Loading...
HomeMy WebLinkAboutEngineering p 6�1 ffo A -SOLAR PV ' SYSTEM IMPROVEMENT FOR:,THEVE PLANS AND ALL PROPOSMD WORK, r a ARE.SUDJCCT TO ANY CORRECT ICN3 d� REQUIRED BY FIELD INSPECTORS THAT MCDANIEL RESIDENCE r,^ryY BE NECESSARY IN OFIsti"'Pi TO COMU LV VA ITI I ALL A.PUCABLE COtES. �a SOLAR IMPROVEMENT CONSTRUCTION DOCUMENTS PROJECT. FOR THE EXISTING RESIDENTIAL GRID TIED ELECTRICAL 00 �w SYSTEM ' 031 ®Y.LUOIL COUNTY OUILDINO DIVISION w a REVIEWED FORCOMPMAN O v REVIEWED BY v DATE w a C v S ANDP F�iSi LL MUST BE KEPT OB OR NO INSPECTION ILL BE MADE u g OOa VICINITY MAP INDEX SHEET DRAWING NAME o CV COVERSHEET t� SLR SOLAR SYSTEM EQUIPMENT LOCATION PLAN DATE 2/20 2016 eASI 9 1F PVR-SS ROOF ATTACHMENT DETAIL-SOLAR ELECTRIC DRAWNSY. ATCHO BY. RF �e SLR2 I ELECTRICAL KINE DIAGRAM WITH CALCULATIONS RECNo.s �� ------APPENDIX-------- scA1E As N p[fi t FSEC CERTIFICATION-SOLAR PV DAAWINGOR� SOLARWORLD 290W MODULE DATA SHEET CV ENPHASES280 MICROINVERTER DATA SHEET a SHEET I OF 4 agg� 1 3� .I Y tl�I l l � 10-10" Ro bnQ 4'-0" 1A � THa n PL mg.AND ALL PROPOS: D g� 4 ARE SUWCCTTO ANY 00fh9EC'ilOf!� �e }1E-OUIrtrO BY FIELD INSPECTORS TIIr;T MAY 6E tIECESSARY IN OALVA TO p� CCL1ryKf WITH ALL Af'"LtCAME 0UMS- 8g� P 8g7 APPROXIMATE LOCATION OF MATERIALS REQUIRED. -FOOT PENETRATION TO 2'.0" (12)SW290 MODULES W/(12)ENPHASE S280 S TRUSS.FLASH PER (6)IRONRIDGE MICROINVERTER MOUNTING KITS(NOTE:EACH o 201 C.SEE SHEET PVR-SS KIT COMES WITH 2 BOLTS) FOR DE S. (8)1 V XRI00 RAIL (4)INTERNAL SPLICE KITS R OR D S 290 (4)GROUNDING STRAPS PROJECT. MODULE TYP. (4)GROUNDING LUGS FOR ARRAY CONNECTIONS OF#6 BARE COPPER (40)WIRE MANAGEMENT CUPS o, (44)IRONRIDGE L-FOOT WITH LAG SCREW u (8)IRONRIDGE END CLAMPS 0 iv IRONRIDGE XRI00 SOLAR RAIL TYP 2 PLCS PER (8)IRONRIDGE END CAPS FOR RAILS w n (26)IRONRIDGE UFO CLAMPS Z Z MODULE ARRAY (12)LANDSCAPE OR PORTRAIT ENPHASE ENGAGE CABLE CONNECTORS p a R FTOP JUNCTION BOX (1)ENPHASE 6 FT EXTENSION CABLE(IF REQUIRED) APP MATE LOCATION (1)ENPHASE END CAPS' J a (1)NEMA 3R RATED ROOF MOUNTED JUNCTION BOXES r FOR WI TRANSITION. c SEE SHEET 2 DISCLAIMER.MATERIALS REQUIRED UST FOR CONCEPTUAL USE ONLY - v THE INTENT IS TO AID CONTRACTOR FOR ORDERING REQUIRED MATERIALS a FOR THE PROJECT.CONTRACTOR RESPONSIBLE TO VERIFY PRIOR TO SOLAR EQUIPMENT ORDERING. N p LL N 0 AP PRO TELOCATION OF N DATE 2/20/2016 9v DISTRIBUTI PANEL LOCATED X INSIDE GAR A • DRAWN BY, lAT # CAD BY. RF �pHp o REC.NO.# �Il HLE' , k� p SCALE G NOTED'.,,�$��+' DRAWING# II SLR 1 SHEET P OF 4 fI II ROOF LAYOUT NOTE: 9 SOLAR PANEL LAYOUT IS CONCEPTUAL,BUT AS PROVIDED,CONFORMS WITH THE REQUIREMENTS SET IN �p SHEET PVR-SS FOR SPECIFIED ADDRESS.CONTRACTOR MAY ADJUST PANEL LOCATION,BUT SHALL �BR RESIDENTIAL ROOF LAYOUT-WIND ZONES- PV MODULE LAYOUT AND EQUIPMENT LOCATION PLAN CONFORM TO THE REQUIREMENTS ON SHEET PVR-SS.SOUD AREAS ON CORNERS OF ROOF ARE WIND ZONE 3 AREAS. SCALE:N.T.S. Ilk 12"ALUR U INTERNAL 9� 39"X 65"PHOTOVOLTAIC ALUM.SOLAR RAIL TYP 2 PLCS PER SPLI PHOTOVOLTAIC MODULE GENERAL NOTES: CE BAR(USSEEWHEN �� Ig I.APPLICABLE CODE.Z014 FLORIDA RESIDENTIAL CODE(5TH EDITION)&ASCE 7.10 MINIMUM DESIGN MODULE P. ARRAY. _ --- -------- _•------'-- SPLICE AT MID-SPAN W/ LOADS FOR BUILDING AND OTHER STRUCTURES. __'['[�:[[[[[[:[['Of[[------[^----------- �J 2,BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2014 FLORIDA BUILDING CODE(5TH I (4)#10.16XJ"ST STL SELF €I< EDITION)REQUIREMENTS.ALL BOLT CAPACITIES ARE BASED ON A SOUTHER YELLOW PINE(SYP) RS TRS TRS TRS TR TRS TRS •'-4--••-•,,,,,;;;;;;;;;;;•::':;;::; V 9-•--- ."......a...°..,."..-+° TAPPING SCREWS TYP EE RESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL ��3 p8 3.ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIENTIAL ROOFS, R� CONSIDERING FROM A 7°TO AMAXIMUM 27°(2/12 TO AMAXIMUM 6/12 PITCH)ROOF IN IRONRIDGE XR1000 OR XR100 #10.16a}"ST STL$ELF TAPPING a SCHEDULE EXISTING RESIDENTIAL ROOF SHALL NOT EXCEED 15'-0°MEAN ROOF HEIGHT. ALUM.SOLAR RAIL TYP SCREW TYP 4 PLCS PER BEAM SPLICE i A.ROOF SEALANTS SHALLCONFORMTOASTMC920 AND ASTM6511,AND 15 THE RESPONSIBILITY TYPICAL SOLAR RAIL BEAM SPLICE DETAIL OF THE CONTRACTOR TO PILOT FILL ALL HOLES. 5.THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY.REFER TO MANUFACTURER MANUAL q FOR ALL ARCHITECTURAL,MECHANICAL,ELECTRICAL,AND SOLAR SPECS. SCALE. 1)j"=1'-0" 6,ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS OTHERWISE NOTED. m $ C F FLANGE CONNECTION$ FASTENED TSTRUCTURAL0 D ROOF OR 7.LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. TYP.2 PLCS,PER SIDE OF MODULE AND BE CONNECTED<25°/OF MODULE LENGTH. L L 8,ALL 39°X 65'PV MODULES MAY BE INSTALLED PER THIS STRUCTURAL CONNECTION DRAWING. LO PRO ILE MO E - -.T 9.ALL SOLAR RAILING AND MODULES SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS. 1 L i 10.CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2014 T USE ANTI-SEIZE AND TI QUE GHTEN TO TOR ° 5 p� FLOR D RESIDENTIAL OD STH EDT OR l GOVERNINGE RPER EFER AN SCHEDULE FTORNS g ULTIMATE WIND ZONE I MAX WIND ZONE 2 MAX WIND ZONE 3 MAX EMBED N REQUIRED EMBEDMENT DEPTH �+ r WIND SPEED SPAN,MAX SPAN,MAX SPAN,MAX DEPTH R• i :I VW(MPH) CANTILEVER CANTILEVER CANTILEVER REQ. iH LABELED U IN THIS DETAIL. li fl ALUMINUM L-FOOT TYP v _ 160 2'-0°O.G,9°O.C. 2'•0°O.G,9°O.G I NOT ALLOWED 3° EVERY ROOF PENETRATION - -SCHEDULE REFLECTS COMPONENTS AND CLADDING(C&C)NOMINAL WIND PRESSURES WITH MAX SPAN,SEE SCH. x q°-16 HEX CAP ST STL EXPOSURE'C',RISK CATEGORY B,ENCLOSED BUILDING AND h<6V-V PER ASCE 7-10 - HIGH PROFILE ODE BOLT AND ST STL 'MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES°AND 2014 F.B.C. SERRATED FIANCE-NUT _ t •LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDES ANY ROOF DECKING THICKNESS. MAX CANT.SEE SCH. ASPHALT SHINGLES ALUM L-FOOT• "CIA ST STL LAG BOLT YP.SEE SCH TYP' c_ /METAL 5V ROOF TYP.FOR MAX SPAN REQ, 2 TYPICAL PHOTOVOLTAIC MODULE ARRAY PLAN 2 PHOTOVOLTAIC END-CLAMP W/} PROJECT, MODULE TYP. 20 HEX CAP ST STL =1-0 VR3 BOLT AND ST STL SCALE:j" ' " ASPHALT SERRATED ELF \)S SHINGLES/ FLANGE-NUT TYP. o S.Y.P.2X4 LOCATE BETWEEN OR XRIDGE XR ALUM. / METAL 5V END•CIAMP SIZE o nn fff OR XR100 ALUM WOOD ROOFING TYP. VARIES. p � CIO�C TRUSSES AND NAIL WITH SOLAR RAIL TYP. SHEATHING p o z 2.16D NAIL PATTERN AT EACH °ST STL LAG BOLT.SEE 3 g c END TO WOOD TRUSS WOOD ROOF SCH FOR EMBED DEPTH ®_ ASPHALT TRUSS TYP. REQ.TYP EACH L-FOOT LL J o DIMENSION DEFINED PER ASCE 7-10 SHALL BE 4 FT REGARDLESS AS PER 2014 FLORIDA SHINGLES/ TYPICAL PV SOLAR RAIL END CONNECTION DETAILr3 ; as RESIDENTIAL CODE 5TH EDITION METAL SV EE U v^ ROOFING TYP. SCALE 1}"=1'•0" VR3 Q N �a ' REFER TO SCHEDULE FOR REQUIRED w Z 3+---_------- 2- -_- „; / EMBEDMENT DEPTH LABELED"X"IN -----------2 -------,• 3 (/)I THIS DETAIL. O 1 i i ALUMINUM L-FOOT egg GABLE END BUILDING 1 HIP END BUILDING ROOF I + d a u a a� Be TYP EVERY ROOF �T95 ROOF WIND AREA ZONES WIND AREA ZONES ''OI 2 /' _ PENETRATION I i�' , �, DATE 2-20-2017 gX - -- "-16 HEX CAP ST STL BOLT - ------r--------- --- -- � � i ; ..-•' AND ST STL SERRATED DRAWN BY. ]AT 3 2 2 FLANGE NUT TYP. �" R' aKDeY: Lai SCALE AS NOTED g 17 L L ` •= CENTER-CLAMP WITH B D2,1 I I I 2X PT S.Y.P.WOOD 1 �, }"-20 HEX CAP ST ��8 I / DRAWING I � � 0`�� ` �� UNISTRUT CONT.AL 0 E d..% I 11Q __ _ __ STL BOLT AND(1)ST \ OD W$TNUT-LL-THRD STL SERRATED �� �} Y ITS i `. �.�'�� / MODULE TYP.. �\ 1 `�^ 1 + ' ALL NUTS TYPWASHERS- . IRONRIDGE XR1000 ASPHALT FLANGE NUT TYP. 31 2 2 3 L3' aR SHINGLES 2 2 FRONT SIDE BEAK�PLI ALL CONNECTIONS XR ALUM. METAL 5V LOCATION.SEE rt DETAIL 0 8 • / SO SOLAR RAIL TYP. VR3 . VR3 WOOD ROOFING j"ST STL LAG BOLT.SLESCH/ p Wool) ROOF TYP' FOR D,DEPTH REQ YPO TYPICAL PHOTO LTA) RRAY PITCHED ROOF ; SHEATHING TRUSS TYP. EACH L-F-FOOT �7o LAYOUT-WIND ZONES-SCHEDULE-PLAN ('T-), OPTIONAL SPANNER CONNECTION DETAILS TYPICAL PV SOLAR RAIL MID CONNECTION DETAIL` SCALE NONE VR3 SCALE: 1 "=1'0" SCALE: 1 ^=1'•0" r R POWER TABLE: SYSTEM GENERAL PHOTOVOLTAIC 3-LINE DIAGRAM SPECIFIC FLAG NOTES: DC-SIDE A B C 1ST BRNCH AC-SIDE OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES ZL PRIOR TO THE COMMENCEMENT OF WORK LABEL BREAKER PER NEC 690.54,705.12(D)AND 705.10. Q #PV MODULE I 1 12 INVERTER �o b il MANUF SOLAR WORLD ENPKASE.S2804G EQUIPMENT SHALL BE INSTALLED PER THE 2011 NATIONAL ELECTRICAL PV BACKFEED CURRENT PLUS MAIN BREAKER RATING MUST BE LESS THAN OR �g@ CODE(NEC),ALL'APPUCABLE OR GOVERNING CODES,MANUFACTURER 7 EQUAL TO 120%OF MAIN SERVICE BUS RATING AND BREAKERS MUST BE " MODEL 90 Wp- 270 W 3240 W PEAK POWER Q ➢ REQUIREMENTS OF AND PER THE GOVERNING UTILITY COMPANY. MOUNTED AT OPPOSITE END OF MAIN BREAKER PER NEC 705.12. ' POWER 290 Wp•dc 270 W 3240 W CONT.POWER VOC 39.9 VDC 240 VAC 240 VAC VOLTAGE U B1 STIN AGENT NAME AND NUMBER SHALL BE INDICATED PER NEC Q ENPHASE TRUNK CABLE SHALL BE KEPT�°ABOVE ROOF SURFACE MINIMUM D s �� ISC 9.97A 1.13A 13.56A CURRENT �n VMP 31.4 VDC 60 HZ 60 HZ FREQUENCY TO PREVENT AN INCREASE IN AC VOLTAGE LEVEL AND AVOID ANY ) NUISANCE FAULTS,IT IS RECOMMENDED TO SIZE CONDUCTOR FOR A � IMP 9.33 AMP TOTAL VOLTAGE DROP OF 2%OR LESS PER INVERTER MANUFACTURER. �➢ "STC:CELL TEMPERATURE @ 25°C,SPECTRUM A 1.5,IRRADIANCE @ 1000 W M2 ALABEL DEVICE PER NEC 690.14(CI(2),AND SECURE PER NEC 6907(D), spa LE A .B ENPHASE DROP CABLE SYSTEM (12)MODULE BRANCH CIRCUIT•SEE POWER TABLE ABOVE C INVERTER OUTPUT CIRCUIT E OP T +�OUTDOOR CONDITIONS#10 AWG,INSULATION,THHN/THWN-2 •� _ C ��(1)#10 AWG,GROUND CONDUCTOR -' SYSTEM A CONDUIT SIZE,ej°MINIMUM _ INDOOR CONDITIONS ONLY PROJECT, (3)#10 AWG W/(1)#10 GROUND NM ROMEX CABLE,OF CABLE OR ENPHASE 52B0 EQUIVALENT — S = — EQUIVALENT LJ MICROINVERTER TYP.�'"' LENGTH OF RUN^SOFT oa TERMINATOR CAP INSTALLED U ON END OF ENPHASE ENGAGE Ll 100 AMP AWN SERVICE U LaN., CABLE SYSTEM Z� L2 PANEL(MIN-FIELD VERIFY) 2s d In N o ENPHASE ENGAGE CABLE SYSTEM ENPHASE ENGAGE CABLE SYSTEM G w AWG SOLID CU EQUIPMENT GROUNDING CONDUCTOR CONT RUN TO GROUNDING LUG ON Ed m Q JUNCTION BOX Z N RAILS.MODULES GROUNDED TO MAILS WITH IRONRIDGE INTEGRATED GROUNDING SYSTEM, NEMA 3R ¢CD. ENCLOSURE IOOA 0 SINCE MICROINVERTERS ARE GRID-INTERACTIVELY ONLY MAINN CJ BREAKER BREAKER DOES NOT HAVE (MIN) TO BE LOCKABLE(SEE 690.1 OE) La7N Q LL 20A/2P N G e R g o N � o° o DATE 2/20/2016 �K e 0 o DRAWN BY, AT I ➢ CHKD BY, RF gR➢ REC.NO.# � NEC 2011 LABELING REQUIREMENTS SCALE AS NOTED DRAWING# % WARNING PHOTOVOLTAIC AC DISCONNECT ELECTRIC SHOCK HAZARD. DO NOT TOUCH MAIN PVSYSTEM TERMINALS.TERMINALS ONBOTH THE LINE WARNING @ MAXIMUM AC OPERATING CURRENT: 13.56A AND LOAD SIDES MAY BE ENERGIZED IN THE DUAL POWER SOURCE TO EXISTING SHEET 4 OF a 8pL1 MAXIMUM AC OPERATING VOLTAGE: 240V OPEN POSITION GROUNDING @ (PER NEC 690.54-PROVIDE AT EXTERNAL AC DISCONNECT LABEL PER NEC 690.17-PROVIDE AT MAIN SERVICE PANEL SECOND.SOURCE IS PV SYSTEM ELECTRODE TF9s.5Lc PUN 1)ALL PRO11101 5'.0 IAVRK 40� DISCONNECT ORMAABLE)I[EPANELIF PER NEC690.1412)•PROVIDEATMAIN PHOTOVOLTAIC SYSTEM ARE SUHJGCTTOAtJYCORfi ,iIOP15 APPLICABLEI SERVICE PANEL CIRCUIT IS BACKFED WARNING LABEL PERNECUIT ID)(4)-PRKFEDTMAIN REQUIRED SYFIELD INSPECTORS THA INVERTEROUTPUTEISOVER NECTION-DO NOT SERVICE PANEL frIAY BE NECESSARY IN OR 'Pt TO yyei RELOCATE THIS OVERCURRENT DEVICE p ./ �L �L ` qq@6es . LABELPER NECTUS.121D)191-PR-MATMA,N SERVICE PANEL COTAPU 1^ATM ALL APPLICA''a-1 TPCEXES tlI�