HomeMy WebLinkAboutProject Information j INSTALLATION AN' � 1� '', �E OPERIXAMON MANUAL Pro�diMtAR 6 20 4 4.'[ODUC •I 1NG English { Frangais { Espan'ol St.Lucie County, FL � ILE COPY ,,, v I JandyO 'Pro Series JE Heat.Pump • I I R NEAR= ' I . I , _ 4 FOR YOUR SAFELY-This product must be installed by a licensed HVAC technician certified in heat pump repair and maintenance by the jurisdiction in which the product will be installed where such state or local requirements exists.The technician must possess and comply with all certifications and regulations regarding the purchasing, handling,transportation and reclamation of R410A refrigerant. In the event no such state or local requirement exists,the installer or maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly.Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal'injury, or death. Improper installation and/ or operation can create-an electrical hazard which can cause serious injury, property damage,or m death. improper installation and/or operation will void the warranty. a o , 1 � Z ODIC. ® Jandyo Pro Series JE Heat Pumps I Installation and Operation Manual _ Page 5 �. not needed at the heat pump;connections are made include the following: inside of the heat pump electrical compartment. I. Field assembly (if required). Conduit may be attached directly to the heat pump jacket. 2. Appropriate site location and clearances. 3. Sufficient air ventilation. NOTE Flex conduit is recommended for connecting the electrical supply wires to the heat pump so 4. Proper electrical wiring. that the front panel may be removed easily For 5. Adequate water flow. servicing. This manual provides the information needed to 4. Electric cutout switch that will interrupt all power meet these requirements.Revie,.v all application and to the unit.This switch must be within line of sight installation procedures completely before continuing the of the heat pump. installation. 5. Watertight conduit to nun the electrical supply line. Recommended: Zodiac recommends installing 2.2 Location Requirements isolation valves on the inlet an&outlet water NOTE Indoor installations require special connections for ease of serviceability. considerations for condensate drainage and, venting the cold air produced by the heat 1.7 Specifications pump.Contact the Zodiac technical support Suitable for indoor and outdoor use.Clearances shown department at(800)822-7933. in Table 2 must be adhered to. CAUTION Water Pipe/Heater connection ® Plastic 2"PVC(Unions included) When pool equipment is located below the pool' Flow Rate surface, a leak from any component can cause Maximum 70 gpm(265 ipm) large scale water loss or flooding.Zodiac cannot r Optimum 60 gpm(2301pm) be responsible for such water loss or flooding or Minimum 20 gpm(76 Ipm) resulting damage. Maximum Working Water Avoid placing the heat pump in locations where it can Pressure 75 psi cause damage by water or condensate leakage.If this is Electrical Supply not possible,provide a suitable drain pan to catch and Voltage Requirements divert any leakage. 1-Phase 230 VAC 60Hz All criteria given in the following sections reflect 3-Phase 230 VAC 60Hz minimum clearances.However,each installation must (Made!dependent) also be evaluated,taking into account the prevailing local conditions such as proximity and height ofwalls, Maximum Working Refrigerant and proximity to public access areas. I Pressure 600 PSI Clearances The heat pump must be placed to provide clearances on Dimensions all sides for maintenance and inspection.See Table 2. See Figure 1 for heat pump's dimensions and for Access in front of the heat pump of 24"(60 cm) dimensions to critical connections. provides adequate room for serviceability. If the heat pump is to be installed in a garage or under' Technical Specifications a vertical overhang,the unit must have a minimum of See Table 1 for the Tandy Pro Series 3E heat pump 5 feet(1.5 meters)clearance from the top of the heat technical specifications. PUMP- In the U.S.,the heat pump must be installed at least 5 feet Section 2, Installation Instructions (1.5 meters)from the inside wall ofthe pool or spa unlessthe 2.1 General Information Install the Zodiacs heat pumps in accordance with the procedures in this manual,local codes and.ordinances, and in accordance with the latest edition of the LE COPY appropriate national code.(See Section 1.4,"Codes and Standards".)Correct installation is required to assure safe operation.The requirements for Zodiac heat pumps Table 1. Jandy Pro Series JE Heat Pump Technical Specifications F�Jggfj� VOLTAGE 230VIGOHZ 230V/60HZ 23OV180HZ 230V/BDHZ0 230V/BOHZ 230V16OHZ13 OUTPUP 72,000 BTUs; 103,000 BTUs 113,0130 STUs 137,000 BTUs C" INPUT, 3.03 kW 5.03 kW 5.34 kW 8.37 kW COP* 5.6 6 6.2 6.3 OUTPUT,STANDARD RATING CONDITIONS- 67,000 BTU5 92,000 BTUs 106,000 BTUs 127.000 STUB COP,STANDARD RATING CONDITIONS" 5.2 5.7 5.5 6.0 5.9 6.0 6.9 OUTPUT,LOW AMBIENT" 46.000 BTUs 54,000 BTUs 74,000 BTUs 85,000 BTUs 86,000 BTUs COP,LOWAMBI6Nr- .4.0 4.0 4.0 4.2 1 4.0 4.2 1 ---- -A-P.---". --- --- -. RLA(RUNNING LOAD AMPS) 19.87A 30.77A 32.05A .23.21A 32.05A 25.00A LRA(LOOKED ROTOR AMPS) 106A 178A 148A 164A IBSA 164A MINIMUM CIRCUrrAMPACrrY 25.14A 40.21A 41.81A 30,76A 41.81A 33.OA MAX OVER CURRENT PROTECTION— .45A PDA BOA 45A GOA SDA HEAT EXCHANGER Tllanlum COMPRESSOR Reciprocating Scroll Scroll Scroll CABINET ASS REFRIGERANT 64 Oz,R410A TI Oz R410A 78 �410A 70 OA R410A 118 Oz,R410A126 Oz R41 OA 118 Oz,R410A 126 Oz,R4 IDA CL REFRIGERANT HIGH PRESSUREALARM SOD PSI(reset to 14BO PSI) REFRIGERANT LOW PRESSURE ALARM- 68 PSI(reset to 127 PSI) Cn HEATING UNITS REFRIGERANT LOW PRESSURE ALARM- 35 PSI(reset to 74 PSI) REVERSE UNITS C- M LOW WATER FLOW ALARM 20 GPM MAXIMUM HEIGHT BELOW WATER LEVEL 10 fast below pool level MINIMUM HEIGHT ABOVE WATER LEVEL 5 foot above pool level OPTIMAL WATER FLOW 30 GPM 42 GPM 48 GPM 45 GPM 57 GPM 57 GPM v. MINIMUM WATER FLOW 20 GPM MAXIMUM WATER FLOW 70GPM 2L AIR FLOW 2100 CFM 3600 CFM EL WATER TEMPERATURE DIFFERENTIAL(DELTA Adjustable between I IF to SIF T) " UNION SIZE 2• rD WEIGHT 176 lbs 220 lbs 223 lbs 223 lbs 228 lbs 230 lb. 228 lb, 230 it). @ ti C. • FILE COPY Test Conditions:80'FAIT,00%RH,80'F Wal04 Outside the scope orAHRIStandard 1160(I-P) Rated In accordance wlihAHRI Standard 1160(I-P) Max Over Current Protection refers to the maximum breaker size allowed.If this value is not a standard breaker size,use the next smallest standard size breaker. The breaker olze must not be smaller than the Minimum Circuit Ampoolty Value. Jartal-V o�ienes_11:H I eat Pumps 1, l9st-allation and 01,erafion Jana, 1 A��� Page 71, Figure 1. Jandy Pro Series JE Heat Pumps Dimensions MODEL SIZE DIMENSIONS - -- A 8 C D E F JE1500T 33" 34" 12.5' 9" 7" 39' JE200012500T 36" 40" 13.8' 19.1 15" 43' JE3000T 1 36" 44" 13.8" 19.. 15" 43" �CC E E-3 T_ C S.--A I heat pump is separated from the pool or spa by a 5 foot(1.5 Table 2. Heat Pump Clearances meters)high solid fence or otberpermanentbarrier. In Canadian installations,the minimum distance to be Side of Minimum Clearances for Recommended Clearances maintained from the inside wall of the pool or spa is 3 Heat Operation forSericeability meters (approx.10 feet). pump Inches Centimeters Inches Centimeters Front 24 60 36 so Equipment Pad Rear 12 30 24 60 Place the heat pump.on a flat slightly pitched surface, Left 12 30 24 60 such as a concrete or fabricated slab(pad).This allows Right =1 2 30 24 60 proper drainage of condensation and rain water from the TOP 60 150 60 150 base of the unit-If possible,the pad should be placed at the same level or slightly higher than the filter system NOTE:Clearances listed in Table 2 are manulaclurerslasled values. These are given as minimum values.Mere local and national codes equipment pad. apply,and values are different than those listed in Tablet,use the NOTE Ensure that the pad is pitched not more than Y4 greatervalue to ensure safe and proper operation. inch per foot cm per toward the compressor end ifneeded. (front)of the heat pump.Pitch slab from back to Roof Run-off front%inch per foot maximum and level from side to side. Make sure the heat pump is not located where large amounts of water may run-off from a roof into the unit Condensation and Drainage Sharp sloping roofs without gutters will allow massive' c' Condensation will occur from the evaporator coil while amounts of rain water,nixed with debris from the roof the-unit is running and drain at a steady rate,usually to be forced through the unit.A gutter or down spout 3 to 5 gallons(11.4 to 18.9 liters)per hour,depending may be needed to protect the beat pump. upon ambient air temperature and humidity.The more Installation of Anchor Clamps humid the ambient conditions,the more condensation In Florida,building codes require that the heat pump be -will be produced.Keep the drain holes of the base of the anchored to the equipment pad or platform to withstand unit clear of debris. high-wind pressures created during hurricanes.Other If the heat pump is installed indoors*,means of jurisdictions may have similar requirements.Pleas condensate disposal must be provided check your local codes for further details. Indoor installation requires factory consultation This heat pump is provided with anchor clamps designed to hold the unit to the equipment pad in high Lawn Sprinklers wind conditions.Installation of the anchor clamps is Keep lawn sprinkler heads from spraying on the heat recommended in all installations and are required in pump to prevent corrosion and damage.Use a deflector Florida(reference Florida Building Code,Mechanical Section 301.13).