HomeMy WebLinkAboutEngineering T reasure Harvey E.K n 7205 Elyse Circle
C oast Professional Engineer#32831 P 5 L Florida 34952-82 a
B uilding Architect#AR0009471 PHONE(772)466-5509
035
i Inc. E-MA
IL:hkoehnen@tcbeweb.com
Certified General Contractor#CGCO24776 (772)IL:hko 9 3en@tcbeweb.com MAR o 2017
pGDRai�-Tli��
St._'Acie County, FL
Contractor 'fl R�P5_ Vj L1)Ds
Owner g.Ct D 49Lf A Date
Job Address 1 8 ��LIZ- 'Pre.. 61b" _
METAL ROOFINU4.,. 'e t>- 4PT GV •D�� �12"'v
NEW ROOF RE-ROOF X REPAIR AREA. I LE C(j
METAL ROOF PLAN
1�
`gyp,
I I I I I I I I
N T tiZ
* Re no,.e e tW ug to .
an lim
b. 13 I'd,am ful a
3 ce 6' o. .a
ASCE 7-10&FBC 2014 5th Edition ENCLOSED BLDG SEMI ENCLOSED BLDG OPEN 4
PART 2 LOW RISE C&C SIMPLIFIED b E
RISK CAT 2/V= ��D/EXPOSU_RE C A— �� Kzt=1.0/hJ 3 /12 PITCH = N
—� ——�
ROOFSYSTEM 5V
ZONE IP@ @ h=30 = X = PSFx0.6= 30�`l
ZONE 2P@ @ h=30 = X = PSFx0.6=.r r�- a= �jrW6b c" _r
ZONE3P@ @ h=30 = X = PSFx0.6=� g a= Y.
MAX DESIGN PRESSURE PER NOA ��•`�`7T— �,
DECKTYPE IPL7' ytN��Q THICKNESS
BASE SHEET'C�I.� Pc•�S NO.OF PLIES i FASTENERTYPE SPACING t vHiz1 N15
PLY SHEET NO.OF PLIES - FASTENERTYPE SPACING "
TOP PLY NO.OF PLIES^ FASTENERTYPE SPACING
INSULATION BASE LAYER TYPE
TYPE OF FASTENERS: SPACING I SIZE
FIELD PERIMETER CORNERS �571 k/V
INSULATION TOP LAYER TYPE — SIZE
TYPE OF FASTENERS/OR BONDING MATERIAL \
DRIP EDGESIZE 3 X 2�'" DRIP MATERIAL 3Z A-4.0 r4 FLASH ING MATERIAL .G'-3Z
NELS: FIEL6
FASTENER SPACING FOR METAL ROOF PA PERIMETER��(L.
CORNER
T reasure ffrvey E. Koehnen
` C Oast Professional Engineer#32831
B uilding Architect#AR0009471
E ngineers, Certified General Contractor#CGCO24776
Inc.
'these`fables Are For Roof Coverings _ - _-
Roof coverings Installed on Buildings with a
Mean Roof Helght of 30,or Less Located in Exposures B,C or D
'la6(e R301.2[2]_Qtz Pt,ju a;�)..S-!45cE5 7-lt�
(OMPONENTS AND CLAODING WORST CASE DESIGN PREsSURI; fPSP].
160 Exp B 160 Exp C 160 Exp C 160 Exp D 160 Exp D
(One story . (Two story`) (One story) (Two story-A)
Roof>0 to 7 degrees Zone 1 -27.6 -33.4 -38.7 -40.6 -45.9
7degrees=11/2/12 pitch Zone 2 -46.4 -56,2 -65.0 -68.3 -77.1
Zone 3 -69.8 . -84.5 -97.7 -102.7 -115.9
Roof 5 7 to 27 degrees 'Zone 1 -26.3 -30,7 -35.5 -=37.2 -42
27 degrees=6/1z pitch Zone 2 -44.1 -63.4 -61.8 -64.9 -73.3
Zone 3 -65.1 -78.8 -91.2 -95.7 - 10s-;)
Roof 5 27 to 45 degrees Lone 1 -27.8 -33.7 -40.0 -40.1 -418;2
^5 deoreics= 12112 nj Cn Tons 2 -32.1 39.3 .A =7. -5°.3
Lone -3 - �22.4 -39.3 1v - 7,7 ^53.0
150 Exp B 150 Exp C 150 Exp C 150 Exp D 160 Up D
(one story)(two story*) (one story=) (two story.)
Roof>0 to 7 degrees zone 1 -24.3 -29.6 -34.1 -35.8 -40.4
7degree8=1112/12 pitch Zone 2 -40A -49A -57.2 -60.0 -67.8
Zone 3 -61.4 -74.3 -88.0 -90.3 -102.0
Roof>7 to 27 degrees Zone 1 -22.2 -26.9 -31'.1 -32.7 -36.9
27 degrees�_6/12 pitch Zone 2 -38.7 -46.0 -54.2 -66.9 -84.3
Zone 3 -•67,3 -69.4 -80.3 -84.3 -95.2
Roof>27 to 45 degrees Zone 1 -24.3 =29.5 -34.1 -85.8 -40.4
45 degrees=12/12 pitch Zone 2 -28.4 -34,4 -39.8 -41.8 -47.2
Zone 3 -28A -34.4 9.8 -41.8 -47.2
One story*=one story building with a maximum mean roof height of 15 feet
TWO star'y"=two story building with e maXIMUrn mean roof height of 30 feet
•If-allbwed by the Mlarni Dade N.O.A or Florida Product Approval•,any system-that does.-not meet the
MIMMum components and cladding pressures for the area that the building Is located per this form
may require a Florida licensed engineer to revise the fastener spacing
T C B E,Inc. 7205 Elyse Circle PHONE (772)466-5509
Port Saint Lucie FAX (772)489-3035
Florida 34952-8212 E MAIL hkoehnen@tcbeweb.com
WEB 517E http://www.tr-beweb.com