Loading...
HomeMy WebLinkAboutEngineering PLAN VIEW W . W . B N INSTALL (4) NEW 5 O 0 PILINGS W/ k?K BOATLIFT :AT EXISTING DOCK P/L P/L I 12' 1 COP I1.4 DOI LE' I I .• I I O I I I ARE SUBJECT TO ANY COMSC T ION I --�I + `Ill QUIRE"D BY FIELD INSPECTORS THAT I B/L MM EE NECESSARY IN 00M TO I C01-PIPMAJITH ALL APPL! ABLE CuM& I I I I I I � O EXISTING DOCK I STRUCTURE I 12' 12 ' x22 ' I I I I I ii 77 yL=: :-:-:-:-: I : .::::::: .:-:::::::::::::....:::::... I 34T :&,16� o ® UPLAND AREA FBC 2014 5TH ADD. WIND ST.LL Cou PROTOCOL BUILDING DIVISION REVIEWED CONSTRUCTION: WOOD FRAME STRUCTURE : OPEN FOR COMPLIA WIND SPEED : 3 SEC GUST, 170 M.P.H REVIEWED IMPORTANCE FACTOR : 1 EXPOSURE DATE o FRAME FLOOR : 40 PSF LIVE LOAD LANS AN PE IT 10 PSF DEAD LOAD COMPONENT AND CLADING: MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE DESIGN Casey Marine Constructio Imbordino DRAWN 5912 Pinetree Drive 1247 NETTES BLVD. CHECKED Ft.pierce, Fl 34982 JENSEN BCH. , FL 34957 DATE STRUCTUAL VIE* MOORING AREA 12' INSTALL (4)8" _ PILINGS JETTED AND FINISH WITH DROP HAMMER BOAT LIFT MARINE GRD.2.5 C.C.A 4811_7211 AREA ABOVE 9K BOATLIFT DECK EXISTING . . . F LE CoPlf'. DOCK fF 0 o M.H.W M.L.W 6' 4 ' SEA FLOOR 10'-12' MIN. PENETRATION DESIGN asey marine Imbordino DRAWN Construction 1247 Nettles Blvd CHECKED 5912 Pinetree Drive Jensen Beach, Fl DATE Ft . Pierce, F1 34982 34957 ENGINEERING REVIEW. BOAT LIFT TOP CARRIER BEAMS AND NOTE TO EXAMINER: MOUNTING BRACKETS COMPLY WITH WIND THIS CERTIFIED ENGINEERED LOAD REQUIREMENTS OF THE 2014 FLORIDA G DRAWING HAS BEEN PREPARED BUILDING CODE, PER ASCE 7, AND PER SPECIFICALLY FOR USE ONLY BY DESIGN LOAD REQUIREMENTS OF THE 2010 ALUMINUM ASSOCIATIONS DESIGN MANUAL. BEAMS AND MOUNTING BRACKETS " INSTALLED PER HI-77DE 1NS7RUC77ONS, WILL ooc00000°no°°°°poOc EXCEED ULTIMATE DESIGN WIND SPEED OF- °oo°° M e °O000 170 MPH (EXPOSURE CATEGORY C OR D) `'? - °° O fG ` C E N q 9 °o°° BOATS LIFTS PRIOR T O A MAJOR WIND EVENT. q � NO.43M o o ° o 0 0 o A R dSE MAR 27 2 17 0 o STATE OF �o` • o A,PILIN o PILING PENETRATION TO BE 10' 0%0 °o°°t�'&8 O R 1 0 �000 INTO THE SAND BOTTOM OR 5' • °OO°°o0O N°Ao p0 oo°° INTO ROCK STRATA, SUB-SURFACE CONDITIONS CAN VARY GREATLY, THE CONTRACTOR SHALL VERIFY ALL PILE CAPACITIES TO COMPLY WITH FBC 2014. ALL PILINGS TO BE ROGER BASER AE NO. 8" MINIMUM DIAMETER MCR PROFESSIONAL3855 ENGINEERING 2.5 C.C.A PRESSURE TREATED C.A. NO. 26967 WOOD, PRE—STRESSED CONCRETE 1014 NW PINELAKE DR. OR COMPARABLE EQUIVALENT. STUART, FL 34994 t • PILING MOUNTING TABS • MINIMUM (2) 3/8" DIA. SS LAG BOLTS FOR WOOD PILING OR SS CONCRETE ANCHORS FOR ELECTRICAL REVIEW. CONCRETE PILINGS PER PILING 112 HP ELECTRIC MOTOR REQUIRED.MINIMUM (2) 3/8" 8.8 AMPS ® 115V EACH DIA. SS CARRIAGE BOLT FOR 4.4 AMPS ®230V EACH ATTACHING MOUNTING TAB TO QUANTITY- 2 LIFT REQUIRED PER PILING. TOTAL WATTS.• 2024 MOUNTING TAB CONSTRUCTED FROM 1/4" X 2" ALUMINUM 6061 - T6 FLAT BAR . /2 PlC CfRAE PClES + ry 4 9 S w WARE + a uu�waaa ar cws�leo•aao warts a LF7M"EA" 9,000 LB. CODA GEAR nn BOAR/FTS AND MAR/NE PRODUCTS wo CARRE?rAes E srm e /„/DO�QX 4050 SEL VI TZ ROAD "f"°' ,Y BOAT LIFT LLLIIILLLffI s r W���r ' FORT PIERCE, FL 34981 ALWOIUL s � J I+ X :SAC Ja4 + i ae�wC�l a X a R. HYDE SCALE. NIS DATE. 911116 REV. 1 1-800-544-0735 www.hi-tide.com nrsazPncw