HomeMy WebLinkAboutProduct Approval (2) 7 s ' t4 s+zH
w t
a
BCIS Home Log In User Registration Hot Topics 1 Submit Surcharge Stats&Facts Pubiita + IS i e Links 'Search }
Florida '
Product Approval �� ?
USER:Public User
i
Product Approval Menu>Product or Aoplication Search>implication List>Application Detail
FL# FL19621
r Application Type New
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Sunlast Metal
Address/Phone/Email 2120 SW Poma Drive
k Palm City, FL 34990
a (772) 223-4055
flvalidation@yahoo.com
� � 4
� 'as Authorized Signature Terry Kapron
flvalidation@yahoo.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report- Hardcopy Received
� J
¢ Florida Engineer or Architect Name who developed Locke Bowden
' the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 03/02/2026
41, Validated By Zachary R. Priest, P.E.
- b ✓i Validation Checklist- Hardcopy Received
€ v Certificate of Independence FL19621 RO_COI_FL 17701 Sunlast Metal ssr.pdf
Referenced Standard and Year(of Standard) Standard Year
TAS 100 1995
� = a
g} TAS 125 2000
{. TAS 125 2003
Equivalence of Product Standards
Certified By
r� ,h x ,,,.�a,r Sections from the Code
§ Product Approval Method Method 1 Option D
Date Submitted 12/18/2015
Date Validated 12/18/201S
Date Pending FBC'Approval 12/21/201S
r'
Date Approved 02/10/2016
Summa Hof Produces---------------
FL#� Model .Number or,Name Descriptions'
G {
ge
Ndt
..,,.;
;(g 19621.1 "Key West Series" S-V Crimp-HVHZ 26 GA. HVHZ 24"Width
� fq ��: Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL19621 RO_II_FL 17701 Sunlast Metal ssr.pdf
01 Approved for use outside HVHZ:Yes Verified By: Locke Bowden, P.E. #49704
s ry` Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +n/a/-189.25 Evaluation Reports
Other: -78.5psf @ 16" o.c. -189.25psf @ 8"o.c. Install per FL19621 RO_AE FL 17701 Sunlast Metal_ssr.pdf
manufacturer instructions and PAS 133 in compliance with Created by Independent Third Party: Yes
FBC 2014 For HVHZ use
01
ni Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Coo right 2007-2013 State of Florida. ::Privacy Statement::Accessibility Statement::Refund Statement
�p
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public records request,do not send
( electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.1*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are la licensee under
rq Chapter 455,F.S.,please click here.
Product Approval Accepts:
® E9
4'az
Credit Card
Safe.;
� �r I
i
I
I
AA
rq
Locke Bowden,P.E. � � ;'
9450 Alysbury Place
Montgomery,AL 36117
Manufacturer:Sunlast Metal,Inc. FL 17701
2120 SW Poma Drive
Palm City,FL 34990
Code Compliance: Florida Building Code 2014
Rule#61G20-3
Category: Roofing
Sub-Category Metal Roofing HVHZ
"Key West Series"
Product:5V Crimp Metal Roof Panel
Support Substrate: 15/32"APA Wood Deck min. over supports at 24"spacing maximum
Material 26GA steel Yield Strength 55ksi min. Corrosion resistant: Material to comply with FBC
section 1517.6 for HVHZ (Design of support system not included in this report)
Panel Dimensions:Thickness-26GA steel Width: 24" Rib Height: 5/8" High rib: 12"o.c
Slope:.2/12 min.or greater in compliance with FBC 2014;Section 1515.2
Underlayment: In conformance to FBC 2014.
Fire Classification: Not within the scope of this report.
Fastener:Corrosion resistant#10-1-1/2" (3/16"min. penetration through support;Wood-Zac
XG Fastener, Hex Head w/Neoprene washer fastener or equivalent In compliance with FBC
Section 1506.6 and 1507.4.4
Insulation: Optional-Rigid insulation board,3" max thickness compliant with FBC 2014 Section
1508.2
Installation:Install per manufactures details and RAS 133
Design Uplift Pressure:Table A
Roof Areas Field Perimeters and Corners ,
Max. Design Pressure -78.5 psf -189.25 psf
Fastener Spacing 16" o.c. 8"O.C.
t Fastener Size #10 #10
*Maximum Design Pressures include 2:1 Safety Factor
Quality Assurance: In accordance with FBC 2014 and Rule#61G20-3:Keystone Certification,
Inc. QUA 1824
Code Compliance demonstrated: Florida Building Code 2014 Section 15.23.6.5.2.4.1
This report is limited to compliance with the structural wind load requirements of the FBC 2014.
Required wind loads shall be determined per project per FBC 2014 and any rational analysis
computation shall be prepared by a licensed design professional.
Reference Data: J
Architectural Testing Inc(TST 1527) #F0755.01-450-18 TAS 125-2003
Architectural Testing Inc(TST 1527) #0412-1017-05 TAS 125-2003
Architectural Testing Inc. (TST 1527) #SFMS-001-02-01 TAS 100-1995
PRI Construction Material Tech nologies(TST5878)AKZC-001-02-01/05 TAS 110-2000
PRI Construction Material Technologies(TST5878)AKZC-001-02-01/05 ASTM B 117-2002
AKZO Nobel Coatings, Inc. Lab Form ASTM G 153
I
• y�� � `.. .e� si
!l,
4 Locke Bowden,P.E. y� � •
9450 Alysbury Place
Montgomery,AL 36117
Manufacturer:Sunlast Metal,Inc. FL 17701
2120 SW Poma Drive
Palm City,FL 34990
Certificate of Independence
Locke Bowden,P.E.does not have,not will acquire financial interest in any company manufacturing or
distributing products under this evaluation.
Locke Bowden,PZ is not owned,operated or controlled by any company manufacturing or
distributing products under this report.
I
Install Detail
TYPICAL ASSEMBLY PROFILE VIEW Fastener:#10-1-1/2"WoodZac XG
Perimeter/Corner fastener spacing 8"o-c Field fastener spacing 16"o.c.
14.v L $os. lVI
L&ke6m4en.,P.E.
M`
FI` €204 STATE OF
I
i
� I