HomeMy WebLinkAboutProduct Approval (2) If^
f�
Florida Building Code Online �a R+� to age 1 of 2
lift
• I , w
If * s 3+� deal
BCIS Home Login i User Registration Hot Topics Submit Surcharge Stats&Facts i Publications FBC Staff z BCIS Site Map Links Search
Product USER:Publics User
rOVal
Product Approval Menu>Product or Application Search>Application List>Application Detail
n
iflYII ° 7 ' FL# FL11475-R6
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer Johns Manville
Address/Phone/Email P.O. Box 5108
Denver,CO 80217
(303) 978-4879
codes@jm.com
Authorized Signature Vanessa Indarte-van der Plaat
codes@jm.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Single Ply Roof Systems
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
® Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 06/23/2019
Validated By John W. Knezevich,PE
Csi Validation Checklist-Hardcopy Received
Certificate of Independence FL11475 R6 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year (of Standard) Standard Year
ASTM D6878 2008
FM 4470 1992
FM 4474 2004
TAS 114 2011
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv8JygqZ9 WuE... 3/13/2017
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 04/30/2015
Date Validated 05/01/2015
Date Pending FBC Approval 05/08/2015
Date Approved 06/22/2015
Summary of Products
FL# Model, Number or Name Description
11475.1 JM TPO Single Ply Roof Systems Polyester scrim reinforced, thermoplastic polyolefin,single-
ply roof systems
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11475 R6 II 2015 04 FINAL Al ER JM TPO FL11475-
Approved for use outside HVHZ: Yes R6.Ddf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-367.5 Created by Independent Third Party: Yes
Other: 1.)The Design Pressure noted in this application Evaluation Reports
relates to one specific assembly in the ER. Refer to the ER FL11475 R6 AE 2015 04 FINAL ER JM TPO FL11475-
Appendix for other systems and Design Pressures. 2.)Refer R6.pdf
to ER Section 5 for Limits of Use. Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
Credit Card
Safe
l�
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv8JyggZ9 WuE... 3/13/2017
Attachment#3 Low Slope TPO alternative assembly for all
buuildings...1, 2, 3, & 4
TRINITY i ERA
TABLE 6A: RECOVER APPLICATIONS
SYSTEM TYPE A: BONDED INSULATION,BONDED ROOF COVER
System Substrate Base Insulation Layer Top Insulation Layer Roof Cover MDP
No. (see Notes 1&12) Type Attach Type Attach Type Attach (psf)
�`a•vI ,.s:..., r s"�q ,.
k?�°:Pi��i � li,�i', -
ii'f t ti+� k: d.,iem }.. lfp} 'i1� sL`ns ��Aacw�,. ;��Y..�' � _hry�+L�G:�'rYm7�&i�:•t..,.�. • 7? ,.fib' r�l
(Optional if coverboard used)Min.1.5-inch ENRGY 3,ENRGY 3 AGF, -�
(Optional if base insulation used)Min. JM TPO 45, JM TPO MA-WB,JM j
Existing ENRGY 3 CGF,PSI-25,ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI CGF,JM UTA-TWO- UTA-TWO-
R-1 0.25-inch DensDeck or Invinsa Roof 60,72 or TPO MA-SB or TACC -105.0
asphaltic BUR ISO 3,ValuTherm,ValuTherm AGF,ValuTherm CGF,ValuTherm 25 PART Board or min.1.5-inch Invinsa Foam PART 80 FA-141
PSI AGF,ValuTherm 25 PSI CGF
(Optional)Min.1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,PSI- 1M TPO 45,
R 2 Existing 25,ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI CGF,JM ISO 3,ValuTherm, UTA-TWO- Min.0.25-inch Invinsa Roof Board or UTA-TWO- 60,72 or JM TPO WBMA 105.0
asphaltic BUR ValuTherm AGF,ValuTherm CGF,ValuTherm 25 PSI AGF,ValuTherm PART min.1.5-inch Invinsa Foam PART 80
25 PSI CGF
Min.1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,PSI-25,ENRGY 3 1M TPO 45, JM TPO MA-SB,JM
Existing UTA-TWO- (Optional)Additional layers of base UTA-TWO- TPO MA-LVOC,JM °
R-3 25 P51 AGF,ENRGY 3 25 PSI CGF,JM I50 3,ValuTherm,ValuTherm 60,72 or -120.0 =�a
asphaltic BUR AGF,ValuTherm CGF,ValuTherm 25 PSI AGF,ValuTherm 25 PSI CGF PART insulation PART 80 TPO Low-VOC MA
or TACC FA-141
Existing MBR-BA(full JM TPO 45, JM TPO MA-WB,JM
R-4 Min.0.25-inch Invinsa Roof Board coverage at N/A N/A 60,72 or TPO WBMA orJM -112.5
asphaltic BUR 1.5gal/sq) 80 TPO MA-SB
,(Optional if coverboard used)Min.1.5-inch ENRGY 3,ENRGY 3 AGF, (Optional if base insulation used)Min. JM1P.Q'45, JM TPO.MA-VIIB,JM
'Existing ENRGY 3 CGF,PSI-25,ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI CGF,JM
R-5 JM-OSFA 0.25-inch DensDeck orinvinsa Roof JM-05FA 60,72 or TPO MA-SB or TACC -75.0
asphaltic BUR ISO 3,ValuTherm,ValuTherm AGF,ValuTherm CGF,ValuTherm 25 Board' 80 FA-141
PSI AGF,ValuTherm 25 PSI CGF
(Optional if coverboard used)Min.1.5-inch ENRGY 3,ENRGY 3 AGF, JM TPO 45,
R-6 Existing ENRGY 3 CGF,PSI-25,ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI CGF,JM JM-OSFA (Optional if base insulation used)Min. JM-OSFA 60,72 or JM TPO WBMA -75.0
asphaltic BUR ISO 3,ValuTherm,ValuTherm AGF,ValuTherm CGF,ValuTherm 25 0.25-inch Invinsa Roof Board 80
PSI AGF,ValuTherm 25 PSI CGF
Existing .
asphaltic BUR JM TPO 45, JM TPO MA-WB,JM
R-7 or mineral Min.0.25-inch DensDeck CR-20 N/A N/A 60,72 or TPO MA-SB or TALC -105.0
surface cap 80 FA-141
sheet
Existing
asphaltic BUR Min.1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,PSI-25,ENRGY 3 JM TPO 45,
R-8 or mineral 25 PSI AGF,ENRGY 3 25 PSI CGF,JM ISO 3,ValuTherm,ValuTherm CR-20 (Optional)Additional layers of base CR-20 60,72 or M A TPO Low VOC -172.5
surface cap AGF,ValuTherm CGF,ValuTherm 25 PSI AGF,ValuTherm 25 PSI CGF insulation 80 M
sheet
Existing
asphaltic BUR Min.1.5-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,PSI-25,ENRGY 3 JM TPO 45, JM TPO MA-SB,JM
R-9 or mineral 25 PSI AGF,ENRGY 3 25 PSI CGF,JM ISO 3,ValuTherm,ValuTherm CR-20 (Optional)Additional layers of base CR-20 60,72 or TPO MA-LVOC or -217.5
surface cap AGF,ValuTherm CGF,ValuTherm 25 PSI AGF,ValuTherm 25 PSI CGF insulation 80 TACC FA-141
sheet
Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report F9340.10.08-R6 for FL11475-116
Certificate of Authorization#9503 Revision 6:04/30/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 20 of 23
G"":-.--F-"--•-ate .>v�-rr r�'^'t's.,^T" ^^ra.�'�'-.'e-."
��.
t
i' ,-'^,-f
I
Y, u.
johnsManville
44``c -"�tx; .t �*�,¢Y'�? rt�'C�yc"'s'7,✓�`` w'�s'"�.�sA'.'���±�yU.,. ��i a���`��q„#` A«�� y�-� .a�r� Y€'� �i'`��y�s�,.�-��§b��s'� �r�ry�,����
Features and Components
Use: JM One-Step Foamable Adhesive is a two-component Color. Part 1-Tan, Part 2-Colorless AD
polyurethane adhesive used for attaching insulation or cover Adnesve
boards to the roof deck or to other insulation boards. Features: Solvent and VOC free.
Set boards immediately into adhesive;reduces Typo
Type: Two-part,cold application insulation adhesive. installation time and maximizes adhesive footprint
Substrates:Compatible with the following insulations,cover boards,and No hoses or pumps required. insulation
substrates:polyisocyanurate;HD wood fiber,perlite;Invinsa® Always on ratio,eliminates guesswork.
Roof Board;gypsum;concrete (Lightweight structural,poured- B
in-place structural,precast and insulatingrtreated plywood(W Cover Board
f1.58cm1min.thicknessr cementitious wood fiber plank;base Mum-Ply
sheets;gypsum;and some existing smooth-surfaced Single Ply
asphalt(per inspection).
1.Drying time of 28 days required
System Compatibility This product maybe used as a component in the following systems.Please reference product application forspecific installation methods and information.
,PP •t
j Used to adhere Insulation in all Multi-Ply systems Used to adhere Insulation in all Single Ply systems
Key: HA= Hot Applied CA=Cold Applied HW=Heat Weldable SA=Self Adhered MF=Mechanically Fastened FA=Fully Adhered BA=Ballasted
Energy and the Environment Installation/Application
Physical Properties
ASTM Bead
Property Test Weight Part 1 —Method 9.6 lb/gal art k IA -Apply when ambient temperature is 0°F(-18°C)and rising.Do Not Thin.
Ensure all insulation boards are 4'x 4'0.22 m x 1.22 m)or smaller.
(liquid components) Part 2 — 8.35 lb/gal(1.0 kgA) •Ensure all surfaces are dry and free of any debris,dirt,oil and grease
Viscosity Part 1 — 5,000 cps before using JM One-Step Foamable Adhesive.
(liquid components) Part 2 — 3,700 cps •Referto the application instructions and guidelines for proper
utilization and coverages rates ofthis adhesive.
Precautions Packaging and Coverage
3.} �k �''"`z' - Case
1 a
4 cartridges/case with 6 mixing tips
17.8Ib(8.1 kg)
ir. r[` W^"! ➢.6't . d uF ice. Q' yYh3t" SE
1; ���� 48
,;? ^..������'q ,,. .+�a,°"im" ��a.'*� z%�. ,'.,1. „e.r k;,a „IL'� 1;�'-'� :,Y-:`��� .r►:;..�F.
mod . R� F
12"o.c. 400 to 600 ftz 253 to 379 0.26 to 0.40
6"o.c. 200to300ft' 126to190 0.52to0.80
1 - a 4"O.C. 133 to 200 ftz 84 to 126 0.78 to 1.2
Coverage rates are approximate and mlyvarybased an substrate type and application.
Approved substrates include structural concrete decks,JMVaporBarderSA,ENRGY3,Bet
-
roPlus,DuraBoard,Invinsa,Securock,DensDeck,DensDeck Prime,smooth modified asphalt
membranes and granulated asphalt membranes.Please contact JM Technical Services for
other approved substrates.
Storage
SFta ,t/fe, � 12 months from manufacture date
Rrds Clean,dry,well-ventilated indoor environment in
Sti(irag� l�n�s an unopened container.24 hours priorto use,store
between 60°F(16°C)and 85°F(290C).
Refer to the Safety Data Sheet and product label prior to using this product Tgtn arRsng 45°FtD 95°F(7°Cto 35°C) Protect from freezing
The Safety Data Sheet is available by calling(800)922-5922 or on the Web at
www.im.com/roofing. RS-7374 10-14(Replaces 11-13)
wf+�WXE
johnsManville
,Cet� _.� �}�c- � 2�,.w„�7u.'C`"xr+y t, ad.- s� �.SG "+T" I�'`as '�§'�n^-�:s � 4 Y � 3• j'3r'%���3 c �„�-, c:
3�-�rh �r" �, sa�ax-w�, ry�`3��'�e'°S+�K � �ar�-•n�'i �+. `` .ri .r'�'#''n a s+ y�` y i
Meets the requirements of ASTM C 1289,Type II,Class 4,Grades 1,2 and 3
Features and Components
High-Density Polyisocyanurate Foam Core:Closed cell
polyisocyanurate foam technology provides additional insulation RI .. multMj
value,with lightweight and low water absorption characteristics. 'S= rfs' +emsst Single Ply
Mineral Coated Fiber Glass-Reinforced Facers:Bonded in-line to r<� _ t ' w;e ,° Type
the polyisocyanurate foam core to provide a smooth,strong surface ram; > 'r
for better membrane adhesion withoutthe need for priming,with d " High Density PF
P 9 'Ts�.t - _— Polyisocyanurate Poly Foam
enhanced water resistance that will not support mold growth. Foam �'•
Lightweight Offers labor and installation efficiencies and allows more ,.,_ Mineral-Surfaced, L
,� rr A�,��. -� ��� y�,5 Fiber Glass-Reinforced to,,,Themel
r� ��� �� Facers
options for situations where the overall weight is a concern.This also u, s '
means easyhoisting,staging and maneuvering around the roof. � � g
9 9 9 9 „u H
=� k . tr; ,3'
Flexibility:Means less breakage during handling,and in re-cover ` High oeuiry
applications it allows Invinsa to accommodate minor irregularities in
PP 9
existing roofs.
User Friendly:Invinsa allows easy&efficient scoring,cutting and
snapping which permits fast,tight fabrication and all in a low dust
environment
Resistance To Damage:High impact,flexural and compressive
strength provides a protective layer for insulation while working with
the membrane above to ensure maximum performance and longevity.
System Compatibility This product maybe used as a component in the following systems.Please reference product application for specific installation methods and information.
F. Compatible with the selected Multi-Ply systems above Compatible with the selected Single Ply systems above
Key: HA=Hot Applied CA= Cold Applied HW=Heat Weldable SA=Self Adhered MF=Mechanically Fastened FA=Fully Adhered BA=Ballasted
Energy and the Environment Ilnstallation/Application
NNW�' Pre-Consumer.3.7%
U r. , „ = m Past-Consumer:0%
Peak Advantage®Guarantee Information Cold Applied Urethane Mechanically
I-j�yE� r� _ � .,�� 11 AM MARROW
ROW k}_} Adhesive Fastened
When used in most JM multi-ply or single ply systems I 10,15 or 20 years Refer to the Application Guides and Detail Drawings for instructions.
Contact JIM Technical Services for specific systems or terms over 20 years. Packaging and Dimensions
Codes and Approvals 4WIX111Sr_ -Vl 4'x4'xAa 4'x8'xA"
(1.22mx1.22mx6.35mm)(1.22mx244mx6.35mm)
`gyp u F�Fa F M Y y 6 Ib(272 kg) 12 Ib(5.4 kg)
O nuvawAD a Cau V '..
t "�('y 480 ftz 960 ft2
C D$ Mfem40eda Coumy � M`F'i
APPROVED P,,dua Con olAppmwed �� r "v 30 30
if Et s 185lb(83.5 kg) 370lb(167 kg)
f�tlts, INN ' 192 96
a?rodtiIg Cornwall,ON and Jacksonville,FL
Assumes 48'flatbed truck.
Referto the Material Safety Data Sheet and product label priorto using this product
The Material Safety Data Sheetis available by calling(800)922-5922 or on the Web at
www.im.com/roofing. RS-5500 4-14(Replaces 2-14)
JohnsMan
r ��5s .f �rf .tl vri' " e�° �; V4tF�7.l �,t' • Juan ��- v. ��
fi .
air, ., f% a,suk �° 7 spa£ aw nr k � �� sa ,rx
Meets the requirements of ASTM C 1289,Type II,Class 4,Grades 1,2 and 3
Typical Physical Properties
Invinsa Roof Board
Compression Strength D 1621 150 psi(1,034 kPa)
It
Flexural Strength
Modulus of Rupture D 1037 1500 psi(10,343 kPa)
Breakload 25 Ibf(0.111 kN)
Dimensional Stability,Linear Change D 2126 <0.6%
Moisture Vapor Permeance E 96 <t perm(<57.5 ng/(Pa•s•m2))
Water Absorption,%by vol(max) C 209 2.0
d Surface Water Absorption C473 <1 gram
Mold Resistance D 3273 Pass
Weight per ftz N/A 0.375 lb-ftz(1.83 kg-ml)
Weight per board(4AI N/A 12 lb
Thermal Performance
Thickness Nominal R-Value(Resistance)
6.35 I 1.2 0.21
Refer to the Material Safety Data Sheet and product label prior to using this product
The Material Safety Data Sheet is available by calling(800)922-5922 or on the Web at
www.jm.com/roofing. RS-5500 4-14(Replaces 2-14)
� _ � _-.r ry,x'•'� Z'33-��-.' r. � ��� .r S� `� 5 i e' r �. z �
�1 � 1's tti-.:` s.�'`$t�.l ��-� �1 T �+�-� �r '-•: �
..T��-�,--,- P*-.-s- �. i7�' .-w ,.r 't yr r •}' '-` -z' �a--t4 f
Y.✓c T .-^ateI WE
---^ rx# 12x 'N - d
N am
t ✓ �*�' s g r- :-:fast is. •:- �', fs e--,.r
johnsManville
IN
MR
Features and Components eM
Use: For adhering JM TPO membranes to approved substrates. Adheave
Limited availability from October 1st to April 15th. ---
See Bulletin T13-007-dated May 23,2013 for additional information. Mir, Type
Type: One-part,water based membrane adhesive. " M
s o with approved insulations and cover boards
Substrate •.Compatible ati a bl ,
and concrete decks. _ Single Ply
Colors: Bright blue when wet,and dark green when ready to
adhere.See Installation/Application for a visual guide
to colors.
System Compatibility This productmay be used as a componentin the following systems.Please reference product application forspecific installation methods and information.
Do not use in Multi-Ply systems Used to adhere Membranes in the selected Single Ply systems above
Key: HA= Hot Applied CA=Cold Applied HW=Heat Weldable SA=Self Adhered MF=Mechanically Fastened FA=Fully Adhered BA=Ballasted
Energy and the Environment Installation/Application
_ ksnt � <10 g/I(Calculated)
This product maybe used injudsdictianslimitingVOC(volanle organic compounds)contentof
single ply roofing adhesive to no greaterthan 250 gll.
Physical Properties Med.Nap Roller wet Readyto Adhere
• Apply when the ambient and substrate temperature will be above
JM • Water BasedV F(40 C)and rising for 48 hours.
Property Weight per Unit(approx) Membrane lb/gal(0.990 kg A) • This is a 2-sided adhesive when applied in a vertical application.
g When used in a horizontal application with smooth-backed or
Specific Gravity 0.99 fleece-backed membrane apply one-sided.When using one-sided
application apply to substrate only.
Precautions • Refer to the application instructions guidelines for proper
utilization of this adhesive.
Packaging and Coverage
18.91 ail
r Qv �
5 gal 1 1p
461b(20.9 kg)
't '�,m'' , '
�+��k »Tsr_R I`y�.v
Substrate Membrane Total Installedfe/gal
rn o m ENRGY3® 120.160felgal Offlgal .120-160fe/gal(2.95-3.930111
�'o't Invinsa® 140-160fl/gal 0fO/gal 140-180fe/gal(3.44-4.42rTfA)
c=H JM®SECUROCK® 130-170fe/gal 0ftt/gal 130-170 fe/gal(3.19-4.17 OA)
c Sub ate* Membrane Total Installedfe/gal
y m ENRGY3' 240-320fl/gal 240-320ff/gal 120-160f['/ga11295-3.93m'AI
icy Invinsa° 280-360ftl/gal 280-360fl/gal 140-180feigal(144-4-42m'AI
~ JM®SECUROCKa 260-340fN/gal 1 260-34ff?/gal 1 130-170fl/gal(3.19-4.17m'A)
1.Coverage,open and drytime rates can vary dramatically depending on the particular substrate and
environmental conditions.Coverage rates stated herein are approximate only.If FM GlobaPor UV approval
is required,consuhspecific RoofNav-arthe UL Certifications Directoryfor speck application rates.
Storage
12 months from manufacture date
CnridtGos Clean,dry,indoor environment in an unopened container
zTertr>ttuFe a 60°F-80°F(16°C-27°C)-Protect from freezing
Exposure Window
SECUROCV is registered trademark of United States Gypsum Company.SECUROCKa is manufactured by Johns Manville recommends immediate and complete use upon
United States Gypsum Company and is marketed by Johns Manville as JM°SECUROCV.
opening.Use open containers within 48 hours of opening.Replace
Refer to the Safety.Data Sheet and product label prior to using this product. lid on can when not in use.Adhesive that has changed color or
The Safety Data Sheet is available by calling(800)922-5922 or on the Web at viscosity is no longer usable.
www.jm.com/roofing. RS-7823 2-16(Replaces 9-15)
f. r r KY vC G~
,�., .,,� p _ 9E..heW
N. q
y s ry jt ,° ° �+--i �2-``Y.f'X.`kc= y .''�r -... 5 ai.d' ' "�rti2'4• 1{..` �F" r. i
,} > 4��.5+T fr"Q y± «+ ���r,,gcaru, -. r�ar�Lpv'71t.r�. /�t� 3a'?
7+r r ps ,t�Y`r s s ' i G� tvE � 1✓ "� � V r:l �V tSM10
JohnsManville
't'
Meets or exceeds the requirements of ASTM D 6878
Features and Components M
Memhrane
Thickness Over Scrim:Optimized and tested on a continual basis
with a state-of-the-art thickness gauge to verlfythatthe thickness Single Ply
valued by our customers is incorporated into the sheet
F
One of the Widest Melt Windows:Promotes better welds over a -
wider variety of speeds and temperatures,and leads to a softer, k'. .
more flexible and workable sheet 4
Reinforced fabric scrim layer and top-ply thickness:Lends to :� 7
durable physical properties including:
� z �
• Long-term weathering,UV resistance and heat-aging properties
• High breaking and tearing strength Colors
Optimized TPO formulation:delivers high-performance ozone
resistance,cool roof reflectivity and overall weather resistance. *Grey and Tan lead times are subject to availability and may require
an upcharge forsmallerprojects.
System Compatibility Thisproductmaybeusedasacomponentinthefollowingsystems.Pleasereferenceproductapplicationforspecificinstallationmethodsandinformation.
Do not use with Multi-Ply systems a Compatible with the selected Single Ply systems above
Key: HA=Hot Applied CA=Cold Applied HW=Heat Weldable SA=Self Adhered MF= Mechanically Fastened FA=Fully Adhered BA=Ballasted
Energy and the Environment Q Installation/Application
White Initial 0.77 0.07 w�
r 3YrAged 070 086
Fully Adhered Mechanically Hot Air Weld
Fastened
�* Referto JM TPO application guides and detail drawings
White Pass 0.77 0.87 for instructions.
White Initial 0.78 087
P 3Yr Aged 068 Packaging and Dimensions'l-at!
5 1.52 m 8' 2.44 m 10' 3.05 m
75'(22.86 m)
x White Initial 101 `'
3 Yr Aged 85r y ti 375 ftz(34.84 mz) 600 ftz(55.74 m') 750 ftz(69.68 mz)
8
g
1,3841b(627.8 kg) 2,2101b(1,002 kg) 2,760 Ib(1,251.9 k )
} Pi>EAetruck" 36 24 1 16
Post-consumer 0% Scottsboro,AL
II€ r Post-industrial 5% *Assumes 48'f lathed truck and does not reflect pallets of accesso6es or impact of mixed sizes.
The LEEDO Solar Reflectance Index(SRI)is calculated per ASTM E1980.
Peak Advantage°Guarantee Information
Product 5t71112 ^ >' _' '�ya08ratrtee�etm 4
JM TPO 80 5,10,15,20,25,or 30 yrs
Codes and Approvals
G�PSSIf��o
F M M{AMrD{1DE COUNiY
U � Refer to the Safety Data Sheet and product label prior to using this product.
CMiarni-Dado County
US 11PPROVED Produn Control ApProved The Safety Data Sheet is available by calling(800)922 5922 or on the Web at
www.im.com/roofing.
RS-8634 1-16(Replaces 9-15)
ag
me
-F.r { a.' .y i - f aJ' �' 1a,'" '��` f a ,qt'x, +F qq
€' tom`,,Ig
t "" 'x 4
5 .as•-�'AIN�, cr,, t ":"tT, ` 'dot -'#'3'•F»�.43r,' ,s: .,tI Op
.r rr 'a �+ 'sa .r• ,.�.,_.� ,,w ,.,,.
aT
or 4
*.s"si
Meets or exceeds the requirements of ASTM D 6878
Tested Physical Properties
ASTM Standard for JMTPO-80mil
PropertiesPhysical „ ASTM 1 , 1 1
Breaking Strength,min,Ibf(N) D 751 220(976) 464(2,064) 439(1,953)
Elongation at Break,min% D 751 15 29 31
f
i Tearing Strength,min,IV(N) D 751 45(200) 65(289) 179(796)
Factory Seam Strength,min,Ibf(N) D 751 66(290) 137(609)
Thickness,min,in. D 751 +/ 10%from Nominal 0.080(Nominal)
Thickness Over Scrim,min,in.(mm) D 7635 0.015 0.033(0.84)
Water Absorption,max,% D 471 3.0 0.03
.= Brittleness Point,max,-40°F 02137 No Cracks Pass
Ozone Resistance D1149 No Cracks Pass
Properties after Heat Aging @ 240°F D 573 Pass/Fail Pass
Breaking Strength,%(after aging) D 751 90 >90 >90
Elongation,%(after aging) D 751 90 >90 >90
Tearing Strength,%(after aging) D 751 60 >60 >60
L Weight Change,max,%(after aging) D 751 ±1.0 0.22
Linear Dimensional Change,max,%(after 6 hrs @ 1581) D 1204 ±1.0 <0.1
E Accelerated Weathering,min G 151&G 155 10,080 kjJmz•nm®340 nm >20,160 kj/mz
(4,000 hrs®0.70 W) (>8,000 hrs)
Cracking(®7x magnification) G 155 No Cracks Pass
MD Machine Direction
`•XMD=Cross-Machine Direction
Note:All data represents tested values.
Supplemental Testing
StandardASTM 1 i mil
Physical Properties 1 6878(Min.) Result
Dynamic Puncture D 5635 N/A Pass®25 Joules
Static Puncture D 5602 N/A Pass®44 lb(20 kg)
Impact Resistance of Bituminous Roofing Systems 03746 N/A Pass-minor indentations
Reflectance C 1549 N/A 78%
Emittance C 1371 N/A 0.87
Resistance of Synthetic Polymer Material to Fungi G 21 N/A 0 rating
Puncture Resistance(FTMS 101C,Method 2031) N/A N/A 526lb(239 kg)
Moisture Vapor Transmission E 96 N/A 0 g/mz per 24 hours
Hydrostatic Resistance,Mullen D 751 N/A 474 PSI(3268 kPa)
Refer to the Safety Data Sheet and product label prior to using this product
The Safety Data Sheet is available by calling(800)922-5922 or on the Web at
www.im.com/roofing. RS-8634 1-16(Replaces 9-15)
�s x" ct ,'� �v��3� � �"'a �' �a�,,, 4f•_ ice' �. �- �'.
t AIL
�'��'� -�w,�{.x.�'k.y'R'yi'wPke � d`� "� v;4 .rti a.:Y 'r' �:'c +�— z ,�,��.2u c ����:rh -� •.
Is
;in
M7
!,;' s � t sad
v- .� *f'S`� rid a."�` "#_ �,�"�'v,`�`'' .� 'r 1 g. .ry�a.�. � �€ £ s� ;�'Y
X............
�-, �4"' c3r ,krsR"�.x,9. �'S"r v -'fir-� '+> f �. zx .y7�-
1`5 3r x "r�'.' 2 x" �' ,� ',r,F . ss may+
f'Fr k.�- R.
� �.`'r ..SC }a� :i'q Y .y x.a— tJohns Man
Mry,;�p`py..�s4 .r-
RIAV
RAVI
�„�§�. � "„ #
Features and Components Component
JM EPDM Lap Caulk 4'(10.16 cm)Nailing Flange,Galvanized
JM EPDM Metal/Membrane Flashing is a specially designed and JMEPDMLapCement 6'11524 cm)
JMEPDMStrip Specialty
manufactured flashin for sealin and water roofin JM EPDM JM bravePDM oflng S rippedCours Flashing
9 9 waterproofing Membrane Stripped-In Mulfi-Ply
roofing systems where they join an adjacent bituminous roof Single Ply
membrane. ripe
Materials:A nominal 6"(15.24 cm)strip of black JM EPDM
membrane secured to flanges of nominal 4"(10.16 cm)
wide galvanized steel. Insulation -=-
Treated Wood Nailers
and Cant Stdp '=- _ Industrial Roof Cement
_:---` Existing Built-Up
Roofing Membrane
Nailing T to 4'
15.08 cm to 10.16 cm)O.C.
with Min.;V(9.53 mm)Head
* Product to be used at transition from TPo roof
system to PMMA roof system. See attached detail
next page.
System Compatibility This product maybe used as a component in the following systems.Please reference product application forspecffic installation medlods and information.
-BUR APP
SBS
Campadble with all Multi-Ply systems Compatible with the selected Single Ply systems above
Key: HA= Hot Applied CA=Cold Applied HW= Heat Weldable SA=Self Adhered MF=Mechanically Fastened FA=Fully Adhered BA= Ballasted
Energy and the Environment Installation/Application
/a a • Do not install EPDM membrane in direct contact with asphalt or
0
a 0% coal tar pitch.
• Refer to JM applicator guides or detail drawings for instructions.
Peak Advantage®Guarantee Information Packaging and Dimensions
Covered under the JM Peak Advantage Guarantee when installed in a 6"(15.24 cm)
JM approved roofing system. -r �" ` �s
Y 4„(10.16 cm)
100[in ft(30.48 lin m)
< e ;�>?rapp 65 lb(29.5 kg)
Lewiston,ME
Storage
Stier j f r 12 months from manufacture date
Da gtFs �<.
Store indoors,out of direct sunlight
Tein rar filiEsRange r 60-Fto 80°F(16°C to 27°C)
Refer to the Safety Data Sheet and product label prior to using this product.
The Safety Data Sheet is available by calling(800)922-5922 or on the Web at
www.m.com/roofin . RS-8147 10-14(Replaces 8-13)
1 9
r
:': ::::::':::`:::::::: ::::..
is ... .? :': : � : ::::: : :� ........
.................' :::'::::':::;'::::;:::::::::::::'::'::':::::::'.................................................
' ' ' ' '' ' ':..
At7#3
::.:::.:::::•:';::•:'::•;:•::::;';::;•;::::;;::•:::::::::.::.:.:.:.::::::::.::.:.:•::.::.:::::::::::.::::::::..,...............................................................................
:•:;•:::'::::.;:•:::•::•::•:;:.::•:::::.::::•:::•::.;:':.:::•::::.::•::.:'::•::': :::.........:........... ....................
:::::::.} +:: :: +Ate'::•::..............................::.: .:.:.........
.............
...
..
:::::•:::.::::::::•.::::::':.::.:.:. .. ............
.;:':::.:.:•:...........:.........•..................•....................•:::.....:............,...::::.:::::.::::MEMBRANE.:.• 'Sf iLi�IG::::.:::::..:::::•::•: ...............••:.::.::::::::... 8
...... .. .... • .::.:.:.:.:.::.:••::.:::::• ...:::.::::::::::::. :•::.: •:.:•
:::.:.::::.:::::::::•:.::.:::•::::•:•.::::::::...:.......::::SFI.DE1... Ti? ...................................::......:.::.::.:.:.:._:.::::.::.:• ..::::•::.::.::::.-:::::..' ::::::' 2i� Ali
x.r.
�L
vx--
_
.:.�.:�.Y.YSL'L'.'��'�C '.':::.•'. H.
............................................ ....
C:•
TP
..:::.�...�....ill:A;:In�............:'.'..'.:'.'.':.':.:•':.'::.'• ........'...:'::.'..'...........'.:.....'•:::: ...l•. .:�: :ti,------------
p•\ '
......:�::::::::::.�:::.�::
;.::TARS:Pfi i� .......:.`:•%'' ,;:..
::::....:::::................. . CAP FLASHING IN
C11 '- -: �FT� MBR UTILITY CEMENT
................:
: . ':•.
�o ...... ::.::.. APPROVED BACKER PLY
9'Qp IN BR UTILITY CEMENT
9`s'-QF NAILS 4"0. AGGERED
P
G�Fp JM ASPHALT PRIMER
BiTG JM MBR UTILITY CEMENT
00 oGs JM APPROVED FASTENERS
L�•I'e �oo� AND PLATES- PENETRATION
WOOD BLOCKING AS DEPENDANT ON DECK
REQUIRED SECURELY 1'9s
p -QF TF�i OR FURTHER SEE SPECS
FASTENED TO DECK INFORMATION
pG�
PR -�Fp J��OJ
o�Ep 0�
OFF
. k
NOTES:
1. REFER TO JOHNS MANVILLE WEBSITE(www.jm.com) FOR MOST UP-TO-DATE INFORMATION.
2. PLEASE SEE SINGLE PLY FLASHING SPECIFICATIONS FOR A FULL DESCRIPTION OF INSTALLATION
INSTRUCTIONS AND.REQUIREMENTS WHICH ARE CONSIDERED A PART OF THIS DETAIL.
3. ANY CARPENTRY OR METAL WORK SHOULD BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH
LOCAL CODE REQUIREMENTS AND/OR PROJECT SPECIFICATIONS.THESE COMPONENTS SHOULD BE
REVIEWED AND APPROVED BY A LICENSED DESIGN PROFESSIONAL.
4. DETAILS TO BE USED IN CONJUNCTION WITH GUIDE SPECIFICATIONS CONTAINING REQUIREMENTS FOR
NAILERS,INSULATION,ETC.
5. ON RE-ROOF OR RECOVER PROJECTS,VENT PIPES MUST BE CLEANED OF LARGE DEPOSITS OF ASPHALT.
ALUMINUM TAPE IS WRAPPED AROUND THE PIPE AS A SEPARATION LAYER. NEW ASPHALT-COATED CAST
IRON PIPES MUST BE WRAPPED WITH ALUMINUM TAPE.
6. JM EPDM TAPE PRIMER MUST BE APPLIED ON ALL SURFACES COMING INTO CONTACT WITH JM EPDM PEEL&
STICK FLASHINGS. ROLL MEMBRANE WITH HAND ROLLER UNDER PRESSURE AT SEAM.
7. 1/6"TO 1/4"OF EPDM SEAM TAPE MUST BE EXPOSED ALONG ENTIRE LENGTH OF ALL SEAMS.
8. ALL SEALANTS/CAULKING SHALL BE PERIODICALLY INSPECTED AND MAINTAINED BY THE BUILDING OWNER
THROUGHOUT THE LIFE OF THE ROOF.
DRAWING NO. TIE IN - BITUMINOUS TO EPDM
E- • '-O3 MEMBRANETYPE: Johns Manville is a manufacturer of commercial roofing products and offers this general conceptual
REPLACES EM-6B JM EPDM information to you as a courtesy.This complimentary assistance is not to be used or relied upon by
anyone as a substitute for professlonal engineering design and documentation required by building
SCALE ISSUE DATE MAXIMUM GUARANTEE TERM: rode,contract,or applicable law.By accepting these comments you agree the yy do not constitute any
representations,endorsements of,or an assumption by Johns Manville of any liabilitdyy for either the
N.T.S 1-2-15 20 YEAR adequacy of the design of this building or any other material not supplied by Johns Mamrille. ,Johns Manville