Please be advised that the existing roof is a Johns Manville Hot Applied SBS system over insulation and perlite/fesco
coverboard, also applied in hot asphalt, over a concrete deck. Please see attached FBC that-reflects the existing _
installed systen> . I have highlighted the system on the Trinity/ERD report, C-4. This should satisfy the below
requirement of"FBC Approval Documentation.
From the Submitted PMMA FBC Report...Noted Item from Building Department
1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members
shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be
documented through proper codified and/or FBC Approval documentation.
Let me know if you have any questions.
Thanks
Todd Rauktis
Sr. Sales Representative—Central Florida I Roofing Systems Group
Johns Manville I A Berkshire Hathaway Company
C: 407-429-8626
Email: Todd.Rauktis@jm.com
Johns Manville
This email,including attachments,is intended for the person or company named and may contain confidential and/or legally privileged information.
Unauthorized disclosure,copying or use of this information may be unlawful and is prohibited.If you are not the intended recipient,please delete this
message and notify the sender.
Johns Manville is a manufacturer of commercial roofing products and offers this general conceptual information to you
as a courtesy only. This complimentary as is not to be used or relied upon by anyone as a substitute for
professional engineering design and documentation required by building code,contract or applicable law. By accepting
these comments you agree they do not constitute any representations, endorsements of, or an assumption by Johns
httpsJ/mail.google.com/mail/uf0l?w=2&ik=63BB7cdOea&view=pt&search=inbox&th=15aaf7fl6bf7gb5b&sim 1=15aaf7fl6bf79b5b 1/2
3I8/2017 G&G R Construction Inc Mail-Treasure Cove Dunes-PMMA Existing Assembly
Manville of any responsibility/liability or either the adequacy of the design of this Sing/roofing system, code
compliance, material or any other material not supplied by Johns Manville.
r TDC Existing Assembly JN1 SBS_FL2948-R'19.pdf
1923K
I
I
i
i
httpsJ/mail.google.com/mail/u/0/?ui=2&ik=63887cdOea&view=pt&search=inbox&th=15aaf7fl6bf7gb5b&siml=15aafTfi6bf7gb5b 212
ter
1 EAS U P-e Go�i c -D• r-�ES
�7Cr S a n r, �COTr f�SStc'�B L y
TABLE3A-1: STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER
NOTE:FOR VAPOR BARRIER OPTIONS,REFER TO NOTE 15
System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP
No. (Note2) Primer Type Attach Type Attach Base Ply Ply Cap Ply (psf)
(Optional)Min.1.5-inch ENRGY 3,R-Panel,
ENRGY 3 25 PSI,R-Panel 25 PSI,ENRGY 3
Structural ASTM JM BaseGrip (Optional)SBS-AA,SBS- SBS-AA,SBS-
C-1, concrete D41 AGF or CGF,ENRGY 3 25 PSI AGF or CGF, HA Min,1.5-Inch Invinsa Foam HA SD/SA TA TA 155.0
ValuTherm AGF or CGF,ValuTherm 25 PSI ,
AGF or CGF
(Optional)Min.0.75-inch BP-AA,BP-CA2,
C-2 Structural ASTM Min.0.75-inch FescoBoard or DuraBoard HA FescoBoard or DuraBoard HA SBS-AA or SBS- (Optional)BP-AA,SBS- SBS-AA,SBS- -167.5
concrete D41 (homogeneous) (homogeneous) CA2 AA,SBS-CA2 or SBS-TA CA2,SBS-TA
Min,1.5-inch ENRGY 3,R-Panel,ENRGY 3 25 BP-AA,SBS-AA, (Optional)BP-AA,BP- SBS-AA,SBS-
Structural ASTM PSI,R-Panel 25 PSI ENRGY 3 AGF or CGF Min.0.25-Inch SECUROCK
C-3. concrete D41 ENRGY 3 25 PSI AGF or CGF,ValuTherm AGF HA Gypsum-Fiber Roof Board HA SBS-CA2 or 565- CA2,S ,SBS•CA2 CA2 or SBS- 247.5
or CGF,ValuTherm 25 PSI AGF or CGF TA or SBS-TA
AA TA TA
Min.0.5-inch Retro-Fit Board, BP-AAA BP-CA2, SBS-AA,SBS-
Structural ASTM Min.1.5-inch ENRGY 3 CGF,ENRGY 3 25 PSI RetroPlus Board or (Optional)BP-AA,SBS-
eW concrete D41 CGF,ValuTherm CGF,ValuTherm 25 PSI CGF HA DuraBoard or min.0.75-Inch HA SBS-AA or SBS- AA SBS-CA2 or SBS-TA CA2 or SBS- -277.5 �—
Fesco Board CA2 TA -
Structural ASTM (Optional)Min,1.5-inch ENRGY 3 CGF, Min.1.5-Inch Fesco Foam or BP-AA,BP-CA2' (Optional)BP-AA,SBS- SBS-AA,SBS-
C-5. ENRGY 3 25 PSI CGF,ValuTherm CGF, HA HA SBS-AA or SBS- AA SBS-CA2 or SBS-TA CA2 or SBS- -277.5
concrete D41 ValuTherm 25 PSI CGF DuraFoam CA2 , TA
C-6, Structural ASTM Min.1.5-inch ENRGY 3 CGF,ENRGY 3 25 PSI HA Min.0.5-inch DuraBoard HA SBS-TA (Optional)SBS-TA 5BS-TA -277.5
concrete D41 CGF,ValuTherm CGF,ValuTherm 25 PSI CGF
Min.1.5-Inch ENRGY 3,R-Panel,ENRGY 3 25
C 7 Structural ASTM PSI,R-Panel 25 PSI,ENRGY 3 AGF,ENRGY 3 HA Min.0.5-inch DuraBoard HA 5135-TA (Optional)SBS-TA SBS-TA -300.0
concrete D41 25 PSI AGF,ValuTherm AGF,ValuTherm 25
PSI AGF •
Min.1.5-inch ENRGY 3,R-Panel,ENRGY 3 25 BP-AA,BP-CA2, SBS-AA,SBS-
C 8 Structural ASTM PSI,R-Panel 25 PSI,ENRGY 3 AGF,ENRGY 3 HA Min.0.5-Inch RetroPlus HA SBS-AA or SBS- (Optional)BP-AA,SBS- CA2 or SBS- -30010
concrete D41 25 PSI AGF,ValuTherm AGF,ValuTherm 25 Board or DuraBoard CA2 AA,SBS-CA2 or SBS-TA TA
PSI AGF
Min.1.5-Inch ENRGY 3,R-Panel,ENRGY 3 25 Min,0.5-inch Retro-Fit Board BP-AA,BP-CA2, SBS-AA,SBS-
C 9 Structural ASTM PSI;R-Panel 25 PSI,ENRGY 3 AGF,ENRGY 3 HA or min.0.75-Inch Fesco Board HA SBS-AA or SBS- (Optional)BP-AA,SBS- CA2 or SBS- -305.0
concrete D41 25 PSI AGF,ValuTherm AGF,ValuTherm 25 or DuraBoard CA2 AA,SBS-CA2 or SBS-TA TA
PSI AGF
(Optional)Min,1.5-Inch ENRGY 3,R-Panel, BP-AA BP-CA2, SBS-AA,SBS-
Structural ASTM ENRGY 3 25 PSI,R-Panel 25 PSI,ENRGY 3 Min.1.5-Inch Fesco Foam or ' (Optional)BP-AA,SBS-
C-10. concrete D41 AGF,ENRGY 3 25 PSI AGF,ValuTherm AGF, HA HA DuraFoam or SBS- AA SBS-CA2 or SBS-TA CA2 or SBS 305.0
CA2
ValuTherm 25 PSI AGF CA2 TA
Exterior Research and Design,U.C.d/b/a Trinity(ERD Evaluation Report J8230.03.08-R10 for FL2948-Rll
Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 10:10/13/2016
Prepared by: Robert Nleminen,PE-59166 Appendix 1,Page 22 of 52