HomeMy WebLinkAboutEngineering Architectonic Inc --
March 8, 2017
AWA Aft
Saint Lucie County Building Department
Attn: Roof Permit Plan Review FILE UUPY2300 Virginia Avenue
Ft. Pierce, FL34982 17 0
1 s mo-vo&
Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure
located at 5041 Tozour Road,Saint Lucie County, Florida
Manufacturer: Polyglass USA
Profiles: Modified Bitumen Roof System, FL#1654-1119
Code: FBC 2014;Section R 905.10
Wind Speed: 160 MPH; Ultimate Design Wind Speeds
Exposure: B
Mean Roof Height: 30' Maximum
Pitch: %/12
Required Design Pressure: Zone1:-38.2 Zone 2:-53.9 Zone3:-101.4
Maximum Uplift Pressure: -90 psf
Roof Decking: Min 15/32" plywood
Base: SBS-SA(self-adhering)
Ply Sheet: (Optional)One or more Elastoflex SA V Base(self-adhering)
Cap: SBS-SA,SBS-TA,APP-SA,APP-TA(self-adhering)
The above approved,,as per Florida Building Code Compliance acceptances, 2014 Florida Building Code,
and the Manufacturer's recommendations.
Respe°ctfully submitted;,10,31 t
=; o
Mi` bael Seal`
oe' .
Arc•itctgnic Inc.
806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com