Loading...
HomeMy WebLinkAboutProduct Approval (2) 7/8/2016 Florida Building Code Online ry `-�'2.e'.�. ��" R [� ��4 s`n'� a3 icy• C `S•. �a,�.13Q :�. mow:'.:..-c.,-..� �r;'Lx iJ^ ;;Ti T„ SMS Home i Log In ? User Registration Hot Topics '•, Submit Surcharge Stats&Facts i Publications FBC Staff j BCIs site Map i Links Search Busines Pf� a " Product Approval r4/fessf6n6l . USER:Public User s R roufai ion .r ® Product Approval Menu>Product or Application Search>Application Llst>Application Detail `r ? FL# FL15529-R1 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer IKO Industries, Ltd Address/Phone/Email 40 Hansen Road South Brampton,NON-US LGW 31­14 (708)496-2800 Ext200 rmetzOO1@tampabay,rr.com Authorized Signature Robert Metz rmetzODI@tampabay.rr.com Technical Representative Bob Metz Address/Phone/Email REMCO of Pinellas 456 Avila Circle NE Saint Petersburg, FL 33703 (727)776-5261 rmetzOO1@tampabay.rr.com Quality Assurance Representative Don Shaw Address/Phone/Email IKO Industries LTD 120 Hay Rd. Wilmington, DE 19808 (717) 579-6706 don.shaw@iko,com Category Roofing Subcategory Underlayments Compliance Method Test Report Testing Lab PRI Construction Materials Technologies, LLC Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 06/26/2025 Validated By Zachary R. Priest, P.E. =` Validation Checklist-Hardcopy Received Certificate of Independence FL15529 R1 COI FL12838 R2 COI PRI CMT Cert of Indeoendencefl-I.pdf E15529_RI_COI FM- Certificate of Independence 3-25-2011.Ddf Referenced Standard and Year(of Standard) Standard Year D1970 2009 Equivalence of Product Standards Certified By https•J/www.floridabdlding.orgfpr/pr app dtl.aspx?param=wGEVXQwtDgvKmQdIDUtQtIXdgHl&-AWg7ZYjps%2fluk8aszyMdl6clg%3d%3d 1/2 7/8/2016 • Florida Building Code Online • ~ Product Approval Method Method 1 Option B Date Submitted 06/29/2015 Date.Valldated 07/14/2015 Date Pending FBC Approval 07/23/2015 Date Approved 10/16/2015 Summaary of Products FL# Model,Number or Name Description 15529.1 5tormShield Standard Ice and #7910033 Water Protector Limits of Use Installation Instructions Approved for use in HVHZ: No FL15529 Rl II SShieldIWO806 ADDlication Instructions Approved for use outside HVHZ:Yes 02 12.Ddf t Impact Resistant: N/A Verified By: PRI Construction Materials Technologies, LLC Design Pressure: N/A Test Reports Other. FLIS529 R1 TR IKO-081-02-01 Report ASTM D 1970 � StormShield Standard IceL and Water Prptpgtor Imo_-_2Q PRI,odf FL15529 RS TR IKO-143-02-01 FBC 2014 Letter- FBC FL15529. df £eaci; Nett Contact Us;:2601 Blair Stone Road,Tallahassee R 32399 Phone;BSD-497-182a The State of Florlda is an AA/EEO employer.Copyright 2007-2013 State of Florida. ::Privacy Statement::Aecesslbilfty Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the ofnce by phone or by tradlUonal mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,20I2,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here, Product Approval Accepts: WMimi 1 cLtk CrOdii Gard' safe httpsJ/www.floridatwilding.org/pr/pil_app_gl.aspx?param--wGEVXQwtD qvKrn Qd101J tQt[XdqH l6aAWg7ZYj ps%2nuk8araZy M dl 6clg%3d%3d 2/2 i CONSTRUCTION MATERIALS TECHNOLOGIES Brad Grzybowski Managing Director July 9,2015 Dear Sir/Madam, PRI-CMT tested several products for KID Industries and subsequently issued Laboratory Test Reports.These reports have been utilized to support FL15529,This letter serves to establish compliance of legacy test reports to FBC 2014. FL15529—StormShield Standard Ice and Water Protector Product Specification a Applicable product specification:ASTM D1970 • FBC 2014 referenced standard year:ASTM D1970-09 • Test Report: PRI Project/Report Number IKO-081-02-01 states compliance to ASTM D1970-08. • Action:-Establish equivalency between ASTM D1970-08 and ASTM D1970-09. • Conclusion: Compliance to FBC 2014 established, Statement of Independence:PRI Construction Materials Technologies and/or Duc T.Nguyen, FL P.E.do not have nor plan to acquire a financial interest in any company manufacturing or distributing products for which the test reports are issued. ell Signed: o s 1' Signed: _ (-- 'C.jL.�_. 'Brad Gtzybki Duc T. u Managing Drrector Florida Regis ere rofessional Engineer P.E.Number:65034 Date: July 9,2015 Date: July 9,2015 IKO-143-02-01 PRI Construction Materials Technologies,LLC.6412 Badger Ditve Tampa,FL 33810 Tel:813.621-5TTT Fax:813-621-5840 a-mall:materialstesting@pricmt.com WebSite:ht1p1hvww.pdcmtccm i 1 APPLYING IKO'S STORMSHIELD No ICE & WATER PROTECTOR Caution • Read all instructions before proceeding with application. • Membrane must always be covered by shingles or other roofing materials. It must not be left exposed to the weather. • This product is a vapour retardant. Space under roof deck must be properly ventilated to avoid moisture condensation. • In cool temperatures membrane should be tacked in place with mechanical fastenings. • Installation is not recommended when air and substrate surface temperatures are less than 5°C(40°F). APPLICATION DIRECTIONS Surface Preparation • The roof deck must be clean, smooth, dry and free of sharp protrusions. • Metal and masonry surfaces must be primed. Installation 1. Cut the membrane into 3 m to 4.5 m (10 ft. to 15 ft.)lengths. 2. Unroll and align with the lower edge of roof. lack top edge with four equally-spaced temporary fasteners. 3. Lift the lower half and remove the lower release film, exposing the adhesive surface. 4. Carefully reposition the membrane down onto the deck and press firmly in place. Avoid wrinkles. Remove temporary fasteners. 5. Fold top half down and remove release film. 6. Carefully reposition the membrane up onto the deck and press firmly in place. Avoid wrinkles. • If two courses are required, the top course should overlap the selvage tape on the lower course by 75 mm (3"). • End laps must be at least 15 cm (6")and rolled to ansure adhesion and should be located at least 61 cm (24")from those in the previous course. • Apply each course carefully. • Best suited for low sloped roof areas. Cover entire area with StormShield Standard Ice and Water Protector, lapped as outlined above, and then shingle as per normal shingle exposures. Valleys and Ridges • Cut the membrane into 1.2 m to 1.8 m (4 ft. to 6 ft.) lengths. In the valley, start at the low point and work upwards,overlapping each sheet at least 15 cm (6"). Peel off the release film and centre the sheet over the valley-or ridge. Drape and press in place working from the centre outward toward the edges. . . • Membranes must not be left exposed in an open valley. Ice Dam Protection • Membrane must be applied to'reach above the highest expected level of ice dams, and at least 61 cm (24") up the roof from the vertical projection of the interior surface of the outside wall. Drip Edge • Drip edges must be located under the membrane at the eaves, and over the membrane at rake edges. Note • Do not remove selvage tape. Storage • Store rolls in their carton until application. Store inside or under cover not over 400C(104"F).- SShieldlW 08-06 J•_.w r•• •i•• �r Ito y l .1 - •• .1 1 � j r 1- � r •1J r/ 1, :f: rlft�l :'1 ri` J' �•eri•f \.i d rr. J1r iF' i�'r•'1j or . _ .• . _ � �.--•• .fir-.�` .{ • J 4. rt� tyr Y'�+ 1', f}. .e `:t' •It _•� :as. .. . lx J %� f •r i.,"{.� .r�:� Yfr,l+ry fFf ff� .• , rr f'jj 'J SShieldlW 08-06