SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to
be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section(in Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right
to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: TRI-BUILT Sand-R SA Shingle,Smooth HT S/A and S/A HT TU Underlayment Products
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be
done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 5. t no'-3- ()JOL.t
The submitted documentation was reviewed by Gaspar J Rodriguez. ST.LITCW COL—,qT-V Btm-PPJC-DMISION
� --
p pVLF�WED FOR C Ud CE
_
DATE,
PLANS ALNRP�EIT NRUST RE IaPT ON JOB
or,NO EXSPECTIOIN NVILL Ag
NOA No.: 15-1123.06
Expiration Date: 09/29/20
Approval Date: 04/28/16
Page 1 of 5
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayment
Materials: SBS
SCOPE:
This acceptance is for TRI-BUILT Sand-R SA Shingle,Smooth HT S/A and S/A HT TU Underlayment Products,
as described in this Notice of Acceptance,for use with approved prepared roof assemblies as described in this Notice
of Acceptance; designed to comply with the Florida Building Code,including the High Velocity Hurricane Zone of the
Florida Building Code.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specification Description
Tri-Built Sand-R SA Shingle 36"x 65'rolls ASTM D1970 Self-adhering glass fleece reinforced, SBS
Underlayment modified bitumen roofing underlayment.
Manufacturing Location #1-3
Tri-Built Smooth HT S/A 36"x 65'rolls ASTM D1970 Self-adhering glass fleece reinforced,
Underlayment elastomeric bitumen roofing underlayment.
Manufacturing Location #1-3
Tri-Built S/A HT TU 39 3/8"x 65 3/5, TAS 103 and Self-adhering glass fleece reinforced, SBS
Underlayment rolls ASTM D 1970 modified bitumen roofing underlayment.
Manufacturing Location #3
MANUFACTURING LOCATION:
1. Drummondville,Quebec(Canada)
2. Wadsworth, OH
3. Gulport,MS
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Underwriters Laboratories,Inc. R21824 UL790 09/11/15
Trinity I ERD S40540.02.13-1 ASTM D1970 02/19/13
S40540.11.13 ASTM D1970 11/19/13
S43530.02.14-1-R1 TAS 103 05/14/14
S44870.04.14-4 ASTM D1970 04/10/14
S44870.04.14-1 ASTM D1970 04/10/14
S44870.04.14-3 ASTM D1970 04/02/14
S40540.10.14 ASTM D1970 10/31/14
SOPC-SC8520.04.15 TAS 103 04/27/15
NOA No.: 15-1123.06
t 1UALEC13UNTY
Expiration Date: 09/29/20
Approval Date: 04/28/16
Page 2 of 5
! !
APPROVED ASSEMBLIES:
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(1): Base sheet mechanically fastened,membrane adhered.
Base Sheet: One or more plies of ASTM D226 Type 11 or ASTM D2626 with a minimum 4" side lap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and
two staggered rows 12" o.c. the field of the roll.
Membrane: One ply of Tri-Built S/A HT TU Underlayment,Tri-Built Smooth HT S/A Underlayment
or Tri-Built Sand-R SA Shingle Underlayment with minimum 3-inch side laps and 6-inch
end laps. Starting at the first course,parallel to the eave, align the membrane carefully by
completely unrolling and setting it exactly where it will be installed. Once aligned,rewind one
half of the length. Gently score the release paper on the high side of this roll, ensuring not to
cut through the membrane's thickness. Unroll this first half by evenly peeling back the release
paper while simultaneously and slowly pushing out the membrane. Repeat process for
remaining one half of the length. Once installed,the membrane must be pressure rolled with a
metal or rubber roller. Pressure shall be applied over the entire surface,paying particular
attention to all side and end laps.
Surfacing: Approved for Mechanically Fastened Metal Roofing,Wood Shake&Shingles,Asphalt
Shingles, Slate, Simulated Slate.
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Base sheet mechanically fastened,membrane adhered.
Base Sheet: One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4" side lap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and
two staggered rows 12" o.c. the field of the roll.
Membrane: One ply of Tri-Built S/A HT TU Underlayment with minimum 3-inch side laps and 6-inch
end laps. Starting at the first course,parallel to the eave, align the membrane carefully by
completely unrolling and setting it exactly where it will be installed. Once aligned,rewind one
half of the length. Gently score the release paper on the high side of this roll, ensuring not to
cut through the membrane's thickness. Unroll this first half by evenly peeling back the release
paper while simultaneously and slowly pushing out the membrane. Repeat process for
remaining one half of the length. Once installed, the membrane must be pressure rolled with a
metal or rubber roller. Pressure shall be applied over the entire surface,paying particular
attention to all side and end laps.
The Tri-Built S/A HT TU Underlayment shall be back nailed to deck with approved annular
ring shank nails and tin caps at a maximum 12" o.c. at the side laps and 6" o.c. at the end laps.
No nails or tin caps shall be exposed.
Surfacing: Approved for Mechanically Fastened Cement or Clay Roof tiles. Tri-Built S/A HT TU
Underlayment may be used with any approved roof tile system adhered as specified in their
current NOA using any foam adhesive listed and having a current adhesive NOA approval.
_ NOA No.: 15-1123.06
r1 n�a Nauru rr Expiration Date: 09/29/20
a� Approval Date: 04/28/16
Page 3 of 5
• •
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
the applicable building code. Tri-Built S/A HT TU Underlayment,Tri-Built Smooth HT S/A Underlayment or
Tri-Built Sand-R SA Shingle Underlayment shall be installed in strict compliance with the applicable building
code.
3. Tri-Built S/A HT TU Underlayment,Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle
Underlayment shall be applied to a smooth,clean and dry surface,free from irregularities. Re-fasten any loose
decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and
debris prior to application. When a smooth,clean and/or dry surface cannot be obtained,the substrate shall be
primed with Elastocol Stick prior to application.
4. Tri-Built S/A HT TU Underlayment,Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle
Underlayment shall not be applied over an existing roof membrane as a recover system but may be applied over a
roofing Base/Anchor sheet underlayment.
5. Tri-Built S/A HT TU Underlayment is acceptable for use in foam adhesive set and mechanically fastened roof tile
systems as specified in the surfacing option of the approved assemblies.
6. Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle Underlayment shall not be left exposed
as a temporary roof for longer than 30 days.
7. Tri-Built S/A HT TU Underlayment shall not be left exposed as a temporary roof for longer than 180 days of
application.
8. Tri-Built S/A HT TU Underlayment,Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle
Underlayment may be used with any approved roof covering listing Tri-Built S/A HT TU Underlayment,Tri-Built
Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle Underlayment. If Tri-Built S/A HT TU
Underlayment,Tri-Built Smooth HT S/A Underlayment or Tri-Built Sand-R SA Shingle Underlayment is not
listed,a request may be made to the Authority Having Jurisdiction(AHJ) or the Miami-Dade County Product
Control Department for approval based on the necessary documentation to detail compatibility of the products,
wind uplift resistance and fire resistance results.
9. When applying the membrane in the valley, start at the low point and work to the high point,rolling the
membrane from the center outward in both directions. For ridge applications,center the membrane and roll from
the center outwards in both directions.
10. Membrane shall be applied to protrusions, slope changes,valley, curb,and other roof top penetration details
before any other sections of the roof.
NOA No.: 15-1123.06
t#�AM1k .A�EC Expiration Date: 09/29/20
,• ce :a
Approval Date: 04/28/16
Page 4 of 5
11. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
12. Tiles must be staged onto Tri-Built S/A HT TU Underlayment not to exceed 10-high,to the standard maximum
roof pitch of 6:12 for flat tiles and 5:12 for lugged tiles. Lugged tiles staging at slope>5:12 shall use alternate
staging method(bottom tile shall be inverted followed by eight tiles high on slope, as illustrated in Figure 1
below).
sky..
Y�
Figure 1: Alternate Staging Method
At roof slopes greater than the preceding limitations all tiles shall be loaded onto a nominal 1"x 2"horizontal
batten to prevent slippage.
13. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city,state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade
County Product Control Seal as shown below.
MIAMI•DADE COUNTY
�Fiu..•
rnpl
END OF THIS ACCEPTANCE