Loading...
HomeMy WebLinkAboutEngineering Hutting - n 0 3... 0 '3? 3 • FIELD DENSItY EII���Ie�rS REPORT at .; �. Your PrOJect is_Ou eamrnitmeti4 PROJECT NO. PSL-1316 _ TO Lennar Homes`' "Co CLIENT ,�.-LU E— } Lennar Homes, LLCI D.D. 8895 N Military Trl Ste. 101-B MAY 2017 Palm Beach Gardens, FL 33410 I� I' ATTN: Thomas Leo ;! PROJECT Meadow wood LOCATION Btwn I-95 and Johnson Rd.l Fort Pierce, FL ' II REPORT NO. 6 NO.OF DENSITIES 5 TESTED BY M. Updike DATE TESTED Apr 10, 2 017 CONTRACTOR See Supporting Lab Testing AREA Proofroll Reports for Detailed Material CONSTRUCTION TYPE (0—12") Descriptions ! DENSITY Laboratory COMPACTION NUMBER LOCATION MOISTURE DRY DENSITY Soil Identifier FIELD LAB % FIELD LAB i 16 Lot 192- Approximate Center Lt Brown Sand 6.6 12..0 108:2' 107.5 1101 S1 Trace Shell Frags 17 Lot 194- Approximate Center Lt Brown Sand 7.4 12.0 107.0 107.5 100 Sl Trace Shell Frags 18 Lot 195- Approximate Center Lt Brown Sand 6.9 12.0 107.6 107.5 100 Sl Trace Shell Frags 11 19 Lot 196- Approximate Center Lt Brown Sand 7.9 12.0 107.5 107.5 100 S1 Trace Shell Frags I� 20 Lot 197- Approximate Center Lt Brown Sand 6.8 12.0 107.2 107.5 '100 - Sl Trace Shell Frags I I I i r j I FIELD METHOD Nuclear ASTM D6938 SPEGIFIED^CUfVIPACTIONj 98 LABORATORY METHOD Modified Proctor ASTM D1557 ; yA IVSIT Its I,UDICATED COMMENTS Page 1 of 1 Apr 10,2017 ( I Nutting Engineers of Florida, Inc. PER. These test results only represent compaction measured at the location reported to a maximum depth of 12 Inches below the surface tested. Ri6a,I �t r.d-G.,1OsS_I'"RE.#i 2603 This report does not reflect bearing capacity or deeper soll conditions. This report shall not be reproduced,except in full or relied upon without prior written approval of Nutting Engineers of Florida,Inc.. Palm Beach,(561)736.4900*Broward(954)941-8700*Miami Dade(305)824-0060*Port St.Lucie(772)408.1050 j � SH ENGINEERING . WO. BOX 933,BOCA RATON,FL 33 9 (561)362-0237 362-7414 (FAX) 1 R April 12, 2017 IV LEE D APR 14 2017 St. Lucie County Building Dept. PERIA11 f ING 2300 Virginia Ave St. Lucie County, FL Fort Pierce, FL 34982 Re: Lennar, Meadowood Lot 195 'I Permit# 1703-0333 Plan Reviewer, The following revisions have been made to the construction documents for the above referenced I' location. 1. Removed detail referencing glass block on sheet 6. ,I i� o� <) .e� 39�5 OF a cS),° h� e � P.E. ,I i ,I ,l i STRUCTURAL ENGINEER, P.E. #33915 - SPECIAL INSPECTOR, S.I. #0290