Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval
I 'g SUPPLY & MANUFACTURING 5VCRIMP GA. 5VCRIMP ROOF PANEL OVER 15/32" • • TM Product Evaluation Report GULF COAST SUPPLY& MANUFACTURING, LLC• 26 Ga. 5V Crimp Roof Panel over 15132"Plywood Florida Product Approval #11651.13 R �i Florida Building Code 2014 - 49 Z 30 Per Rule 61 G20-3 ST. LUCIE COUNTY Method: 1 -D BUILDING DIVISION REVIEWED FOR COMPLI E Category: Roofing REVIEW D BY Subcategory: Metal Roofing DATE PLANS AN ERMIT Compliance Method: 61 G20-3.005(1) d) MUST BE KEPT ON JOB OR NON HVHZ NO INSPECTION WILL BE MADE Product Manufacturer: COPY Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Lr Newberry, FL 32669 %��•�`p•�•11EL S,•k� o••oCENs�yy,: Engineer Evaluator: ')k: ho, 75519 Dan Kuhn, P.E. #75519 _ Florida Evaluation ANE ID: 10743 13: STATE OF THESE PLANS AND ALL PROPOSED)NORY �.�•. � Validator: %;FN"•4 O R I p P ••�kr ARE SUI 10T 10 Miy 0( ^� OTIONS s •• N REWIRED it� EI�O l�; y0�� � (} eT Locke Bowden, RE. #49704 /ONA L SNG�,• MAY DP�1EOIASalkf1Y IN("Eft TO i� 9450 Alysbury Place o 6�30�2015 pop4Y WI`�N AL APPWO�p 00990s Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 "JkZl,c FASTENERS QR� f�ON�'4ENTS ARET`1HF RESPOPISIBUTY OF THE FL#11651.13 R2•JUNE 15,2015 NON I pAC l OR OF RECORD ENGINEERING,KUHN 4N Gulfca�Nt SUPPLY & MANUFACTURING 5VCRIMP 1 26 GA. 5VCRIMP ROOF PANEL OVER • • FLORIDA PRODUCT APPROVAL NO. 11651.13 R2 TM Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Product Description: 5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage,through fastened roof panel with fasteners in the panel flat over minimum 15AZ" plywood decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel,ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2014 Section 1507.4.3. Paint Finish Optional Yield Strength: 80.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2014, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 24" Coverage Rib Height: 3/8" Major Rib Panel Fastener: #9-15x1.5" with sealing washing in the flat of the panel or approved equal, '/a" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4 Substrate Description: Minimum 15/32" thick,APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/Florida Building Code 2014. Design Uplift Pressures: Table"A" ;Maxirrium Total Uplift Design Pressure 94.25.psf 131.0 psf Fastener Pattern 12"-12" 9.5"-2"-9.5" Fastener Pattern'Spacing 16" O.C: 16" O.C. Design Pressure includes a Safety Factor=2.0. I FL#11651.13 R2•JUNE 15,2015 ' � � ©C ENGINEERING,KUHN k � SUPPLY & MANUFACTURING 5VCRIMP na G 26 GA. 5VCRIMP ROOF PANEL OVER • • FLORIDA PRODUCT APPROVAL • TM Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2014, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06-Test for Uplift Resistance of Roof Assemblies • UL 1897-04-Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94/1897-98 Uplift Test Force Engineering &Testing, Inc. (FBC Organization#TST-5328) Report No. 117-0053T-05 & 117-0331 T-08 2. Certificate of Independence By Dan Kuhn, P.E. (FL#75519)@ Kuhn Engineering, LLC (FBC Organization#ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. FL#11651.13 R2•JUNE 15,2015KUHN - ENGINEERING, /Nw.X. �© SUPPLY & MANUFACTURING d . f NV N 5V%0K1ERWnE 26 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD* • ■ ,A PRODUCT APPROVAL • TNt Design Procedure: For roofs within the parameters listed on the load table,fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design.The maximum fastener spacing listed herein shall not be exceeded.This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL#11651.13 R2•JUNE 15,2015 - L" KUHN ENGINEERING, momm IMP &@0.9 g SUPPLY & MANUFACTURING 5VCRtMP • ROOF PANEL OVER 15/32" PLYWOOD* FLORIDA PRODUCT • , APPROVAL • Try ENGINEER LOAD TABLE:26 Ga. SVCrimp Roof Panel over 15132"Plywood Buildings having a,Roof Mean Height<20'-0"; Roof Slope: 2"/12" - 12"/12" Gable or Hip Roof; Wind Speeds 120- 180mph, Exposure C, Risk Category II, Enclosed Building, based on Florida Building Code 2014. 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE (MIN.1/4" SPEED penetration) (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER SPACING SPACING SPACING SPACING SPACING SPACING SPACING ZONE 1 #9-15x1.5" Plywood 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 ZONE 2 #9-15x1.5" Plywood 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 ZONE 3 #9-15X1.5" Plywood• 16"TYPE•1 16"TYPE 16"TYPE 1 -16"TYPE 1 1&TYPE 1 16"TYPE 2 16"TYPE 2 1.)PANEL DESCRIPTION:5V CRIMP, MIN.26 GA., GRADE 80,24"COVERAGE. 2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER W/MIN.1/4" PENETRATION. 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:-94.25 PSF® 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN,-131.0 PSF @16" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING_ 4.)PLYWOOD DECKING:MIN.15/a2"THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014. 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2014 ZONE 2 HIP ROOF a Note:Dimension(a)is defined as 10%of the minimum width of the building or ' ZONE 3 1 1 a 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be less than either 4%of the minimum width of the building or 3 feet. N RIDGE TYPE 1 FASTENER PATTERN I -- `�\ (1) #9-15 x 1-1/2" HWH w/Sealing Washer i' ZONE 1 `� 1211 2" 1211 /------------------\ 1; 14— EAVE At Panel Lap ZONE 2 GABLE ROOF TaT —, ————— ya TYPE 2 FASTENER PATTERN rRIDGE (1) #9-15 x 1-1/2" HWH w/Sealing Washer a +--------------------- 2" -9.511 II 9.5"�`2"1 ZONE 1 I I I I • \ ZONE 3 VEAVE v11�i ti� FL#11651.13 R2•1UNE 15,2015 Eli KUHN • 0 0 TAMKOO MO.30 UL PRODUCT DATA Asphalt Saturated Organic Felt Manufactured in Joplin, MO, Frederick, MD, and Green Cove Springs, FL TAMKO® NO.30 UL SATURATED FELT features a tough TAMKO organic felt that is saturated with asphalt. USES :Aelted for use as an underlayment felt to be applied the roof deck prior to the installation of TAMKO alt shingles. CERTIFICATIONS U.L. Built-Up Type 30 Label ASTM D 226,Type 11 PRODUCT DATA* Roll Dimensions 72'X 36" Coverage per roll 2 Squares Laying Lines 2", 4", 17" *All values stated as nominal THIS PRODUCT IS SOLD"AS IS"WITHOUT WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. O'Y F L E C,,-, Off Visit our Web Site at tamko.com CAUnM Ties product contains wood dust.Wood dust has been classified as a ImaW Farman carcinagen try the International Agency for Research on C mxr(IARC)and the National Tc)mdogy Program.This product also contains omdiz_d aspha%Ocapalional exposures to cmdzed malt and its ®- onsmmdur V=frghmabeendassfie WKRCasa"probablehnsnancmanogeW.OradzedasphaltdmcmMmPo"ftAranaticHyd=mbms y some afvhich have been dassrfied by IARCas kvm or probable human carcincgens.-Rra phydcal nature afft product may help lationor dermal hazard during appficahm ard/orrenoA However,physical force:;srhassavmg,grmdug ordrfvg du'ag denofbon workand heafirg crtwring ® mWwcma efhemhafa mordermalepxsuehazadoffhispmducLTakeprecalbomtopmvetbmahngardardactmdhdmr. TAMKOCentral District 220 West 4th St. Joplin,MO 64801 800-641-4691 Northeast District 4500 Tamko Dr. Frederick,MD 21701 800-368-2055 B0160ING PRODUCTS Southeast District 2300 35th St. Tuscaloosa,AL 35401 800-228-2656 Southwest District 7910 S.Central Exp. Dallas,TX 75216 800-443-1834 TAMKO Logo,Roofer Logo and TAMKO® Western District 5300 East 43rd Ave. Denver,CO 80216 800-530-8868 are registered trademarks of TAMKO®Building Products,Inc. Information included in this product data sheet was current at time of printing.To obtain a copy of the most current version of this product data sheet,visit us online at tamko.com or call us at 800-641-4691. Rev.052012