Royal Adhesives & Sealants Pull Test Result Sheet
Project Name: Treasure Cove Dunes
Location: Vero Bch,FL
Date: 4/13/16
Roof Area Location: Field Ambient Temp.: 85F
Building Criteria: Height: Width: Length:
Adhesive Tested: JM RSUA/JM One Step Bead Spacing: 12"on center
Insulation Used: 1/4 in Securock
Tester Used: DMD Force Measurement systems.Model PFT2000A S/n 1510001
Max Capacity of Tester: 2000 lbs
Test Performed By: Grant Harrison-Royal Adhesives and Sealants
Witnessed by: Todd Page and Todd Rauktis JM Reps
Test Cut Areas Repaired By: The Roof Authority
Royal Adhesives&Sealants cannot be Geld responsible for the watertightness of the repairs where tests were performed,nor can
they be held responsible for the structural integrity of the roof deck or any material below the adhesive.
Project Type: New Construction Tear Off xRetrofit
SUBSTRATE TESTED
Concrete Wood
Lightweight Insulating Concrete Smooth BUR
Structural Lightweight Concrete Gravel Surface BUR
Cementitious Wood Fiber(Tectum) Steel
Gypsum x Modified
17340 Munn Road Chagrin Fails,Ohio 44023 o wnww.mMenniumadhesives.com
Results Mode of Failure
BLDG 1=925 Scale—225 PSF--OSFA Uplift Value Met Per JM Instruction
BLDG 2=865 Scale—210 PSF--RSUA Uplift Value Met Per JM Instruction
BLDG 3=805 Scale—195 PSF--OSFA Uplift Value Met Per JM Instruction
BLDG 4=745 Scale—180 PSF--RSUA Adhesive Failure
Comments:
One square test area was identified for testing the existing Modified for each BLDG.All loose
debris was swept off the testing area. A 2ft x 2ft piece of 1/4in Securock was adhered to the Mod
Bit.Then a 2ft x 2ft piece of Plywood adhered to the Securock to fit the Pull Tester plate
The adhesive beads were left to cure for a minimum 3hrs for OSFA and 4hrs for RSUA prior to
conducting the pull tests per ANSI/SPRI IA-12010 specification.
Photographs:
BLDG1.
4/13/16
JM OFSA
12" on center
925 Scale=225 PSF
C
r
Correction Made By Grant Harrison Royal Adhesives & Sealants Florida Rep
BLDG2.
4/13/16
JM RSUA
12"on center
865 Scale=210 PSF
o-
4�6�1L
� E�orE
i
•
JM
FSA
' �
n center
805 Scale= 195
B , I
•
12" on center
685 Scale •
Tt
RE-
G'