Loading...
HomeMy WebLinkAboutEngineering Architectonic Inc -- March 8, 2017 AWA Aft Saint Lucie County Building Department Attn: Roof Permit Plan Review FILE UUPY2300 Virginia Avenue Ft. Pierce, FL34982 17 0 1 s mo-vo& Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at 5041 Tozour Road,Saint Lucie County, Florida Manufacturer: Polyglass USA Profiles: Modified Bitumen Roof System, FL#1654-1119 Code: FBC 2014;Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 30' Maximum Pitch: %/12 Required Design Pressure: Zone1:-38.2 Zone 2:-53.9 Zone3:-101.4 Maximum Uplift Pressure: -90 psf Roof Decking: Min 15/32" plywood Base: SBS-SA(self-adhering) Ply Sheet: (Optional)One or more Elastoflex SA V Base(self-adhering) Cap: SBS-SA,SBS-TA,APP-SA,APP-TA(self-adhering) The above approved,,as per Florida Building Code Compliance acceptances, 2014 Florida Building Code, and the Manufacturer's recommendations. Respe°ctfully submitted;,10,31 t =; o Mi` bael Seal` oe' . Arc•itctgnic Inc. 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com