648 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 70 70 280 178 11 G 1D-h2om 0.870 se 24.36 31.70 0 0 0 0 0 0 0 0 1D-h2om 0.870 se 24.36 22:27 0 0 0 0 0 0 0 '0 1E-h2fm 0.690 se 19.32 19.57 0 0 0 0 0 0 0 0 r D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.55 100 64 256 163 0 0 0 :0 106-b 0.750 sw 21.00 24.15 0 0 0 0 0 0 0 10 1 D-h2om 0.870 sw 24.36 2227 0 0 0 0 0 0 0 0 ID-h2om 0.870 sw 24.36 31.70 0 0 0 0 0 0 0 0 113-h2om 0.870 sw 24.36 22.27 36 36 877 802 0 0 0 0 13A-4ocs 0.143 nw 4.00 Z55 105 69 276 176 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 6 0 0 0 0 0 0 ,0 ID-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 ID-h2om 0.870 nw 24.36 43.19 36 0 877 1555 0 0 0 10 1 D-h2omd 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 ,0 12B-0bw 0.097 - 2.72 0.85 0 0 0 0 0 0 0 0 D 11DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 1!0 C 16D-30td 0.032 n 0.90 1.04 100 100 90 104 180 180 161 187 F 22A-cpm 1.180 n 33.04 0.00 100 21 677 0 180 19 611 0 i I I I i i 6 c)AED excursion 944 -70 Envelope loss/gain 3053 3743 1819 1198, 12 a) Infiltration 385 103 348 93 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 3439 3846 2166 1521 Less external load 0 0 0 0 Less transfer 0 0 0 6 Redistribution 0 0 0 0 14 Subtotal 3439 3846 2166 1521 15 DuctloadS 16% 20% 547 786 160/0 20% 344 311 Total room load 3965 4632 2511 1832 Air required(cfm) 175 221 110 87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsofC 2017-Apr-05 18:11:09' Right-Suite®Universal 2013 13.0.12 RSUDS398 Page 7 ACC-PI S:IPROJECTS ENERGM-MANUAL J%LH-2500-MW.rup Calc=MJ8 Front Door faces: N -r • ' Right-M Worksheet Job: C Ltn Entire House Date: Jun 24,2016 -- w Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-421-4117 Fax 954-420-0064 Web:www.findstromaircom 1 Room name BATH 2 BED 3 2 Exposed wall 5.5 ft 14.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 11.0 x 5.0 ft 14.0 x 12.0 jft 5 Room area 55.0 ft' 168.0 ft' Ty Construction U-value Or HTM Area (ft� Load Area Load number (Btuh/W•F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat` Cool- Gross N/P/S Heat Cool Gross N/P/S Heat I' Cool 6 W 13A-4ocs 0.143 ne 4.00 255 55 51 204 130 140 125 501 318 r 1D-h2om 0.870 ne 24.36 43.19 4 0 97 173 0 0 0 10 ID-h2om 0.870 ne 24.36 43.19 0 0 0 0 15 0 365 648 13A-40cs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11 1D-h2om 0.870 se 24.36 31.70 0 0 0 0 0 0 0 0 ID-h2om 0.870 se 24.36 22.27 0 0 0 0 0 0 0 0 1E-h2fm 0.690 se 19.32 19.57 0 0 0 0 0 0 0 0 i D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 255 0 0 0 0 0 0 0 0 10B-b 0.750 sw 21.00 24.15 0 0 0 0 0 0 0 10 1 D-h2om 0.870 sw 24.36 22.27 0 0 0 0 0. 0 0 0 1 D-h2om 0.870 sw 24.36 31.70 0 0 0 0 0 0 0 0 1D-h2om 0.870 sw 24.36 2227 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 ID-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 rrw 24.36 43.19 0 0 0 0 0 0 0 0 1D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 ID-h2cmd 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1213-Obw 0.097 - 2.72 0.85 0 0 0 0 0 0 0 0 D 11DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 10 C 16D30td 0.032 n 0.90 1.04 55 55 49 57 168 168 151 175 F 22A-cpm 1.180 n 33.04 0.00 55 6 182 0 168 14 463 0 i I I 6 c)AED excursion -17 -63 Envelope loss/gain 533 343 1479 1077 12 a) Infiltration 103 28 263 70 b) Room ventilation 0 0 0 0 : 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 636 370 1742 1378 • Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 636 370 1742 1378 151 Duct loads 16% 20% 101 76 16% 20% 277 282 Total room load 737 446 2019 1660 Air required(cfm) 32121 89 79 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrightsoft' Right-Suite®Universal 2013 13.0.12 RSU08398 2017-Apr-OS 1 Page 8 S:\PROJECTS ENERGM-MANUAL J1LH-2500-MW.rup Calc=MJ8 Front Door faces: N i ' N F Righ"(')Worksheet Job: Entire House Date: Jun 24,2016 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD,POMPANO BEACH,FL 33069 Phone:954-421-4117 Fax 954-420-0054 Web:www.lindstromair.com 1 Room name BED 4 CABANA 2 Exposed wall 27.0 ft 17.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 15.0 x 12.0 ft 6.0 x 11.0 ft 5 Room area 180.0 ftz 66.0 ftz Ty Construction U-value Or HTM Area (W) Load Area (ft2) Load number (BtutVft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 ne 4.00 2.55 150 150 601 382 0 0 0 0 1D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 ID-h2om 0.87o ne 24.36 43.19 0 0 0 0 0 0 0 1 0 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11 ID-h2om 0.870 se 24.36 31.70 0 0 0 0 0 0 0 0 1D-h2om 0.870 se 24.36 2227 0 0 0 0 0 0 0 0 1E-h2fm 0.690 se 19.32 19.57 0 0 0 0 0 0 0 0 9D 11D0 0.390 se 10.92 11.31 0 0 0 0 0 0 0 j 0 13A-4ocs 0.143 sw 4.00 255 0 0 0 0 110 90 360 229 108-b 0.750 sw 21.00 24.15 0 0 0 0 20 8 420 483 1D-h2om 0.870 sw 24.36 2227 0 0 0 0 0 0 0 10 1 D-h2om 0.870 sw 24.36 31.70 0 0 0 0 0 0 0 0 ID-h2om 0.870 sw 24.36 2227 0 0 0 0 0 0 0 0 13A-4ocs 0.143 rmv 4.00 2.55 120 105 420 267 60 56 224 143 ID-h2om 0.870 nw 24.36 43.19 0 0 0 0 4 0 97 173 1D-h2om 0.870 nw 24.36 43.19 15 0 365 648 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 ID-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 ID-h2omd 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 12B-0bw 0.097 - 2.72 0.85 0 0 0 0 0 0 0 0 FL-D 11D0 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 C 16D-30td 0.032 n 0.90 1.04 180 180 161 187 66 66 59 69 F 22A-cpm 1.180 n 33.04 0.00 180 27 892 0 66 17 562 10 I I I I I I I II 6 c)AED excursion c 147 276 Envelope loss/gain 2440 1632 1723 1372 .12 a) Infiltration 508 136 320 86 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 p Appliances/other 0 0 Subtotal(lines 6 to 13) 2947 1998 2042 1457 a Less external load 0 0 0 0 Less transfer 0 0 0 d Redistribution 0 0 0 d 14 Subtotal 2947 1998 2042 1457 151 Duct loads 16% 20% 469 408 16% 20% 325 298 Total room load 3416 2406 2367 1755 Air required(cfm) 1501 115 1 104 84 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrightsofC 2017-Apr-05 18:11:09 Right-Suite®Universal 2013 13.0.12 RSU06398 SAPROJECTS ENERGIIA-MANUAL J%LH-250D-MW.rup Calc=MJ8 Front Door faces: N Page 9 I I