Loading...
HomeMy WebLinkAboutGas Piping SchematicBOARD OF COUNTY COMMISSIONERS GAS PIPING SCHEMATIC [A2] [A4] V;�o P!3T [L4] [L8] OWI lae- -aei 1aAr7 l-1-27 .I ianl la,w IIiIV1% 1 LLJj LL;21 LLI LL.7jL11 SIZE 1.21 [1.6] [1.10] [A1] [A3] [AS] TANK SIZE: GALS. APPLICANCE — TYPE/SIZE Al BTU A2 BTU A3 BTU A4 BTU A5 BTU A6 BTU PIPING LENGTH & SIZE L1 1 FT. 'INCH DIA. L2 FT. INCH DIA. L3 FT. INCH DIA. .L4 .FT, WGH DIA. L5 FT. INCH DIA. L6 FT. INCH DIA. L7 FT. INCH DIA. L8 FT. INCH DIA. L9 FT. INCH DIA. L10 FT. INCH DIA. L11 FT. INCH DIA. L12 FT. INCH DIA. Revised 7/22/14 PLANNING & DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulation Division ST. LIJCIE COU REVIEWEDREV'q WED FOR BUI I L ADIV/S101V DATE CE PLANS AND P ER;;M�..1&AjI OR NO 1 NSP EECTION ST LON JOgWILE MADE, (PIPE SIZE WAS TAKEN FROM THE 2014 FBC FUEL GAS CODE - TABLE 402 (3P4 a-U ) ,1017 F6c1 (2AIV I Co?PLO- i CSST ST LUCIE COL': REVIEWAQ FL, VNUB 0'__ PERMfi'.' OR NO IN. Website: wm.stluciecg,gov 2300 Virginia Avenue - Fort Pierce, FL. 34982-5652 Phone (772) 462-1553 FAX (772) 462-1678 i 11/12/2020 Propane Tanks Sizes - DOT 5 lb - 200 Ib - Propane Tank Store Sizes - DOT 5 lb - 200 lb Tanks DOT 5 lb 200 lb Steel Propane Tanks. d Features: cJQ� a • Propane Tanks Range in size from 5 to 200 lbs. • Used in a variety of applications - domestic, recreational, commercial, and industrial. • Manufactured in one of the most up-to-date, state-of-the-art cylinder facilities in the U.S.A. • Conform with strict compliance to DOT specifications 4BA, .413%. and 4E. In addition, most cylinders conform and are approved under Transport Canada specifications 4BAM, 4BWM, and 4EM. • Multiple testing procedures conducted for all cylinders. • Steel shot blasted prior to painting. • For maximum rust -protection, al[ cylinders coated with Powder Coat Paint. • Features HANDLE-EZ collar design, which is standard on 5 to 40 lb. cylinders. • Easy -to -read consumer warning decals included for you and your customers' protection. • Horizontal cylinders available in 20# and 30# capacity. • Capacity gauges available in 20#, 30#, 33#, 40#, 43#, and 200# cylinders: • Cylinders are shrink-wrapped on pallets, or boxed individually, for protection and easy storage. Standard Units PRODUCT DATA PROPANE WATER LENGTH DIAMETER TARE CAPACITY CAPACITY OL D WEIGHT Catalog No. Description. lb gal lb in in lb 5#.D.OT Vertical. 10054 5 1.2 13 12 8 10 ACME/OPD Cylinder 10228.4 10# DOT Vertical ACME/OPD Cylinder 10393.1 11## DOT Vertical ACME/OPD Cylinder 20# DOT Vertical 10504 ACME/OPD Cylinder,Gray 20# SureFlame DOT Vertical 1057710504TC.100 ACME/OPDCylinder, Easy to Read Gauge, Gray 20## DOT Horizontal 10487TC ACME/OPD Cylinder,Gauge 1160TC.5 30# DOT Vertical ACME/OPD Cylinder 30# DOT Vertical 1166TC.2 ACME/OPD Cylinder, Gauge 30# DOT Horizontal 1175TC ACME/OPD Cylinder,Gauge 1220.13 40# DOT Vertical ACME/OPD Cylinder 10 2.4 23.8 17.4 8.9 15 11 2.6 26.1 12.4 12.2 14 20 4.6 47.6 18 12.2 18 20 4.6 47.6 18 12.2 18 20 4.6 47.6 17.4 12.2 21 30 6.8 71.4 23.4 12.2 25 30. 6.8 71.4 23.4 12.2 26 30 6.8 71.4 23A 12.2 31 40 9.2 95.2 29.4 12.2 32 https:/Miww.propanetankstore.com/si7es-dot-54b-200-lb-tanks/ 1/2 11 /1212020 Propane Tanks Sizes - DOT 5 lb - 200 lb - Propane Tank Store PRODUCT DATA PROPANE WATER LENGTH DIAMETER TARE CAPACITY CAPACITY OL D WEIGHT 4V fh-1J W d • vertu ;a1 1222TC.2 ACME/OPD` 40 9.2 95.2 29.4 12.2 32 Cylinder,Gauge 14990TC 50# Vertical Cylinder 50 11.4 119 27.4 15.1 42 - POL Valve 1426TC - POL Valve 60 13.7 143 43.1 12.2 46 1428 100# Vertical 100 22.9 238 46.6 15.1 70 Cylinder - POL Valve 100# Vertical 1430 Cylinder - POL Valve 100 22.9 238 46.6 15.1 72 - Scr6WCap 100# Vertical 1436 Cylinder - Multi 100 22.9 238 46.6 15.1 71 Valve 100# Vertical. �itinoar -'Uquid 1439 POL Valve -Collar 100 22.9 238 46.6 15.1 71 Type 200# DOT 4BW240`n~� �1420SC11H�Vertical"Cylinder, t .r 200 --.-. -- 45:64.7.6w,° MultiValve, Gauge 420# DOT 4BW24 C1499TC.111-11- Vertical Cylinder,Quadrifitt 420 95.9 1,000 53.8 30 278 Valve 100# "Mini" ASME F�21i4 31!! 1:fe37r IA'61 T15AL 7Jzn .—U-u. �u�uy. �.vv -inn v_.. 13,30 c .v `3aa wv 1374 vi. ay 4V PSI, 21iole, Gauge 200# ASME Vertical 6765.11 HL Tank, 250 PSI, 200 45.6 476 41.9 24 188 MultiValve, Gauge Metric httpsJ/www.propanetankstore.com/sizes-dot-6-lb-200-lb-tanks/ 212 `��- | V | � / AU � U Township 35 South. �.+,�c_u�� _ ____ � � n __ . . . . ^^~ Township 35 South, "iEC��V��.Ctia �5 L L V I I, L H U A U Range 40 East .2% (i00' Right -of -Way) +_ Section Line eE3, 62' ro l ✓�+ N00° 04' 28w E 46 62' BEARING BASIS 6 -- Gast edge of Asphalt, Pavement East edge of Asphalt vement Oy of vale' �` f ✓e --�o ioP of Swale - .-•- I� / -ja -- - ---- _ .- - -- - -1--� -._ .- _. v>. Toe .—Tae „ v a --� r✓ Toe of Swale---, 'T-•—ut- --i-'— r m ✓ ' ,� — �i--'�—--•-•-- -- —ice r � r f�+ � ✓�;--i—�-- _._.--- .—_—.._.r. _.� --•-- +�� -- -- �' r Top of wale •� i` ���.\ P y+. �. r�Y9 v i�p of Swale ✓fir ' so'e�eso r'--OD° 04`. 8° 63. 59'--- �— �✓�r-- _ ✓ ✓o dls e � ✓� .. �r :: — ¢tea Ili\, jl `= ° r¢ ✓d+ uoxlroR ra 71 tIn o ✓¢ R l I Ii !j ✓d 21. 95, D.30' - ryiw �+ ✓� rr° I Zf + n •4 42. i10' f /S err r "t a . -� L. d..- J`j 6'd o ', �'�'+ ✓a P w w ."'r V7r", rya r. �A '0 a%n3` «,.r•.4',• .«...Y...v.. {. � III IIII �nw _ U:�Illiagil � C .• rs i � I i w .. ( �IlPo 11 ,P` I eilll : 42. a0' •-t {- o - o v "° ._..� ;�� I III ✓ '�, aq t' I 48. 42' CONCRETE c +✓ 376. a7' 55. 54 0 42, 00' 1 — — — oz�t — — — a•- — — 7.80 ✓S ✓� l5. a �� 'QQri Zd 13. 75' _ � O 24.00' o.E@' c .' 2a.13'—j �p, m I as I 1 mmti Ctlo r '�y � Ems r W � CO m %33.UT 20.40' ° )I �w+fD`L q�y' W BEN�N NARK 16.64' `' Tap ,Qf 1/21 Iron Rod and ✓� o l5.eo' e f p_ Capp it Be •RiS 2391 a = is S 166. 5i & E 150. 56' ✓¢ ✓m �j r o I I I � 60.,00' �� — i76.98' — — 0 fir' Woo 6xlsnno 1 a+ — _ BnSMr�6MI, \, 11� 1 ! 1 00 �r I CONCRETE ✓ 6, rd' f � � _ .�.� "` � j'. I aeon ✓¢dam¢ 1 _ _ . _ } r > a� , :s i .. .'7.. �_, .'�- ::" r I `I :,' �I_ (.. �; t, .. • "� . ': ° Pdt�{ ..'fir-�.;,., .��.. t�,.�- .5 ��, y �� 11/16/2020 Chapter 4 \/ Piping Installations, 2017 FBC -Fuel Gas, 6<sup>(l ~',up> edition i UpCodes TABLE 402,4(28) SCHEDULE 40 METALLIC PIPE Gas Undiluted Propane Inlet Pressure 11.0 in. w.c. Pressure Drop 0.5 in. w.c. Specific Gravity 1.50 INTENDED USE Pipe sizing between single- or second -stage (low pressure) regulator and appliance. PIPE SIZE (inch) Nominal 1/2 3/4 1 11/4 11/2 2 2'/2 3 4 Actual ID 0.622 ��M?41 1.049 1.380 1.610 2.067 2.469 3.068 4.026 Length (ft) Capacity in Thousands of Btu per Hour 10 291 60B 1,150 2,350 3,520 6,790 10,800 19,100 39,000 212_ 200 418 787 1,620 2,420 4,660 7,430 13,100 26,800 30 160 336 632 1,300 1,940 3,750 5,970 10,600 21,500 40 137 287 541 1,110 1,660 3,210 5,110 9,030 18,400 50 122 255 480 985 1,480 2,840 4,530 8,000 16,300 60 110 231 434 892 1,340 2,570 4,100 7,250 14,800 80 101 212 400 821 1,230 2,370 3,770 6,670 13,600 100 94 197 372 763 1,140 2,200 3,510 6,210 12,700 125 89 185 349 716 1,070 2,070 3,290 5,820 11,900 150 84 175 330 677 1,010 1,950 3,110 5,500 11,200 175 74 155 292 600 899 1,730 2,760 4,880 9,950 200 67 140 265 543 814 1,570 2,500 4,420 9,010 250 62 129 243 500 749 1,440 2,300 4,060 8,290 300 58 120 227 465 697 1,340 2,140 3,780 7,710 350 51 107 201 412 618 1,190 1,900 3,350 6,840 400 46 97 182 373 560 1,080 1,720 3,040 6,190 450 42 89 167 344 515 991 1,580 2,790 5,700 500 40 83 156 320 479 922 1,470 2,600 5,300 550 37 78 146 300 449 865 1,380 2,440 4,970 hftps:llup.codeslviewerlflodda/fl-fuel-gas-code-2017/chapterl4lgas-piping-installations#402 1/2 11/16/2020 Chapter4, Piping Installations, 2017 FBC - Fuel Gas, 6<sup>— �Jp> edition I UpCodes TABLE 402.4(30) SEMIRIGID COPPER TUBING Gas Undiluted Propane Inlet Pressure 11.0 in. w.c. Pressure Drop 0.5 in. w.c. Specific Gravity 1.50 INTENDED USE Sizing between single or second stage (low-pressure regulator) and appliance. TUBE SIZE (inc Nominal K $ L 1/4 3/8 1/2 5/g 3/4 1 11/4 11/2 2 AC R 3/8 1/2 5/8 3/4 /g 1118 13/8 — — Outside 0.375 0.500 0.625 0.750 0.875 1.125 1.375 1.625 2.125 Inside 0.305 0.402 0.527 0.652 0.745 0.995 1 1.245 1.481 1.959 Le gth Capacity in Thous . ds of Btu per Hour 10 45 93 188 329 467 997 1,800 2,830 5,890 20 31 64 129 226 1 685 1,230 1,950 4,050 30 25 51 104 182 258 550 991 1,560 3,250 40 21 44 89 155 220 471 848 1,340 2,780 50 19 39 79 138 195 417 752 13180 2,470 60 17 35 71 125 177 378 681 1,070 2,240 70 16 32 66 115 163 348 626 988 2,060 80 15 30 61 107 152 324 583 919 1,910 90 14 28 57 100 142 304 547 862 1,800 100 13 27 54 95 134 287 517 814 1,700 125 11 24 48 84 119 254 458 722 1,500 150 10 21 44 76 108 230 415 654 1,360 175 NA 20 40 70 99 212 382 602 1,250 200 NA 18 37 65 92 197 355 560 1,170 250 NA 16 33 58 82 175 315 496 1,030 300 NA 15 30 52 74 158 285 449 936 350 NA 14 28 48 68 146 262 414 861 400 NA 13 26 45 63 136 244 385 801 https:Hup.codes/viewerlflDridalfl-fuel-gas-code-2017/chapter/4/gas-piping-installations#402 1/2 � l TABLE 402.4(32) - :UGATED STAINLESS STEEL TUBING Gas I Undiluted Propane I Inlet Pressure 1 11.0 in. w.c. I I Pressure Drop 10.5 in. w.c. Specific Gravity 1 1.50 INTENDED USE: SIZING BETWEEN SINGLE OR SECOND STAGE (Low Pressure) REGULATOR AND THE APPLIANCE SHUTOFF VALVE TUBE -SIZE EHD) Flow Designation 13 15 18 19 23 1 2 30 1 1 37 1 39 46 1 48 60 1 62 Length (ft) Capaci ' Thousands of Btu per Hour 5 72 99 181 211 355 426 744 863 1,420 1,638 2,830 3,270 5,780 6,550 10 50 69 129 150 254 303 ,,5 605 971 1,179 1,990 2,320 4,110 4,640 157'39 55 104 121 208 248 422 490 775 972 1,620 1,900 3,370 3,790 20 34 49 91 106 183 216 365 425 661 847 1,400 1,650 2,930 3,290 25 30 42 82 94 164 192 325 379 583 762 1,250 1,480 2,630 2,940 30 28 39 74 87 151 177 297 344 528 698 1,140 1,350 2,400 2,680 40 23 33 64 74 131 153 256 297 449 610 988 1,170 2,090 2,330 50 20 30 58 66 118 137 227 265 397 548 884 1,050 1,870 2,080 60 19 26 53 60 107 126 207 241 359 502 805 961 1,710 1,900 70 17 25 49 57 99 117 191 222 330 466 745 890 1,590 1,760 80 15 23 45 52 94 109 178 208 307 438 696 833 1,490 1,650 90 15 22 44 50 90 102 169 197 286 414 656 787 1,400 1,550 100 14 20 1 41 47 85 98 159 186 270 393 621 746 1,330 1,480 150 11 15 31 36 66 75 123 143 217 324 506 611 1,090 1,210 200 9 14 28 33 60 69 112 129 183 283 438 531 948 1,050 250 8 12 25 30 53 61 99 117 163 254 390 476 850 934 L--300-- - r_ --8 - ..11- --23-- ---26 - --50 -- --57 - - -90- 107 - - -147- - -234--- -357-- _ 434.. j -777 j-85-4 - rI.�, � - -...- ,,,n,, , ,vUL - OV-t.0 „u,,, I NUunu NCI syuatU Inl:n = 0.0U0 Kra, l-incn water column = U.Z4?5?i KF'a, 7 britisn tnermal Unit per hour = 0.2931 W, 1 cubic foot per hour = 0.0283 m3/h, 1 degree = 0.01745 rad. Notes: 1. Table includes losses for four 90-degree bends and two end fittings. Tubing runs with larger numbers of bends or fittings shall be increased by an equivalent length of tubing to the following equation: L = 1.3n where L is additional length (feet) of tubing and n is the number of additional fittings or bends. 2. EHD-Equivalent Hydraulic Diameter, which is a measure of the relative hydraulic efficiency between different tubing sizes. The greater the value of EHD, the greater the gas capacity of the tubing. t R122H, R222H, R222, R232A and. R232E Series instruction Manual-r..r�•..r�.�,�. MCK2158 November 2015 RR 122H., R222H,. R222, R232A and R232E Series Instruction Manua . W WARNING Failure to follow these instructions or equipment could result lean explosion and/or fire causing property damage and personal Injury or death. Elsher® equipment must be installed, operated and maintained In accordance with:federal, state and local codes and aeabrAhAruciions. i,ne in' aaarion,imar'="r states mustalsptomply with NFPA No. 64 and 69 sitandards. Only personnel trained in the proper procedures, codes, standards and regulations of the LP -Gas Industry should Install and.service thls equipment Things: to tell the gas customer., 1. Show the customer the vent or vent assembly or vent tube. Stress thatthis opening must remain unobstructed at all times. Telf the customerto check the vent .opening after a.freezing rain; sleet storm or snow to make sure ice has not•Tormed inure vent. 2.. Show. the -customer the shutoff valve on.the container. The customer should close this valve immediately if gas Is smelled, appliance pilot lights fail to stay on orappear higher than usual or any other abnormal situation occurs. -Q -Tn3t 4F.in-.+rrd4r-lmarAn.nat�:c/mcrr-nhm 'ssnV.}riao_nA[ra-!!sa -_. >i N.nrrYsr W..tY.'r.Y.v»••4rKY• `: �.. J - _ regulator if the regulator vents gas or a leak develops In the. system: Only a.qualmed gas service person should install or service the regulator. 4; Tell the customer to. call your company to have a leak check performed .if the gas supply has been shutoff or interrupted for any reason. A leak check -must=ne-peRormaa'�y-a puaiinea-gasservice-person on the.piping system immediately after turning on the gas supply: 4)" A-V _po R232A Type RIM VpeA222. iyee R232E figure 1. R122H, R222H, R222, R232A and R232E Series Regulators ,! ntre_itls ar_ to a7re Scope of the Manual This Instruction Manual covers installation and maintenance for.the R122H, KUH, R222; R232Aand R232E Series regulators, which.indudes.first stage, second stage, integral hnte�,clt3�tA.r3fxf irst�rat,� PISY�S CAf11f�fR�t1IA�(�CA�4_COsiyR LP -Gas vapor -service applications. They are notto be used on liquid service. (FISHER),EMERSON. ' R122H, R222H, R2.22, R232A and R232E Series LP -Gas Regulators Specifications Specifications and Tables 1 and 2 list the specifications for these regulators: Contact the.factory if the regulator is to be used on any service other than LP -Gas, natural gas or air. The following information is located on the spring case: type number, orifice size, spring range and date of manufacture. -e�r�aie-caps= rce• e's rsre oil. 1/9 NPT: #54 / 0.055 In. Drill on outlet and inlet ormce Sizes R122H Series: 0.15 in. / 3.8 mm R222 Series: 0.14 in.13.6 mm R232A, R232E and R222H Series; 0. #d m, q 3.�rttm Wide Open Co for Relief Sizing. 0.122.2 R222 Series: 18 R232A and R232E Series: 19 R222H Series: 37 Maximum Allowable inlet Pressure R122H, R222H, R232A and R2321PWjU. 250 psig / 17.2 bar �rirsr�a.Sm. erx.,.Ps.r.n.cn.t:... Maximum Emergency Inlet Pressure R122H,.R222H, R232A and R232E Series., 250 psig / 17.2.bar R229 Series(). 75 psi / 5.2. bar when used with a Fishery Types R122H, R222H or R6.22H first stage regulator. 40 psi 12.8 bar when used with any other Temperature Capabilities R122H,.R222H, R222, R232A and R232E Series: 20 to 160"F. / -29to 71 °Cor Pressure Registration Internal ••vuuet;•rresgure•ai'a�aara�cpvma 112221h[Series:10 psi10,69 bar or 5 psi /0;35 bar R122H Series: 10 psi / 0.69 bar R222 Series: Second Stage.11 in. w.c.127 mbar R232A Series: First Stage. approximately _9'psig I e 0.62 bar at 100 psig / 6.9.bar, 5.0 SCFH / IA2 Nm3/h Second Stage:ll in. wo. / 27 mbar iM....,..; t3.=..:.� ..1.yMlb. V Of 14.�.rt.01.)f-V WHO.- 100 psig 16.9 bar, 50. SCFH / 1.42 Nm31h Second Stage; 2 psig / 0,14 bar Pllet Pressure Spring Ranges ,R222H Series: 8 to 11.9 psig10.55 to 0.82 bar or 4 to 6 psig /0.28 tc.0.41 bar R122H Serles: 10 psig / 0.69 bar +/-1 psig 10.07 bar r..... y.,i• ...e usol -1trul r-au�ua,au,o/ R222 Series: Second Stage: 9.6 to 13 in. w.o. / 24 to 32 mbar R232A Series: FhstStage: non-adjustable SecondStage:.102 to 13 In. w.c. / 26 to 32 mbar R232E Series: First Stage: non -adjustable - Second Stage:1. to 2.2 psig 10;07 to 0.16 bar .c pp. e,.wsar.ef w..ya..w R222H Series with POL 2.12 Ibs 1961.8 g R222H Series with NPT fitting:1.73 Ills 1.784.E g R122H Series: 4.2 tbs/ 544 g R222,Series.,, 1.4 ibs / 635 g R232A:and R232E Series with POL: 1.9 tbs.l 865 g .R,2325�& a ld R F S si? s:�atiftt ltl1PS 4rttinm 1,1bs / 671 g f. Irr Ihadmi the R222 Sedea matfurrcuons dreipg &Maxiirwm Emergency lydel Pressue corodilmn Owso Inhtprossaas and Ow R222 6eMa ra8ef pedormenoe w� tirral awrroheam presstan to 2 W 1al4 bar orless. 2. Product haspassed Fisher tasting fortoctrup, reW ste(1404srharge and reseal down to 40IF l4M. Description Second Stage Low Pressure Regulator The Type R222 second stage regulator provides low pressure, inches of.water column; delivery pressure. it Is set at 11 in. w.c. / 27 mbar pressure and comes with a high capacity internal relief valve. The regulators are painted PALM GREEN. Integral Two -stage Regulator The Type R232A integral two -stage regulator contains a non-adjustable first stage' regulator on the inlet. The second stage provides 11 in. w.c.127 mbar outlet pressure. The secondstage portion has a high capacity Internal relief valve construction. The first stage does not have an internal relief valve. The regulators are painted GRAY with a BLACK CAP. Integral Two psig Service Regulator yN n��c�uuvyeat-�ravNaiy sci:iriix rt:�iiiafvP contains a non-adjustable first stage regulator on the Inlet. The second stage provides:2 psig 10.14 bar outlet pressure. The second stage portion has a high capacity internal relief valve construction. The first stage: does not have an internal relief valve. The regulators are painted GRAY with a WHITE CAP.' First Stage. Regulators Types R122H and R222H regulators are designed for high pressure (pounds per square inch) vapor service. These regulators:have high capacity internal relief valves. When. used on first stage stavice, the Type R122H regulator �ftsex?e�ttr�#rnrc�.trlo-s��-s��s,�nt�Ar 4h.mt�! 0:69 barinlet pressur>r too secontl stage regulator The. Type R222H regulator reduces.container pressure to R122H, R222H, R222, R232A and R232E Series AVOW LP -Gas Regulators JFrt ! _ VENT. POINTED DOWN Figure 2. Regulator wfth Vent Pointed Down Tabie i. Relief Valve speacations TYPICAL SETPOINT NOMINAL RELIEF VALVE, MAXIMUM OUXIMA 411111rM hir, . gi%RENIOVED TYPE START=TO DISCHARGE InII pmsar9 I4laxlmum OtdlBt Presauie pal har p9l: bar. pig. bar pslg_ bar R122H 10 Q69 iB 1.10` .250 17:2 NotApplkabls R222H 6 i0 0:35 0.89 9 18 0.82 1.10 250 17:2 NotApplk" R222 11 111. w.G 27 mbar 1 0.07 30 2.07, 2.0 0.14 R232An) 11 In. w.a 27 mbar �r79 �) 1 .'J;5 -i, 0,07 -024 _��_ 260 `' 17,2 y' 2.0 014 -'� .. .i. •5.0 0.35 fS Ze1•• ..I -z .I L L Far bleVel two-atage regNabn, 8Ia Second WAP CM 19 Moved Table 2 Capacity, Connection sizes and. Vent Orientation 3 ' R122H, R222H, R222, R232A and R232E Series LP -Gas Regulators Figure 3. Tank Installation approximately 10psig/0.69bar or5pslg/0.35bar inlet General Installation Instructions pressure to a second stage. regulator. On final, stage service Before instaUinghe regulator, the regulator reduces container pressure for a high pressure bumer. The regulator Is painted RED Check for damage. which might have occurred In shipment Installation WARNING All vents'should he kept open to pem*, free flow of. Air. in and out of the regulator_ Protect vent openings against the entrance of rain;. .V{HILrJY VNW Y/IYY V♦'I;.,IfYI/p,dIIMV,.U1p6V,ll' waterfrom an Irrigation system or any other foreign materlal.that could plug the vent or vent line or accumulate in the vent.line. LP -Gas may discharge to the atmosphere through the vent. An obstructed vent which.limits air or gas flow can cause i unormaily1titgn. pressuralhat .couid result in personal Injuryor.propertydamage. The Types R232A, R232E, R122H and R222H are not suitable for indoor installations. Failure to use a vent tine with Type R222 second stage regulators imindoor applications can cause a hazardous accumulation of gas which could result in personal Injury or property damage.. Never use the Types R122H, R222H and R232E (pounds-to=pounds) regulators on low pressure (inches of water column) service because personal Injury or property • Check for and remove any dirt or foreign material, -Whidrrmay-Raveaccumura-Win= ne-reg"of%bofly • Replace old pigtails. Blow: out any debris,: dirt or copper sulfate in the copper tubing and the pipeline. Apply pipe compound to the male threads of the pipe before installing the regulator: • Make.sure.gas.flow through the regulator is in the -same�airecuon'as,lne arrow on=tne,doay;"inler and "Outlet connections are clearly marked. instailatlon Location The installed. regulator should be adequately protected from vehicular traffic and damage from :ellh6 -A-W-1=hOV f-4dsZ u +a. • Install the regulator with the vent pointed vertically down, see Figure.2 if the vent cannot be installed in a. vertically down position, the regulator must -be Installed ' under a separate protective cover. Installing the regulator withthe vent down allows condensation to drain; minimizes the entry of water or other.debris from-enwring:the vent and minimizes.vent blockage from freezing precipitation: • Do not instaA:the regulator Ina location where there can be excessive water accumulation or ice formation,. such as direly beneath a down spout, gutter or roof line of building. Even.a protective hood may not provide -adequste,protedt ri in these ins nr es