HomeMy WebLinkAboutProduct Approval (4) Florida Building Qode Online http://Www.floridabuilding.org/pr/pr_appdti.aspx'lparani=%AkiEVX...
-AN
BCIS Home
5-
Facts
e
Log In User Registration Hot Topics Submit Surcharge Stats&Fa Pubficatbns F13C Staff BCIS Ste Ma
Bus n esss,:
Professional - USER:PProduct Approvalubric User
�2*r ,al.Li grej>"p-kjjkL&p aj�n Ust>Application Detan
FL
FL2569-Rll
... ..........
Application Type Revision
Code Version 2014
Application Status Approyed
Comments
Archived
Product Manufacturer Soprema,Inc. (Canada)
Address/Phone/Email 3.640 rue Haggartv
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memathieu @soprema.ca
Authorized Signature Marc-Etienne Mathieu
memathieu@sqprema.ca
Technical Representative Marc-Etienne Mathieu
Address/phone/E-mail 1688 lean-Berchmans-Michaud
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memathieu@spprema.ca
Quality Assuranc6 Representative Jean-Francois Cote, Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluatlan Report from a Florida Registered Architect o
Florida Professional Engineer.
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Rdbert J. M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By John W. Knezevich, PE
of3 1/5/2016 3:08 PM
71orida Buildipg Code Online http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVX...
V Validation Checklist-Hardcopy Received
Certificate of Independence 2 89 Rli COl 201_5 Ot Cwi hdiEri=.ne!j,._od
Referenced Standard and Year(of Standard) Standard
ASTM D1970
ASTM D6163
ASTM D6164
FM 4474
FRSA/TRI April 2012 (04-12)
TAS 103
TAS 110
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/15/2015
Date Validated 10/19/201.5
Date'Pending FBC Approval 10/21/2015
Date Approved 12/15/2015
Summary of Products
FL# Model,Number or Description
Name
2569.1 Soprema Roof Self adhering roof underlayments
Underlayments
Limits of Use Installation instructions
Approved for use in HVHZ: No FL 6 R11 II 20IS 10 FINAL FTWAL EQ gOPREMA CA tiNDERLAYP
Approved for use outside R3_i.odf
HVHZ:Yes Verified By: Robert Niemineri, P.E. PE-59166
impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-90 Evaluation Reports
Other: i.) Refer to ER Section S for f L2569 R11 AE _�015 10 FINAL ER SOPREMA.CA UNDER!.0
Limits of-Use.2.)The design pressure B-L,R
noted'herein pertains to underlayment Created by Independent Third Party:Yes
systems'useti beneath adhesive-set the
systems. Refer to ER Section 5.6.4 for
details.
BaCK INext
Contact Us;;1940 North Monroe Street.Tallahassae FL 32399 Phpne:a54-487-1824
The State of Florida is an AA/EEO employer.�ppnrriah 200� 7 2013 State offElorlda.::Privacy Statement::ACM ibij)<y Statement;;R
Under Florida taw,email addresses are public records.If you do not want your e-mail address released in response to a publIc-records req
of 3 1%5/2016 3:08 PM
Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_dti,aspx?param=�vvGEVX..:
electronic mail to this entity.Instead,contact the office by phone or.by traditional mall.if you have any cluestl6ns,please contact 850.487.
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter'455,F.S.must provide the Department wi
they have one,The emails provided may be used for official communication with the licensee.However email addresses are public record.D
supply a personal address,please provide the Department With an email address which can be made available to the public.To determine T yo
Chapter455,F.S.,please c ick here•
Product Approval Accepts,.
s�cc.•ctrit'�•.;.;•
of 3 1/5/2015 3:08 PM
.
`^- EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization#9503
3S3[H0STIAN STREET,UNIT#13
� | �����
T��I�`�1 1 � `,~"^�����
OXFORD,CT 06478
| ' PHONE:(2n3)2629245
FAX:(ZO3)262'9Z43
EVALUATION REPORT
Soprema,Inc. Evaluation Report S18010.06.09-119
1n*v rue Haggerty' —2
Drummondville,Ou6bec]I[SP8 Date uf Issuance.O6'1S/2009
.Canada Revision 9:10112/2015
Scops|
This Evaluation Report.is issued under Rule 61520'3 and the opdixobky rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
pro.ducts described herein have been evaluated for compliance with the Sm Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Sopremna Roof Underlaymemtm
LAosUmm: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
' herein. �
ComnmusoCmMpoAmcc: This Evaluation Report is valid until such time as the named prmduct(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation' Report by the named client constitutes agreement to notify Robert Nienninen^ P.E. If the product
changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review ofthis
Evaluation Report relative tm updated Code requirements with each Code Cycle.
AonEnzmsoxsmr: The Evaluation Report number preceded by the words Trinity IERD Evaluated" may be displayed in
odymtisingiitemture. |f any portion of the Evaluation Report io displayed,thenitshaU6edoneWitsentirety.
|mSpcCnom:Upon request,o copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its.distributors and shall ba available for inspection ott6e}obsite at the request mf the Building Official.
This Evaluation Report consists of pages 1 through I
prwparedbV:
'
`
m"facsfmile sea]appearing was authorized by Robert wierninen,
Robert J.M,Niennimeo,p.E ^conIO/12/215 This does riot same as anm=tro"icaliVstne^
Florida Registration No.a9ua6,Florida Dc*ANE1983 ��� ^��e m= �u*dmthe
oy~°""`-� Product Approval Administrator and m the named**=
CEm/"I�m`owur114onpEwua4cc:
1. Trinity|smQ does not have, not does |t intend,nacnuimorwill it acquire, afinancial interest in any company manvfactunno-u,
distributing products uevaluates.
2. r,innv|seois not owned,operated o,controlled b any company manufacturing o,distributing products uevaluates.
s. Robert Nlemlnen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the.evaluation reports are being issued.
4. Robert Nleminen,l>.E.does not have,nor will acquire,a financial Interest in any other entity involved in the approval process of the
product.
� s. This Is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E.are, In any way,the.Desigrker of Record for any
project on Which this Evaluation Report,or previous versions thereof,is/was used for permitting or.design guidance unless retained
specifically for that purpose.
S+
TRIN111"i' OR
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following-'Standards.
Compliance is-subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3:1 Wind Resistance FM 4474 20D4
1507.2.4,1507.2.8, Physical Properties ASTM D1970 2009
1507.2.9.2,1507.4.5.1,
1507.5.3,1507.7.3
1507.11.2 Physical Properties ASTM D6163 2000
1507.11.2 Physical Properties ASTM D6164 2005.
1523.6.5.2.1 Physical Properties TAS 103 1995
TAS'110 Accelerated Weathering TAS 110 2000
1507.3..3 Installation Practice FRSA/TRI April 2012(04-12) 2012
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) ASTM D1970/TAS 110 29.68.05.04-2 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05=2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05-R1 04/18/2007
ERD(TST6049) TAS 103/TAS 110 S7120.11.07-2 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-R•I 04/01/2010
ERR(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.10-R1 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.09-R2 10/05/2010
ERD(TST6049) ASTM D1970 537210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 S40540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015
M-D(CER1592)' HVHZ Compliance 09-1005.02 11/04/2010
M-D(CER1592) HVHZ Compliance 13-0530.02 11/27/2014
ICC-ES(EVL2396) 2012,2009 and 2006 IBC Compliance ESR-1524 10/01/2014
PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 05/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation • Up.10/16/2017
4. PRODUCT DESCRIPTION:
4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof
underlayment.
4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment available in two widths;36 and 45 inch.
4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment;available in 3.3 ft x 65 ft rolls.
Exterior Research and Design,LLC. Evaluation Report S18010.06.09-R9
Certificate ofAutharizatich#9503 FL2569-R11
. .. Revision 9110112/2015
Page 2 of 7
` 1
., �g ;
i E xa.P'
4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment.
4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlaymerit available in two widths;36 and 45 inch.
4.6 Lastobond Pro HT-5 is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified
bitumen roof underlayment.
4.7 Lastobond. 195 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment.
4.8 Lastobond is. a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment.
4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
. . underlayment.
4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen
roof underlayment.
4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified .bitumen roof
underlayment,with a 36-inch sheet wldth.
4.12 PrimeSource Grip-Rite Eave&Valley Protector is a self-adhering,glass-mat reinforced,sand-surfaced,SBS.
modified bitumen roof underlayment,with a 36-inch sheet width.
4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof
underlayment,with a 44-inch sheet width. .
. 4.14 Cofphene FR GR is a self-adhering, fiberglass reinforced, granule surfaced, SBS modified bitumen roof
underlayment.
4.15 Unilay (e) is a mechanically attached, polyester reinforced, granule-surfaced, SBS. modified bitumen roof
underlayment.
5: ILIMiTAT1dNs:
5.1 This is a building code evaluation. Neither Trinityl.ERD nor Robert Nieminen, P.E. are, in anyway, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed,a request may be made to the AHJ for approval
based on this evaluation combined with supporting data for the prepared roof covering:
5.5 Allowable.roof covers applied atop the underlayments are follows:
TABLE 1: ROOF COVER OPTIONS
Asphalt Nail-On Foam-on Metal wood Shakes Slate
Underlayment .Shingles Tile Tile Shingles
Lastobond TU HT Yes Yes Yes Yes Yes Yes
See 5.5.1
Lastobond Shield/Pro HT-N/ Yes No No No Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT/Pro HT-5 Yes No No Yes Yes Yes
Lastobond/Lastobond 195 Yes No No No Yes Yes
Exterior Research and Design,I.I.C. Evaluation Report S18010.06.09-R9
.Certr}rcate ofAuthorkadon#9503 FL2569-R11
Revision 9:20/12/2015
Page 3 of 7
IN # `tI
TOLE 1: RooF COVER OPTIONS
Underlayment Asphalt Nail-On Foam-On Wood Shakes&
Metal Slate
Shingles Tile, Tile Shingles
Lastobond ECO /RESISTO
LB1236,Grip-Rite Eave&Valley Yes. No No No Yes Yes
Protector/RESISTO LB1244
Lastobond Smooth Seal HT Yes No No Yes Yes Yes
Yes
Colphene FR GR Yes Yes See 5.5.1 No Yes Yes
Yes Yes
Unilay(e) Yes Batten Only See 5 5.1 No No No
5.5.1 "Foam-On tile" is limited to.use of the following adhesives unless tensile adhesion/long term aging data
from ark accredited testing laboratory is provided.
Underlayment Adhesives)
Lastobond TU HT 3M 2-Component Foam Roof The Adhesive AH-160(FL6332)or Dow Chemical fileBoridl' Roof
Tile Adhesive(FL717)
Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
Unilay(e) 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:.
Lastobond Shield, Lastobohd Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT S, Lastobond TU HT, Lastobond, Lastobond 195,. Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB1244 ar Lastobond Smooth Seal HT applied to:
➢ Plywood;ASTM D41 primed plywood; OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41
primed Southern Yellow Pine;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
> Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends
priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within
24 hours.
Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to
installation of the self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond„ Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to.:
> Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For Installations
under foam-on tile systems(Lastobond TU HT only), insulation attachment shall be designed by a qualified
design professional and installed based on testing of the insulation/underlayment system in accordance
with FM 4474,Appendix D or TAS 114,Appendix J.
Exterior Research and Design,I.I.C. Evaluation Report918014.06.09-R9
CerU/kate ofAuthor.kadon#9503 FL2569-RII
Revision 9.10/1212015
Page 4 of 7
S . Iq-TY D
5.6.3 Bond to Mechanically Attached Base laver:
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro
HT-S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave &
Valley Protector,RESISTO LB124.4,Lastobond Smooth Seal HT or Colphene FR GR applied to:
➢ ASTM D226,Type I or II felt;5opra-G;Modified Sopra-G.
For installations under mechanically attached prepared roof-coverings, base layer shall be attached per-
minimum codified requirements. For installations under foam-on file systems (Lastobond TU HT only),
base layer shall be attached in accordance with FRSA/TRI April 2012(04-12).
.5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems;where
the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-qh the applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has
already been applied). Refer to FBC 1609 for determination of design wind pressures.
S.6AA Maximum Design Pressure=-45.Q Dsf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)Elastocol Stick or Elastocol 6000
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.2 Maximum Design Pressure=-67.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: Elastocol600c
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
5.6.4.3 Maximum Design Pressure=-60.0 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin
caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps and.6-Inch o.c.in three,equally
spaced rows in the center of the sheet,
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered
5.6.4.4 Maximum Design Pressure=-90.0 psf
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Underlayment: Unilay(e) mechanically attached with Soprafix Polymer Batten Bar (PBg) or Soprafix
Metal Batten Bar(MBB)with Soprema#15-EL fasteners spaced 6-inch o.c,within the 5-
inch wide, self-adhering side laps. End laps are 6-inch wide and sealed using either
heat-welding or hot-air welding techniques.
5.7 Exposure Limitations:
Lastobond, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO 1-131236, Grip-Rite Eave & i
Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond
Pro HT S shall not be left exposed for longer than 90-days after installation.
Lastobond TU HT or Colphene FR GR or Unilay(e)shall not be left exposed for longerthan 180-days after
installation.
Exterior Research and Design,Ut Evaluation Report 5180I0:06.09-119
Certificate afAuthorhatfon#9503 FL2569-R1i
,:Revision 9;10/12/2015.
Page 5 of 7
`
. /,.
� �- �
, `^-
\ �
^^/ T TY�i
�����
' 6. INSTALLATION:
5.1 Sopremo nunf Underlaymentg xhnU be installed in accordance with Soprema published installation
! requirements subject to-the Limitations set forth inSectionS herein and the specifics noted below.
62 Re-fasteh any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to appUoadon, and prime the substrate with E|astoco| Stick or
E|astnco|*GOOo(if appUoab|e).
6.3
�
� 63.1 Shall be installed In compliance with the requirements fonASJM D1970 underlayment in FBCSectionx
� � 15O7 for the type of prepared roof covering to6einstalled.
6.3.2 Non-Tile Applications:
While priming boptional,Soproma recommends priming With Elastocol Stick orElamood6.U0c ifthe-finm|
! roof cove,b not slated fbrinstaAlation within.z4hours.
Apply sheet parallel to the roof edge. Roll out approximately 1Oftofmenbrane and peel back the first 3
ftcf release.film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into place to achieve abond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps
~�
shall be sealed using either heat-welding or hot air welding techniques.
When Installing at slopes above 8:12,Soprema recomrrfend§back-nailing in the overlap area-at the top of
the sheet at1Z-innho.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into plate, working from the center of the valley or ridge in
each direction.. For valleys,apply the sheet starting at the lowest point and work upward.
6.3.]
Reference is made to FRSx/T0 April 2012 (04-12) Installation Manual and Table z-herein, using the
inotructonn'note6 above asaguideline.
� For foam-on tile applications, reference is-made to Section.5.6.4 herein for wind resistance limitations that
fall outside the scope nfFRSA/TRl April 2012(04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
. un6edayment.
k.4. Unilay(e):
6.4.1 Non-Tile Applications or Nail-On.Battened Tile Applications:
Reference is made tu Table 1 herein and FRSA/TR|April 2012(O4' 2)|nstaUatiunW1anua|(ifoppUooble).
. Apply sheet parallel to the roof edge and, starting at the eaxe with the selvedge-edge ups|ope,
mechanically attach the 5-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap-
nails spaced 36-inch o'c' Apply the.second course in a water-shedding manner with self-a4he,in8 side-
laps. vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure awatertight
application.
� Vertical seams should be 6'inches and staggered not less than 2-ft from vertical seams in the course
� below. All over-granule end-laps shall be sealed udng either heat-welding or hot airwelding techniques.
Exterior Research and Design,uc Evaluation Report o1ooxo.0aze�ny
pertifiCate of AUtharizatlaft#9503 ��-R-il
Revision mu0/12/2m
Page oo,r
TRINMf°t �r;;
Tile(if applicable)shall be loaded and staged in a manner that prevents the slippage and/or damage to the
underlayment:
6.4.E Foam-On Tilg Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual, Table 1 herein and Section 5.6.4.4
herein.
Apply sheet parallel to the roof edge and, starting- at the eave with the selvedge-edge upslope,
mechanically,attach the 5-inch wide selvedge-edge to the wood deck Soprafix Polymer Batten Bar(.PBB)or
Soprafix Metal Batten Bar (MBB) with Soprema #15-EL fasteners spaced 6-inch o.c. Apply the second
course in a water-shedding manner with self-adhering side-laps. Vigorous hand or motorized roller
pressure is applied to the self-adhering laps to ensure a watertight application.
Vertical seams should be 64nches and staggered not less than 2=ft from vertical seams in the course
below. All over-granule end-laps shall be sealed using elther.heat-welding or hot-air welding techniques.
Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to .the
underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this.product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under-Rule 61G20-3 QA
requirements'.
9. QUALITY AssURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,LLG Evaluation.Report 518010.06.09-R9
Certificate of Authorlwtion.0503 FL2s69-R11
Revision 9:10/12/2015
Page Tof 7