Loading...
HomeMy WebLinkAboutBuilding plansi Planning & Development Services Department DO`L. �< 7 Building & Code Regulations Division , j �� �? �f _' ' 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 Certification for Design Load Compliance Project Name: LACKEY RESIDENCE Project Address: 2790 GENTILE RD. Permit#: Occupancy Type: R Construction Type: V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that aooly) 1. DESIGN CODE: Florida Building Code 2014 Edition with 20 _Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed —Partially Enclosed Open 3. Risk Category: _I X11_III IV Exposure Category: _B X C_D 4. Design Wind Velocity 160 mph 124 ASO N/A LRFD End Zone Width: 5 it S. Mean Roof Height: 13.7 ft Roof Pitch: 7 ;12 Parapet: N/A it 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): 19.3 19.3 19.3 33.6 33.6 31.8 Zone 1: _30.7 Zone 2: _53.5 Zone 3: 79.1 Zone 4: -36.4 Zone 5: _44.9 Garage: -41.5 7. Design Loads: Floor: 40 PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Paul Welch P.E. 29945 / 5115 Print Name Cert # & Co. Cert Auth. Paul Welch Inc. ON PLAN 1/25/2017 Signature, Date, and Seal 1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL Company Name &Address SLCCDV Form # 020-12 Revised 3/15/12 (IS) WINDOW/DOOR SCHEDULE 1 -- SH25 WINDOW (37'/" W X 63" H) 2 ----- (37" W X 37" H) S.H. WINDOW 3 ----- 3 0 6 8 S.C. DOOR WITH SIDE LITE �IV 4 -- 3 0 6 8 SOLID CORE DOOR 5 ----- 16 0 7 0 OVERHEAD DOOR A ----- 3 0 6 8 INTERIOR DOOR B 2 8 6 8 INTERIOR DOOR C ----- 6 0 6 8 BI-FOLD DOORS D - 5 0 6 8 BI-FOLD DOORS E 2 0 6 8 BI-FOLD DOORS F -- - 6 0 6 8 CASED OPENING G ----- 3 0 6 8 CASED OPENING TABULATION LIVING 1,696 S.F. PORCHES 494 S.F. GARAGE/STORAGE 648 S.F. TOTAL 2,838 S.F. Building Permit 4 Planning & Development Services Department Building & Regulations Division Product Review Affidavit OwnersNa se /A61LeV Produot. Opening Design prosaines Product Reted Design pleasure,b Manufacturer Model Nornbar Product Approval Via, Method of Attaahmenl windows SEg ELtrs -t. 0, b i'(, T 5 u ' too uoad -o5e5,o2 PA4T .; � P'F C., E' k Mullions - Food Glass - f Black Glass t skylights Sliding Glass Doors AwIno Type Doers re TELitJ`S + -`'i3O TurQM1^Tro Smaojo JrAIL FLd 5831,Q NIA.{„'�j� Sr� 1 ( ID ice• rwfwn Doors w/ (. *1 _ 4p TUFefAA�Teu Sr-•duTN STAP %G �.�SZZ �,15 - 7pap \ _ 11 It 4 ear eDoors 'r 4o �. q.q, D4 pj E4, II PAh16•03 0.01 NIA _ sllb" x.159%at. $er#vS Ar f,Z•,P, e', Hurricane Protection 0.0$' ALokA FLW 05(p4d NIA 319" S•6�7 Sb-T W )°EM -4 Jo ttAU. Al 12"s, (, RoorVenillaeon 'MIA Roofing Mabdal 1 • . u), i Z. •f9,5 35F 74,1.-tB9,2S t 1 = - 78, IS" 2.2 • - 7$,5 sou4as? ry �� if 19b2!-1 �/A $&E Rporlly& 4 r7A.GldreleNY. ®a puINS I have reviewed the above componentst6r cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current. code Provisions. - Name: PAD' WELCH p•E, Signature: ON PLAN Design Profa I PAUL WELCH P.E. Cert, No. 29949 Date; - 11 8N I —I 2 I I O �.� Ia ZIV— %'— ter-" f�J \hIICr Debd'iN r�ds"fE.Z EM • Q E � Q U1J >p a NOTES: I THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT, 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. 3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4) ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE (FBC) 2014, FBC 2014 RESIDENTIAL, FBC 2014 PLUMBING CODE, FBC 2014 MECHANICAL CODE, FBC 2014 ENERGY CONSERVATION, AND THE NEC (NFPA 70) 2011 EDITION. 5) RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVY TERMITE INFESTATION AREA PER FRC 301. _ T ,TNTF.T . ,Cri4ml Tr -P l7 3- 43y/ ST. LUCIE COUN BULDING D1YIeI0\ REVIEWED FOR L \CE REVIEWED Y DATEew Z a PLANS AND P R\1IT MUST BE KEPT 0* 0B OR NO INSPECTI N WILL BE :BADE, iHEBE PLANK A44 A4 P QPQSE7 WOFIr ARE RUBJIQTTip A FPI 1 GTIgNS REOUIRRD BY Irl€LA IySHEC' d9 THAT MAYBRNROl9d/4# I�, T6 _- COMPttffeylA(h!Rri�. Ecooes. SAFE APPLIED SAFE APPLIED LINTEL L-1 L-2 L-3 L-4 LENGTH/TYPE 17'-4" 208" PRESTRESSED 4'-6" 54" U-LINTELS 5'-10" 70"RECESSED 4'.4" 52" RECESSED GRAVITY LOAD 1326 6133 4242 5206 GRAVITY LOAD 250 820 680 680 UPLIFT LOAD 520 2724 1900 2635 UPLIFT LOAD 150 500 500 500 COMPOSITE BEAM 81720 iB-IT 8F161B-1T 8R 14 LB -IT RF14 1B-IT r� (L Or 0AWLl MA �TE1w 0 ;?A"P�"Eb?�L. 0L2,LINP�( I �i i e;40i,IWTe,e- 9 ly Aualwt � � I 3A(Z'fo P U � �hbL•i+ I1� IA W ti - � i 4 I f TioA 1� , I -.---- ...---..-•-.• .�u..�....�w..wauvrv�, N,UKJl CANLLOADINGIS SHOWN NOTE: PROVIDE "CASTCRETE" PRE -CAST CONCRE.E LINTEL AS NOTED ON PLANS. -T! c1 } -4 Poh'r cr„T•.) �1avL•�2'"+� r �, <,�p i 1 COO, OO 101, J n 6A,r � Poe" 1 4 L- 1Q O qQ Q t fP,i4 I y'_ n,. Ec-ors 5s !� k�araM Q hN /i� I 4,0 1 =Q r-_-I NLl• ( Gib �g -i N I 00 _ I I �. 14"t.anl-cBfC. ' I f . L L•.t _ 'd' 54 Z, x _ tJ cpeir,iE i A-r-rlc p Ppr,IT�( f f Y aiz :u t» L >A+ LL I i Q/1.12 Ca E aicF N gTc GALA _Q a; r a<ce C f TP 5 I i Q 5'- 0" 4 y'. q' 9 u r 6P,42 cwle (((' L+&+5 ,� / o . 1 I F / DFpoNi o MA 1W Ii Cs 2c5s - L!LarS'sWOEP 511tt't1ttK t� � D�1t:S'S e1 1 Ll Q L-tl p t-Z N •• r pole pNL� 11' 4„ 3 O '- " PAN A,EA rl.T. Pp,.i bsi. 2'le tz,. 4'% R," 1LED FASTENERS ORATTAC. E THE RESPONSIBILITY OFT}ic CONTRACTOR OF RECORD `I& ad cn 0 Z 4O 0 r z x F7 in Z LL. L O O G7 > ( PAUL WELCH INC MECHANICAL ELECTRICAL CIVIL ENGINEERING 1984S.W.. 9ILTMORES7: SUITE# / /4 PORT ST. LUCX FL 3498,j - P"0AE'(772)785-9888 EMAIL PWE'LCH/1VC@AOL.COA1 PA(:/L VM5LCF/, P. E. FL A REG NO.29945 APR 1 12N7 Feel �I o i ice+ 0 h � h � o �r� Lj 1 /Tr4 I V N GARAGES FLOOR SURFACE 1) GARAGE FLOOR SURFACES SHALL BE OFAPPROPED NONCOMBUSTIBLE MATERIAL. 2) THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY DOORWAY. PLUMBING NOTES: 1) ALL WORK SHALL BE IN ACCORDANCE WITH THE FBC 2014-PLUMBING 2) DWV PIPING SHALL BE SCHEDULE 40 PVC. 3) WATER PIPING IN BUILDING SHALL BE ONE OF THE FOLLOWING: TYPE L COPPER, CPVC, OR PEX. 4) SLEEVE ALL PIPING IN CONTACT WITH CONCRETE OR UNDERGROUND WITHIN BLDG. 5) HOT WATER PIPING WITH A MINIMUM THERMAL RESISTANCE OF R-3 SHALL BE APPLIED TO PIPING LARGER THAN'/." NOMINAL DIAMETER, PIPING FROM WATER HEATER TO KITCHEN OUTLETS, PIPING LOCATED OUTSIDE THE CONDITIONED SPACE, PIPING FROM THE WATER HEATER TO THE DISTRIBUTION MANIFOLD, PIPING LOCATED UNDER THE FLOOR SLAB, BURRIED PIPING, SUPPLY AND RETUN PIPING IN RECIRCULATION SYSTEMS, PIPING WITH RUN LENGTHS GREATER THAN 20 FEET. 6) WATER HEATERS INSTALLED SHALL BE IN ACCORDANCE WITH FBC 2014 ENERGY CONSERVATION. FOUNDATION SCHEDULE F-I 16" D X 16" W (2500 PSI) CONCRETE MONOLITHIC FOOTING W/ (2) #5 BARS CONTINUOUS F-2 12" D X 12" W (2500 PSI) CONCRETE MONOLITHIC FOOTING W/ (2) #5 BARS CONTINUOUS (STEP FTG) NON -BEARING FOOTING WITH STEP S-1 4" THK (2500 PSI) CONCRETE SLAB W/ FIBERMESH OR 6"/ 6" 10/10 W WM OVER VAPOR BARRIER ON CLEAN COMPACTED CHEMICALLY TREATED FILL S-2 4" THK (2500 PSI) CONCRETE SLAB W/ FIBERMESH OR 6"/ 6" 10/10 W WM OVER VAPOR BARRIER ON CLEAN COMPACTED FILL (NOT TOUCHING RESIDENCE FOUNDATION) i t Z'- 4" N D., Zf3'- 4 __..___.____.._____..___.._F Z' I , 0 r ml N - PAUL WELCH INC - - MECHANICAL ELECTRICAL CIVIL EfdGANEER/NG 198,4S.W. BIL7 NOREST. SUFrE& ./ 14 PORT ST. LUCIE, FL 34984. PHONE (7721785.9888 EMAIL PWELCf-//NCCpAOL.Com PAUL WELCH, P.E. FLA REG NO.29945 FE 14401 MARK I E ZONE 4 ZONE 5 Area ft2 + - + - 1 10 33.6 -36.4 33.6 -44.9 2 15 33.5 -36.3 33.5 -44.8 3 20 33.4 -36.2 33.4 -44.6 4 25 33.3 -36.1 33.3 -44.4 5 30 33.2 -36.1 33.2 -44.2 6 35 33.1 -36.0 33.1 -44.1 7 40 33.0 -35.9 33.0 -43.9 8 45 32.9 -35.8 32.9 -43.7 9 50 32.9 -35.7 32.9 -43.5 10 110 31.8 -34.7 31.8 -41.5 -NaV-PIE PGA rr-,P�,J'r O N Lmi !-rrr ) Z ® Q R3 ?,p mP PgAJ.A •p a Y+�I �F SHEET NUMBER ALUM. DRIP EDGE 2X P.T. WOOD FASCIA q� SOFFIT 2 X 4 "X" BRACING AT RIDGE AND 6 FEET O.C. EACH SIDE OF MIDGE 2X4 LADDER FRAMING AT 12 INCHES O.C. 2 X �PRUCE OR BETTE I — GABLE END TRUSS LATERAL BRACE AT 6 FEET O.C. FASTENED TO 1OP OF BOTTOM STUCCO / WIRELATH /VAPOR BARRIER /SHEATHING PER CHORD OF TRUSSES WITH (2) - 16d — NAILS EACH, AT GABLE END STRUCTURAL NOTE # WSJ AND 4 TRUSSES BACK, - 16 D COMMON NAILS AT 12" O.C. STRAP GABLE END TRUSS WITH "S"SON' HETA20 AT 48" O.C. CEILING PER PLAN " E1�D STRAP EJ BE 4" P.T. 2 X 8 CONTINUOUS WITH "Y BOLT OR %a" X 5'h" WEDGE ANCHOR AT 24" O.C. WITH 2" X 2" X 1/8" WASHERS NOTE: PROVIDE RAKE BEAM AT REINFORCE EACH VERTICAL VAULTED GABLE MEMBER OF GABLE END TRUSS WITH 2 X 4 T- BRACE WITH 16 D NAILS AT 8 INCHES O.C. PLAN VIEW T-BRACE i. t tivrrt�p PANEL FASTENER: #10 X 1 %z" WOOD-ZAC XG FASTENER, HEX -HEAD W/ NEOPRENE WASHER WOODSCREW IN THE RIB OF THE PANEL, 3/16" MINIMUM PENETRATION THROUGH THE PLYWOOD. ALL FASTENERS TO BE CORROSION RESISTANT. FASTENERS SHALL BE INSTALLED WITH SCREWS SPACED PER BELOW: ZONE i & 2: SCREW SPACING 16" O.C. ZONE 3: SCREW SPACING 8" O.C. ROOFING ATTACHMENT nts.., PER FL# 19621.1 "KEY WEST SERIES" 5-V CRIMP ZONE 1 & 2 DP: -7&5 PSF /// ZONE 3 DP:-189.25 PST METAL ROOF PANELS SHALL BE SECURED TO THE SUPPORTS IN ACCORDANCE WITH THE APPROVED MANUFACTURER'S FASTENERS. METAL PANELS SHALL BE ATTACHED PER MANUFACTURER'S SPECIFICATIONS AND DETAIL THIS SHEET. UNDERLAYMENT: UNDERLAYMENT SHALL BE TRI-BUILT ROOFING PRODUCTS FL# 160481 "TRI-BUILT S/A HT TU". WHILE PRIMING IS OPTIONAL, TRI-BUILT RECOMMENDS PRIMING THE DECK IF THE FINAL ROOF COVER IS NOT SLATED FOR INSTALLATION WITHIN 24 HOURS. GABLE �TT� DETAIL T ♦ TT APPLY SHEET PARALLEL TO THE ROOF EDGE. ROLL OUT APPROXIMATELY 10 FT OF MEMBRANE GAaBLE END LE 1 f'� 1L nts...i AND PEEL BACK THE FIRST 3 FT OF RELEASE FILM, ADHERE THE EXPOSED PART TO THE SUBSTRATE AND UNROLL THE REMAINING MEMBRANE AS FAR AS POSSIBLE. ONCE THE ENTIRE LENGTH OF MEMBRANE IS IN PLACE, PEEL -OFF THE RELEASE FILM DIAGONALLY WHILE HOLDING THE MEMBRANE TIGHT. FIRMLY ROLL THE 22'A' 19, MEMBRANE INTO PLACE TO ACHIEVE A BOND. HORIZONTAL SEAMS SHOULD BE MINIMUM 3- 28'-4 —_- INCHES, CONFIGURED TO SHED WATER. VERTICAL SEAMS SHOULD BE 61NCHES AND STAGGERED - I I I I NOT LESS THAN 2-FT FROM VERTICAL SEAMS IN THE COURSE BELOW. ALL OVER -GRANULE END - LAPS SHALL BE SEALED USING EITHER HEAT -WELDING OR HOT AIR WELDING TECHNIQUES. FOR I I VALLEYS AND RIDGES: CUT UNDERLAYMENT INTO 4 TO 6 FOOT LENGTHS. PEEL THE RELEASE < ¢ < < a < < < < I i PAPER AND CENTER SHEET OVER VALLEY OR RIDGE. DRAPE AND PRESS SHEET INTO PLACE, --'--------------------_-----L--___—__—_—_—__—_----_—_---1--_ WORKING FROM THE CENTER OF THE VALLEY ORRIDGE IN EACH DIRECTION. FOR VALLEYS, u� 1 APPLY THE SHEET STARTING AT THE LOWEST POINT AND WORK UPWARD. " N I FLASHING SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE ENTERING v THE WALL AND ROOF THROUGH JOINTS IN COPINGS, THROUGH MOISTURE -PERMEABLE MATERIALS AND AT INTERSECTIONS WITH PARAPET WALLS AND OTHER PENETRATIONS 0 o m m m m m m m m m m m m m m m m m m m m THROUGH THE ROOF PLANE. ALL FLASHING SHALL. BE IN ACCORDANCE WITH FLORIDA _ — — BUILDING CODE m FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, AT GUTTERS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR DIRECTION AND AROUND ROOF OPENINGS. WHERE FLASHING IS OF METAL, THE METAL SHALL BE CORROSION RESISTANT WITH A THICKNESS NOT `o LESS THAN PROVIDED IN FBC TABLE 1503.2. THIS REQUIREMENT DOES NOT APPLY TO HIP AND RIDGE JUNCTIONS. ALL ROOFING INSTALLATIONS SHALL BE IN ACCORANNCE WITH FL41962LIAND FBC 2014. 1 4 3/ 1" 26.5" m m m m m m m mn. a a ja<CD a a a a a c� M Ww "A" 9 hw EAVE s N 20 py C Q ` Q RIDGE 14 io d \ �,, 0 ® 3 io BAVE s O ROOF SHEATHING NAILING TONE nts... "A" = 5 FEET ^� (lYPICdf. GF.NARlCItADF, PLAiI"PLANY[SW') I I I ZONE ROOF SHEATHING ATTACHMENT REQUIREMENTS �I�I NAILS AT 6"O.C. PERIMETER AND 6" O.C. FIELD N to NAILS AT 6" O.C. PERIMETER AND 6" O.C. FIELD - I I ® NAILS AT 4" O.C. PERIMETER AND 6" O.C. FIELD — --------------- — ———————————— —————-----�--- — i I I — — NOTE: ROOF SHEATHING SHALL BE 19/32" THICK CDX PLYWOOD ROOF SHEATHING FASTENED TO ROOF FRAMING WITH 8d RING -SHANK NAILS (PER FRC803.2.3.1) SPACED I I I PER ZONE DESIGNATIONS AS SHONW ABOVE. X 23'-4" I 3,-8„ I B,A. 6, SHEET NUMBER PAUL WELCHINC pF MECHANICAL ELECMIGAL CIVIL EAfGIEgR/NG 41. 1984 S. W. B/LTMOREST, SU/TE# 114 PORTST. LUC/E, FL 54984 _ f'H0NE(772)785"9868 E/[?A/L PMELGHINCOAOL.COM PAUL WELCH, ,P.E. FLA REGNO. 299.45 FEB 14 2017 TRUSS CONNECTOR SCHEDULE TRUSS ID BEARING POINT TRUSS ACTUAL CONNECTOR CONNECTOR FASTENERS NOTES UPLIFT ID UPLIFT DESIGN GEA & GEB CONT. 200 PLF ( ) HETA 20 1810 (9)-10d X 1 1/2" 01 j 1 STRAP AT EACH END AND AT 48" O.C. ALL OTHERS AT CBS BEARING LESS THAN 1800# EACH < 1800# (1)- HETA 20 1810 (9)-10d X 1 1/2" AT CBS BEARING ALL OTHERS AT FRAME BEARING LESS THAN 1000# EACH < 1000# (1)- MTS 16 1000 (14)-10d X 1 1/2" AT FRAME BEARING TRUSS COMPANY CHAMBERS LAYOUT DATE 1 31 2017 CUT -SHEET DATE 2 1 2017 CHAMBERS JOB# 74085 NOTE: ALL STRAPPING TO BE SIMPSON STRONG -TIE AS SPECIFIED. NOTES: 1 AT FRAME BEARING BEAMS USE "SIMPSON" LSTA15 WITH (12)-10d NAILS AT 48" O.C. IN LIEU OF HETA20. TRUSS NOTES: 1) ALL ROOF TRUSSES TO BE DESIGNED BY TRUSS COMPANY'S ENGINEER. 2) CONTRACTOR TO PROVIDE PAUL WELCH INC., AND BUILDING DEPARTMENT WITH ENGINEERED TRUSS DRAWINGS BEFORE INSTALLING TRUSSES. 3) CONTRACTOR TO VERIFY ALL ROOF CONDITIONS, AND DIMENSIONS BEFORE ORDERING, AND INSTALLING TRUSSES. 4) TRUSS TO TRUSS CONNECTIONS TO BE PROVIDED BY TRUSS COMPANY. 5) SEE TRUSS CONNECTOR SCH. FOR TRUSS TO WALL CONNECTIONS. FASCIA PER TYPICAL WALL SECTION STUCCO OVER WIRELATH W/ 1IGA. 2" NAILS W/ 3/8" 0 HEAD @ 6" O.C. OVER 3/8" METAL RIB LATH @ 6" O.C. W/ (2 LAYERSOF 15# FELT OVER EACH FRAMING MEMBER) 6" X 18" SCREEN VENTS AT 48" O.C. OR 4" CONTINUOUS SCREEN VENT WALL SOFFIT DETAIL nts... STRUCTURAL NOTES 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. 2) SOIL BEARING CAPACITY: 2500 PST (MIN.). 3) ALL STRUCTURAL CONCRETE IN BEAMS, LINTELS, VERTICLE CELLS, AND COLUMNS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. 4) SLAB /FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS. 5) MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3" BEAMS: I %" SUSPENDED SLABS: 1 Ys" 6) LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETER$ EXCEPT AS NOTED GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS. 7) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 8) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALATION OF HARDWARE IS NOT PERMITED. 9) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICIES. 10) LNLU 3 OTHERWISE NOTED FOR EXTERIOR WALLS, EXTERIOR PLYWOOD SHEATHING AND INTERIOR DRYWALL IS TO BE NAILED WITH IOd OR BETTER NAILS 6" O.C. EDGES, AND 6" O.C. FIELD, OR SCREWED WITH DRYWALL SCREWS 1.5" LONG AND 0.131 DIA. 11) LINTELS SHALL HAVE A MINIMUM 4" BEARING. 12) PROVIDE # 5 CORNER BARS W/ 30" MIN. LAP SPLICE FOR BOND BEAM, 13) STUCCO CEILINGS: EXTERIOR CEILINGSTO BE STUCCO OVER WIRELATH W/ 11GA. 2" NAILS W/ 3/8" 0 HEAD @ 6" O.C. OVER 318" METAL RIB LATH @ 6" O.C. W/ (2 LAYERSOF 15# FELT OVER EACH FRAMING MEMBER). 14) EXTERIOR FRAME WALLS TO BE STUCCO OVER WIRELATH WITH 11 GA. 2" LONG NAILS WITH 3/8" 0 HEAD @ 6" O.C. OVER (2) LAYERS OF (15# FELT OR TYVAK BUILDING WRAP) OVER 15/32" CDX PLYWOOD WITH IOD NAILS TO STUDS @ 6" O.C. PERIMETER AND FIELD. 15) WEEP SCREEDS. A MINIMUM 0.019-INCH (0.48 MM) (NO.26 GALVANIZED SHEET GAGE), CORROSION -RESISTANT WEEP SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF Y/2 INCHES (89 MM) SHALL BE PROVIDED AT OR BELOW THE FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH ASTM C 926. THE WEEP SCREED SHALL BE PLACED A MINIMUM OF 4 INCHES (102 MM) ABOVE THE EARTH OR 2 INCHES (51 MM) ABOVE PAVED AREAS AND BE OF A TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING. THE WATER -RESISTIVE BARRIER SHALL LAP THE ATTACHMENT FLANGE. THE EXTERIOR LATH SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SCREED. HARDIE SIDING NOTES: HARDIEPLANK AT CMU WALL: HARDIPLANK SIDING AT CBS TO BE ATTACHED OVER TYVAK BUILDING WRAP OR 15# FELT OVER 2"X2" FURRING @ 16"O.C. HARDIPLANK TO BE APPLIED HORIZONTALLY WITH 1 'A" LAPS AT TOP OF PLANK. HARDIPLANK TO BE ATTACHED WITH 8D X 2 ''/z" LONG GALVANIZED BOX NAILS PLACED IN THE OVER -LAPPED AREA AT 8" ON CENTER VERTICALLY AND 16" ON CENTER HORIZONTALLY INTO FURRING. FURRING TO BE ATTACHED TO CBS WALL W/'/4" TAPCONS X 1 ''/a" EMBEDMENT AT 16" O.C. VERT. OR HARDIPLANK DIRECT TO CMU HARDIPLANK SIDING TO BE ATTACHED OVER TYVAK BUILDING WRAP OR 15# FELT OVER EXISTING BRICK. HARDIPLANK TO BE APPLIED HORIZONTALLY WITH I VV LAPS AT TOP OF PLANK. HARDIPLANK TO BE ATTACHED WITH ET&F FASTENING SYSTEM INC ET&F BLOCK NAIL (ET&F NO. ASM-144-125, HEAD DLA 0 30', SHANK DIA.-0/14", LENGTH = 1.25" LONG) , OR MAX SYSTEM BLOCK NAIL (CP-C832 W7-ICC, HEAD DIA. = 0.30", SHANK DIA. = 0.15", LENGTH = 1.3".) OR AEROSMITH BLOCK NAIL (5323HP, HEAD DIA. = 0.30", SHANK DIA = 0.1444", LENGTH=1.25") PLACED IN THE OVER -LAPPED AREA AT 8" ON CENTER VERTICALLY AND 12" ON CENTER HORIZONTALLY INTO BLOCK. BOTTOM CORD OF TRUSS %" DRYWALL BOTH ---- '/2" DRYWALL (WALLS SIDES (SEE ADDITIONAL AND CLG) NOTES FOR WALLS ADJACENT TO SHOWER AND TUB) 2 X 4 WD. TOP PLATE OR 1 '/" X 3 5/8" METAL RUNNER 2X4 P.T. WD BOTT. PLATE OR 1 %" X 3 5/8" METAL RUNNER W/ TAPCONS 2 X 4WD STUDS @ 240 @ 24" O.C. -- O.C. OR 1 %" X 3 5/8" METAL STUDS @ Z4eO.C. CONC. FLOOR TYPICAL INTERIOR NON-BRG. n`„• WALL DETAIL Y" DRYWALL (CEILING) ' (1 ROW) 8"X8" CONTINUOUS CONCRETE BEAM BLOCKW/ (1) - #5 BAR IN (3000 PSI) CONC. FILLED EACH CELL 8" PRECAS LINTEL W/ (.I)-#5 BAR IN (3000 PSI) CONCRETE FILLED CELL AT ALL DOOR AND WINDOW OPENINGS (SEE LINTEL SCH. FOR MORE INFORMATION) ROUGH BLOCK - -- _77 vael�� WF rhl SEE TYPICAL WALL SECTION FOR ADDITIONAL INFORMATION PRE-ENGINEERED ROOF TRUSSES @ 24" O.C. MAX SIMPSON STRAP PER TRUSS CONNECTOR SCH. STUCCO CEILING: ALUM. DRIP EDGE STUCCO OVER WIRELATH W/ I IGA. 2" '_' IX6 P.T. WD. FASCIA NAILS W/ 3/8" 0 HEAD @ 6" O.C. OVER 3/8" 2X4 WD. SUB -FASCIA METAL RIB LATH @ 6 O.C. W/ (2 LAYERSOF SOFFIT PER DETAIL 15# FELT OVER EACH FRAMING MEMBER). DOUBLE 2X12 WOOD HEADER WITH %" CDX PLYWOOD SPACER GLUED AND NAILED W/ 16d NAILS SIMPSON AC4 W/ (28)_16d AT 8" O.C. STAGGERED NAILS EACH POST TO BOTH SIDES HEADER (USE SIMPSON LCE4 @ CORNER POSTS WITH (24)-16d NAILS) P.T. 4X4 WOOD POST SIMPSON LSTA 18 W/ (14)- SIMPSON ABU44 WITH (12)- I Od NAILS AT CORNER 16d AND (1)- 5/8"m X 12" POSTS (1) PER HEADER ANCHOR BOLT /�—FINISHED GRADE fits _ — (2500 PSI) CONC. 'zy V ; �• �• ke FOUNDATION (PER SCH) rlfl3glz1111�1(t TYPICAL 4X4 POST DETAIL . nts... '. METAL ROOFING / UNDERLAYMENT PER ROOF ASSEMBLY NOTES ON METAL ROOFING / UNDERLAYMENT -----•-- 19/32" CDX PLYWOOD ROOF PER ROOF ASSEMBLY NOTES ON SHEATHING WITH 8D RING -SHANK 19/32" CDX PLYWOOD ROOF NAILS PER DETAIL SHEATHING WITH 8D RING -SHANK - - / NAILS PER DETAIL PRE- ENGINEERED WOOD TRUSSES / @ 24" O.C.(MAX SPACING) R ; . PRE- ENGINEERED WOOD TRUSSES fi .✓ @ 24" O.C. (MAX. SPACING) "SIMPSON" STRAP PER TRUSS CONNECTOR SCH. "SIMPSON" STRAP PERTRUSS h� p R-301NSULATTONN� CONNECTOR SCH. -- METAL FLASHING (DRIP EDGE) METAL FLASHING (DRIP EDGE) Y:" DRYWALL (CEILING) -� I X 6 CEDAR FASCIA OVER (I ROW) 8"X8" CONTINUOUS CONCRETE 1 X 6 CEDAR FASCIA OVER 2X4 WOOD SUB -FASCIA BEAM BLOCKW/ (1) - #5 BAR IN - 2X4 WOOD SUB -FASCIA T STUCCO SOFFIT PER (3000 PSI) CONC. FILLED EACH CELL SOFFIT DETAIL STUCCO SOFFIT PER 8" PRRECAS LINTEL W/ (1)-#5 BAR SOFFIT DETAIL — #5 REBAR W/ 90 DEGR IN (3000 PSI) CONCRETE FILLED CELL E HOOK ATALL DOOR AND WINDOW #5 REBAR W/ 90 DEGREE HOOK OPENINGS (SEE LINTEL SCH. FOR — ASO 1 CONCRETE BLOCK MORE INFORMATION) „(MASONRY) _...„......_,_,._^ 8"X8"X.16" CONCRETE. BLOCK #S VERT, REBAR IN (3 00 PSI) (MASONRY) `W' DRYWALL (WALL) -. :. m. _ � -,�_ #5 VER CONCRETE FILLED C L..L I I T. REBAR IN (3000 PSI) i2 Ei�IZINS*-�-3" QR 24" O.C. -•.--.____; CONCRETE FILLED CELL (SEE PLAN FUR :LOCATIONS) fil•4-CFI CoazC Klw,Lfl) �nnj=r A (SEE PLAN FOR LOCATIONS) ) STUCCO FINISH Pl. FOIL INSULA'F10N -- -- •� -�----,�• STUCCO FINISH #5 REBAR W/ 30" MIN. AP SPLICE 77#5 REBAR W✓ 30" MIN. LAP SPLICE _ q, (2500PSI) CONC.FOUNiDATIONI`i1efif�al0k 141 ;,1e :` (2500 PSI) CONC, FOUNDATION EE PLAN FOR SIZES AND 1 s /� 7. I� SPECIFICATIONS pqp� @ e 12 �' SEE PLAN FOR SIZES AND SPECIFICATIONS ":/-•rti/ - /Tl.�1+9=�dOr.ieg,::eti ,f� _- FINISHED GRADE PAUL. WELCHINC MECHANICAL ELECTRICAL CIVIL EJVGINEE 1984 S. W. BILTMORE ST. SUIT # 114 - PORTST. LUCIE, FL .3498 -� _ PHONE(772)785.9888 EMAIL PWEL IIIVCLaA ` PAUL WELCH, P.E. FLA RECNO 29945 OR 112017 WUMBER Annnor Group Anchor SGb3lrete Min. Edge Dielenee Mtn. Embedment A 114.4168S ODA.Fle2 W,13o CMU, (ASTM M) 1a4" 1414" D ola Steel SMS Screw, (GSI P.T. Sa3hem Pine (SG=.55) W16" 141IT Aluminum, Dom T5 min, wr 1/r. Steel Stud, Gr. 33 min. 31T 0,0346 CA 0A)* A35 Steel alm IfIV 1/4" 410 SS CleteFlek P.T. Sather Pine (SG = .55) 1" 13/S° Cgnaete (min. 3,25 ksg 1" 1° o"Dined CMO, ( 7 CID) 1-314' 1-114" O 114" Steel Ulm. P.T. 6adhem P31B G .55) 1" L378" Cancrele (min. 2:llkaf) t" 1-318' Ungroutetl CMU, (A6TM G811)1 2112' 1-014" .. ' . • .'.' - ,.! - 1 M F 3 THREADS BEYOND T METAL S BST TE _ _ _ _ the MAX. ON CENTER dimension are nol Exceeded. { / 'MMIMU D THE EYDN THE V RA Con Be arch table; e 3. Cancrefe anchor fG61A:ri .. •. '.' '. .... �R.�, - .. •' .. EAWW. �I/CdRJ. AA.101 H0V Pfill, . NnnN3rAV P.dIM AIIF, 13Ro11g—:FAu tRiee ReRalmd, Flange Fmme Me]nneD, vMn i. WMlh' 18413' 1 26-1'r 3Y 3" 41' 4Y ♦P .eevr M.s 93eh Hcl9hF A Group ll Cww Gmw A mq 0 Pcup c DuwA Group S Nlm c Gray A Gyw B Gyup Gieup A amup a Gaw Gmw A Grw 6 Grew GIewA 6yw B Grow r-+wp A GawB mw will wgnt Ilee Fip31 A. IM1i6 eMatl x 2 � tM 6 � F $@ 4 5 'e m I $@ 4 � 2 9 � $P 6 � ]% 0< 3 $Y i S 2y 6 g � $@ L £ ]}' 0( g. E $$ pp F S P$ d 3 � ¢ g ; $p$ d¢ � 3E 5 i yt 2 $SS Q S $Fa 6 }3j' IA '3Fzz i. Y yy�� 5 Z 3 $Y2, 4 3 $i@ 6 S y5y Q ��}p t0 S 3 S ¢¢ 3 '$�R 6 'a1 2Y 1WIr 1ESu21 Lib) 2 2 21 21 2 I 2tzl 2 1 2 3 2 2 3 1 2 2 2 2 2 2 2$ 2 2 2 2 2 2 2 2 3 2 2 2 2$ E 2 2 2 1 2 2 2 2 2 2 agar 1J41C 2 2' 1 4 2 2 2 2 2 S 2 2 9 4] 2 3 2 3 R] 2 1 2 3 2 3 2 3 2 4 2 3 2 3 2 4 2 3 2 3 2 4 P 3? 3 2 3}• 13&tY (Egwi Lpe) 3 2 R 2 2 Z 2 z 2 2 2 1 3 2 2 2 Y Y E 2 2 2 2 2 3 3 2 2 2 2 3 3 3 3 P 2 3 3 3 3.2 2 3 9 3 J 2 2 er, 1eSl18' 1 2 2 1 x 2 2 z 2 2 1 Y. S 9 2 9P 2 T 3 2 9 2 P 2 3 2 3 2 3 2 4 2! 2 3 2 4 2 3 2 5 2 4 1 3 2 3 l Mer l5-N3' 2 3 2 2 2 2 3 2 2 Y 2 4 3 2 J) A 1 3 2 3 4 3 2 4 33 3 3 24 2 9 3 3 2 4 2 J 2 3 2 1 R 3 2 3 1 9B3'B' 1S>/Y d4u 1FY1P' I P 2 2 S Y 2 3- 2 2 Z Z 3 2 2 2 2 2 3 3 3 2 2 3 9 R 3 Y 2 T 3 2 9 1 9 2 9 2 3 23 R 3 2 3 2 2 2 19-11C IEesd ule) 2 2( 2 2 2 2 2 3 2 2 3 2 2 2 1 2 2 2 9 9 2 2 Y II 8 9 R 2 S 2 3 3 9 3 1 2 J 3 3 3 2 2 3 3 3 3 2 2 oar iPL4' 2 2 2 2 2 T 2 3 2 1 Y 4 2 J T 3 2 2 3 2 3 2 9 2 4 2 J 2 9 2 4 2 3 2 3 2 4 2 3 2 3..2 4 2 3 2 3 ukr1PM1Y 2 2 2 2 2 2 3 2$ 2 2 2 4 2 3 2 A 2 9 2 3 2! 2 4 3 1 4 9 2 4 2 1 2 9 1 4 2 4 2 3 1 4 2 3 2 9 2 4Y t00'Ir tlw22tlY' 2 2 2 2 2 1 2 2 2 2 2 2 3 2 9 2 2 2 3 2 J 2] 2 4 3 3 2 3 2 3 3 3 2 8 2 3 2 3 2 3 2 3 2 3 2 3 T 22YtY IEaul2Rq 2 x 3 2 2 2 2 2 P E 3 2 3 3 212 1 2 3 3( 3 3 2 2 3 3 3 3 2 2 3 3$ 3 2 2 3 3 313 2 2 J 3 3 3 2 2 .II-WW 2 2 2 2 2 2 2 J 2 3 2 2 2 4 2 3 3 2 112 3 2 3 2 4 2 4 2 9 Y 4 2 4 2 9 2 4 P 4 2 3 2 4 2 3 2 3 un4a N-tro' 2 2 2 R 2 2 3 2 1 3 2 9 2 ♦ S 3 2 3 2 4 2' 4 2 3 2 4 2 d 2 3 2 4 2 4 2] 2 4 2 4 2 3 2 4 2 0 2 9 2 4T MIDI-ew 64MYs 2 2 2 S 2 1 3 2 2 2 2 2 3 2 3 2 1 2 4 9 J 3 3 2/ 3 3 2 3 Y 6 3 J 1 3 P 3 33 2 3 2 3 Y 3 2 J 2 N-SIRY' (Ewe, uto 2 2 2 2 2 2 2 2 2 2 2 E 3 3 J 2 2 3 3 3 3 2 2 3 3 3 3 2 2 93 3 3 2 2 3 3] 3 2 2 3 3] 3 2 2 P0124 P/16 2 2 2 3 2 2 2 3 2 3 2 3 2 4 2 3 2 3 2 4 2 4 2 3 2 4 2 4 P 3 2 4 2 4 2 3 2 4 2 4 2 3 2 4 2 4 2 3 wrier 20.13ne' ] 2 2 2 2. 2 5 2 3 2 3 2 4 2 4 2 3 2 4 1 0 2 3 2 0 2 4 2 3 2 4 2 4 2 3 2 4 2 4 2 3 2 4 2 1 2 3 E sbYB, W1118" IMu 256IIB'' 2 2 2 2 2 2 3 z 2 2 2 2 3 2 3 2 3 2 4 3 3 2 3 2 41 3 2 3 2 4 3 3 x 3 T 0 3 3 2 3 2 3] 3 2 3 4 2]318' (Ewa Itie) 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3$ 2 2 9 3 3 3 2 2 3 3 3 3 3 3 3 3 3 3 1 2 3 3 3 A Z S 3 3 3 3 1 2 err 25y3' 2 3 2 2 2 S 2 3 Y> S J 2 4? 1 2 J 3 9 2 1 2] 2 A 2 4 J 2 1 2 1 T 4 wrier &d31t8` 3 1 3 9 8 34 9 3 9 9 3 1 9 4 3 J 3.4 3 4! 4 9 A l] J $ 9 4 3 3 3 5 d 4 3 1 3 5 J 4 3 4 J B1' ]415fID+mo3G11S' 3 3 2 2 T 2] 2 J 3 3 2 5 3 $ 2 2 2 41 9 2 / 3 03 3 2 6 $ 9 3 3 2 1 3 9 4] 3 4 9 3 23 2 9AA9T tETr1Or) 2 2 2 2 R 1 2 2 2 E P 2] 9 i A 2 3 3 3 3 3 3 9 3 1 9 3 3 3 3 3] 3] 3 3 9) J] 9]] 2 2 ] 2 2 3 P] E 2 T 4 2 9 3 2 4 3 3 ] 4 2 4 3! 3 1 3 1 T] 2 1 2 d 2 3 2 4 3 3 2 3 9 2' 3 2 3 2 4 2 3 P 1 2 4 2 3 1 2 4 1 4 2 t32 4 2 1 2 3 2 5 2 4 2( 3 2 5 2 4 2' 1 2 5 2 4 2( 4 2 w 21WIPIE My 314W 2 x 2 2 2 4] i P 2 2 P 3 2 3 2 2 2 4 3 3 2 4 3 3] 3 2 4 3 4 3] 1 d 3 9 1 3 S 4 3 1 3Ni116'(EpylLb) 2 1 3 1 2 22 2 2 2 2 3 3 3 3 E 3 8 3 3 3 3] 3 3 3 3 3 3 3 3 3 3 3 3 8 3 3 3 3 3 3 2 2 err319n6' 2 2 2 3 3 2 3 9 29 2 2 2 3 2 33 2 4 2 3 3 4 2 4 2 3] 4 2 4 2 3 3 4 2 4 2] 3 4 2 3u3Mr tebd' 3 2 3 2 3 2 3 2] P 3 2 9 2 3 3 2 1 2 3 1 9 2 4 2] R 1 E 4 2] 2 3 2 4 2 1 2 3 4 4 2 9 2 32 3 2 3 2 2 2 3 2 3 2 3 2 3 2 2 3 213 2 3 2 3 2 3 2 4 3 3 2 J 2 1] 4 3 9 2 4] 4 3 3 2 33e W (E00e1 Lipl 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 E 2 3 3 2 2 2 2 3 3 3 3 2 2 3 3 3 3 2 2 3 3 J 3 3 3 3 3 3 J 3 e ow 369/IB" 2 2 2 212 2 2 Z 2 2 2 2 2 3 2 2 2 2 9 3 3 2] 2 3 2 2 3 2 2 3 4 3 2 3] 3 2 2 3 3 2 3 4 3] 1 4 0 2 2 3 3 2< 9 I] 2 4 9 2 9 3 3 2 3 9 4 2 9 4 3 2 2 3 J 2 wxxr 91d4' 3 2 3 2 3 2 3 2 3 2 3 1 3 2 3 E 2Y ]1-LI'IFM 99" 3 2 1 3 2 9 2 3 2) 3 2 3 2 3 2' ] 1 2 3] T 4 2] 2 9 2 3 P 9 T 3 3 9 2' 3 2 4 3 3 21 3 2 1 3 4 3. 3 1 SP1HB•IEurl Llb) 2 2 Z S 2 2 P 21 ? 2 3 2 2 2 3 2 S 2 3 3 2 2 2 T 3 3 3 3 S 2 3 J 3] 2 Y 3 3 3 3] 3 3 9 9 9 3 J 'Lµla11P dmerwblm bdenge rtMovc sbovm. Forbuck dlmnelm subbect i". - Odell sash IiMghl. Fw tlesr daylgN beighl, aWwt 3 She renge Includes the steMard P WAew (3oreP2 wnfigurBtton) for the P1. Wlndow Hdgni. "MR^ rotors w "MeeRrg nor. For ox211 sash Wdth, SUMAK t 2-I&Sr "In the CWt dmen lon .. ' ' ANCHOR ANCHOR MIN. MIN. CLEARANCE. MIN CLEARANCE TYPE SIZE EMBEDMENT TO MASONRY TO ADJACENT.. EDGE ANCHOR:. ITW TAPCON 1/4" 1-1/4" 2" 4" ELCO ULTRACON Ile 1'1/d' WOOD SCREW INSTALLATION NOTES: MOIOLDIDOminlmum 5/A"Pdno dlelnn�a r•e..d .1,.r,....... a v�� ____e__ ANCHOR' ANCHOR `MIN. MIN. QEARA MIN CLEARANCE! TYPE SIZE EMBEDMENT. TOMASONRY RY Tb ADJACEM .EDGE ANCHOR:_' IIVI TAPCON= 7/4" 1 1/4' 2" C TAPCONe 3/16" 1.1/41, 3" 1-1/2' WOO SCR INSTALLATION NOj�t; Moinitlln D minlmum SS/S" Adae dhfoneo. 1"end rbsinnre. x I' n r. ennrtn...,Y v � E[ms��,, IN ix BUCK - I"�1 ., INSTAL(A ION iZ O fi i c F� 1 1 U DETAIL H "I' 1 W DETAIL "4" 1 SUBGRADE PREPARATION: — 1. THE AREA WITHIN THE LIMITS OF THE FOUNDATION SHALL HAVE ALL VEGETATION, TOP SOIL AND FOREIGN MATERIAL REMOVED. - 2. CLEAN FILL SAND AND OR GRAVEL FILL, FREE OF VEGETATION AND FOREIGN MATERIAL, MUST BE PLACED TO DESIGN SUBGRADE LEVEL AND COMPACTED TO .ASSURE UNIFORM SUPPORT OF THE; FLOOR SLAB. - 3. SUBGRADE COMPACTION SHALL BE ACHIEVED BY MEANS AND METHODS DETERMINED BY THE RESPONSIBLE CONTRACTOR. SOIL DENSITY TESTING BY INDEPENDENT SOILS TESTING FIRM SHALL BE REQUIRED TO INSURE PRESCRIBED SOIL DENSITIES ARE ACHIEVED. 4. PROPOSED NEW MASONRY WALL FOOTINGS SHALL BE PLACE ON UNDISTURBED EXISTING SOIL. AFTER FOOTING EXCAVATION, AND FORMING, CONTRACTOR SHALL RECOMPACT SUBGRADE SOILS USING SUITABLE VIBRATORY MECHANICAL COMPACTOR. THE UPPER 16 INCHES OF SOILS UNDERLAYING THE WALL FOOTINGS SUBGRADE SHOULD HAVE A MINIMUM DENSITY OF 95% OF THE MAXIMUM DRY UNIT DENSITY AS DETERMINED BY MODIFIED PROCTOR METHOD FOR WA=,yIY_����I �" THE EXISTING SOILS PER ASTM D-1557. IN —PLACE SOIL DENSITY TESTS SHOULD BE PERFORMED IN ACCORDANCE WITH ASTM D-2922, AT A FREQUENCY I`'� DETERMINED BY THE SOIL TECHNICIAN TO VERIFY UNIFORMITY OF THE UNDERLING SOIL DENSITY, PRIOR TO PLACING CONCRETE, BUCK INSTALLATION TREAT THE MASONRY OPENING WITH A CMU WATER RESISTANT COATING TO 5. SUBBASE COMPACTION FOR THE FLOOR SLAB FILL MATERIAL SHALL BE UNIFORMLY COMPACTED TO A MINIMUM DENSITY EQUAL TO 95% OF THE MAXIMUM 1. PRIOR TO B.. - DRY UNIT DENSITY OF THE SOIL FILL AS DETERMINED BY MODIFIED PROCTOR METHOD IN ACCORDANCE WITH ASTM D-1557. SEAL_ THE WINDOW / DOOR CAVITY TO PREVENT IT FROM ABSORBING WATER. THE C A WATER RESISTANT ED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. THE 6. PLACEMENT OF CONCRETE SHALL NOT COMMENCE UNTIL SUBGRADE PREPARATION REQUIREMENTS AS SPECIFIED IN THESE NOTES HAVE BEEN MET, COATING SHALL BE APPLIED UNLESS OTHERWISE SAND CERTIFICATION OF TERMITE PROTECTION SOIL TREATMENT IS OBTAINED FROM A QUALIFIED PROVIDER APPLICATION OF THE CMU WATER RESITANT COATING SHALL INCLUDE DIRECTION. ALL IN ACCORDANCE WITH PROVISIONS OF THE FBC—RESIDENTIAL, SECTION R318. OPENING (SILLS, JAMBS, HEAD) AND RETURN WALLS OF THE OPEN INUCK INSTALLATIONS. lJ TER RESISTANT COATINGS SHALL BE INSTALLED PRIOR TO B 7. CONCRETE SLABS ON GRADE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER WITH A MINIMUM THICKNESS OF 6 MILS, INSTALLED WITH LAPPED CM WATER JOINTS NOT LESS THAN 6 INCHES AND CONTINUOUSLY TAPPED WITH HIGH DENSITY POLYETHYLENE ADHESIVE TAR 2. INSTALL BUCKS SO THAT THERE ARE NO EDGE GAPS EXCEEDING 1/8" BETWEEN BUCK AND MASONRY. DIAMETER BEAD OF SEALANT BETWEEN THE BUCK 3. PRIOR TO BUCK INSTALLATION APPLY 3/8" NOMINAL AND THE MASONRY TO PREVENT THE PASSAGE OF LIQUID .BEHIND THE COMPLETELY THRO.UGH THE ENTIRE END OF THE WOOD BUCKS WITH SEALANT TO RESTRICT THE PASSAGE OF THE BUCK SHALL BE COATED WITH STUCCO CEMENT FINISH CUT ENDS AND THE ENTIRE EXTERIOR FACE AND RETURN SURFACE OF t A LIQUID APPLIED WATER RESISTIVE COATING / SEALANT. OF WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR FILLED CELL AT JAMB BLOCK (TYP) q: PROVIDE PAN FLASHING AT SILL SURFACE OF THE EXTERIOR WATER RESISTIVE BARRIER CMU WATER RESISTANT COATING ? SLOPED IN A MANNER TO DIRECT WATER TO THE R (SEE WATERPROOFING NOTE #1)' FOR SUBSEQUENT DRAINAGE. INCORPORATE PAN FLASHING AT HEAD AND SILL AS WELL. PAN.FLASHING SHAI...L BE CORROSION RESISTANT (OPTIONAL NOT REQUIRED IF ITEM #1=3 INSTALLED).- 5. PROVIDE CONTINUOUS 3/8" BEAD OF SEALANT ON .WINDOW / DOOR FRAMES AT ALL PERIMETER ON FRONT ° •.'c WINDOW /DOOR INSTALLATION. g ° AVID BACK SURFACE PRIOR TO 1x3 P.T. WOOD FIRRING ALL (3) SIDES 3 a CONTINUOUS BUCK (OR PRE 6. AFTER WINDOW/ DOOR INSTALLATION PROVIDE FOAM SEALANT BETWEEN THESEAL AROUND THEAST ENTIREL) WOOD TRIM AND 11-IE WINDOW / DOOR TO ENSURE A WATER RESISTANT INTERIOR AIR PERIMETER, CORROSION RESISTANT FLASHING PER WATERPROOFING NOTE #2 ix6 P.T. WOOD BUCK �ATN SEALANT PER WATERPROOFING NOTEI#4 AND ANCHORED TO UHL MASONRY w/ 1—Y2" CASE HARDENED COIL APPLY WINDOW D AND DOOR FENESTRATIONS SHALL BE IN ACCORDANCE WITH FMMA. /. AMA 200=9. CONTRACTOR BETWEEPERIME ER WINDOWSEALANT FCAULK NAILS 012" O.C. MAX. . SHALL SUBMIT FMMA / AMA 200-9 STANDARDS WITH PERMIT SUBMITTAL. (SEE WATERPROOFING NOTE #5) SEE WATERPROOFING NOTE #6 ANCHOR DOOR JAMB HEADER TO MASONRY IN /AI TERNATE BUCKS: STRICT ACCORDANCE WITH MANUFACTURE'S IN LIEU OF BUCK SIZE AS STATED ON PLANS FOR WINDOWS; SGD, ,AND SWING DOORS THE USE OF 2X4, PRODUCT APPROVAL INSTALLATION REQUIREMENTS. 2X6, 2X8, 1X6, 1X8, DOUBLE 1X6, ,OR DOUBLE 1X8 IS ACCEPTABLE, fl I_ B 8 MLLST PF -PRES�SU �E T - ALL BUCKS4iiUST' COVE E�NTIR. DEPR T THE M. OR/WINO`eW JAW • FOR 2X BUKS ATTACH TO CMU WALL WITH YV x 1 3/a' MINIMUM EMBEDED TAPCONS AT 4" FROM CONERS AND 12" O.C. (TYPICAL) EXTERIOR DOOR BUCK DETAIL —� SC ALE: N.T.S. STUCCO CEMENT FINISH FILLED CELL AT JAMB BLOCK (TYP) CMU WATER' RESISTANT COATING I (SEE WATERPROOFING NOTE #'1) 41 ° - STUCCO CEMENT FINISH CORROSION RESISTANT FLASHING—� O PER WATERPROOFING NOTE #2 ° ... ° � —1x3 P.T. WOOD FIRRING ALL (3) SIDES CONTINUOUS "FILLED CELL AT JAMB BLOCK (TYP) t CMU WATER RESISTANT COATING (SEE WATERPROOFING NOTE #1) ° APPLY PERIMETER SEALANT CAULK SEE WATER PROOFING NOTE #8 t ° BETWEEN BUCK'& WINDOW FRAME A..•.c 1 .o. 10 P.T. WOOD FIRRING ALL'(3) SIDES CONTINUOUS (SEE WATERPROOFING' NOTE #5) ANCHOR ix4 P.T. (MIN.) BUCK WITH SEALANT i PER WATERPROOFING NOTE #4 AND ANCHORED WOOD TRIM TO MASONRY WITH 'I—y2" CASE HARDENED COIL NAILS 012" O.C. MAX.** 2x8 P.T. WOOD BACK WITH SEALANT' PCR ANCHOR WINDOW FRAME TO MASONRY IN STRICT APPLY PERIMETER SEALANT CAULK WATERPROOFING NOTE #4 AND ANCHORED TO ACCORDANCE WITH MANUFACTURE'S PRODUCT BETWEEN BUCK &WINDOW FRAME MASONRY WITH Y4"O (FH) TAPCONS ® 4" FROM END APPROVAL INSTALLATION REQUIREMENTS.** (SEE WATERPROOFING NOTE #5) AND 12' O.C. (STAGGERED) TAPCON LENGTH TO. NOTE; PROVIDE,1-3i" MASOR'/ EMBEDMENT..._ SEE WA'IERlr'KUUruw i-40TL #o WINDOW FRAME SHOULD BE COMPLETLY SEATED ON THE BUCK. IN NO INSTANCE SHALL THE FRAME OVERHANG THE CORROSION RESISTANT FLASHING. Bl1Cit.. PER WATERPROOFING NOTE #2 ANCHOR DOOR JAMB NNIJ .HEADER TO 2x BUCKS IN. STRICT ACCORDANCE ITH MANUFACTURE'S ** FOR GLASS BLOCK WINDOW PROVIDIE MINIMUM 2x4 P.T. WOOD BUCK WITH Y4'OY2" MIN. EMBED. TAPCONS AT 4" PRODUCT APPROVAL' I STALLATION REQUIREMENTS; FROM CORNERS AND 8" O.C. ANCHORS FOR GLASS BLOCK WINDOW SHALL BE INTO THE BUCK AS PER MANUFACTURERS SPECIFICATIONS: _ WINDOW HirADE R AND JAMBS TYP. BUCK DETAIL Y SLIDING GLASS DOOR BUCK DETAIL NOTE: GLASS BLOCK BUCK SIMILAR SCALE: N.T.S. SCALE. N.T.S. (2) #5 IN FULLY GROUTED CELLS ADJACENT TO.GARAGE DOOR: OPENING AS SHOWN CONTINUOUS FOAM INTERIOR AIR FASTENERS AS REQUIRED BY WINDOW MANUFACTURER AND WATER SEALANT PER WATERPROOFING NOTE #6 CORROSION RESISTANT FLASHING PER WATERPROOFING NOTE, #2 MARBLE SILL —� CAULK SEAM AT WINDOW INSTALLATION p Q. (SEE WATERPROOFING NOTE #5) +' CMU. WATER RESISTANT COATING MORTAR OR n. a .� , (SEE WATERPROOFING NOTE #1). GROUT , .. I • SET SILL IN FULL MORTAR BED STUCCO OR DECORATIVE CEMENTITIOUS COATING \ Y2 DRYWALL 2x6 P.T. (SYP) WOOD JAMB FASTENED w/ %"x3-Y2" 8" C.M.U. (S.S. 304) HILT[ KWIK BOLT 3 EXPANSION ANCHOR (OR EQUAL) w/ 2"- SQUARE WASHER SPACED 01 O.C. MAX.' -Y4" FURRING TO MASONRY WALL STEEL TRACK BRACKETS TO BE FASTENED TO WOOD . r8xa - 2x6 BUCK w/ PER GARAGE DOOR MANUFACTURER'S - SPECIFICATIONS (OR AS NOTED BELOW) N ; PRECAST_ CONCRETE WIND RESISTANT'FLUSII OHGD TRACK BRAGI<ETS TO P.TBUCK SILL AS MANLIFACTURERD BY CAST—CRETE (OR EQUAL) 7' HIGH DOOR: (7) V16' x 1—%" LONG CORROSION RESISTANT HEX HEAD LAG SCREWS SPACED PER MANUFACTURER'S INSTALLATION INSTRUCTIONS: NCRETE WINDOW SILL DETAIL OHGD BUCK DETAIL PRECAST C(7 _ -- -- SCALE: N.T.S. SCALE: N.T.S. r-e- V / " l { WALL FINISH / INSULATION NOTES 1) INTERIOR TO BE Ye" DRYWALL FINISH. 2) ALL INTERIOR GYPSUM BOARD TO BE MIN. 1/," THICK WITH (1.3 GAGE, 1 /8" . LONG, 19/64" HEAD; 0.098" DIAMETER, 1'/4" LONG, ANNULAR -RINGED; 5D COOLER NAIL, 0.086" DIAMETER, 1 5/8" LONG, 15/64" HEAD; OR GYPSUM 30ARD NAIL, 0.086" DIAMETER, 1 5/8" :LONG, 9/32" HEAD) SPACED AT 7" O.C. FOR AILS AND 12" O.C. FOR SCREWS. 3) WALLS AT SHOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR LASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR C 1278 AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS AS BACKERS FOR WALL TILE IN TUB AND SHOWS It AREAS AND WALL PANELS IN SHOWER AREAS. (PER FRC 702.4.1 & FRC 702.4.2). 4) WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED If X OF NOT GREATER THAN 450. 5) WALL AND CEILING FINISHES SHALL HAVE A FLAME -SPREAD CLASSIFICATION OF NOT GREATER THAN 200. 6) ALL EXPOSED INSULATION MATERIALS INSTALLED, ON ATTIC FLOORS HALL HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.1.2 WATT PER SQUARE CENTIMETER, EXPOSED FOAM PLASTIC INSULATION MATERIALS EXPO ED TO THE UNDERSIDE OF THE ROOF DECK OR ON THE ATTIC WALLS SHALL COMPLY WITH SECTION FRC316. 7) PER FRC 702.2.1 ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SH kLL CONFORM TO ASTM C 36, C 79, C 475, C 514, C 630, C 931, C 960, C 1002, C 10. 7, C 1177, C 1178, C 1278, C 1395, C 1396 OR C 1658 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF FRC, AND ADI3ESIVES FOR THE INSTALLATION OF GYPSUM BOARD SHALL CONFORM. TO ASTM C 557 8) INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR-CEIL1 NG. ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EX ED 25 WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. ENERGY CONSERVATION NOTES 1) RESIDENCE SHALL BE IN ACCORDANCE WITH FLORIDA BUILDING COD 2014 / ENERGY CONSERVATION RESIDENTIAL. L 2)2) N / r_ )_ 3) / WINDOWS, SKYLIGHTS, AND SLIDING GLASS DOORS SHALL HAVE AN AIR. n INFILTRATION RATE OF NO MORE THAN 0.3 CFM PER SQUARE FT, AND SWINGING DOORS NO MORE THAN 0.5 CFM PER SQUARE ITT AND MUST IF E TESTED LISTED AND LABELED 1N ACCORDANCE WITH R402.4.3. 4) CONTRACTOR Sl IALL PROVIDE ENERGY PERFORMANCE LEVEL (EPL) D SPLAY CARD 1N ACCORDANCE WITH FBC 2014 ENERGY CONSERVATION R401-3. MasonryMBHU , .. - The new MBHU beam hanger provides, aface-mounted solution for connecting beams to masonry or concrete walls. A non -welded, L--w one-piece connector, the MBHU is su,table for solid sawn and engineered wood beams as well as trusses. Installation is simplified because the Titan HD®heavy-duty screw anchor and Strong-DriveQ SOS Heavy -Duty Connector screws are included with the hanger. Since the Titan Hq anchor is installed after the Lite"for9'/4" \ wall is built, locating the anchorinthe right spot IS easier than Mortmodels with cast -in -place bolts. - 2Y=oilolhers ,a MATERIAL: 10 gauge` FINISH: Galvanized Htiz INSTALLATION: • Use all specified fasteners (Included).. s;n • Attach hanger to a concrete or grouted CMU wall using..."*^ ° °- Titen HD anchors. Note the following:r:''. �- - Drill holes using drill bits equal In diameter to the specified Titan HD anchor. - Holes shall be drilled V deeper than the specified Titan HD length (i.e. 5W fora Flung Titan HD anchor) ,. - Caution: Oversized holes in the base material will MBHU Typical MBHU I stallation reduce or eliminate the mechanical interlock of LET yl the threads with the base material and will reduce the anchor's load capacity. ` •Titan HD is not recommended for exposed U exterior applications. ;�, r ae / ix i' r( sr (•$ 7^ " �`` ts • Provide moisture barrier between beam -' -' } _ ", t" �'' and wall per jurisdictional requirements. 1/4"x2Yz' Strong -Drive® SIDS " CODES: See page 12 for Code Reference Key Chart, HEAVY-DUTY CONNECTOR Screw Titan HD® WxY Screw Anchor 1 Model No Dimensions Width (W) (to.) Height (H) (in.) MBHU3.56/9.25KT 34/ie 9'/a MBHU356/1125KT 3Ad 11'/a MBHU356/1188KT Vie 11% MBHU3 56/14KT 3V6 14 MBHU356/16KT 1 3°/,e 16. MBHU3 HAWT 35/c 18 MBHU5.50/9.25KT 5%a 9'r; MBHU5.50/11.25KT 5'fe 11'/< MBHU550/1188KT 5'f: 11% ,M',BHU560/14KT :% 51i 14 MBHU550/161<T MBHU550/iBKT % `5:f 18 Dimensions ,l Allowable Loads Allowable Loads (to.) Fasteners End of Wall/Outside Corner Awayfrom Edge j DF/Slo DF/SP Series, Model Ga CMU/ .CMU Concrete CMU/Concrete Code No, Concrete) Joist Uplift'�Downloa plift Download.. Upldt Download Bet.. W TO 8 Titan HD°d .SDS _ (180) (100/ _ (160) (100/ (160) (100/ Anchors Screws 1151125) r)'1',1151125),. 115,125) 9'G to <14 11720 2440 2715 4190 2219 4005 MBHU866 10 A. 3Ys 2 3/x5 12-'/a x2'1A 17 00 2440 2715 4190 3341 i 6065 14 to 18 "'.6 j8 3pcJ --'�"PPM1~Hx. '1'r zHt, r,+t�7�2`Or?,L> 4ruiW.'2 z21 9Q4+8�:, F24 J�I9H 10 5a, d ufy 1 1. Uplift loads have been increased for wind or earthquake loading with no further Increase allowed; I reduce where other toads govern. 2. Minimum CMU compressive strength f'm shall be 1500 psi and conerate compressive strength Pc shall be 2 500 psL I 3. Structural composite lumber (SCL) shall have a minimum specific gravity of 0.5. 4. Allowable loads only apply to installation on 8" nominal grouted CMU walls, with minimum one horizontal 85 rebar located In the top course. 1. Each MBHU hanger includes 5. Products shall be installed such that the Titan HDe anchors are not exposed to the weather.' 6. Allowable loads are based upon the tested ultimate load with a safety factor of 3. l (2) %"x5'Titan HD®anchors and I > (12)'Gx2Yd Strong-Drive®SDS ? Heavy -Duty Connector screws. - i - i Minimum one Minimum one Minimumone horizontal $5 rebar 14 W horizontal /5 rebar horizontal €5 ral loraled in top course .. 11i5'—� ar 54w .' ' located in top course min. located In toDc rs8 s I o z rC? HD - inch ' anchor 77 1r Installation at Outside Corner Inst illation an (Minimum Load) Eit J at Wall (Min mum Load) Installation Away from Edge of Wall ` (Maximum Load) SHEET NUMBER PA IJL WELCH INC. ! , MECHANICAL ELBC7"R/CAL CIVrIL A(G1A1EER/NG Y9B4 s. w. B/L nwoRE sr. SUIT # 1 14 - PORTST, LUCIE, FL 349214 4 PHOA/E(77?)785.9888 F�1?A/L PWEL H/lVC@AOL.COp.I PAUL LYE'LC/-/, P$; FL REG Are . �?9945 a APR 1 2 200 _ II 3 # 3/0 THW IN 2" C _ ELECT. SERVICE ELECTRICAL LOAD CALC'S ELECTRICAL NOTES 3 # 3/0 THW IN 2' C PER NEC 1) ALL ELECTRICAL WORK SHAL BE IN ACCORDANCE WITH THE NEC (NFPA 70) UNDER GROUND ELECT. SERVICE 1696 S.F. @ 3 VA 5088 VA 2011 2) MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING _...,,.... TWO 20A APPLIANCE CKTS 3000 FA o FIXTURES SHALL BE HIGH-EFFACY LAMPS OR A MINIMUM OF 75 /o OF THE _ • e/ LAUNDRY 1500 PERMANENTLY INSTALLED LIGHTING HTING FIXTURES SHALL CONTAIN ONLY 20D 120 / 240V / 2 O 20U 2 120 / 240V 1 DRYER 5000 HIGH-EFFACY LAMPS. (LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED TO BE HIGH-EFFACY LAMPS) 2 1� 2 RANGE 12000 3) RECESSED MDR 200A WH 4500 BE SEALED TO LIMIT AIR LEAKAGE BETWEEN LIGHTING SHALL.. MDR 200A MLC DW 1200 CONDITIONED AND UNCONDITIONED SPACES. MLO WP TUB (OPTION) 1200 4) SMOKE DETECTORS TO BE 110V W/ BATTERY BACK UP —ARC FAULT CIRCUIT 5) SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE REFRIG 1200 DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE _ IRR. PUMP (OPTION) 1800 6) PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FOR ALL CIRCUITS I f MISC 10000 SERVING: FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, 3 # 3/0, #4, 2" C1 3 # 3/0, #4, 2" C TOTAL 46488 VA LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS PER #4 CU GRND TIED FIRST 10 KW @ 100% 10000 FBC AND NEC REQUIREMENTS. 7) PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 125- #4 CU GRND TIED TO BLDG STEEL, CWP REMAINDER @ 40% 14596.2 VOLT, SINGLE-PHASE 15 AND 20 AMP CIRCUITS SREVING: BATHROOMS, STEEL, GARAGES, KITCHENS, ACCESORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF ND AND DRIVEN GRND ROD AN DRIVEN AND DRIVEN GRND ROD TOTAL 24595.2 EDGE OF ANY SINK. • 8) CARBON MENOXIDE DETECTORS TO BE INSTALLED WITHIN 10' OF ALL A/C HEAT CN 100% 12000 BEDROOMS. 9) EXHAUST FANS TO BE VENTED T HR U ROOF OR SOFFIT. 36595.2 VA 10) PROVIDE TAMPER RESISTANT RECPTICLES PER NEC REQUIREMENTS. ,. _. TOTAL NOTE: USE ALL COPPER WIRE. NOTE: USE ALL COPPER WIRE. 36695.2 240 = 152 AMPS ELECTRICAL RISER / DIST. nts.._ ELECTRICAL RISER / DIST. Ms.._ OPTION "A" OPTION "B„ USE 200 AMP SERVICE EXHAUST FANS SHALL MEET THE FOLLOWING CRITERIA: °` - Ventilation rate. Ventilation systems shall be designed to have the cavity to exhaust the minimum air flow rate determined in accordance with Table TABLE M MINIMUM REQUIRED EXHAUST RATES FOR ONE- AND TWO-FAMILY DWELLINGS .,.�. _........ L. _ ^ _ / AREA TO BE VENTILATED VENTILATION RATES 100 cfrn intermittent; or Kitchens 25 cfm continuous Mechanical exhaust capacity o Bathrooms —Toilet Rooms 50 cfm intermittent or 20 cfm continuous =LIFE SAFETY WARNING This symbol identifies Life Safety Warnings that should be read given special attention by all persons installing trusses. SPACING NOTE ALL TRUSSES ARE TO bE 5ET AT 2'-0: ON CENTER EXCEPT AS NOTED MULTIPLE PLY TRUSSES MUST BE ASTENED TOGETHER PER ENGINEERING BEFORE SETTING. REFER TO ENGINEERING DRAWING TO DETERMINE JA IF MULTIPLE PLY. All n DON'T LIFT TRUSSES WITH SPANS LONGER THAN 30' BY THE PEAK. 30' Span or less 60 degrees or less f-- 1 /2 —s Tag Line span approx. REFER TO BCSI I Truss must be set this way if crane used. 'Tmss is on exempla, your truss may not match. Insist crane operator sets truss this way. 30' to 60' Span AL SDreader Bar Ling �. Approx 2/3 to—_� Line 1/2 of Span REFER TO BCSI ass must be set this way if crone used. This is an example, truss may not match. Insist crane operator sets truss this way. All load bearing walls, headers, beams & lintels must be in place at indicated height before trusses are installed. A AIIR FiA"®1_IE—=FZ N4L7TII UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS. CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR. For Truss to Truss Connections see hanger/connector schedule in engineering package. w Carrying Girder a3 tabs ails. SEA .LATES BY CHAMBERS ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 23' - 30' IN LENGTH Do not stand on trusses until they are braced per BCSI & properly nailed to straps & hangers PIGGY BACK TRUSSES MUST BE ATTACHED AND BRACED PER ENGINEERING DETAIL!! METAL ROOFS SHOW IMPERFECTIONS. SPECIAL INSTALLATION CARE MUST BE TAKEN upset=1/4" heel=4 5/16" PLUMB CUT END 2 x 4 Top Chord WALL HEIGHT 8' TYPICAL END DETAIL INDICATES LOAD BEARING - REQUIRED BY TRUSSES SUPPLIED BY BUILDER AT A HEIGHT OF 8'-0" ABOVE FINISHED FLOOR 0? � I 1 — — _ — _ — — — — — — — ` — — — — — — — — — . ,. � / \♦ ���----ram `\ 12 7.00 12 700 \ / \ / 12 1 \ i 4.00 f 1 1 12 F.00 \ 1 1f I— r tD If 1 1 st ! fl i0 1 6— Vn it 3 „ / 1 ' 3 i / ±\` upset=l/4" heel=315/16"--�� a ♦ ♦\ upset=1/4" heel=3 15/16" / i 1 PLUMB CUT END 1 10 \\ \ \�, PLUMB CUT END- 2 x 4 Top Chord 7 2 x 4 Top Chord f \ WALL HEIGHT 8' 7 1 \ \ WALL HEIGHT 8' f k # \ END DETAIL: FRONT PORCH \ f ♦ �/ \ END DETAIL: BACK PORCH / it JIF a A MATERIAL & LABOR TO ATTACH PIGGYBACKS IS THE RESPONSIBILITY OF THE BUILDER. FAILURE TO ATTACH AS SHOWN CAN RESULT IN FAILURE OF ROOF, INJURY AND LOSS LIFE. FAILURE CAN OCCUR DURING INSTALLATION OR LATER B19«91`Y Ww 11r tbx Pingaa QISSEr u.D tnuws lmrd BmcF9 e 24- MAX OC 36- MAX OC BuAdr/imn motor«mowed, P4er bad; wr m ear ® .t "IM a'zb'xl/Y mY' W ., a matlmum betr vIM { d t comm Be s pnot o of P199Y e, rmr rd tap m«d or ero wad terns ra r mu mod to, of wrm aoeten m«e of P"w9r e am aa ror too m«e a ere nur ra eoaed o mex:"om er 34' m rntr wI1F 2N cwYnuwa lat«W precm& Nxxr I.w.l aedw r e.r m.e a rt I q" T-8` 6'-4" 30'_4" NOTES: * ALL CEILINGS ARE FLAT. CLOUZSED AREAS ARE OF // SPECIAL CONCERN & MUST BE \I CHECKED CAREFULLY & MAY f 1 INDICATE DEVIATION FROM ♦\--PLANS.,-- * ALL BEAMS ARE BY OTHERS. * PIGGYBACKS SHOWN OFFSET FOR CLARITY. * BUILDER TO VERIFY ALL END DETAILS. 11 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT la SIGNED 3 RETURf The lapel description of the property Where the trusses will be Installed Is: 7. Imaa08 wlll'b8 made In B" aCCOfdanCO 1YIth this Iruas pl,Cement dlagrem II vrfilbh b the sole aAll om� uNorlry for determining suLxessful fabncedon of the buasea. ,3'. Unless written notloel la provided by caertl'mfied men to Dhamlbera TMae within tan '.eye of delNery the underalgned agrees that no baokcharpea will be allowed. In the e� such Written notice Is fumishad Chambers Tel n ,hell have three (3) bugJ�eas days In vd to, bagln repelre required, or to oubstiMe other trussaa, e< Chambers opthTn. ¢.The undereipnad ecknowledgea receipt of "SCSI 1 at summery sheet by TPI & WiG Sy D0 very la to job alto. It fa the buyers'responslblllry to make Na Job site suitable delhiery. Ch,mbi s Tnrsa has the acts authority to determine me suitability of the Job site e pdrtidn of the job she for delNery, Chambers Trues will be responsible for dump delivery of The tiuyar la reeponisto a for eddidonal delivery expan,ea d Chambers Trues has to redell because job site le dot prepared for del or buyer la not prepared for del Nery of trues auyeab responalble to Chore re Truss for towing coats due to ells wndltiona. t.9;;Price ee ehowrl In paragraph 7 below Ia aubjaq to change H any changes are. matle ihledayduL A S6o par hour fee for revlalons maybe charged by Chambers TNas. '`q'.ihle Is a PUgCHASE ORDER to Chambare-Truss of the sum ogread to, or If AD illu`nent a reasonable prke. Involve will be made on delNery and paid Wlthln terma of r oniVelivery. Involoo may be made at scheduled date of delivery B buyer cannot acts 8'$11 of fabricated trusses, The underelgned agrees to pay Chart bere.TNea easons! ettbmeYs fee for callecdbne In event of payment not timely made. amb rs per month servh charge wgl ba addedPo, ell sums not paid wlfhln terra. B: Slgnefure or Initleleenywhere on this sheet conatitutas egreamem to ell termahereln. >S..In donaWeradon of Chambers Truss extending tc, for this materiel the underelgnB lnwn nTsly guanantees payment when due of any and all Indebtedness owed I .hemben TNsa byany entity recelving metedel and the undarelpned agrees to pay suc ndebtedness Including -*meys fees, If default In payment for metedel be made by th eciplent. 10. In:a event of any Iltigation wnceming this agreement, the hems tumlehed hereunde f peyIT a referred to herein, the. partlea agree that the sole venue for any such action Wd e Stht Hide County, Florida. )L1;Opalpn respondblllpea are par -'National Standard And Recommended Guidelines On aeponsibllltles For Clonstruetion UsInp N$1/LPIANCA Metal Plate Connected Wood Trusses T4- ATED r2-)2-5 . 2002 - �' kcU t /.. . I— r Ail~� — 4 TITLE 2' -Z - INultlple ply trusses must be fastened together per engineering `*161"S they are set; failure to do so can result In roof collapse. `6 jnporary and permanent bracing are required and can save life wand propertyand Is the responsibility of the truss erector. *dy the contents of the Information packet Included on delivery 5 before setting trusses. r,Trewsmustbeastandbraced perdesignt. pLeuerltir ,g Trusses must be pidmb and squpare Do riot Oat bunks or stack of plywood, roofing material or any ,oer co'hcentrated loads on trusses, this can cause collapse. DO NOT SET TRUSSES USING THIS LAYOUT U$E_ E LAYOUT DELIVERED WITH TRUSSES To SET TRUSSES CHARIIBERS TRUSS INC All. 3106 Oleander Avenue Fort Plerce; Floll'Ida 34982.6423 800-551-5932 F$jt Plerce 77:2.465-2012 Fax 772486-8711 Vero Beach 772-569.2012 Stuart 772-2863302 WaI h SIII CHAMBERSTRUSS.COM 92.0/93.2 MITEK 4.2 DESIGN CRITERIA County SAINT LUCIE Building Department ST LUCIE COUNTY Wind Design Criteria ASCE 7-2010 Wind Design Method Main Wind Force Resisting Roofing Maternal Metal Roof Loading in PSI= Roof R.D.L. Top Chord Live 20 Top Chord Dead 7 4.2 Bottom Chord Live 10 Non -Concurrent Bottom Chord Dead 10 3 TOTAL Load 37 7.2 Duration Factor 1.25 Wind Speed 160mph Top Chord C.B. Sheeting by builder. Bottom Chord C.B. Sheeting by builder. Highest Mean (Height 21'-01' Building Type ENCLOSED Building Category II:Non Restrictive Exposure Category C Barrier Island No Conforms to FBC 2014 Verify DESIGN CRITERIA shown above with the ,4 building department and your engineer. Design Criteria is the responsibility of the Buildinci Designer and/or Engineer of Record. Chambers Truss Inc. Drawing Name;::74085 Scale: 1/4 = 1' 49 total trusses, 11 different trusses. I 0u;,,I A%,IUnUF I MI 4: RLC ACAD: RLC Reviewed By:j&; ..1 Date: 01 /31 /17 FOR ONE CONISTRUCTION SER. PAULWEI DESCRIPTION: ME°H-ELE°, 1984 BI1-7M0 LACKEY PORT SHIN, LIL wAULvvE FLA REG I PAGE 1 of 1 CUSTOMER INITIALS EAC 74085