HomeMy WebLinkAboutProduct Approval RECEIV7D EFB Q 8 2017
{. �� ' r 7 r✓ ,�.- d .o'N{ ut"g �.�5-�-rFi 1 , { &r'r7§rt �l;r�"" .. •7
^a`�y' 1''�L`�+� "`s'$n '{�� —
f'/} A {{F`t &. 't-c" s(I`t t�„'�i�"�-��' itbn' ,„ta f� f' �.i f 5`t2 �?f�a Y -•- -�
���k 1 r A.Ft ! �t.��.',x� 4x a<i L�` .j � i �t�.��' r 5 ��'�c i.3�� `tr > F �,-•�``y .--fit
� *r �5'^ ..y �'• r a'a'+7 tit .µ r.:.,.'"5..r f { a�s,,.3-:.a,sae a E r y ry +'•.�T
iSl.� rs6av i._5"�s�ib;C h,+�• S�`,v...;..
BCIS Home Log In j User Registration j Hot Topics Submit Surcharge I Stats&Facts Publications FSC Staff + BCIS Site Map UnX5 Search
l:i•�t i�t('i III .
d, {; Product Approval I
` lt'" USER:Public User
.Y. >(r•tSyn�1y x�v�l t.gnu>Product or nm:hntion 5+•arct,'+Anolic�>Application Detail
FL# FL17443 Ca�+y ®ATTACHMENTS
gqp {��` `�
Application Type New COKEW FAS IEM OR AT ACf101 ENTS
Code Version 2014 AR Tilt;8�16AL MI "of THE
Application Status Approved fYIF Iflf:f1&alPldtet7l®16�11 ��1
w Mao
Comments
Archived
Product Manufacturer J A TAYLOR ROOFING TES PLANS AND ALL PROPOSE WORK
Address/Phone/Email 302 Melton Drive i ARESUBJECT TO ANY CORRECTIONS
FT PIERCE, FL 34482
(772)466-4040 REQUIRED BY FIELD INSPECT S THAT
kylewhite228@aoi.com dnAgq PE NECESSARY�B QhDEKTO
Authorized Signature Kyle Taylor Yf)nal�®3Yg9 �0�A � e'EYAI �tlL� R�O�SI,
kylewhite228@aol.com
Technical Representative ��1�/v'�/ v
Address/Phone/Email ST.LI1L� rOU7r! BiJIT?�T�'?C?'r1VISION
REVIENVED FOR LIANCE
Quality Assurance Representative IdE EAVED Yr/
Address/Phone/Email
DATE e� y r
PLANS AND PERMIT MUST BE KEPT ON JOB
Category Roofing OR NO INSPECTION WILL BE�IAFiE.
Subcategory Metal Roofing
I
Compliance Method. Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
r; Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Locke Bowden
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/11/2021
Validated By Hermes F. Norero, P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence FI 17443 RO Cn1 Certif ute of Indeoend Locke Bowden P E pdf
Referenced Standard and Year(of Standard) ;standard Year
UL580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
I
Product Approval Method Method 1 Option D
I
7
r
t e '
Date Submitted 03/02/2015 ;
Date Validated 03/02/2015 t
Date Pending FBC Approval 03/05/2015
Date Approved 04/15/2015 .`
Summary of Products
FL# Model, Number or Name Description
17443.1 5 V Crimp +26GA 1/2" rib height over 15/32" plywood
Limits of Use Installation Instructions �W
Approved for use in HVHZ: No FL17443 RO IT 5 V C•imD FasteninQ.Dg.1aj.Upjf
Approved for use outside HVHZ:Yes Verified By: PRI Construction Materials Technologies,LLC
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-129.25 Evaluation Reports
other:-129.25 @ 6"o.c. -69.25 @16" o.c. margin of safety FL17443 RO AF FL 17443 1. A.Taytor Roofing V Came
2:1 wlth 24"max. coverage Install per manufacturers detail, &P- rt-5s.ridf
Not for use in HVHZ. Created by Independent Third Party: Yes
fr:rrb Tk��e
Contact Us::7601 Blair Stone Road.Tallahassee Fl,37399 Phone-850-487-1824
i
The State of Florida is an AA/EEO employer.goDvright 2007-2013 State of Florida. ::privacy Statement::Accessibility Statement::mound State`ment
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 4S5,F.S.must provide the Department with an email address if they have
one.The emalis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine:if you are a licensee under Chapter
455,F.S.,please dick here. j
Product Approval Accepts:
® aCtccl
Credit Card
safe
,i
I
i
I
i
i
I i
t e
t'a j
Locke Bowden, P.E.
9450 Alysbury Place
Montgomery,AL 36117 FL# 17443
,I A'Taylor Roofing Inc
302 Melton Drive
Fort Pierce,FL 34982
Product:
5 V Crimp thru Fastened 1/2" rib at each panel edge and one in the center of the panel,24" net coverag ,
26GA min. over inin.15/32"thick CDX plywood decks.
Compliance: Florida Building Cede (FBC)2014; Section 1504.3.2, Section 1507.2.8, Section 1507.4.3
UL580—rests for Uplift Resistance"
Description: Architectural metal roof panel,26 gauge metal panels; over min. 15/32"CDX plywood
and shall comply with Florida Building Code 2014, Section 1507.4.3
Installation: Install per manufacturers install details in accordance with FBC 2014, Section 1507.4.2
Deck Slope 2:12 or greater and shall be compliant with Florida Building Code 2014, Section 1507.4.2.
Design Pressure: -129.25 psf @ 6"o.c. and-69.25psf @ 16"o.c.; Fasten along the crown of the rib in the
center of panel and along the lap. Design pressure includes safety factor=2.0. First fastener to be within 3"
of panel edges. Min. 8d x 2"annular ring shank nails spaced 6" o.c. reroofing,with less than 19/32"plywood
9min. 15/32"), this attachment is to be used in addition to existing attachment. Deck attachment to be by j
other design professional.
Underlayment: approved product in compliance with FBC 2014, Section 1507.2.8
I
Thru-fastened over min.15/32"plywood
Fasteners: #9-15 FIWII corrosion resistant fasteners with sealing washers, metal to wood connections with
fastener length to penetrate 5/16"through substrate per Florida Building Code 2014, Section 1507.4.4
Conditions of Use:Not for use in HVHZ. Install per manufacturer's instructions and must be designed I
In compliance with Florida Building Code 2014. Manufacturer is compliant with Rule 61G20-3; wherein
manufacturer complies under a quality assurance program audited by approved
Quality Assurance Entity; Keystone Certifications valid thru 4/11/2021
Evidence Submitted:
a. UL 580/TAS 125 Tests for Uplift Resistance
b. Reference-Test Report 0224-0501-06 Hurricane Test Laborattor; ,e t t s r,sr
�4
C. Test equivalencystandard—the UL 580-94 test standard is c uiX. of 0-06
d. Quality Assurance Procedures and Documentation •� G�a`� NS °
, z�J
G�
'o; STAT
LC.
� ,, 2j
This eeport dues not guarantee or warrnntylany product validated or installed.vianufacturvr's warranty applies. l
I
5 V Crimp
Fastener-#9-15 corrosion resistant w/sealing washers
24"coverage
f
i
Fastener: #9 x 15 corrosion resistant with sealing washers
in Compliance with 2014 Florida Building Code, Section 1507.4.4
Perimeter fastening: 6"o.c.
Main Field fastening12"o.c.
Panel Width: 26"
Panel Coverage: 24"maximum
26 GA Architectural Metal Roof panel '
i
I
i
i
4