Loading...
HomeMy WebLinkAboutEnergy Efficiencyvile C©py FORM R405-2014 I FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: LH-2500-MW Builder Name: LENNAR HOMES Street: 9501 POINCIANA CT. Permit Office: City, State, Zip: FORT PIERCE, FL., Permit Number: Owner: 2500 MODEL LOT 197 @ MEADOWOOD Jurisdiction: Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall Types (2400.0 sqft.) Insulation - Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 2200.00 ft2 = b. Frame - Wood, Adjacent R=11.0 200.00 ftZ 3. Number of units, if multiple family 1 c. N/A R= ftZ 4. Number of Bedrooms 4 d. N/A R= ftZ 10. Ceiling Types (2520.0 sqft.) Insulation Area i 5? Is this a worst case? No a. Under Attic (Vented) R=30.0 2520.00 ftZ 6. Conditioned floor area above grade (ftZ) 2520 b. N/A R= ftZ Conditioned floor area below grade (ftZ) 0 c. N/A R= ftZ 11. Ducts R ftZ 7. Windows(343.9 sqft.) Description Area a. Sup: Attic, Ret: STUDY, AH: STUDY 6 300 a. U-Factor: Dbl, U=0.53 324.00 ftZ SHGC: SHGC=0.24 b. U-Factor:. Dbl, U=0.56 19.93 ftZ 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.23 a. Central Unit 46.5 SEER:14.00 c. U-Factor: N/A ftZ SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a. Electric Heat Pump 47.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 6.414 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2520.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2520.00 ftZ b. Conservation features b. N/A R= ftZ None c. N/A R= ftZ 15. Credits Pstat Glass/Floor Area: 0.136 Total Proposed Modified Loads: 78.58 PASS Total Baseline Loads: 81.31 I hereby certify that the plans and spec' ications covered by Review of the plans and ST`1?� this calculation are in compliance with a Flori a Energy specifications covered by this O�-04E ti _ 90 'Code. calculation indicates compliance y ��„ �''% '_ = ��.�� .A r with the Florida Energy Code. !� rnm'6 .<: PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed ' in compliance Florida Statutes. t� GOD with the Florida Energy Code. WE C¢� (OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: i - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 4/5/2017 5:51 PM 1 EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R4ns-gn14 PROJECT Title: LH-2500-MW Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2520 Lot # Owner: 2500 MODEL LOT 197 @ ME Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: LENNAR HOMES Rotate Angle: 180 Street: 9501 POINCIANA CT. Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE ,I Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site. Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range Y FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 i Low BLOCKS Number Name Area Volume 1 Entire House 2520 25200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 STUDY 180 1800 No 1 4 1 No Yes Yes 2 TIOL MASTER 21 210 No 0 1 No Yes Yes 3 MASTER BATH 132 1320 No 0 1 No Yes Yes 4 WIC EXT MASTER 50 500 No 0 1 No Yes Yes 5 WIC MASTER INT 40 400 No 0 1 No Yes Yes 6 MASTER SUITE 294 2940 No 2 1 No Yes Yes 7 DINING FOYER 270 2700 No 0 1 No Yes Yes 8 GREAT ROOM 324 3240 No 0 1 No Yes Yes 9 PANTRY 24 240 No 0 1 No Yes Yes 10 LAUNDRY 81 810 No . 0 1 No Yes Yes 11 KITCHEN 247 2470 No 0 1 No Yes Yes 12 BREAKFAST 100 1000 No 0 1 No Yes Yes 13 BED 2 180 1800 No 1 1 No Yes Yes 14 BATH 2 55 550 No 0 1 No Yes Yes 15 BED 3 168 1680 No 1 1 No Yes Yes 16 HALL TO BEDS 108 1080 No 0 1 No Yes Yes 17 BED 4 180 1800 No 1 1 No Yes Yes 18 U. CABANA 66 660 No 0 1 No Yes i Yes 4/5/2017 5:51 PM j EnergyGaugeB USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio i STUDY 27 ft 180 ft2 0 0 1 2 Slab -On -Grade Edge Insulatio i TIOL MASTER 1 ft 21 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 1 ft 132 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulatio WIC EXT MASTE 10 ft 50 ft2 ____ 0 0 1 5 Slab -On -Grade Edge Insulatio WIC MASTER IN 1 ft 40 ft2 ____ 0 0 i 1 6 Slab -On -Grade Edge Insulatio MASTER SUITE 44 ft 294 ft2 ____ 0 0 1 7 Slab -On -Grade Edge Insulatio DINING FOYER 27 ft 270 ft2 ____ 1 0 0 y 8 Slab -On -Grade Edge Insulatio GREAT ROOM 18 ft 324 ft2 ____ 0 0 1 9 Slab -On -Grade Edge Insulatio PANTRY 4.5 ft 24 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulatio LAUNDRY 16 ft 81 ft2 1 0 0 11SIab-On-Grade Edge Insulatio KITCHEN 1 ft 247 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulatio BREAKFAST 20.5 ft 100 ft2 ____ 0 0 1 13SIab-On-Grade Edge Insulatio BED 2 18.5 ft 180 ft2 0 0 1 14SIab-On-Grade Edge Insulatio BATH 2 5.5 ft 55 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulatio BED 3 14 ft 168 ft2 _—_ 0 0 1 16SIab-On-Grade Edge Insulatio HALL TO BEDS 1 ft 108 ft2 0 0 1 17SIab-On-Grade Edge Insulatio BED 4 27 ft 180 ft2 ____ 0 0 1 18SIab-On-Grade Edge Insulatio CABANA. 17 ft 66 ft2 ____ 1 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 2730 ft2 0 ft2 Medium 0.9 No 0.9 No 0 i 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2520 ft2 N_ N i 4/5/2017 5:51 PM I EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) STUDY 30 Blown 180 ft2 0.1 Wood 2 Under Attic (Vented) TIOL MASTER 30 Blown 21 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 132 ft2 0.1 Wood 4 Under Attic (Vented) WIC EXT MASTE 30 Blown 50 ft2 0.1 Wood 5 Under Attic (Vented) WIC MASTER IN 30 Blown 40 ft2 0.1 Wood 6 Under Attic (Vented) MASTER SUITE 30 Blown 294 ft2 0.1 Wood 7 Under Attic (Vented) DINING FOYER 30 Blown 270 ft2 0.1 Wood 8 Under Attic (Vented) GREAT ROOM 30 Blown 324 ft2 0.1 Wood 9 Under Attic (Vented) PANTRY 30 Blown 24 ft2 0.1 Wood I 10 Under Attic (Vented) LAUNDRY 30 Blown 81 ft2 0.1 Wood 11 Under Attic (Vented) KITCHEN 30 Blown 247 ft2 0.1 Wood I r 12 Under Attic (Vented) BREAKFAST 30 Blown 100 ft2 0.1 Wood 13 Under Attic (Vented) BED 2 30 Blown 180 ft2 0.1 Wood 14 Under Attic (Vented) BATH 2 30 Blown 55 ft2 0.1 Wood i 15 Under Attic (Vented) BED 3 30 Blown 168 ft2 0.1 Wood 16 Under Attic (Vented) HALL TO BEDS 30 Blown 108 ft2 0.1 Wood i 17 Under Attic (Vented) BED 4 30 Blown 180 ft2 0.1 Wood 18 Under Attic (Vented) CABANA 30 Blown 66 ft2 0.1 Wood WALLS I Adjacent Space Cavity Ornt 10 JA1;;11 Type13-1 Width Height Et In Area Sheathing Framing Solar; R-NIallie Pr Ctinn Ahqnr Below 0 1 SE=>NW Exterior Concrete Block - Int Insul STUDY 4.1 14 0 10 0 140.0 ft2 0 0 0.5 0 2 SW=>NE Exterior Concrete Block - Int Insul STUDY 4.1 12 0 10 0 120.0 ft2 0 0 0.5 j 0 _ 3 SW=>NE Exterior Concrete Block - Int InsfXASTER BA 4.1 11 6 10 0 115.0 ft2 0 0 0.5 0 4 NE=>SW Exterior Concrete Block - Int InsMASTER SUI 4.1 12 0 10 0 120.0 ft2 0 0 0.5 0 5 SW=>NE Exterior Concrete Block - Int InsMASTER SUI 4.1 18 0 10 0 180.0 ft2 0 0 0.5 0 6 NW=>SE Exterior Concrete Block - Int InsMASTER SUI 4.1 14 0 10 0 140.0 ft2 0 0 0.5 0 7 SE=>NW Exterior Concrete Block - Int InsMINING FOY 4.1 18 0 10 0 180.0 ft2 0 0 0.5 0 - 8 NW=>SE Exterior Concrete Block - Int InsGREAT ROO 4.1 18 0 10 0 180.0 ft2 0 0 0.5 0 9 SW=>NE Exterior Concrete Block - Int InsE IREAKFAST 4.1 10 0 10 0 100.0 ft2 0 0 i 0.5 0 10 NW=>SE Exterior Concrete Block - Int InsBIREAKFAST 4.1 10 6 10 0 105.0 ft2 0 0 0.5 0 11 NE=>SW Exterior Concrete Block - Int Insul BED 2 4.1 11 6 10 0 115.0 ft2 0 0 0.5 0 _ 12 SE=>NW Exterior Concrete Block - Int Insul BED 2 4.1 7 0 10 0 70.0 ft2 0 0 0.51 0 13 NE=>SW Exterior Concrete Block - Int Insul BATH 2 4.1 5 6 10 0 55.0 ft2 0 0 0.5 0 14 NE=>SW Exterior Concrete Block - Int Insul BED 3 4.1 14 0 10 0 140.0 ft2 0 0 0.5 0 15 NE=>SW Exterior Concrete Block - Int Insul BED 4 4.1 15 0 10 0 150.0 ft2 0 0 0.5; 0 16 NW=>SE Exterior Concrete Block - Int Insul BED 4 4.1 12 0 10 0 120.0 ft2 0 0 0.51 0 17 SW=>NE Exterior Concrete Block - Int Insul CABANA 4.1 11 0 10 0 110.0 ft2 0 0 0.5 0 _18 NW=>SE Exterior Concrete Block - Int Insul CABANA 4.1 6 0 10 0. 60.0 ft2 0 0 0.51 0 19 NE=>SW Garage Frame - Wood STUDY 11 20 10 200.0 ft2 0.23 0.75 0 4/5/2017 5:51 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 i DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In I 1 SE=>NW WoodDINING FOY None .39 3 7 6 8 23.9 ft2 WINDOWS Orientation shown is the entered orientation (=>) changed to As Built (rotated 180 degrees). Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 SE=>NW 1 Metal Double (Tinted) Yes 0.53 0.24 30.0 ft2 2 ft 0 in 1 ft 0 in None j None 2 SW=>NE 3 Metal Double (Tinted) Yes 0.53 0.24 9.0 ft2 2 ft 0 in 1 ft 0 in None None 3 SW=>NE 5 Metal Double (Tinted) Yes 0.53 0.24 10.0 ft2 2 ft 0 in 1 ft 0 in None None 4 NW=>SE 6 Metal Double (Tinted) Yes 0.53 0.24 30.0 ft2 2 ft 0 in 1 ft 0 in None None 5 SE=>NW 7 Metal Double (Tinted) Yes 0.53 0.24 36.0 ft2 8 ft 0 in 1 ft 0 in None None 6 SE=>NW 7 Metal Double (Tinted) Yes 0.53 0.24 12.0 ft2 8 ft 6 in 1 ft 0 in None None 7 NW=>SE 8 Metal Double (Tinted) Yes 0.53 0.24 72.0 ft2 11 ft 6 in 1 ft 0 in None None 8 SW=>NE 9 Metal Double (Tinted) Yes 0.53 0.24 36.0 ft2 17 ft 0 in 1 ft 0 in None None 9 NW=>SE10 Metal Double (Tinted) Yes 0.53 0.24 36.0 ft2 2 ft 0 in 1 ft 0 in None None .10 NE=>SW11 Metal Double (Tinted) Yes 0.53 0.24 15.0 ft2 2 ft 0 in 1 ft 0 in None j None 11 NE=>SW13 Metal Double (Tinted) Yes 0.53 0.24 4.0 ft2 2 ft 0 in 1 ft 0 in None None 12 NE=>SW 14 Metal Double (Tinted) Yes 0.53 0.24 15.0 ft2 2 ft 0 in 1 ft 0 in None None 13 NW=>SE16 Metal Double (Tinted) Yes 0.53 0.24 15.0 ft2 2 ft 0 in 1 ft 0 in None None 14 SW=>NE17 TIM Double (Tinted) Yes 0.56 0.23 19.9 ft2 2 ft 0 in 1 ft 0 in None None 15 NW=>SE18 Metal Double (Tinted) Yes 0.53 0.24 4.0 ft2 2 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation , 1 382.8 ft2 382.8 ft2 64 ft 8 ft 1 I INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 _Wholehouse Proposed ACH(50) .000318 2100 115.29 216.81 .2319 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 47 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 14 46.5 kBtu/hr 1395 cfm 0.75 1 sys#1 I 1 4/5/2017 5:51 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 I . DUCTS I — Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 300 ft2 STUDY 100 ft2 Default Leakage STUDY (Default) (Default) 1 1 s TEMPERATURES Programable Thermostat: Y Ceiling Fans: Heat ng Jan Feb [ ]] f X] Mar Apr May rj JunX� Jul Jul May Jun Au rlAug X� �X� ct �X1 Nov Nov Venting Jan Feb [Dec X Mar Lr LSep Oct Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 1 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM. 68 68 68 68 68 68 68 68 68 68 66 66 R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 9501 POINCIANA CT., FORT PIERCE, FL, 1. New construction or existing 2.:Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms i 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Dbl, U=0.53 SHGC: SHGC=0.24 b. U-Factor: Dbl, U=0.56 SHGC: SHGC=0.23 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: New (From Plans) 9. Wall Types Insulation Single-family a. Concrete Block - Int Insul, Exterior R=4.1 b. Frame - Wood, Adjacent R=11.0 1 c. N/A R= 4 d. N/A R= 10. Ceiling Types Insulation No a. Under Attic (Vented) R=30.0 2520 b. N/A R= Area c. N/A R- 324.00 ft2 11. Ducts a. Sup: Attic, Ret: STUDY, AH: STUDY 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= 19.93 ft2 12. Cooling systems ft2 a. Central Unit ft2 13. Heating systems a. Electric Heat Pump 6.414 ft. 0.239 Area 14. Hot water systems 2520.00 ft2 a. Electric ft2 b. Conservation features ft2 None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code fo Construction through the above energy saving features which will be installed ( in this home before final inspection. Otherwise, a new EPL Display Card will bi based on installed Code compliant fea,4es. Builder Signature: 9�8-Date: 12 Address of New Home: _ Jl 1 M"� Gj City/FL Zip: M i Area 2200.00 ft2 200.00 ft2 ft? ft? Area 1 2520.00 ft? ft2 ft2 R ft2 6 300 kBtu/hr Efficiency 46.5 SEER:14.00 kBtu/hr Efficiency 47.0 HSPF:8.20 Cap: 50 gallons EF: 0.95 I i Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient j mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and.a list of certified Raters. For! information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/5/2017 5:51 PM EnergyGauge@ USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 i I i I Pro ect Summary Job: 1 Date: Jun 24, 2016 ;,.��t,,a•,,, Entire House By: LINDSTROM j •1■ CONGITIONINO. INC. �._ Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax 954-420-0064 Web: www.lindstromair.com Project I• • For: LENNAR Notes: 2500 MODEL @ MEADOWOOD I Design Information e Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 31452 Btuh Structure 27818 Btuh Ducts 4999 Btuh Ducts 5686 Btuh Central vent (80 cfm) 2456 Btuh Central vent (80 cfm) 1315 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 38907. Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 33078 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4007 Btuh Ducts 2384 Btuh Heating_ Cooling Central vent (80 cfm) 3334 Btuh Area (ftz) 2520 2520 Equipment latent load 9725 Btuh Volume (ft') 25200 25200 Air changes/hour 0.32 0.16 Equipment total load 42803 Btuh Equiv. AVF (cfm) 134 67 ' Req. total capacity at 0.76 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary ' Make LENNOX Make LENNOX Trade Trade Model 14HPX-048 Cond 14HPX-048 j AHRI ref Coil CBX25UH-048 ! AHRI ref Efficiency 8.2 HSPF Efficiency 14 SEER Heating input Sensible cooling 35400 Btuh Heating output 47000 Btuh @ 47°F Latent cooling 11100 Btuh Temperature rise 27 OF Total cooling 46500 Btuh Actual air flow 1600 cfm Actual air flow 1600 cfm Air flow factor 0.044 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.78 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Apr-05 18:11:09 wrightsoftRight-Suite® Universal 2013 13.0.12 RSU08398 Page 1 A+Ch SAPROJECTS ENERGYtA- MANUAL J1LH-250D-MW.rup Cale = MJ8 Front Door faces: N r` Right-M Worksheet Job: Entire House Date: Jun 24, 2016 Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33059 Phone: 954-421-4117 Fax 954-420-0064 Web: www.lindstromair.com 1 Room name Entire House STUDY 2 Exposed wall 249.0 ft 27.0 ft 3 Room height 10.0 ft 10.0 ft heat/cool 4 Room dimensions 13.3 x 120 ft 5 Room area 2520.0 11:2 160.0 ftz Ty Construction U-value Or HTM Area (ft� Load Area (W) Load number (Btuh/ft;°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yV 13A-4ocs 0.143 ne 4.00 2.55 580 546 2186 1390 0 0 0 0 1 D-h2om 0.870 ne 24.36 43.19 4 0 97 173 0 0 0 .0 t�-- GG 1 D-h2om 0.870 ne 24.36 43.19 30 0 731 1296 0 0 0 :0 13A4ocs 0.143 se 4.00 2.55 390 288 1153 733 140 110 440 280 11 1D-h2om 0.870 se 24.36 31.70 30 33 731 951 30 17 731 951 1D-h2cm 0.870 se 24.36 22.27 36 72 877 802 0 0 0 0 1E-h2fm 0.690 se 19.32 19.57 12 24 232 235 0 0 0 0 D 11DO 0.390 se 10.92 11.31 24 24 262 271 0 0 0 0 13A-4ocs 0.143 sw 4.00 Z55 625 550 2202 1400 120 120 480 305 106-b 1 D-h2om 0.750 0.870 sw sw 21.00 24.36 24.15 22.27 20 9 16 18 420 219 483 200 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 31.70 10 11 244 317 0 0 0 0 ID-h2om 0.870 sw 24.36 22.27 36 72 877 802 0 0 0 .0 13A-4ocs 0.143 nw 4.00 2.55 605 448 1794 1140 0 0 0 0 ID-h2om 0.870 rw 24.36 43.19 4 0 97 173 0 0 0 0 1D-h2om 0.870 rnv 24.36 43.19 15 0 365 648 0 0 0 0 1D-h2om 0.870 nw 24.36 43.19 30 0 731 1296 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 36 0 877 1555 0 0 0 0 ID-h2omd 0.870 nw 24.36 43.19 72 0 1754 3110 0 0 0 0 It-D 12B-0bw 0.097 - 2.72 0.85 295 273 741 233 0 0 0 0 11DO 0.390 ne 10.92 11.31 22 22 240 249 0 0 0 10 C 16D-30td 0.032 n 0.90 1.04 2520 2520 2258 2621 160 160 143 166 F 22A-cpm 1.180 n 33.04 0.00 2520 249 8227 0 160 27 892 0 I i i I i i I i I 6 c) AED excursion 2853 217 Envelope loss/gain 27316 22930 2687 1919 12 a) Infiltration 4136 1108 489 131 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 6 1380 1 230 Appliances/other 2400 1 10 Subtotal (lines 6 to 13) 31452 27818 3176 2280 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 31452 0 0 27818 0 0 3176 0 0 2280 15 Duct loads 16% 20% 4999 5686 16% 20% 505 466 Total room load 36451 33504 3681 2746 Air required (cfm) 1 11600 1600 162 131 -Fk wrightl:soft- I Rlgt �CA S:\PROJECTS ENERGY\A- MAN approved by ACCA to meet all requirements of Manual J 8th Ed. i e® Universal 2013 13.0.12 RSU08398 2017-Apr-05 18:11:09 Page 1 J\LH-2500.MW.rup Calc = MJS Front Door faces: N i Right-J® Worksheet Job: w Entire House Date: Jun 24, 2016 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH,IFL 33069 Phone: 954-421-4117 Fax 954-420-0064 Web: www.lindstromair.com 1 Room name TIOL MASTER MASTER BATH 2 Exposed wall O ft O ft 3 Room height 10.0 ft heat/cool 10.0 ft heaticool 4 Room dimensions 3.5 x 6.0 ft 11.0 x 12.0 It 5 Room area 21.0 f12 132.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (BtutV t2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 t 13A-4ocs 0.143 ne 4.00 255 0 0 0 0 0 0 0 0 1D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 ;0 1 D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 10 11 ID-h2om 0.870 se 24.36 31.70 0 0 0 0 0 0 0 i0 1D-h2om 0.870 se 24.36 22.27 0 0 0 0 0 0 0 0 1E-h2fm 11DO 0.690 0.390 se se 19.32 10.92 19.57 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ;0 D 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 115 106 424 270 10B-b 0.750 sw 21.00 24.15 0 0 0 0 0 0 0 10 1 D-h2om 0.870 sw 24.36 22.27 0 0 0 0 9 9 219 260 1 D-h2om 0.870 sw 24.36 31.70 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 22.27 0 0. 0 0 0 0 0 0 13A-4ocs 0.143 rw 4.00 Z55 0 0 0 0 0 0 0 i0 1 D-h2om 1D-h2om 0.870 0.870 nw nw 24.36 24.36 43.19 43.19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 ID-h2omd 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 it-D 12B-0bw 0.097 - 2-72 0.85 0 0 0 0 0 0 0 0 11DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 10 C 16D-301d 0.032 n 0.90 1.04 21 21 19 22 132 132 118 137 F 22A-cpm 1.180 n 33.04 0.00 21 0 0 0 132 0 0 0 i i r i I i i i i 6 c) AED excursion -1 175 Envelope loss/gain 19 21 762 752 12 a) Infiltration 0 0 216 58 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 10 Subtotal (lines 6 to 13) 19 21 978 840 Less external load 0 0 0 I 0 Less transfer Redistribution 0 0 0 0 0 0 0 I0 14 Subtotal 19 21 978 840 15 Duct loads 16% 20% 3 4 16% 20% 155 172 Total room load 22 25 1134 1012 Air required (cfm) 1 1 50 48 ACCA to meet all requirements of Wrightsoft- Riglit-Suite® Universal 2013 13.0.12 RSU08398 ACCK S:\PROJECTS ENERGYW- MANUAL J1LH-2500-MW.rup Calc = MJ8 Front Door faces: N i 2017-Apr-05 18:11:99 Page 2 Right-J® Worksheet Entire House cLt���i i �- Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, !FL 33069 Phone: 954-421-4117 Fax 954-420-0064 Web: www.lindstromaircom Job: Date: Jun 24, 2016 By: LINDSTROM 1 Room name WIC EXT MASTER i WIC MASTER INT 1 2 Exposed wall 10.0 ft 0 ft 3 Room height ; 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 5.0 x 10.0 ft 5.0 x 8.0 ft 5 Room area 50.0 ft2 40.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load I number (Btuhlft2-°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat I Cool Gross N/P/S Heat Cool j 6 13A-4ocs -0.143 ne 4.00 255 0 0 0 0 0 0 0 0 ID-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 13A-40cs 0.143 se 4.00 2-55 0 0 0 0 0 0 0 0 11 1D-h2om 0.870 se 24.36 31.70 0 0 0 0 0 0 0 0 ID-h2om '0.870 se 24.36 22.27 0 0 0 0 0 0 0 0 1E-h2fm 0.690 se 19.32 19.57 0 0 0 0 0 0 0 0 D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 10B-b 0.750 sw 21.00 24.15 0 0 0 0 0 0 0 0 ID-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 0 1D-h2om 0.870 sw 24.36 31.70 0 0 0 0 0 0 0 0 1D-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 0 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 ID-h2omd 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 lt-D 126-0bw 0.097 - 272 0.85 0 0 0 0 0 0 0 0 11130 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 C 16D-30td 0.032 n 0.90 1.04 50 50 45 52 40 40 36 42 F 22A-cpm 1.180 n 33.04 0.00 50 10 330 0 40 0 0 0 6 c) AED excursion -2 2 Envelope loss/gain 375 50 36 40 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 375 50 36 40 Less external load 0 0 0 ' 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 375 50 36 40 15 Duct loads 16% 20% 60 10 16°/a 20% 6 ii Total room load 435 60 42 48 Air required (cfm) 19 3 2 2 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. I _ wrigF�tsofC I 'I 2017-Apr-05 18:11:09 Right -Suite® Universal 2013 13.0.12 RSU08398 Page 3 'CC-N S:\PROJECTS ENERGM- MANUAL J\LH-2500-MW.rup Calc = MJ8 Front Door faces: N I i 5 ..I Right-J® Worksheet Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH; FL 33069 Phone: 954-421-4117 Fax 954-420-0064 Web: www.lindstromaircom Job: Date: Jun 24, 2016 By: LINDSTROM 1 Room name MASTER SUITE DINING FOYER 2 Exposed wall 44.0 ft 27.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 14.0 x 21.0 ft 294.0 ft' 18.0 x 15.0 ft 270.0 ft' Ty Construction U-value Or HTM Area (ft� Load Area (W) Load number (Btuh/ftz °F) (Btuh/ft5 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 ne 4.00 255 120 120 480 305 0 0 0 ' 0 1D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 lo 1D-h2om 13A-4ocs 0.870 0.143 ne se 24.36 4.00 43.19 2.55 0 0 0 0 0 0 0 0 0 180 0 108 0 432 0 275 11 1D-h2om 0.870 se 24.36 31.70 0 0 0 0 0 0 0 0 1D-h2om 0.870 se 24.36 22.27 0 0 0 0 36 36 877 802 1E-h2fm 0.690 se 19.32 19.57 0 0 0 0 12 12 232 235 D 11D0 0.390 se 10.92 11.31 0 0 0 0 24 24 262 271 13A-4ocs 0.143 sw 4.00 Z55 180 170 681 433 0 0 0 .0 10B-b ID-h2om 0.750 0.870 sw sw 21.00 24.36 24.15 22.27 0 0 0 0 0 0 0 0 0 0 0 0 0 0 :0 10 1 D-h2om 0.870 sw 24.36 31.70 10 6 244 317 0 0 0 1D-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 .0 .0 13A-4ocs 0.143 nw 4.00 2.55 140 110 440 280 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 '0 ID-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 30 0 731 1296 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 ID-h2omd 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 R 12B-0bw 0.097 - 272 0.85 0 0 0 0 90 90 244 77 �--•D 11DO 0.390 ne 10.92 11.31 0 0 0 0 0 0 0 0 C 16D-30td 0.032 n 0.90 1.04 294 294 263 306 270 270 242 281 F 22A-cpm 1.180 n 33.04 0.00 294 44 1454 0 270 27 892 ' .0 i I i I I I i I I I 6 c) AED excursion 478 .89 Envelope loss/gain 4293 3415 3182 1851 12 a) Infiltration 827 222 338 91 b) Room ventilation 0 0 0 :0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 5120 4097 3520 1942 14 151 Less extemal load Less transfer Redistribution Subtotal Duct loads 16% 20% 0 0 0 5120 814 0 0 0 4097 837 16% 20% 0 0 0 3520 5601 10 10 � 0 1942 397 Total room load Air required (cfm) 5934 260 4934 236 4080 179 2339 112 r ACCA to meet all rec -�- wrightsoft- Right-Suite® Universal 2013 13.0.12 RSU08398 'CCk SAPROJECTS ENERGM- MANUAL ALH-250D-MW.rup Calc = MJ8 Front Door faces: N 2017-Apr-05 18:11:09 Page4 f 6 i- d Right-J® Worksheet Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-4214117 Fa)c 954420-0064 Web: www_lindstrmmnircnm Job: Date: Jun 24, 2016 By: LINDSTROM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area GREAT ROOM 18.0 ft 10.0 ft heat/cool 18.0 x 18.0 ft 324.0 ft2 PANTRY 4.5 ft 10.0 ft heat/cool 4.0 x 6.0 ft 24.0 ft' Ty Construction number U-value (Btuhlft'-°F) Or HTM (Btuh/ft� Area (ft� or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross' N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 yV 13A-4ocs ID-h2om 1D-h2om 13A-4ocs 1D-h2om 1D-h2om 1E-h2fm 11D0 13A-4ocs 106-b 1D-h2cm 1 D-h2om 1D-h2om 13A-4ccs 1 D-h2om ID-h2om 1 D-h2om ID-h2om 1D-h2omd 12B-0bw 11DO 16D-30td 22A-cpm 0.143 0.870 0.870 0.143 0.870 0.870 0.690 0.390 0.143 0.750 0.870 0.870 0.870 0.143 0.870 0.870 0.870 0.870 0.870 0.097 0.390 0.032 1.180 ne ne ne se se se se se sw sw sw sw sw nw nw nw nw nw nw - ne n n 4.00 24.36 24.36 4.00 24.36 24.36 19.32 10.92 4.00 21.00 24.36 24.36 24.36 4.00 24.36 24.36 24.36 24.36 24.36 2.72 10.92 0.90 33.04 2.55 43.19 43.19 2.55 31.70 22.27 19.57 11.31 2.55 24.15 22.27 31.70 22.27 2.55 43.19 43.19 43.19 43.19 43.19 0.85 11.31 1.04 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 180 0 0 0 0 72 0 0 324 324 0 0 0 0 0 0 0 0 0 0 0 0 0 108 0 0 0 0 0 0 0 324 18 0 0 0 0 0 0 0 0 0 0 0 0 0 432 0 0 0 0 1754 0 0 290 595 0 0 0 0 0 0 0 0 0 0 0 0 0 275 0 0 0 0 3110 0 0 337 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 45 0 24 24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 45 0 24 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 122 0 22 149 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 38 0 25 0 i i I ��----GG G D D C F 6 c) AED excursion 1007 I-3 Envelope loss/gain 3071 4729 292 i61 12 a) Infiltration b) Room ventilation 338 0 91 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 ! 0 1 0 Subtotal (lines 6 to 13) 3410 4819 292 161 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 16% 20% 0 0 0 3410 542 0 0 0 4819 985 16% 20% 0 0 0 292 46 0 0 0 61 -12 Total room load Air required (cfm) 3952 173 5804 277 339 15 73 3 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed - � wrightsoft' Right -Suite® Universal 2013 13.0.12 RSUDS398 2017-Apr-05 1 Page 5 '� SAPROJECTS ENERGYtA- MANUAL J%LH-250D-MW.rup Calc = MJ8 Front Door faces: N Right-J® Worksheet Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax 954-420-0064 Web: www.lindstromair.com Job: Date: Jun 24, 2016 By: LINDSTROM 1 Room name LAUNDRY KITCHEN 2 Exposed wall 16.0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 9.0 x 9.0 ft 81.0 ft2 37.5 x 10.0 ft 375.0 ft' Ty Construction U-value ' Or HTM Area (ft� Load Area (ft� Load number (Btuh/ftz°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6% 13A-4ocs 0.143 ne 4.00 255 0 0 0 0 0 0 0 0 1 D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 ne 24.36 43.19 0 0 0 0 0 0 0 0 G 13A-4ocs 0.143 se 4.00 2-55 0 0 0 0 0 0 0 0 11 1D-h2om 0.870 se 24.36 31.70 0 0 0 0 0 0 0 .0 ID-h2om 0.870 se 24.36 22.27 0 0 0 0 0 0 0 0 1E-h2rm 0.690 se 19.32 19.57 0 0 0 0 0 0 0 0 D 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 10 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 10B-b 0.750 sw 21.00 24.15 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 0 1 D-h2om 0.870 sw 24.36 31.70 0 0 0 0 0 0 0 0 1D-h2om 0.870 sw 24.36 22.27 0 0 0 0 0 0 0 10 13A-4ocs 1 D=h2om 0.143 0.870 nw nw 4.00 24.36 2.55 43.19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 1D-112om 0.870 nw 24.36 43.19 0 0 0 0 0 0 1 0 0 1 D-h2omd 0.870 nw 24.36 43.19 0 0 0 0 0 0 0 0 12B-0bw 0.097 - 272 0.85 160 138 375 118 0 0 0 0 D 11DO 0.390 ne 10.92 11.31 22 22 240 249 0 0 0 0 C 16D-30td 0.032 n 0.90 1.04 81 81 73 84 375 375 336 390 F 22A-cpm 1.180 n 33.04 0.00 81 16 529 0 375 0 0 0 I i i I f i 6 c) AED excursion -20 -123 Envelope loss/gain 1216 431 336 267 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 1ntemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2400 Subtotal (lines 6 to 13) 1216 431 336 2667 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 16% 20% 0 0 0 1216 193 0 0 0 431 88 16% 20% 0 0 0 336 53 0 0 b 2667 545 Total room load Air required (cfm) 1410 62 519 25 389 17 3213 153 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft' I 2017-Apr-05 18:11:09 Right -Suite® Universal 2013 13.0.12 RSU08398 Page 6 'C0'` SAPROJECTS ENERGM- MANUAL J1LH-2500-MW.rup Calc = MJ8 Front Door faces: N I Right-J® Worksheet Ce:tn"- Entire House �- Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax 954420-0064 Web: www.findstromair.com Job: Date: Jun 24, 2016 By: LINDSTROM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BREAKFAST 20.5 ft 10.0 ft heat/cool 10.0 x 10.0 ft 100.0 ft' BED 2 18.5 ft 10.0 ft heat/cool 15.0 x 12.0 ft 180.0 f12 Ty Construction number U-value (Btuh/ftMF) Or HTM (Btuh/ft� Area (ft� or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 � 13A-4ocs ID-h2om ID-h2orn 13A-4ocs 1D-h2om 1D-h2om 1E-h2fm 11DO 13A-4ocs 106-b 1 D-h2om ID-h2om 113-h2om 13A-4ocs 1 D-h2om 1 D-h2om ID-h2om ID-h2om 1 D-h2omd 12B-0bw 11DO 16D-30td 22A-cpm 0.143 0.870 0.870 0.143 0.870 0.870 0.690 0.390 0.143 0.750 0.870 0.870 0.870 0.143 0.870 0.870 0.870 0.870 0.870 0.097 0.390 0.032 1.180 ne ne ne se se se se se sw sw sw sw sw nw nw nw nw nw nw - ne n n 4.00 24.36 24.36 4.00 24.36 24.36 19.32 10.92 4.00 21.00 24.36 24.36 24.36 4.00 24.36 24.36 24.36 24.36 24.36 2.72 10.92 0.90 33.04 2.55 43.19 43.19 2.55 31.70 22:27 19.57 11.31 2.55 24.15 2227 31.70 22.27 Z55 43.19 43.19 43.19 43.19 43.19 0.85 11.31 1.04 0.00 0 0 0 0 0 0 0 0 100 0 0 0 36 105 0 6 0 36 0 0 0 100 100 0 0 0 0 0 0 0 0 64 0 0 0 36 69 0 0 0 0 0 0 0 100 21 0 0 0 0 0 0 0 0 256 0 0 0 877 276 0 0 0 877 0 0 0 90 677 0 0 0 0 0 0 0 0 163 0 0 0 802 176 0 0 0 1555 0 0 0 104 0 115 0 15 70 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 180 180 100 0 0 70 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 180 19 400 0 365 280 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 161 611 255 0 648 178 0 '0 0 0 :0 10 0 0 0 0 0 0 0 10 ,0 0 10 187 0 i I i i G D D C F 6 c) AED excursion 944 -70 Envelope loss/gain 3053 3743 1819 1198 12 a) Infiltration b) Room ventilation 385 0 103 0 348 0 93 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 1 230 0 Subtotal (lines 6 to 13) 3439 3846 2166 1521 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 16% 20% 0 0 0 3439 547 0 0 0 3846 786 160/0 20% 0 0 0 2166 344 0 6 0 1521 311 Total room load Air required (cfm) 3985 175 4632 221 1 1 2511 110 1832 87 / ACCA to meet all rec * Wrightsoft' Right -Suite® Universal 2013 13.0.12 RSUCS398 ACC -PI S:IPROJECTS ENERGM- MANUAL J%LH-2500-MW.rup Calc = MJ8 Front Door faces: N 8th Ed. 2017-Apr-05 18:11:C Page r Right-J® Worksheet w Enure House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax 954-42o-nnh4 i V Job: Date: Jun 24, 2016 By: LINDSTROM WPh- � linrfcfrnm,irrnm 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BATH 2 5.5 ft 10.0 ft heat/cool 11.0 x 5.0 ft 55.0 ft' BED 3 14.0 ft 10.0 ft heat/cool 14.0 x 12.0 jft 168.0 ft' Ty Construction number U-value (Btuh/W °F) Or HTM (Btuh/ft� Area (ft� or perimeter (ft) Load (Btuh) Area or perimeter (ft) Load (Btuh) Heat Cool - Gross N/P/S Heat Cool Gross N/P/S Heat ; Cool 6 11 W 13A-4ocs 1D-h2om ID-h2om 13A-4ocs 1D-h2om ID-h2om 1E-h2fm 11DO 13A-4ocs 10B-b 1 D-h2om 1 D-h2om 1D-h2om 13A-4ocs ID-h2om 1 D-h2om 1D-h2om 1 D-h2om ID-h2cmd 1213-Obw 11DO 16D30td 22A-cpm 0.143 0.870 0.870 0.143 0.870 0.870 0.690 0.390 0.143 0.750 0.870 0.870 0.870 0.143 0.870 0.870 0.870 0.870 0.870 0.097 0.390 0.032 1.180 ne ne ne se se se se se sw sw sw sw sw nw nw rrw nw nw nw - ne n n 4.00 24.36 24.36 4.00 24.36 24.36 19.32 10.92 4.00 21.00 24.36 24.36 24.36 4.00 24.36 24.36 24.36 24.36 24.36 2.72 10.92 0.90 33.04 255 43.19 43.19 2.55 31.70 22.27 19.57 11.31 255 24.15 22.27 31.70 2227 2.55 43.19 43.19 43.19 43.19 43.19 0.85 11.31 1.04 0.00 55 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 55 55 51 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 55 6 204 97 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 49 182 130 173 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 57 0 140 0 15 0 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 168 168 125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 168 14 501 0 365 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 151 463 318 10 648 0 0 0 0 0 0 10 0 0 0 0 0 0 0 0 0 0 10 175 0 i I I G D D C F 6 c) AED excursion -17 -63 Envelope loss/gain 533 343 1479 1077 12 a) Infiltration b) Room ventilation 103 0 28 0 263 0 70 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 1 236 0 Subtotal (lines 6 to 13) 636 370 1742 1378 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 16% 20% 0 0 0 636 101 0 0 0 370 76 16% 20% 0 0 0 1742 277 0 0 0 1378 282 Total room load Air required (cfm) 737 32 446 211 2019 89 1660 79 lations to meet all wrightsoft' Right -Suite® Universal 2013 13.0.12 RSU08398 'CC'k S:\PROJECTS ENERGM- MANUAL J1LH-2500-MW.rup Calc = MJ8 Front Door faces: N J 8th Ed. 2017-Apr-05 18:11:C Page i Right-J® Worksheet Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax 954-420-0064 Web: www.lindstromair.com Job: Date: Jun 24, 2016 By: LINDSTROM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BED 4 CABANA 27.0 ft 17.0 ft 10.0 ft heat/cool 10.0 ft heat/cool 15.0 x 12.0 ft 6.0 x 11.0 ft 180.0 ftz 66.0 ftz Ty Construction number U-value (BtutVft2-°F) Or HTM (Btuh/ft2) Area (W) or perimeter (ft) Load Area (ft2) (Btuh) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A-4ocs 1D-h2om ID-h2om 13A-4ocs ID-h2om 1D-h2om 1E-h2fm 11D0 13A-4ocs 108-b 1D-h2om 1 D-h2om ID-h2om 13A flocs 1D 0m 1D-h2om 1 D-h2om ID-h2om ID-h2omd 12B-0bw 11D0 16D-30td 22A-cpm 0.143 0.870 0.870 0.143 0.870 0.870 0.690 0.390 0.143 0.750 0.870 0.870 0.870 0.143 0.870 0.870 0.870 0.870 0.870 0.097 0.390 0.032 1.180 ne ne ne se se se se se sw sw sw sw sw rmv nw nw nw nw nw - ne n n 4.00 24.36 24.36 4.00 24.36 24.36 19.32 10.92 4.00 21.00 24.36 24.36 24.36 4.00 24.36 24.36 24.36 24.36 24.36 2.72 10.92 0.90 33.04 2.55 43.19 43.19 2.55 31.70 22.27 19.57 11.31 255 24.15 22.27 31.70 2227 2.55 43.19 43.19 43.19 43.19 43.19 0.85 11.31 1.04 0.00 150 0 0 0 0 0 0 0 0 0 0 0 0 120 0 15 0 0 0 0 0 180 180 150 0 0 0 0 0 0 0 0 0 0 0 0 105 0 0 0 0 0 0 0 180 27 601 0 0 0 0 0 0 0 0 0 0 0 0 420 0 365 0 0 0 0 0 161 892 382 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 110 0 20 0 0 0 0 0 0 267 60 0 4 648 0 0 0 0 0 0 0 0 0 0 0 187 66 0 66 0 0 0 0 0 0 0 0 90 8 0 0 0 56 0 0 0 0 0 0 0 66 17 0 0 0 0 0 0 0 0 360 420 0 0 0 224 97 0 0 0 0 0 0 59 562 0 0 0 0 0 0 0 j 0 229 483 10 0 0 143 173 0 0 0 0 0 0 69 10 I I I I I I I D FL-D C F 6 c) AED excursion 147 276 Envelope loss/gain 2440 1632 1723 1372 .12 a) Infiltration b) Room ventilation 508 0 136 0 320 0 86 0 13 Internal gains: Occupants @ 230 Appliances/other 1 230 0 0 p 0 Subtotal (lines 6 to 13) 2947 1998 2042 1457, 14 151 Less external load Less transfer Redistribution Subtotal Duct loads 160 20% 0 0 0 2947 469 0 0 0 1998 408 16% 20% 0 0 0 2042 325 0 d d 1457 298 Total room load Air required (cfm) 3416 15.0 24W 115 2367 1041 1755 84 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrightsofC 2017-Apr-05 18:11:09 Right -Suite® Universal 2013 13.0.12 RSU06398 SAPROJECTS ENERGIIA- MANUAL J%LH-2500-MW.rup Calc = MJ8 Front Door faces: N Page 9 I I