HomeMy WebLinkAboutEngineering Hutting -
n 0 3... 0 '3? 3 • FIELD DENSItY
EII���Ie�rS REPORT
at .; �.
Your PrOJect is_Ou eamrnitmeti4
PROJECT NO. PSL-1316 _
TO Lennar Homes`' "Co
CLIENT ,�.-LU E— }
Lennar Homes, LLCI D.D.
8895 N Military Trl Ste. 101-B MAY 2017
Palm Beach Gardens, FL
33410 I�
I'
ATTN: Thomas Leo ;!
PROJECT Meadow wood LOCATION Btwn I-95 and Johnson Rd.l
Fort Pierce, FL ' II
REPORT NO. 6 NO.OF DENSITIES 5 TESTED BY M. Updike DATE TESTED Apr 10, 2 017
CONTRACTOR See Supporting Lab Testing
AREA Proofroll Reports for Detailed Material
CONSTRUCTION TYPE (0—12") Descriptions
!
DENSITY Laboratory COMPACTION
NUMBER LOCATION MOISTURE DRY DENSITY Soil Identifier FIELD LAB %
FIELD LAB
i
16 Lot 192- Approximate Center Lt Brown Sand 6.6 12..0 108:2' 107.5 1101
S1 Trace Shell Frags
17 Lot 194- Approximate Center Lt Brown Sand 7.4 12.0 107.0 107.5 100
Sl Trace Shell Frags
18 Lot 195- Approximate Center Lt Brown Sand 6.9 12.0 107.6 107.5 100
Sl Trace Shell Frags 11
19 Lot 196- Approximate Center Lt Brown Sand 7.9 12.0 107.5 107.5 100
S1 Trace Shell Frags I�
20 Lot 197- Approximate Center Lt Brown Sand 6.8 12.0 107.2 107.5 '100 -
Sl Trace Shell Frags
I
I
I
i
r
j
I
FIELD METHOD Nuclear ASTM D6938 SPEGIFIED^CUfVIPACTIONj 98
LABORATORY METHOD Modified Proctor ASTM D1557
; yA IVSIT Its I,UDICATED
COMMENTS
Page 1 of 1 Apr 10,2017 ( I
Nutting Engineers of Florida, Inc. PER.
These test results only represent compaction measured at the location reported to a maximum depth of 12 Inches below the surface tested. Ri6a,I �t
r.d-G.,1OsS_I'"RE.#i 2603
This report does not reflect bearing capacity or deeper soll conditions.
This report shall not be reproduced,except in full or relied upon without prior written approval of Nutting Engineers of Florida,Inc..
Palm Beach,(561)736.4900*Broward(954)941-8700*Miami Dade(305)824-0060*Port St.Lucie(772)408.1050
j �
SH ENGINEERING .
WO. BOX 933,BOCA RATON,FL 33 9
(561)362-0237 362-7414 (FAX)
1
R
April 12, 2017 IV LEE D
APR 14 2017
St. Lucie County Building Dept. PERIA11 f ING
2300 Virginia Ave St. Lucie County, FL
Fort Pierce, FL 34982
Re: Lennar, Meadowood
Lot 195 'I
Permit# 1703-0333
Plan Reviewer,
The following revisions have been made to the construction documents for the above referenced I'
location.
1. Removed detail referencing glass block on sheet 6.
,I
i�
o� <) .e�
39�5
OF
a
cS),° h� e � P.E.
,I
i
,I ,l
i
STRUCTURAL ENGINEER, P.E. #33915 - SPECIAL INSPECTOR, S.I. #0290